Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1079(1-2): 287-98, 2005 Jun 24.
Artigo em Inglês | MEDLINE | ID: mdl-16038315

RESUMO

The performance characteristics of multidimensional liquid chromatographic protein separations were evaluated using on-line electrospray mass detection, and a novel workflow for automated LC/MS data processing. Two-dimensional ion exchange/reversed-phase LC separations of Escherichia coli cytosol were conducted using either a continuous linear or discontinuous step gradient in the first dimension. Chromatographic profiles of the top 100 most abundant components were characterized to assess overall separation reproducibility within each mode, and to characterize differences in component distribution between the two modes of operation. Analysis of the resulting data indicates that multidimensional separations of complex protein mixtures can be done reproducibly. Furthermore, under the conditions employed within this study, a linear first dimension gradient was more effective at fractionating the protein mixture, distributing fewer major components to multiple second dimension cycles than an equivalent step gradient. The application of on line mass spectrometry, and automated processing of the resulting data, proved valuable for producing component level analysis of multidimensional protein separations.


Assuntos
Cromatografia por Troca Iônica/métodos , Cromatografia Líquida/métodos , Proteínas/isolamento & purificação , Espectrometria de Massas por Ionização por Electrospray/métodos , Escherichia coli/química , Peptídeos/isolamento & purificação , Reprodutibilidade dos Testes
2.
Anal Chem ; 77(7): 2187-200, 2005 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-15801753

RESUMO

Current methodologies for protein quantitation include 2-dimensional gel electrophoresis techniques, metabolic labeling, and stable isotope labeling methods to name only a few. The current literature illustrates both pros and cons for each of the previously mentioned methodologies. Keeping with the teachings of William of Ockham, "with all things being equal the simplest solution tends to be correct", a simple LC/MS based methodology is presented that allows relative changes in abundance of proteins in highly complex mixtures to be determined. Utilizing a reproducible chromatographic separations system along with the high mass resolution and mass accuracy of an orthogonal time-of-flight mass spectrometer, the quantitative comparison of tens of thousands of ions emanating from identically prepared control and experimental samples can be made. Using this configuration, we can determine the change in relative abundance of a small number of ions between the two conditions solely by accurate mass and retention time. Employing standard operating procedures for both sample preparation and ESI-mass spectrometry, one typically obtains under 5 ppm mass precision and quantitative variations between 10 and 15%. The principal focus of this paper will demonstrate the quantitative aspects of the methodology and continue with a discussion of the associated, complementary qualitative capabilities.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Espectrometria de Massas/métodos , Peptídeos/análise , Proteômica/métodos , Interpretação Estatística de Dados , Humanos , Íons , Peptídeos/química , Soro/química , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA