Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
J Thorac Imaging ; 39(3): 178-184, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-37423613

RESUMO

PURPOSE: To compare dual-energy computed tomography (DECT) based qualitative and quantitative parameters in chronic thromboembolic pulmonary hypertension with various postoperative primary and secondary endpoints. MATERIALS AND METHODS: This was a retrospective analysis of 64 patients with chronic thromboembolic pulmonary hypertension who underwent DECT. First, a clot score was calculated by assigning the following score: pulmonary trunk-5, each main pulmonary artery-4, each lobar-3, each segmental-2, and subsegmental-1 per lobe; the sum total was then calculated. The perfusion defect (PD) score was calculated by assigning 1 point to each segmental PD. The combined score was calculated by adding clot and PD scores. For quantitative evaluation, we calculated perfused blood volume (PBV) (%) of each lung and the sum of both lungs. Primary endpoints included testing association between combined score and total PBV with change in mean pulmonary arterial pressure ([mPAP], change calculated as preop minus postop values). Secondary endpoints included explorative analysis of the correlation between combined score and PBV with change in preoperative and postoperative pulmonary vascular resistance, change in preoperative 6-minute walk distance (6MWD), and immediate postoperative complications such as reperfusion edema, ECMO placement, stroke, death and mechanical ventilation for more than 48 hours, all within 1 month of surgery. RESULTS: Higher combined scores were associated with larger decreases in mPAP ( =0.27, P =0.036). On average, the decrease in mPAP (pre mPAP-post mPAP) increased by 2.2 mm Hg (95% CI: -0.6, 5.0) with each 10 unit increase in combined score. The correlation between total PBV and change in mPAP was small and not statistically significant. During an exploratory analysis, higher combined scores were associated with larger increases in 6MWD at 6 months postprocedure ( =0.55, P =0.002). CONCLUSION: Calculation of DECT-based combined score offers potential in the evaluation of hemodynamic response to surgery. This response can also be objectively quantified.

2.
J Appl Clin Med Phys ; 25(1): e14235, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38059633

RESUMO

PURPOSE: The purpose of this investigation was to assess the effect of visceral adipose tissue volume (VA) on reader efficacy in diagnosing and characterizing small bowel Crohn's disease using lower exposure CT enterography (CTE). Secondarily, we investigated the effect of lower exposure and VA on reader diagnostic confidence. METHODS: Prospective paired investigation of 256 CTE, 129 with Crohn's disease, were reconstructed at 100% and simulated 50% and 30% exposure. The senior author provided the disease classification for the 129 patients with Crohn's disease. Patient VA was measured, and exams were evaluated by six readers for presence or absence of Crohn's disease and phenotype using a 0-10-point scale. Logistic regression models assessed the effect of VA on sensitivity and specificity. RESULTS: The effect of VA on sensitivity was significantly reduced at 30% exposure (odds radio [OR]: 1.00) compared to 100% exposure (OR: 1.12) (p = 0.048). There was no statistically significant difference among the exposures with respect to the effect of visceral fat on specificity (p = 0.159). The study readers' probability of agreement with the senior author on disease classification was 60%, 56%, and 53% at 100%, 50%, and 30% exposure, respectively (p = 0.004). When detecting low severity Crohn's disease, readers' mean sensitivity was 83%, 75%, and 74% at 100%, 50%, and 30% exposure, respectively (p = 0.002). In low severity disease, sensitivity also tended to increase as visceral fat increased (ORs per 1000 cm3 increase in visceral fat: 1.32, 1.31, and 1.18, p = 0.010, 0.016, and 0.100, at 100%, 50%, and 30% exposure). CONCLUSIONS: While the interaction is complex, VA plays a role in detecting and characterizing small bowel Crohn's disease when exposure is altered, particularly in low severity disease.


Assuntos
Doença de Crohn , Enteropatias , Humanos , Doença de Crohn/diagnóstico por imagem , Gordura Intra-Abdominal/diagnóstico por imagem , Estudos Prospectivos , Tomografia Computadorizada por Raios X/métodos
3.
J Appl Clin Med Phys ; 22(2): 138-144, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33368998

RESUMO

PURPOSE: The purpose of this study was to assess the effect of obesity and iterative reconstruction on the ability to reduce exposure by studying the accuracy for detection of low-contrast low-attenuation (LCLA) liver lesions on computed tomography (CT) using a phantom model. METHODS: A phantom with four unique LCLA liver lesions (5- to 15-mm spheres, -24 to -6 HU relative to 90-HU background) was scanned without ("thin" phantom) and with ("obese" phantom) a 5-cm thick fat-attenuation ring at 150 mAs (thin phantom) and 450 mAs (obese phantom) standard exposures and at 33% and 67% exposure reductions. Images were reconstructed using standard filtered back projection (FBP) and with iterative reconstruction (Adaptive Model-Based Iterative Reconstruction strength 3, ADMIRE). A noninferiority analysis of lesion detection was performed. RESULTS: Mean area under the curve (AUC) values for lesion detection were significantly higher for the thin phantom than for the obese phantom regardless of exposure level (P < 0.05) for both FBP and ADMIRE. At 33% exposure reduction, AUC was noninferior for both FBP and ADMIRE strength 3 (P < 0.0001). At 67% exposure reduction, AUC remained noninferior for the thin phantom (P < 0.0035), but was no longer noninferior for the obese phantom (P ≥ 0.7353). There were no statistically significant differences in AUC between FBP and ADMIRE at any exposure level for either phantom. CONCLUSIONS: Accuracy for lesion detection was not only significantly lower in the obese phantom at all relative exposures, but detection accuracy decreased sooner while reducing the exposure in the obese phantom. There was no significant difference in lesion detection between FBP and ADMIRE at equivalent exposure levels for either phantom.


Assuntos
Algoritmos , Neoplasias Hepáticas , Humanos , Obesidade , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
4.
Skeletal Radiol ; 49(7): 1073-1080, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31996983

RESUMO

OBJECTIVE: To determine whether a 3D magnetic resonance imaging (MRI) sequence with postprocessing applied to simulate computed tomography (CT) ("pseudo-CT") images can be used instead of CT to measure acetabular version and alpha angles and to plan for surgery in patients with femoroacetabular impingement (FAI). MATERIALS AND METHODS: Four readers retrospectively measured acetabular version and alpha angles on MRI and CT images of 40 hips from 20 consecutive patients (9 female patients, 11 male patients; mean age, 26.0 ± 6.5 years) with FAI. 3D models created from MRI and CT images were assessed by 2 orthopedic surgeons to determine the need for femoroplasty and/or acetabuloplasty. Interchangeability of MRI with CT was tested by comparing agreement between 2 readers using CT (intramodality) with agreement between 1 reader using CT and 1 using MRI (intermodality). RESULTS: Intramodality and intermodality agreement values were nearly identical for acetabular version and alpha angle measurements and for surgical planning. Increases in inter-reader disagreement for acetabular version angle, alpha angle, and surgical planning when MRI was substituted for CT were - 2.1% (95% confidence interval [CI], - 7.7 to + 3.5%; p = 0.459), - 0.6% (95% CI, - 8.6 to + 7.3%; p = 0.878), and 0% (95% CI, - 15.1 to + 15.1%; p = 1.0), respectively, when an agreement criterion ≤ 5° was used for angle measurements. CONCLUSION: Pseudo-CT MRI was interchangeable with CT for measuring acetabular version and highly favorable for interchangeability for measuring alpha angle and for surgical planning, suggesting that MRI could replace CT in assessing patients with FAI.


Assuntos
Impacto Femoroacetabular/diagnóstico por imagem , Impacto Femoroacetabular/cirurgia , Imageamento Tridimensional , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Período Pré-Operatório , Estudos Retrospectivos
5.
Eur Radiol ; 27(8): 3283-3289, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28091793

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the impact of attenuation-based kilovoltage (kV) pair selection in dual source dual energy (DSDE)-pulmonary embolism (PE) protocol examinations on radiation dose savings and image quality. METHODS: A prospective study was carried out on 118 patients with suspected PE. In patients in whom attenuation-based kV pair selection selected the 80/140Sn kV pair, the pre-scan 100/140Sn CTDIvol (computed tomography dose index volume) values were compared with the pre-scan 80/140Sn CTDIvol values. Subjective and objective image quality parameters were assessed. RESULTS: Attenuation-based kV pair selection switched to the 80/140Sn kV pair ("switched" cohort) in 63 out of 118 patients (53%). The mean 100/140Sn pre-scan CTDIvol was 8.8 mGy, while the mean 80/140Sn pre-scan CTDIvol was 7.5 mGy. The average estimated dose reduction for the "switched" cohort was 1.3 mGy (95% CI 1.2, 1.4; p < 0.001), representing a 15% reduction in dose. After adjusting for patient weight, mean attenuation was significantly higher in the "switched" vs. "non-switched" cohorts in all five pulmonary arteries and in all lobes on iodine maps. CONCLUSIONS: This study demonstrates that attenuation-based kV pair selection in DSDE examination is feasible and can offer radiation dose reduction without compromising image quality. KEY POINTS: • Attenuation-based kV pair selection in dual energy examination is feasible. • It can offer radiation dose reduction to approximately 50% of patients. • Approximate 15% reduction in radiation dose was achieved using this technique. • The image quality is not compromised by use of attenuation-based kV pair selection.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/normas , Embolia Pulmonar/diagnóstico por imagem , Doses de Radiação , Radiografia Torácica/métodos , Radiografia Torácica/normas , Adulto , Idoso , Peso Corporal , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Artéria Pulmonar/diagnóstico por imagem
6.
Radiology ; 280(2): 436-45, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-27077382

RESUMO

Purpose To compare the diagnostic accuracy and image quality of computed tomographic (CT) enterographic images obtained at half dose and reconstructed with filtered back projection (FBP) and sinogram-affirmed iterative reconstruction (SAFIRE) with those of full-dose CT enterographic images reconstructed with FBP for active inflammatory terminal or neoterminal ileal Crohn disease. Materials and Methods This retrospective study was compliant with HIPAA and approved by the institutional review board. The requirement to obtain informed consent was waived. Ninety subjects (45 with active terminal ileal Crohn disease and 45 without Crohn disease) underwent CT enterography with a dual-source CT unit. The reference standard for confirmation of active Crohn disease was active terminal ileal Crohn disease based on ileocolonoscopy or established Crohn disease and imaging features of active terminal ileal Crohn disease. Data from both tubes were reconstructed with FBP (100% exposure); data from the primary tube (50% exposure) were reconstructed with FBP and SAFIRE strengths 3 and 4, yielding four datasets per CT enterographic examination. The mean volume CT dose index (CTDIvol) and size-specific dose estimate (SSDE) at full dose were 13.1 mGy (median, 7.36 mGy) and 15.9 mGy (median, 13.06 mGy), respectively, and those at half dose were 6.55 mGy (median, 3.68 mGy) and 7.95 mGy (median, 6.5 mGy). Images were subjectively evaluated by eight radiologists for quality and diagnostic confidence for Crohn disease. Areas under the receiver operating characteristic curves (AUCs) were estimated, and the multireader, multicase analysis of variance method was used to compare reconstruction methods on the basis of a noninferiority margin of 0.05. Results The mean AUCs with half-dose scans (FBP, 0.908; SAFIRE 3, 0.935; SAFIRE 4, 0.924) were noninferior to the mean AUC with full-dose FBP scans (0.908; P < .003). The proportion of images with inferior quality was significantly higher with all half-dose reconstructions than with full-dose FBP (mean proportion: 0.117 for half-dose FBP, 0.054 for half-dose SAFIRE 3, 0.054 for half-dose SAFIRE 4, and 0.017 for full-dose FBP; P < .001). Conclusion The diagnostic accuracy of half-dose CT enterography with FBP and SAFIRE is statistically noninferior to that of full-dose CT enterography for active inflammatory terminal ileal Crohn disease, despite an inferior subjective image quality. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Doença de Crohn/diagnóstico por imagem , Ileíte/diagnóstico por imagem , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Adulto , Doença de Crohn/complicações , Feminino , Trato Gastrointestinal/diagnóstico por imagem , Humanos , Ileíte/complicações , Íleo/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
7.
Radiology ; 280(2): 475-82, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-26937709

RESUMO

Purpose To assess image noise, contrast-to-noise ratio (CNR) and detectability of low-contrast, low-attenuation liver lesions in a semianthropomorphic phantom by using either a discrete circuit (DC) detector and filtered back projection (FBP) or an integrated circuit (IC) detector and iterative reconstruction (IR) with changes in radiation exposure and phantom size. Materials and Methods An anthropomorphic phantom without or with a 5-cm-thick fat-mimicking ring (widths, 30 and 40 cm) containing liver inserts with four spherical lesions was scanned with five exposure settings on each of two computed tomography scanners, one equipped with a DC detector and the other with an IC detector. Images from the DC and IC detector scanners were reconstructed with FBP and IR, respectively. Image noise and lesion CNR were measured. Four radiologists evaluated lesion presence on a five-point diagnostic confidence scale. Data analyses included receiver operating characteristic (ROC) curve analysis and noninferiority analysis. Results The combination of IC and IR significantly reduced image noise (P < .001) (with the greatest reduction in the 40-cm phantom and at lower exposures) and improved lesion CNR (P < .001). There was no significant difference in area under the ROC curve between detector-reconstruction combinations at fixed exposure for either phantom. Reader accuracy with IC-IR was noninferior at 50% (100 mAs [effective]) and 25% (300 mAs [effective]) exposure reduction for the 30- and 40-cm phantoms, respectively (adjusted P < .001 and .04 respectively). IC-IR improved readers' confidence in the presence of a lesion (P = .029) independent of phantom size or exposure level. Conclusion IC-IR improved objective image quality and lesion detection confidence but did not result in superior diagnostic accuracy when compared with DC-FBP. Moderate exposure reductions maintained comparable diagnostic accuracy for both detector-reconstruction combinations. Lesion detection in the 40-cm phantom was inferior at smaller exposure reduction than in the 30-cm phantom. (©) RSNA, 2016 Online supplemental material is available for this article.


Assuntos
Artefatos , Fígado/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Imagens de Fantasmas , Exposição à Radiação/estatística & dados numéricos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Humanos , Tomografia Computadorizada Multidetectores/estatística & dados numéricos , Doses de Radiação , Razão Sinal-Ruído
8.
Radiology ; 272(1): 154-63, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24620913

RESUMO

PURPOSE: To measure the effect of reduced radiation exposure on low-contrast low-attenuation liver lesion detection in an anthropomorphic abdominal phantom by using filtered back projection (FBP) and sinogram-affirmed iterative reconstruction. MATERIALS AND METHODS: Eighteen radiologists blinded to phantom and study design interpreted randomized image data sets that contained 36 spherical simulated liver lesions of three sizes and three attenuation differences (5-mm diameter: 12, 18, and 24 HU less than the 90-HU background attenuation of the simulated liver insert; 10- and 15-mm diameter: 6, 12, and 18 HU less than the 90-HU background attenuation) scanned with four discrete exposure settings and reconstructed by using FBP and sinogram-affirmed iterative reconstruction. Response assessment included region-level lesion presence or absence on a five-point diagnostic confidence scale. Statistical evaluation included multireader multicase receiver operating characteristic curve analysis, with nonparametric methods and noninferiority analysis at a margin of -0.10. RESULTS: Pooled accuracy at 75% exposure for both FBP and sinogram-affirmed iterative reconstruction was noninferior to 100% exposure (P = .002 and P < .001, respectively). Subsequent exposure reductions resulted in a significant decrease in accuracy. When the smallest (5-mm-diameter) lesions were excluded from analysis, sinogram-affirmed iterative reconstruction was superior to FBP at 100% exposure (P = .011), and sinogram-affirmed iterative reconstruction at 25% and 50% exposure reduction was noninferior to FBP at 100% exposure (P ≤ .013). Reader confidence was greater with sinogram-affirmed iterative reconstruction than with FBP for 10- and 15-mm lesions (2.94 vs 2.76 and 3.62 vs 3.52, respectively). CONCLUSION: In this low-contrast low-attenuation liver lesion model, a 25% exposure reduction maintained noninferior diagnostic accuracy. However, detection was inferior with each subsequent exposure reduction, regardless of reconstruction method. Sinogram-affirmed iterative reconstruction and FBP performed equally well at modest exposure reduction (25%-50%). Readers had higher confidence levels with sinogram-affirmed iterative reconstruction for the 10- and 15-mm lesions.


Assuntos
Hepatopatias/diagnóstico por imagem , Imagens de Fantasmas , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Radiografia Abdominal/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Software
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA