Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Semin Thorac Cardiovasc Surg ; 35(1): 19-30, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-35091051

RESUMO

We performed a contemporary assessment of clinical and radiographic factors of stroke after thoracic endovascular aortic repair (TEVAR). Patients undergoing TEVAR from 2006 to 2017 were identified. We assessed clinical and radiographic data, including preoperative head and neck computed tomography, Doppler ultrasonography, and intraoperative angiography. Our primary outcome was stroke after TEVAR. Four hundred seventy-nine patients underwent TEVAR, mean age 68.1 ± 19.5 years, 52.6% male. Indications for TEVAR included aneurysms (n = 238, 49.7%) or dissections (n = 152, 31.7%). Ishimaru landing zones were Zone 2 (n = 225, 47.0%), Zone 3 (n = 151, 31.5%), or Zone 4 (n = 103, 21.5%). Stroke occurred in 3.8% (n = 18) of patients, with 1.9% (8) major events (modified Rankin Scale >3). Pathophysiology was predominantly embolic (n = 14), and occurred in posterior (n = 6), anterior (n = 6), or combined circulation (n = 4), and in the left hemisphere (n = 10) or bilateral (n = 6). Univariate analysis suggested use of lumbar drain (33.3% versus 57.2%, P = 0.04), inability to revascularize the left subclavian artery (16.7% vs 5.2%, P = 0.04) and number of implanted components (2.5 ± 1.2 vs 2.0 ± 0.97, P = 0.03) were associated with stroke. Multivariable analysis identified number of implanted components (OR 1.7, 95%CI 1.17-2.67 P = 0.00) and inability to revascularize the left subclavian artery as independent predictors of stroke. Stroke was associated with a higher perioperative mortality (27.8% vs 3.9%, P < 0.01). Stroke after TEVAR is primarily embolic in nature and related to both anatomic and procedural factors. This may have important implications for device development in the era of endovascular arch repair.


Assuntos
Aneurisma da Aorta Torácica , Implante de Prótese Vascular , Procedimentos Endovasculares , Acidente Vascular Cerebral , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Feminino , Correção Endovascular de Aneurisma , Implante de Prótese Vascular/efeitos adversos , Fatores de Risco , Procedimentos Endovasculares/efeitos adversos , Resultado do Tratamento , Aorta Torácica/cirurgia , Acidente Vascular Cerebral/etiologia , Aortografia/métodos , Estudos Retrospectivos , Aneurisma da Aorta Torácica/cirurgia
3.
Ann Vasc Surg ; 46: 307-313, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28647641

RESUMO

BACKGROUND: The impact of left subclavian artery (LSA) revascularization before thoracic endovascular aortic repair (TEVAR) on cerebrovascular flow is not well described. We studied bilateral vertebral and carotid artery flow characteristics before and after TEVAR to evaluate the hemodynamic effects of LSA revascularization. METHODS: Seventy-four patients with mixed etiologies (mean age 70.9 ± 10.5 years) underwent LSA revascularization and TEVAR (2006-2016) and had available preoperative and postoperative carotid duplex study available. Data from patient demographics, procedures, preoperative, and postoperative carotid duplex studies were gathered. Revascularization was by left common carotid artery (LCCA) to LSA bypass (n = 70, 94.6%) or LSA to LCCA transposition (n = 4, 5.4%). RESULTS: Duplex confirmation of antegrade left vertebral artery (LVA) flow decreased significantly after TEVAR with LSA revascularization (100.0% vs. 77.9%, P < 0.001). Incidence of retrograde LVA flow increased from 0.0% to 8.3% (P = 0.063). Postoperatively, LVA bidirectional flow was observed in 3 patients (4.4%). Flow directions in the right vertebral artery (RVA) did not change significantly. Peak systolic velocity (PSV) in the LVA decreased significantly after TEVAR from 55.1 ± 22.0 cm/s to 35.9 ± 26.3 cm/s (P < 0.001). In contrast, PSV increased in the RVA and the right internal carotid artery (ICA; 52.2 ± 21.7 cm/s to 63.2 ± 23.3 cm/s, P = 0.012 and 95.3 ± 46.8 cm/s to 102.8 ± 42.9 cm/s, P = 0.011). PSV did not change significantly in the left ICA. At mean follow-up of 36.6 ± 26.8 months, primary bypass patency was 100.0%. Postoperatively, one case of temporary spinal cord ischemia was seen (1.4%). Stroke rate was 6.9% (n = 5, 100.0% embolic), all without permanent disabilities. Stroke circulation distribution was 60.0% posterior, 20.0% anterior, and 20.0% mixed. Location of stroke was left sided (n = 2) or in both hemispheres (n = 3). There were no deaths at 30 days. Neurological events during follow-up included 3 new strokes. All-cause mortality rate during follow-up was 12.2% (n = 9). CONCLUSIONS: Adjunctive LSA revascularization in the setting of zone 2 TEVAR coverage is associated with hemodynamic vertebral artery changes. Future studies in larger sample sizes should evaluate whether these novel findings are an important determinant of postoperative neurologic events.


Assuntos
Aorta Torácica/cirurgia , Doenças da Aorta/cirurgia , Implante de Prótese Vascular , Artéria Carótida Primitiva/cirurgia , Circulação Cerebrovascular , Procedimentos Endovasculares , Hemodinâmica , Artéria Subclávia/cirurgia , Artéria Vertebral/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Velocidade do Fluxo Sanguíneo , Implante de Prótese Vascular/efeitos adversos , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiopatologia , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Isquemia do Cordão Espinal/etiologia , Isquemia do Cordão Espinal/fisiopatologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/fisiopatologia , Artéria Subclávia/diagnóstico por imagem , Artéria Subclávia/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia Doppler Dupla , Artéria Vertebral/diagnóstico por imagem
4.
Semin Thorac Cardiovasc Surg ; 29(2): 173-178, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28823323

RESUMO

One of the most dreaded complications of acute aortic dissection is end-organ malperfusion. We summarize current evidence and describe our treatment paradigm in the setting of malperfusion in aortic dissection. Given the difficulty with identifying isolated visceral malperfusion in aortic dissection, both in the literature as well as in our practice, we have broadened the discussion to include data examining the presentation complex of malperfusion, particularly if mesenteric ischemia is identified. The approach to treating malperfusion syndrome is different depending on whether the patient presents with type A dissection vs type B dissection with malperfusion. Although thoracic endovascular aortic repair has emerged as the dominant strategy for resolving malperfusion for complicated type B dissection, fenestration may still have a role in its treatment. In contrast, for type A aortic dissection presenting with visceral malperfusion, the concept of operative repair after restoration of end-organ perfusion has been proposed with increasing frequency in recent reports. At the University of Michigan, we apply a patient-specific algorithm, based on the presence of malperfusion with end-organ dysfunction. In those patients presenting with visceral malperfusion, we prefer to first fenestrate, await resolution of the malperfusion syndrome and then perform central aortic repair. We recognize that other groups have implemented similar algorithms to reduce the dismal results of operative procedures in this cohort. However, the most appropriate period of delay remains unknown and there is a persistent risk of rupture before repair is performed. Future studies should be performed to determine whether these various treatment paradigms have merit.


Assuntos
Aneurisma Aórtico/complicações , Dissecção Aórtica/complicações , Isquemia/etiologia , Isquemia Mesentérica/etiologia , Vísceras/irrigação sanguínea , Algoritmos , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Dissecção Aórtica/cirurgia , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/fisiopatologia , Aneurisma Aórtico/cirurgia , Aortografia/métodos , Implante de Prótese Vascular , Angiografia por Tomografia Computadorizada , Procedimentos Clínicos , Procedimentos Endovasculares , Medicina Baseada em Evidências , Humanos , Isquemia/diagnóstico por imagem , Isquemia/fisiopatologia , Isquemia/cirurgia , Isquemia Mesentérica/diagnóstico por imagem , Isquemia Mesentérica/fisiopatologia , Isquemia Mesentérica/cirurgia , Michigan , Fluxo Sanguíneo Regional , Resultado do Tratamento
5.
Ann Vasc Surg ; 43: 302-308, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28483612

RESUMO

BACKGROUND: Aortic stiffness is an independent predictor of cardiovascular mortality. In this study, the effect of thoracic endovascular aortic repair (TEVAR) on aortic stiffness is investigated by measuring aortic pulse wave velocity (PWV) in an ex vivo porcine model. METHODS: Fifteen fresh porcine thoracic aortas were connected to a benchtop pulsatile system. Intraluminal pressures were recorded in the ascending aorta and at the celiac trunk using a needle connected to a pressure sensor. The distance between the needles was divided by the time difference between the base of the pressure peaks to calculate aortic PWV at baseline and after stent-graft deployment and distal stent-graft extension. RESULTS: Mean aortic PWV was 5.0 m/s at baseline. PWV increased by 4% after proximal stent-graft deployment (P = 0.09) and by 18% after stent-graft extension (P < 0.001). Pulse pressure in the nonstented ascending aorta increased by 11.0 ± 1.2 mm Hg after proximal stent-graft deployment (P < 0.001) and by 17.3 ± 1.5 mm Hg after stent-graft extension (P < 0.001). The increases in PWV and pulse pressure showed a positive linear correlation with the percentage of stent-graft coverage (P < 0.001 and P < 0.001). CONCLUSIONS: In this experimental setup, aortic stiffness increased after stent-graft deployment, dependent on the percentage of the aorta that was covered by stent graft. These results show that TEVAR leads to significant changes in aortic hemodynamics, which merits evaluation in the clinical setting.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Rigidez Vascular , Animais , Aorta Torácica/fisiopatologia , Pressão Arterial , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Técnicas In Vitro , Modelos Lineares , Modelos Animais , Desenho de Prótese , Fluxo Pulsátil , Análise de Onda de Pulso , Sus scrofa
6.
Ann Vasc Surg ; 42: 143-149, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28390915

RESUMO

BACKGROUND: We aimed to identify predictors of stable aortic dimensions in medically managed type B aortic dissections (TBAD). METHODS: Medically managed TBAD patients from the International Registry of Acute Aortic Dissection with available aortic measurements at up to 24 months were included. Growth rate was calculated by dividing the largest descending diameter at the latest end point not influenced by intervention minus initial descending diameter, by the recorded time interval. Patients were split into 2 groups: without aortic growth (<0.0 mm/year, group I) and with aortic growth (>0.0 mm/year, group II). RESULTS: 219 patients had available data for our inclusion criteria and comprised group I (n = 89, 40.6%) and group II (n = 130, 59.4%). Mean expansion rate of the total cohort was 0.19 ± 0.81 cm, mean expansion rate in group I was -0.47 ± 0.54 cm, and in group II, it was +0.63 ± 0.64 cm. Patients in group I were more frequently of Asian descent (15.9% vs. 3.1%, P = 0.001), showed more often intramural hematoma on imaging (57.3% vs. 30.0%, P < 0.001) and demonstrated complete false lumen thrombosis more frequently (25.0% vs. 9.9%, P = 0.009). Group II patients were more Caucasian (77.3% vs. 92.2%, P = 0.002), presented more with posterior chest pain (57.8% vs. 74.7%, P = 0.025), back pain (68.2% vs. 80.2%, P = 0.046), a visible double lumen (50.6% vs. 63.8%, P = 0.050), dissection originating from the left subclavian artery (51.2% vs. 68.5%, P = 0.011), and a completely patent false lumen (37.5% vs. 62.4%, P = 0.002). Mortality rates between groups were similar (2.2% vs. 1.5%, P = 0.708). Complete false lumen thrombosis was an independent predictor of no growth (hazard ratio [HR]: 3.640, P = 0.011), while a larger sinotubular junction (STJ) (HR: 0.304, P = 0.004) and female gender (HR: 0.325, P = 0.030) were negative predictors of no growth. CONCLUSIONS: Complete false lumen thrombosis was a predictor of no growth, while a large STJ and female gender were predictors of aortic growth. This study might help predict which medically treated TBAD patients might show a stable clinical course during follow-up.


Assuntos
Aneurisma Aórtico/terapia , Dissecção Aórtica/terapia , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Progressão da Doença , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Fatores de Risco , Fatores Sexuais , Trombose/diagnóstico por imagem , Fatores de Tempo , Resultado do Tratamento
7.
Ann Vasc Surg ; 42: 303.e11-303.e14, 2017 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-28390917

RESUMO

BACKGROUND: Deployment of a stent graft for the treatment of aortic dissections is normally performed in the true lumen. However, in some rare occasions landing in the false lumen may be appropriate. METHODS: We present 2 different cases of chronic aortic dissection, where we opted to land the stent graft into the false lumen to treat the associated aneurysm. RESULTS: For the first case, the goal of thoracic endovascular aortic repair (TEVAR) was to exclude the aneurysm from within the false lumen because of a slit-like true lumen. In the second case, the visceral arteries came off the false lumen, with the renal vessels from the true lumen. False lumen TEVAR was performed, and the infrarenal aorta fenestrated, as to ensure adequate perfusion. CONCLUSIONS: These different clinical scenarios show how false lumen TEVAR for chronic dissections with associated aneurysms can be an alternative treatment approach and highlight the importance of assessing the origin of branch vessels and the possible necessity of reperfusion of these, before TEVAR is performed.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/instrumentação , Doença Crônica , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/instrumentação , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Fluxo Sanguíneo Regional , Stents , Resultado do Tratamento
8.
J Thorac Cardiovasc Surg ; 153(4): S74-S79, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28168983

RESUMO

OBJECTIVE: Advancements in cardiothoracic surgery prompted investigation into changes in operative management for acute type A aortic dissections over time. METHODS: One thousand seven hundred thirty-two patients undergoing surgery for type A aortic dissection were identified from the International Registry of Acute Aortic Dissection Interventional Cohort Database. Patients were divided into time tertiles (T) (T1: 1996-2003, T2: 2004-2010, and T3: 2011-2016). RESULTS: Frequency of valve sparing procures increased (T1: 3.9%, T2: 18.6%, and T3: 26.7%; trend P < .001). Biologic valves were increasingly utilized (T1: 35.6%, T2; 40.6%, and T3: 52.0%; trend P = .009), whereas mechanical valve use decreased (T1: 57.6%, T2: 58.0%, and T3: 45.4%; trend P = .027) for aortic valve replacement. Adjunctive cerebral perfusion use increased (T1: 67.1%, T2: 89.5%, and T3: 84.8%; trend P < .001), with increase in antegrade cerebral techniques (T1: 55.9%, T2: 58.8%, and T3: 66.1%; trend P = .005) and hypothermic circulatory arrest (T1: 80.1%, T2: 85.9%, and T3: 86.8%; trend P = .030). Arterial perfusion through axillary cannulation increased (T1: 18.0%, T2: 33.2%, and T3: 55.7%), whereas perfusion via a femoral approach diminished (T1: 76.0%, T2: 53.3%, and T3: 30.1%) (both P values < .001). Hemiarch replacement was utilized more frequently (T1: 27.0%, T2: 63.3%, and T3: 51.7%; trend P = .001) and partial arch was utilized less frequently (T1: 20.7%, T2: 12.0%, and T3: 8.4%; trend P < .001), whereas complete arch replacement was used similarly (P = .131). In-hospital mortality significantly decreased (T1: 17.5%, T2: 15.8%, and T3: 12.2%; trend P = .017). CONCLUSIONS: There have been significant changes in operative strategy over time in the management of type A aortic dissection, with more frequent use of valve-sparing procedures, bioprosthetic aortic valve substitutes, antegrade cerebral perfusion strategies, and hypothermic circulatory arrest. Most importantly, a significant decrease of in-hospital mortality was observed during the 20-year timespan.


Assuntos
Aneurisma Aórtico/cirurgia , Dissecção Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese Vascular/tendências , Implante de Prótese de Valva Cardíaca/tendências , Doença Aguda , Idoso , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Valva Aórtica/fisiopatologia , Bioprótese/tendências , Prótese Vascular/tendências , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/mortalidade , Feminino , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Recuperação de Função Fisiológica , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
9.
Eur J Cardiothorac Surg ; 51(4): 783-789, 2017 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28043989

RESUMO

Objectives: To quantify the impact of thoracic endovascular aortic repair (TEVAR) on radial aortic strain with the aim of elucidating stent-graft-induced stiffening and complications. Methods: Twenty fresh thoracic porcine aortas were connected to a mock circulatory loop driven by a centrifugal flow pump. A high-definition camera captured diameters at five different pressure levels (100, 120, 140, 160, and 180 mmHg), before and after TEVAR. Three oversizing groups were created: 0-9% ( n = 7), 10-19% ( n = 6), and 20-29% ( n = 6). Radial strain (or deformation) derived from diameter amplitude divided by baseline diameter at 100 mmHg. Uniaxial tensile testing evaluated Young's moduli of the specimens. Results: Radial strain was reduced after TEVAR within the stented segment by 49.4 ± 24.0% ( P < 0.001). As result, a strain mismatch was observed between the stented segment and the proximal non-stented segment (7.0 ± 2.5% vs 11.8 ± 3.9%, P < 0.001), whereas the distal non-stented segment was unaffected ( P = 0.99). Stent-graft oversizing did not significantly affect the amount of strain reduction ( P = 0.30). Tensile testing showed that the thoracic aortas tended to be more elastic proximally than distally ( P = 0.11). Conclusions: TEVAR stiffened the thoracic aorta by 2-fold. Such segmental stiffening may diminish the Windkessel function considerably and might be associated with TEVAR-related complications, including stent-graft-induced dissection and aneurysmal dilatation. These data may have implications for future stent-graft design, in particular for TEVAR of the highly compliant proximal thoracic aorta.


Assuntos
Aorta Torácica/cirurgia , Implante de Prótese Vascular/métodos , Procedimentos Endovasculares/métodos , Animais , Aorta Torácica/fisiopatologia , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Modelos Animais de Doenças , Elasticidade , Procedimentos Endovasculares/efeitos adversos , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Stents , Estresse Mecânico , Sus scrofa , Suínos , Resistência à Tração
10.
J Vasc Surg ; 65(4): 964-971.e3, 2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27876516

RESUMO

BACKGROUND: The high-risk patient cohort of uncomplicated type B aortic dissections (uTBADs) needs to be clarified. We compared uTBAD patients treated with best medical treatment (BMT), with and without aortic growth, from the Acute Dissection Stent Grafting or Best Medical Treatment (ADSORB) trial database. Furthermore, we looked for trends in outcome for aortic growth and remodeling after BMT and thoracic endovascular aortic repair (TEVAR) and BMT (TEVAR+BMT). METHODS: BMT patients with available baseline and a 1-year follow-up arterial computed tomography scan were identified. True lumen and false lumen diameter was assessed at baseline and at follow-up. Patients with false lumen growth (group I) and without false lumen growth (group II) were compared. Predictors of false lumen and total lumen (aortic) growth were identified. Lastly, BMT outcomes were compared with BMT+TEVAR for false lumen thrombosis and change in false lumen and total aortic diameter in four sections: 0 to 10 cm (A), 10 to 20 cm (B), 20 to 30 cm (C), and 30 to 40 cm (D) from the left subclavian artery. RESULTS: The dissection was significantly longer in group I than in group II (43.2 ± 4.9 cm vs 30.4 ± 8.8 cm; P = .002). The number of vessels originating from the false lumen at baseline was identified as an independent predictor of false lumen growth (odds ratio, 22.1; 95% confidence interval, 1.01-481.5; P = .049). Increasing age was a negative predictor of total aortic diameter growth (odds ratio, 0.902; 95% confidence interval, 0.813-1.00; P = .0502). The proximal sections A and B showed complete thrombosis in 80.6% in the BMT+TEVAR group compared with 9.5% in the BMT group. In these sections, changes from patent to partial or partial to complete thrombosis were observed in 90.3% of the TEVAR+BMT group vs 31.0% in the BMT group. In sections C and D, the change in thrombosis was 74.1% for the TEVAR+BMT group vs 20.6% for the BMT group. The false lumen diameter increase at section C was larger in the BMT group. Total lumen diameter decreased in sections A and B in the TEVAR+BMT group compared with an increase in the BMT group (-4.8 mm vs +2.9 mm, and -1.5 mm vs +3.8 mm, respectively). Sections C and D showed minimal and comparable expansion in both treatment groups. CONCLUSIONS: The new imaging analysis of the ADSORB trial patients identified the number of vessels originating from the false lumen as an independent predictor of false lumen growth in uTBAD patients. Increasing age was a negative predictor of aortic growth. Our analysis may help to identify which uTBAD patients are at higher risk and should receive TEVAR or be monitored closely during follow-up.


Assuntos
Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/terapia , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/instrumentação , Stents , Adulto , Fatores Etários , Idoso , Aorta Torácica/diagnóstico por imagem , Aorta Torácica/crescimento & desenvolvimento , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Aneurisma da Aorta Torácica/cirurgia , Aortografia/métodos , Implante de Prótese Vascular/efeitos adversos , Angiografia por Tomografia Computadorizada , Bases de Dados Factuais , Dilatação Patológica , Progressão da Doença , Procedimentos Endovasculares/efeitos adversos , Feminino , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Razão de Chances , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Retrospectivos , Fatores de Risco , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
11.
BMJ Open ; 6(11): e012270, 2016 11 17.
Artigo em Inglês | MEDLINE | ID: mdl-27856475

RESUMO

INTRODUCTION: Thoracic aortic stent grafts are orders of magnitude stiffer than the native aorta. These devices have been associated with acute hypertension, elevated pulse pressure, cardiac remodelling and reduced coronary perfusion. However, a systematic assessment of such cardiovascular effects of thoracic endovascular aortic repair (TEVAR) is missing. The CardiOvascular Remodelling following Endovascular aortic repair (CORE) study aims to (1) quantify cardiovascular remodelling following TEVAR and compare echocardiography against MRI, the reference method; (2) validate computational modelling of cardiovascular haemodynamics following TEVAR using clinical measurements, and virtually assess the impact of more compliant stent grafts on cardiovascular haemodynamics; and (3) investigate diagnostic accuracy of ECG and serum biomarkers for cardiac remodelling compared to MRI. METHODS AND ANALYSIS: This is a prospective, nonrandomised, observational cohort study. We will use MRI, CT, echocardiography, intraluminal pressures, ECG, computational modelling and serum biomarkers to assess cardiovascular remodelling in two groups of patients with degenerative thoracic aneurysms or penetrating aortic ulcers: (1) patients managed with TEVAR and (2) control patients managed with medical therapy alone. Power analysis revealed a minimum total sample size of 20 patients (α=0.05, power=0.97) to observe significant left ventricular mass increase following TEVAR after 1 year. Consequently, we will include 12 patients in both groups. Advanced MRI sequences will be used to assess myocardial and aortic strain and distensibility, myocardial perfusion and aortic flow. ECG, echocardiography and serum biomarkers will be collected and compared against the imaging data. Computational models will be constructed from each patient imaging data, analysed and validated. All measurements will be collected at baseline (prior to TEVAR) and 1-year follow-up. The expected study period is 3 years. ETHICS AND DISSEMINATION: This study has been approved by the University of Michigan IRB. The results will be disseminated through scientific journals and conference presentations. TRIAL REGISTRATION NUMBER: NCT02735720.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Biomarcadores/sangue , Procedimentos Endovasculares/efeitos adversos , Remodelação Ventricular , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Simulação por Computador , Ecocardiografia , Feminino , Humanos , Imageamento por Ressonância Magnética , Masculino , Michigan , Pessoa de Meia-Idade , Modelos Cardiovasculares , Estudos Prospectivos , Projetos de Pesquisa , Medição de Risco , Stents/efeitos adversos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Adulto Jovem
12.
Eur J Cardiothorac Surg ; 50(5): 955-961, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27247376

RESUMO

OBJECTIVES: To investigate the impact of thoracic endovascular aortic repair (TEVAR) on longitudinal strain and assess aortic tensile properties in order to better understand complications associated with TEVAR. METHODS: Twenty fresh thoracic porcine aortas were harvested and connected to a mock circulatory loop driven by a centrifugal flow pump at body temperature. Length measurements were conducted before and after TEVAR through aortic marking, high-definition imaging and custom-developed software under physiological pressure conditions (i.e. between 100 and 180 mmHg with 20 mmHg increments). Longitudinal strain was derived from length amplitude divided by the baseline length at 100 mmHg. Three groups of stent-graft oversizing were created (0-9, 10-19 and 20-29%). Finally, elastic properties of the aortic samples were assessed in both longitudinal and circumferential directions through uniaxial tensile testing. Longitudinal strain was compared before and after TEVAR, and stress-to-rupture was compared among specimens and locations. RESULTS: TEVAR induced a longitudinal strain decrease from 11.9 to 5.6% (P< 0.001) in the stented segments and a longitudinal strain mismatch between stented (5.6%) and non-stented segments (9.1%, P< 0.001). Stent-graft oversizing did not affect the magnitude of strain reduction (P= 0.77). Tensile testing showed that peak stress-to-rupture was lower for longitudinal (1.4 ± 0.4 MPa) than for circumferential fragments (2.3 ± 0.4 MPa, P< 0.001). In addition, longitudinal fragments were more prone to rupture proximally than distally (P= 0.01). CONCLUSIONS: This experimental study showed that TEVAR acutely stiffens the aorta in the longitudinal direction and thereby induces a strain mismatch, while tensile testing confirmed that longitudinal aortic fragments are most prone to rupture, particularly close to the arch. Such an acute strain mismatch of potentially vulnerable tissue might play a role in TEVAR-related complications, including retrograde dissection and aneurysm formation. The finding that TEVAR stiffens the aorta longitudinally may also shed light on systemic complications following TEVAR, such as hypertension and cardiac remodelling. These observations may imply the need for further improvement of stent-graft designs.


Assuntos
Aorta Torácica/cirurgia , Prótese Vascular , Animais , Aorta Torácica/fisiopatologia , Implante de Prótese Vascular/métodos , Elasticidade , Procedimentos Endovasculares/métodos , Teste de Materiais/métodos , Modelos Cardiovasculares , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Stents , Estresse Mecânico , Sus scrofa , Resistência à Tração
13.
Vasc Med ; 21(3): 251-63, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-27067136

RESUMO

Stanford type B aortic dissection (TBAD) is a life-threatening aortic disease. The initial management goal is to prevent aortic rupture, propagation of the dissection, and symptoms by reducing the heart rate and blood pressure. Uncomplicated TBAD patients require prompt medical management to prevent aortic dilatation or rupture during subsequent follow-up. Complicated TBAD patients require immediate invasive management to prevent death or injury caused by rupture or malperfusion. Recent developments in diagnosis and management have reduced mortality related to TBAD considerably. In particular, the introduction of thoracic stent-grafts has shifted the management from surgical to endovascular repair, contributing to a fourfold increase in early survival in complicated TBAD. Furthermore, endovascular repair is now considered in some uncomplicated TBAD patients in addition to optimal medical therapy. For more challenging aortic dissection patients with involvement of the aortic arch, hybrid approaches, combining open and endovascular repair, have had promising results. Regardless of the chosen management strategy, strict antihypertensive control should be administered to all TBAD patients in addition to close imaging surveillance. Future developments in stent-graft design, medical therapy, surgical and hybrid techniques, imaging, and genetic screening may improve the outcomes of TBAD patients even further. We present a comprehensive review of the recommended management strategy based on current evidence in the literature.


Assuntos
Aneurisma Aórtico/terapia , Dissecção Aórtica/terapia , Implante de Prótese Vascular , Fármacos Cardiovasculares/uso terapêutico , Procedimentos Endovasculares , Dissecção Aórtica/diagnóstico por imagem , Dissecção Aórtica/mortalidade , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/mortalidade , Aortografia/métodos , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Angiografia por Tomografia Computadorizada , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Humanos , Fatores de Risco , Resultado do Tratamento
14.
Vascular ; 24(2): 208-16, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26002781

RESUMO

Long-term outcomes of elective thoracic endovascular aortic repair (TEVAR) for degenerative thoracic aortic aneurysms (TAA) are not well defined. A review of the literature on the follow-up outcomes of elective TEVAR for degenerative TAA resulted in 22 relevant articles. Two- and five-year freedom from aneurysm-related death varied between 93.0% and 100.0%, and 82.4% to 92.7%, respectively. Two-year and five-year all-cause survival ranged between 68.0% and 97.2% and 47.0% to 78.0%, respectively. Follow-up ranged between 17.3 and 66.0 months. Most common endograft-related complication was endoleak, with reported rate between 1.4% and 14.8% during six months up to five years of follow-up. Endovascular reinterventions were reported in 0.0-32.3%, secondary open surgery was needed in 0.0% to 4.7% during follow-up. Aneurysm-related survival rates after elective TEVAR for degenerative TAA are acceptable. However, reported incidences of endograft-related complications vary considerably in the literature, but the majority can be managed with conservative treatment or additional endovascular procedures.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Implante de Prótese Vascular , Procedimentos Endovasculares , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/mortalidade , Prótese Vascular , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Implante de Prótese Vascular/mortalidade , Procedimentos Cirúrgicos Eletivos , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/instrumentação , Procedimentos Endovasculares/mortalidade , Humanos , Complicações Pós-Operatórias/etiologia , Fatores de Risco , Stents , Fatores de Tempo , Resultado do Tratamento
15.
Eur Heart J Suppl ; 18(Suppl E): E57-E63, 2016 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-28533718

RESUMO

The Thoracic Aortic Research Center (TARC) of the IRCCS Policlinico San Donato (PSD) aims to promote research on thoracic aortic diseases, to disclose the scientific knowledge and clinical experience and to develop new scientific paths within the Hospital and the aortic community, in collaboration with other national and international centres. Thoracic Aortic Research Center collaborates with many centres in both Europe (e.g. University of Utrecht, the Netherlands) and the USA (e.g. University of Michigan). This has led to multiple highly regarded publications in respected cardiovascular journals and has led to several PhD programmes resulting in doctorate degrees. Within Italy, in association with the Bioengineering School of the University of Pavia, TARC has founded the "BETA-lab" (Biomechanics for Endovascular Treatment of the Aorta laboratory), where MDs, Bioengineers, and PhD fellows conduct experimental studies using in vitro/ex vivo models of the physiologic aorta and aortic diseases. Furthermore, a database (iCardiocloud) where the medical imaging of cardiovascular patients from the PSD is structured, for in silico analysis utilizing computational fluid dynamics, and in vitro studies using also 3D printed aortic models. With the role of principal investigator or co-investigator, TARC at PSD has been participating in other several projects, including the International Registry of Acute Aortic Dissection, the International Aortic Arch Surgery Study Group, the European Registry of Endovascular Aortic Repair Complications, the ADSORB and ASSIST trials, and the GREAT registry. International collaborations have included also studies on predictors of aortic growth after dissection with the Yale University and University of Virginia, and on aortic biomarkers with the University of Tokyo.

16.
Am J Surg ; 210(1): 106-10, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25754845

RESUMO

BACKGROUND: In this study, we evaluated long-term survival in patients treated with and without mechanical bowel preparation (MBP) before colorectal surgery for cancer. METHODS: Long-term outcome of patients of 2 main participating hospitals in a prior multicenter randomized trial comparing clinical outcome of MBP versus no MBP was reviewed. Primary endpoint was cancer-related mortality and secondary endpoint was all-cause mortality. RESULTS: A total of 382 patients underwent potentially curative surgery for colorectal cancer. One hundred seventy-seven (46%) patients were treated with MBP and 205 (54%) were not before surgery. Median follow-up was 7.6 years (mean 6.6, range .01 to 12.73). There was no significant difference in both cancer-related mortality and all-cause mortality in patients treated with MBP and without MBP (P = .76 and P = .36, respectively). Multivariate analysis, taking account of age, sex, AJCC cancer stage, and ASA classification, also showed no survival difference. CONCLUSIONS: Our results indicate that MBP does not seem to influence long-term survival in patients surgically treated for colorectal cancer.


Assuntos
Catárticos/uso terapêutico , Neoplasias Colorretais/mortalidade , Neoplasias Colorretais/cirurgia , Cuidados Pré-Operatórios , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Taxa de Sobrevida , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA