RESUMO
Introduction: Tubular biomarkers may shed insight into progression of kidney tubulointerstitial pathology complementary to traditional measures of glomerular function and damage. Methods: We examined trajectories of tubular biomarkers in the Diabetes Control and Complications Trial and the Epidemiology of Diabetes Interventions and Complications Study (DCCT/EDIC Study) of type 1 diabetes (T1D). Biomarkers were measured in a subset of 220 participants across 7 time points over 26 years. Measurements included the following: kidney injury molecule 1 (KIM-1), soluble tumor necrosis factor 1 (sTNFR1) in serum or plasma, epidermal growth factor (EGF), monocyte chemoattractant protein-1 (MCP1) in timed urine, and a composite tubular secretion score. We described biomarker trajectories and examined how these were affected by intensive glucose-lowering therapy and glycemia. Results: At baseline, participants had a mean age of 28 years, 45% were women, and 50% were assigned to intensive glucose-lowering therapy. The mean estimated glomerular filtration rate (eGFR) was 125 ml/min per 1.73 m2 and 90% of participants had a urinary albumin excretion rate (AER) <30 mg/24h. Mean changes in biomarkers over time (percent/decade) were: KIM-1: 27.3% (95% confidence interval [CI]: 21.4-33.5), sTNFR1: 16.9% (14.5-19.3), MCP1: 18.4% (8.9-28.8), EGF: -13.5% (-16.7 to -10.1), EGF-MCP1 ratio: -26.9% (-32.2 to -21.3), and tubular secretion score -0.9% (-1.8 to 0.0), versus -12.0% (CI: -12.9 to -11.1) for eGFR and 10.9% (2.5-20.1) for AER. Intensive versus conventional glucose-lowering therapy was associated with slower increase in sTNFR1 (relative difference in change: 0.94 [0.90-0.98]). Higher HbA1c was associated with faster increases in sTNFR1 (relative difference in change: 1.06 per 1% higher HbA1c [1.05-1.08]) and KIM-1 (1.09 [1.05-1.14]). Conclusion: Among participants with T1D and normal eGFR at baseline, kidney tubular biomarkers changed significantly over long-term follow-up. Hyperglycemia was associated with larger increases in serum or plasma sTNFR1 and KIM-1, when followed-up longitudinally.
RESUMO
OBJECTIVE: Tubulointerstitial injury contributes to diabetic kidney disease (DKD) progression. We tested tubular biomarker associations with DKD development in type 1 diabetes (T1D). RESEARCH DESIGN AND METHODS: We performed a case-cohort study examining associations of tubular biomarkers, measured across seven time points spanning â¼30 years, with incident macroalbuminuria ("severely elevated albuminuria," urinary albumin excretion rate [AER] ≥300 mg/day) and sustained low estimated glomerular filtration rate (eGFR) (persistent eGFR <60 mL/min/1.73 m2) in the Diabetes Control and Complications Trial (DCCT)/Epidemiology of Diabetes Interventions and Complications (EDIC) study. Biomarkers included KIM-1 and sTNFR1 in serum/plasma, MCP-1 and EGF in urine, and a composite tubular secretion score reflecting secreted solute clearance. We assessed biomarkers using single values, as mean values from consecutive time points, and as change over consecutive time points, each as time-updated exposures. RESULTS: At baseline, mean diabetes duration was 5.9 years, with mean HbA1c 8.9%, eGFR 125 mL/min/1.73 m2, and AER 16 mg/day. There were 4.8 and 3.5 cases per 1,000 person-years of macroalbuminuria and low eGFR, respectively. Assessed according to single biomarker values, KIM-1 was associated with risk of subsequent macroalbuminuria and low eGFR (hazard ratio [HR] per 20% higher biomarker 1.11 [95% CI 1.06, 1.16] and 1.12 [1.04, 1.21], respectively) and sTNFR1 was associated with subsequent macroalbuminuria (1.14 [1.03, 1.25]). Mean KIM-1 and EGF-to-MCP-1 ratio were associated with subsequent low eGFR. In slope analyses, increases in KIM-1 and sTNFR1 were associated with subsequent macroalbuminuria (per 20% biomarker increase, HR 1.81 [1.40, 2.34] and 1.95 [1.18, 3.21]) and low eGFR (2.26 [1.65, 3.09] and 2.94 [1.39, 6.23]). CONCLUSIONS: Serial KIM-1 and sTNFR1 are associated with incident macroalbuminuria and sustained low eGFR in T1D.
Assuntos
Albuminúria , Biomarcadores , Nefropatias Diabéticas , Taxa de Filtração Glomerular , Receptor Celular 1 do Vírus da Hepatite A , Humanos , Taxa de Filtração Glomerular/fisiologia , Biomarcadores/sangue , Biomarcadores/urina , Masculino , Feminino , Receptor Celular 1 do Vírus da Hepatite A/metabolismo , Adulto , Nefropatias Diabéticas/epidemiologia , Nefropatias Diabéticas/fisiopatologia , Receptores Tipo I de Fatores de Necrose Tumoral/sangue , Diabetes Mellitus Tipo 1/complicações , Diabetes Mellitus Tipo 1/urina , Túbulos Renais/fisiopatologia , Túbulos Renais/metabolismo , Adulto Jovem , Quimiocina CCL2/urina , Quimiocina CCL2/sangueRESUMO
Efficient recruitment of eligible participants is a significant challenge for clinical research studies. This challenge was exacerbated during the COVID-19 pandemic when in-person recruitment was not an option. In 2020, the University of Minnesota was tasked, as part of the National Cancer Institute's Serological Sciences Network for COVID-19 (SeroNet), to recruit participants for a longitudinal serosurveillance clinical research study with a goal of characterizing the COVID-19 vaccine-elicited immune response among immunocompromised individuals, which necessitated reliance on non-traditional strategies for participant recruitment. To meet our enrollment target of 300 transplant patients, 300 cancer patients, 100 persons living with HIV, and 200 immunocompetent individuals, we utilized targeted electronic health record (EHR)-based recruitment in addition to traditional recruitment tools, which was an effective combination of recruitment strategies. A significant advantage of patient portal messaging or other digital recruitment strategies such as email communication is timing. We reached 85 % (769 out of 900) of our enrollment target within one year with a 14.3 % response rate to invitations to participate in our study. This achievement is perhaps more salient given the COVID-19 pandemic-related constraints within which we were operating. We demonstrated that the EHR can be leveraged to quickly identify potentially eligible study participants either via EHR communication or mail. We also illustrate how the online portal MyChart can be used to efficiently send targeted recruitment messages.
RESUMO
In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies" (https://www.cancer.gov/research/key-initiatives/covid-19/coronavirus-research-initiatives/serological-sciences-network). SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) serology standard reference material and first WHO international standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. SeroNet institutions reported development of a total of 27 enzyme-linked immunosorbent assay (ELISA) methods, 13 multiplex assays, and 9 neutralization assays and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. In conclusion, SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons. IMPORTANCE SeroNet institutions have developed or implemented 61 diverse COVID-19 serological assays and are collaboratively working to harmonize these assays using reference materials to establish standardized reporting units. This will facilitate clinical interpretation of serology results and cross-comparison of research data.
Assuntos
COVID-19 , Anticorpos Antivirais , COVID-19/diagnóstico , Teste para COVID-19 , Humanos , SARS-CoV-2 , Testes Sorológicos/métodosRESUMO
Objective: To investigate longitudinal changes in the blood concentration of fibroblast growth factor 23 (FGF23) from midlife to late life and their major predictors in the general population. Patients and Methods: In 14,444 participants of the Atherosclerosis Risk in Communities Study, we analyzed the association of 31,095 measurements of serum intact FGF23 with age using data from 3 visits (visit 2 [N=13,460; mean age, 57 years]; visit 3 [N=12,323; mean age, 60 years]; and visit 5 [N=6122; mean age, 76 years]) and a linear mixed-effects model. Among 5804 participants who had FGF23 measurements at both visits 3 and 5, we explored predictors of FGF23 change from midlife to late life using linear regression models. Prespecified risk factors were estimated glomerular filtration rate, body mass index, ever smoking, ever drinker, diabetes, hypertension, history of cardiovascular disease, total cholesterol, and high-density lipoprotein cholesterol. Results: Median FGF23 concentrations were 41.9 pg/mL (interquartile interval [IQI], 33.9 to 51.8 pg/mL) at visit 2, 38.3 pg/mL (IQI, 30.6 to 48.3 pg/mL) at visit 3, and 55.0 pg/mL (IQI, 44.4 to 70.3 pg/mL) at visit 5. A linear mixed-effects model showed that the association of FGF23 with age was nonlinear, with a slight decline or no change in age 45-60 years and a monotonic increase in age greater than or equal to 65 years (FGF23, +10 to 15 pg/mL per 10 years of age). In a multivariable linear regression model, significantly greater increases in FGF23 were noted, with midlife estimated glomerular filtration rate less than 60 mL/min per 1.73 m2 vs more than or equal to 60 mL/min per 1.73 m2 (ΔFGF23, +4.4 pg/mL [95% CI, 0.9 to 8.0]), diabetes vs no diabetes (ΔFGF23, +6.2 pg/mL [95% CI, 4.1 to 8.3]), and hypertension vs no hypertension (ΔFGF23, +4.1 pg/mL [95% CI, 2.7 to 5.4]). Conclusion: FGF23 did not show any major changes in midlife but increased linearly in late life. Reduced kidney function, diabetes, and hypertension were robustly associated with a greater increase in FGF23. Further investigations are needed to understand the potential mechanisms linking these conditions to an increase in FGF23 concentrations.
RESUMO
Background: In October 2020, the National Cancer Institute (NCI) Serological Sciences Network (SeroNet) was established to study the immune response to COVID-19, and "to develop, validate, improve, and implement serological testing and associated technologies." SeroNet is comprised of 25 participating research institutions partnering with the Frederick National Laboratory for Cancer Research (FNLCR) and the SeroNet Coordinating Center. Since its inception, SeroNet has supported collaborative development and sharing of COVID-19 serological assay procedures and has set forth plans for assay harmonization. Methods: To facilitate collaboration and procedure sharing, a detailed survey was sent to collate comprehensive assay details and performance metrics on COVID-19 serological assays within SeroNet. In addition, FNLCR established a protocol to calibrate SeroNet serological assays to reference standards, such as the U.S. SARS-CoV-2 serology standard reference material and First WHO International Standard (IS) for anti-SARS-CoV-2 immunoglobulin (20/136), to facilitate harmonization of assay reporting units and cross-comparison of study data. Results: SeroNet institutions reported development of a total of 27 ELISA methods, 13 multiplex assays, 9 neutralization assays, and use of 12 different commercial serological methods. FNLCR developed a standardized protocol for SeroNet institutions to calibrate these diverse serological assays to reference standards. Conclusions: SeroNet institutions have established a diverse array of COVID-19 serological assays to study the immune response to SARS-CoV-2 virus and vaccines. Calibration of SeroNet serological assays to harmonize results reporting will facilitate future pooled data analyses and study cross-comparisons.
RESUMO
CONTEXT.: Use of cystatin C for glomerular filtration rate estimation (eGFR) has garnered heightened interest as a means to avoid race-based medicine, since eGFRcys equations do not require specification of race. Before considering more widespread use of cystatin C, it is important to confirm that assays provide accurate measurements of cystatin C concentration, to ensure accurate GFR estimates. OBJECTIVE.: To determine if the accuracy of cystatin C measurements in laboratories participating in the College of American Pathologists (CAP) Cystatin C (CYS) survey has improved since 2014. DESIGN.: Two fresh frozen serum pools, the first from healthy donors without chronic kidney disease (CKD), and the second from patients with CKD, along with a synthetically prepared elevated cystatin C pool, were sent to laboratories participating in the 2019 CYS-A survey. Target values were established by using 2 immunoassays and a bracketed 2-point calibration with diluted ERM-DA471/IFCC reference material. RESULTS.: For the healthy donor fresh frozen pool (ERM-DA471/IFCC-traceable target of 0.725 mg/L), the all-method mean (standard deviation, coefficient of variation) was 0.731 mg/L (0.071, 9.7%). For the CKD pool (ERM-DA471/IFCC-traceable target of 2.136 mg/L), the all-method mean was 2.155 mg/L (0.182, 8.4%). For the synthetically spiked pool (ERM-DA471/IFCC-traceable target of 1.843 mg/L), the all-method mean was 1.886 mg/L (0.152, 8.1%). This represents marked improvement in accuracy and between-method agreement compared to the 2014 CAP survey. CONCLUSIONS.: Manufacturers have markedly improved accuracy and between-method agreement of cystatin C measurement procedures since 2014, which allows for greater confidence in estimated GFR relying on cystatin C.
Assuntos
Cistatina C , Insuficiência Renal Crônica , Creatinina , Taxa de Filtração Glomerular , Humanos , Laboratórios , Patologistas , Insuficiência Renal Crônica/diagnósticoRESUMO
BACKGROUND: Current equations for estimated glomerular filtration rate (eGFR) that use serum creatinine or cystatin C incorporate age, sex, and race to estimate measured GFR. However, race in eGFR equations is a social and not a biologic construct. METHODS: We developed new eGFR equations without race using data from two development data sets: 10 studies (8254 participants, 31.5% Black) for serum creatinine and 13 studies (5352 participants, 39.7% Black) for both serum creatinine and cystatin C. In a validation data set of 12 studies (4050 participants, 14.3% Black), we compared the accuracy of new eGFR equations to measured GFR. We projected the prevalence of chronic kidney disease (CKD) and GFR stages in a sample of U.S. adults, using current and new equations. RESULTS: In the validation data set, the current creatinine equation that uses age, sex, and race overestimated measured GFR in Blacks (median, 3.7 ml per minute per 1.73 m2 of body-surface area; 95% confidence interval [CI], 1.8 to 5.4) and to a lesser degree in non-Blacks (median, 0.5 ml per minute per 1.73 m2; 95% CI, 0.0 to 0.9). When the adjustment for Black race was omitted from the current eGFR equation, measured GFR in Blacks was underestimated (median, 7.1 ml per minute per 1.73 m2; 95% CI, 5.9 to 8.8). A new equation using age and sex and omitting race underestimated measured GFR in Blacks (median, 3.6 ml per minute per 1.73 m2; 95% CI, 1.8 to 5.5) and overestimated measured GFR in non-Blacks (median, 3.9 ml per minute per 1.73 m2; 95% CI, 3.4 to 4.4). For all equations, 85% or more of the eGFRs for Blacks and non-Blacks were within 30% of measured GFR. New creatinine-cystatin C equations without race were more accurate than new creatinine equations, with smaller differences between race groups. As compared with the current creatinine equation, the new creatinine equations, but not the new creatinine-cystatin C equations, increased population estimates of CKD prevalence among Blacks and yielded similar or lower prevalence among non-Blacks. CONCLUSIONS: New eGFR equations that incorporate creatinine and cystatin C but omit race are more accurate and led to smaller differences between Black participants and non-Black participants than new equations without race with either creatinine or cystatin C alone. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases.).
Assuntos
Creatinina/sangue , Cistatina C/sangue , Taxa de Filtração Glomerular , Grupos Raciais , Insuficiência Renal Crônica/etnologia , Adulto , Idoso , Algoritmos , População Negra , Conjuntos de Dados como Assunto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/epidemiologia , Insuficiência Renal Crônica/fisiopatologia , Estados Unidos/epidemiologiaRESUMO
INTRODUCTION: The creatinine-based Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) estimated glomerular filtration rate (eGFR) equation was calibrated for the general Pakistan population (eGFRcr-PK) to eliminate bias and improve accuracy. Cystatin C-based CKD-EPI equations (eGFRcys and eGFRcr-cys) have not been assessed in this population, and non-GFR determinants of cystatin C are unknown. METHODS: We assessed eGFRcys, eGFRcr-cys, and non-GFR determinants of cystatin C in a cross-sectional study of 557 participants (≥40 years of age) from Pakistan. We compared bias (median difference in measured GFR [mGFR] and eGFR), precision (interquartile range [IQR] of differences), accuracy (percentage of eGFR within 30% of mGFR), root mean square error (RMSE), and classification of mGFR <60 ml/min/1.73 m2 (area under the receiver operating characteristic curve [AUC] and net reclassification index [NRI]) among eGFR equations. RESULTS: We found that eGFRcys underestimated mGFR (bias, 12.7 ml/min/1.73 m2 [95% confidence interval {CI} 10.7-15.2]). eGFRcr-cys did not improve performance over eGFRcr-PK in precision (P = 0.52), accuracy (P = 0.58), or RMSE (P = 0.49). Results were consistent among subgroups by age, sex, smoking, body mass index (BMI), and eGFR. NRI was 7.31% (95% CI 1.52%-13.1%; P < 0.001) for eGFRcr-cys versus eGFRcr-PK, but AUC was not improved (0.92 [95% CI 0.87-0.96] vs. 0.90 [95% CI 0.86-0.95]; P = 0.056). Non-GFR determinants of higher cystatin C included male sex, smoking, higher BMI and total body fat, and lower lean body mass. CONCLUSION: eGFRcys underestimated mGFR in South Asians and eGFRcr-cys did not offer substantial advantage compared with eGFRcr-PK. Future studies are warranted to better understand the large bias in eGFRcys and non-GFR determinants of cystatin C in South Asians.
RESUMO
BACKGROUND: Lipoprotein (a) [Lp(a)] is a risk factor for coronary heart disease and calcific aortic valve disease. We determined the relationships of Lp(a) with prevalence and progression of coronary artery calcification (CAC), mitral annular calcification (MAC), and thoracic aortic calcification (TAC) in a multi-ethnic cohort of middle to older-aged adults. METHODS: This analysis included 6705 Multi-Ethnic Study of Atherosclerosis participants. Lp(a) was measured with a turbidimetric immunoassay. CAC, MAC, and TAC were assessed by cardiac computed tomography both at baseline and once during follow-up. RESULTS: In adjusted relative risk regression cross-sectional analysis, a Lp(a) level ≥50 âmg/dL was associated with a 22% higher prevalence of MAC (relative risk (RR) â= â1.22, 95% confidence interval (CI) 1.00, 1.49). No significant associations were observed for prevalent CAC or TAC. In adjusted prospective analyses, participants with Lp(a) ≥50 âmg/dL were at significantly higher risk for rapid CAC progression (median follow-up â= â8.9 years), defined as ≥100 units/year, compared to those with lower Lp(a) levels (RR â= â1.67, 95% CI â= â1.23, 2.27). The association between higher Lp(a) levels and incident CHD was no longer significant after adjusting for CAC progression. No significant associations were observed for MAC or TAC progression (median follow-up â= â2.6 years). CONCLUSIONS: Higher Lp(a) levels are associated with more rapid CAC progression. Additional study is needed to better understand how this relationship can further improve the ability of Lp(a) to enhance cardiovascular disease risk prediction.
Assuntos
Aorta Torácica , Doenças da Aorta/sangue , Calcinose/sangue , Doença da Artéria Coronariana/sangue , Doenças das Valvas Cardíacas/sangue , Lipoproteína(a)/sangue , Valva Mitral , Calcificação Vascular/sangue , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/etnologia , Biomarcadores/sangue , Calcinose/diagnóstico por imagem , Calcinose/etnologia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/etnologia , Estudos Transversais , Feminino , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/etnologia , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Prevalência , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Estados Unidos/epidemiologia , Calcificação Vascular/diagnóstico por imagem , Calcificação Vascular/etnologiaRESUMO
RATIONALE AND OBJECTIVE: Glomerular filtration rate (GFR) estimation based on creatinine and cystatin C (eGFRcr-cys) is more accurate than estimated GFR (eGFR) based on creatinine or cystatin C alone (eGFRcr or eGFRcys, respectively), but the inclusion of creatinine in eGFRcr-cys requires specification of a person's race. ß2-Microglobulin (B2M) and ß-trace protein (BTP) are alternative filtration markers that appear to be less influenced by race than creatinine is. STUDY DESIGN: Study of diagnostic test accuracy. SETTING AND PARTICIPANTS: Development in a pooled population of 7 studies with 5,017 participants with and without chronic kidney disease. External validation in a pooled population of 7 other studies with 2,245 participants. TESTS COMPARED: Panel eGFR using B2M and BTP in addition to cystatin C (3-marker panel) or creatinine and cystatin C (4-marker panel) with and without age and sex or race. OUTCOMES: GFR measured as the urinary clearance of iothalamate, plasma clearance of iohexol, or plasma clearance of [51Cr]EDTA. RESULTS: Mean measured GFRs were 58.1 and 83.2 mL/min/1.73 m2, and the proportions of Black participants were 38.6% and 24.0%, in the development and validation populations, respectively. In development, addition of age and sex improved the performance of all equations compared with equations without age and sex, but addition of race did not further improve the performance. In validation, the 4-marker panels were more accurate than the 3-marker panels (P < 0.001). The 3-marker panel without race was more accurate than eGFRcys (percentage of estimates greater than 30% different from measured GFR [1 - P30] of 15.6% vs 17.4%; P = 0.01), and the 4-marker panel without race was as accurate as eGFRcr-cys (1 - P30 of 8.6% vs 9.4%; P = 0.2). Results were generally consistent across subgroups. LIMITATIONS: No representation of participants with severe comorbid illness and from geographic areas outside of North America and Europe. CONCLUSIONS: The 4-marker panel eGFR is as accurate as eGFRcr-cys without requiring specification of race. A more accurate race-free eGFR could be an important advance.
Assuntos
Negro ou Afro-Americano , Creatinina/metabolismo , Cistatina C/metabolismo , Taxa de Filtração Glomerular , Oxirredutases Intramoleculares/metabolismo , Lipocalinas/metabolismo , Insuficiência Renal Crônica/diagnóstico , População Branca , Microglobulina beta-2/metabolismo , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , População Negra , Estudos de Casos e Controles , Radioisótopos de Cromo , Ácido Edético , Feminino , Humanos , Iohexol , Ácido Iotalâmico , Masculino , Pessoa de Meia-Idade , Insuficiência Renal Crônica/etnologia , Insuficiência Renal Crônica/metabolismo , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Adulto JovemRESUMO
BACKGROUND: Establishment and improvement of glomerular filtration rate estimating equations requires accurate and precise laboratory measurement procedures (MPs) for filtration markers. The Advanced Research and Diagnostic Laboratory (ARDL) at the University of Minnesota, which has served as the central laboratory for the Chronic Kidney Disease Epidemiology Collaboration since 2009, has implemented several quality assurance measures to monitor the accuracy and stability of filtration marker assays over time. METHODS: To assess longitudinal stability for filtration marker assays, a 40-sample calibration panel was created using pooled serum, divided into multiple frozen aliquots stored at -80 °C. ARDL monitored 4 markers-creatinine, cystatin C, beta-2-microglobulin (B2M) and beta-trace protein-measuring 15 calibration panel aliquots from 2009 to 2019. Initial target values were established using the mean of the first 3 measurements performed in 2009-10, and differences from target were monitored over time. New MPs for cystatin C and B2M were added in 2012, with target values established using the first measurement. RESULTS: The mean percentage difference from mean target values across time was <2% for all original MPs (-0.59% for creatinine; -0.94% for cystatin C; -0.82% for B2M; 1.24% for beta-trace protein). CONCLUSIONS: Close monitoring of filtration marker trends with a calibration panel at ARDL demonstrates remarkable long-term stability of the MPs. Routine use of a calibration panel for both research studies and clinical care is recommended for filtration markers where longitudinal monitoring is important to detect analytical biases, which can mask or confound true clinical trends in patients.
Assuntos
Taxa de Filtração Glomerular , Falência Renal Crônica/fisiopatologia , Biomarcadores/metabolismo , Creatinina/sangue , Cistatina C/sangue , Feminino , Humanos , Oxirredutases Intramoleculares/sangue , Falência Renal Crônica/metabolismo , Lipocalinas/sangue , Masculino , Pessoa de Meia-Idade , Microglobulina beta-2/sangueRESUMO
RATIONALE & OBJECTIVES: Estimated glomerular filtration rate (eGFR) using creatinine and cystatin C (eGFRcr-cys) may be less accurate compared to measured GFR (mGFR) in China than in North America, Europe, and Australia due to variation across regions in their non-GFR determinants. The non-GFR determinants of ß2-microglobulin (B2M) and ß-trace protein (BTP) differ from those of creatinine and cystatin C. Thus, the average eGFR using all 4 markers (eGFRavg) could be more accurate than eGFRcr-cys in China. STUDY DESIGN: Diagnostic test study. SETTING & PARTICIPANTS: 1,066 participants in Shanghai and Beijing with creatinine and cystatin C and 666 participants with all 4 filtration markers. TESTS COMPARED: Index tests were previously developed equations for eGFR using creatinine, cystatin C, B2M, and BTP and combinations. The reference test was mGFR using plasma clearance of iohexol. We compared the performance of eGFRavg to eGFRcr-cys using the proportion of participants with errors in eGFR >30% of mGFR (1 - P30) and root mean square error (RMSE) of the regression of eGFR on mGFR on the logarithmic scale. We also compared classification and reclassification of mGFR categories using eGFRavg compared to eGFRcr-cys. OUTCOMES: Accuracy was significantly better for eGFRavg (1 - P30 of 10.4% and RMSE of 0.214) compared to eGFRcr-cys (1 - P30 of 13.8% and RMSE of 0.232; P = 0.004 and P = 0.006, respectively). However, improvements in accuracy did not generally translate into significant improvement in classification or reclassification of mGFR categories. LIMITATIONS: Study population may not be generalizable to clinical settings other than large urban medical centers in China. CONCLUSIONS: A panel of endogenous filtration markers including B2M and BTP in addition to creatinine and cystatin C may improve GFR estimation in China. Further study is necessary to determine whether GFR estimation using B2M and BTP can be improved and whether these improvements lead to useful clinical applications.
RESUMO
BACKGROUND: Higher serum urate levels are associated with an increased risk of diabetic kidney disease. Lowering of the serum urate level with allopurinol may slow the decrease in the glomerular filtration rate (GFR) in persons with type 1 diabetes and early-to-moderate diabetic kidney disease. METHODS: In a double-blind trial, we randomly assigned participants with type 1 diabetes, a serum urate level of at least 4.5 mg per deciliter, an estimated GFR of 40.0 to 99.9 ml per minute per 1.73 m2 of body-surface area, and evidence of diabetic kidney disease to receive allopurinol or placebo. The primary outcome was the baseline-adjusted GFR, as measured with iohexol, after 3 years plus a 2-month washout period. Secondary outcomes included the decrease in the iohexol-based GFR per year and the urinary albumin excretion rate after washout. Safety was also assessed. RESULTS: A total of 267 patients were assigned to receive allopurinol and 263 to receive placebo. The mean age was 51.1 years, the mean duration of diabetes 34.6 years, and the mean glycated hemoglobin level 8.2%. The mean baseline iohexol-based GFR was 68.7 ml per minute per 1.73 m2 in the allopurinol group and 67.3 ml per minute per 1.73 m2 in the placebo group. During the intervention period, the mean serum urate level decreased from 6.1 to 3.9 mg per deciliter with allopurinol and remained at 6.1 mg per deciliter with placebo. After washout, the between-group difference in the mean iohexol-based GFR was 0.001 ml per minute per 1.73 m2 (95% confidence interval [CI], -1.9 to 1.9; P = 0.99). The mean decrease in the iohexol-based GFR was -3.0 ml per minute per 1.73 m2 per year with allopurinol and -2.5 ml per minute per 1.73 m2 per year with placebo (between-group difference, -0.6 ml per minute per 1.73 m2 per year; 95% CI, -1.5 to 0.4). The mean urinary albumin excretion rate after washout was 40% (95% CI, 0 to 80) higher with allopurinol than with placebo. The frequency of serious adverse events was similar in the two groups. CONCLUSIONS: We found no evidence of clinically meaningful benefits of serum urate reduction with allopurinol on kidney outcomes among patients with type 1 diabetes and early-to-moderate diabetic kidney disease. (Funded by the National Institute of Diabetes and Digestive and Kidney Diseases and others; PERL ClinicalTrials.gov number, NCT02017171.).
Assuntos
Alopurinol/uso terapêutico , Diabetes Mellitus Tipo 1/tratamento farmacológico , Nefropatias Diabéticas/prevenção & controle , Inibidores Enzimáticos/uso terapêutico , Taxa de Filtração Glomerular/efeitos dos fármacos , Ácido Úrico/sangue , Xantina Oxidase/antagonistas & inibidores , Adulto , Idoso , Alopurinol/efeitos adversos , Diabetes Mellitus Tipo 1/sangue , Diabetes Mellitus Tipo 1/fisiopatologia , Método Duplo-Cego , Inibidores Enzimáticos/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema Renina-Angiotensina , Falha de TratamentoAssuntos
Fibrilação Atrial/sangue , Fibrilação Atrial/etnologia , Lipoproteína(a)/sangue , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/prevenção & controle , Biomarcadores/sangue , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Estados Unidos/epidemiologia , Regulação para CimaRESUMO
BACKGROUND: International Society for Peritoneal Dialysis guidelines recommend to routinely monitor the total measured clearance (mCl) of small solutes such as creatinine; however, collection of 24-h urine and peritoneal dialysis (PD) fluid is burdensome to patients and prone to errors. We hypothesized that equations could be developed to estimate mCl (estimated clearance (eCl)) using endogenous filtration markers. METHODS: In the Guangzhou PD Study (n = 980), we developed eCl equations using linear regression in two-third and validated them in the remaining one-third. Reference tests were mCl for urea nitrogen (UN) (mClUN, ml/min) and average mCl for UN and creatinine (mClUN-cr, ml/min/1.73 m2). Index tests were various eCl equations using UN, creatinine, low-molecular-weight proteins (LMWPs) (beta-trace protein (BTP), beta-2 microglobulin (B2M), and cystatin C), demographic variables, and body size. After reexpression of the equations in the combined data set, we analyzed accuracy (eCl within ± 2.0 units of mCl) and the predictive value of eCl to detect a weekly total standard Kt/V (weekly mClUN indexed for total body water) > 1.7 using receiver operating characteristic curve. RESULTS: Mean age of the cohort was 50 ± 15 years, 53% were male; mClUN was 6.9 ± 1.8 and mClUN-cr was 7.5 ± 2.8. Creatinine but not UN contributed to eCl for both mCl. LMWP did not improve accuracy for mClUN (range 88-89%). BTP and B2M improved the accuracy for mClUN-cr (82% vs. 80%); however, differences were small. The area under the curve for predicting a weekly Kt/V > 1.7 was similar for all equations (range 0.79-0.80). CONCLUSIONS: Total small solute clearance can be estimated moderately well in continuous ambulatory PD patients using serum creatinine and demographic variables without urine and dialysate collection.
Assuntos
Creatinina/metabolismo , Soluções para Diálise/metabolismo , Falência Renal Crônica/metabolismo , Falência Renal Crônica/terapia , Diálise Peritoneal Ambulatorial Contínua , Adulto , Idoso , Biomarcadores/metabolismo , Nitrogênio da Ureia Sanguínea , China , Estudos de Coortes , Estudos Transversais , Feminino , Taxa de Filtração Glomerular , Humanos , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Curva ROCRESUMO
RATIONALE & OBJECTIVE: Glomerular filtration rate (GFR) estimation based on creatinine or cystatin C level is currently the standard method for assessing GFR in epidemiologic research and clinical trials despite several important and well-known limitations. Plasma iohexol clearance has been proposed as an inexpensive method for measuring GFR that could replace estimated GFR in many research projects. However, lack of standardization for iohexol assays and the use of different protocols such as single- and multiple-sample methods could potentially hamper comparisons across studies. We compared iohexol assays and GFR measurement protocols in 3 population-based European cohorts. STUDY DESIGN: Cross-sectional investigation. SETTING & PARTICIPANTS: Participants in the Age, Gene/Environment Susceptibility-Kidney Study (AGES-Kidney; n=805), the Berlin Initiative Study (BIS, n=570), and the Renal Iohexol Clearance Survey Follow-up Study (RENIS-FU; n=1,324). TESTS COMPARED: High-performance liquid chromatography analyses of iohexol. Plasma iohexol clearance calculated using single- versus multiple-sample protocols. OUTCOMES: Measures of agreement between methods. RESULTS: Frozen samples from the 3 studies were obtained and iohexol concentrations were remeasured in the laboratory at the University Hospital of North Norway. Lin's concordance correlation coefficient ρ was>0.96 and Cb (accuracy) was>0.99 for remeasured versus original serum iohexol concentrations in all 3 cohorts, and Passing-Bablok regression did not find differences between measurements, except for a slope of 1.025 (95% CI, 1.006-1.046) for the log-transformed AGES-Kidney measurements. The multiple-sample iohexol clearance measurements in AGES-Kidney and BIS were compared with single-sample GFRs derived from the same iohexol measurements. Mean bias for multiple-sample relative to single-sample GFRs in AGES-Kidney and BIS were-0.25 and-0.15mL/min, and 99% and 97% of absolute differences were within 10% of the multiple-sample result, respectively. LIMITATIONS: Lack of comparison with an independent gold-standard method. CONCLUSIONS: Agreement between the iohexol assays and clearance protocols in the 3 investigated cohorts was substantial. Our findings indicate that plasma iohexol clearance measurements can be compared across these studies.