Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiology ; 308(2): e223016, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37526545

RESUMO

Background Carbon 11 (11C)-methionine is a useful PET radiotracer for the management of patients with glioma, but radiation exposure and lack of molecular imaging facilities limit its use. Purpose To generate synthetic methionine PET images from contrast-enhanced (CE) MRI through an artificial intelligence (AI)-based image-to-image translation model and to compare its performance for grading and prognosis of gliomas with that of real PET. Materials and Methods An AI-based model to generate synthetic methionine PET images from CE MRI was developed and validated from patients who underwent both methionine PET and CE MRI at a university hospital from January 2007 to December 2018 (institutional data set). Pearson correlation coefficients for the maximum and mean tumor to background ratio (TBRmax and TBRmean, respectively) of methionine uptake and the lesion volume between synthetic and real PET were calculated. Two additional open-source glioma databases of preoperative CE MRI without methionine PET were used as the external test set. Using the TBRs, the area under the receiver operating characteristic curve (AUC) for classifying high-grade and low-grade gliomas and overall survival were evaluated. Results The institutional data set included 362 patients (mean age, 49 years ± 19 [SD]; 195 female, 167 male; training, n = 294; validation, n = 34; test, n = 34). In the internal test set, Pearson correlation coefficients were 0.68 (95% CI: 0.47, 0.81), 0.76 (95% CI: 0.59, 0.86), and 0.92 (95% CI: 0.85, 0.95) for TBRmax, TBRmean, and lesion volume, respectively. The external test set included 344 patients with gliomas (mean age, 53 years ± 15; 192 male, 152 female; high grade, n = 269). The AUC for TBRmax was 0.81 (95% CI: 0.75, 0.86) and the overall survival analysis showed a significant difference between the high (2-year survival rate, 27%) and low (2-year survival rate, 71%; P < .001) TBRmax groups. Conclusion The AI-based model-generated synthetic methionine PET images strongly correlated with real PET images and showed good performance for glioma grading and prognostication. Published under a CC BY 4.0 license. Supplemental material is available for this article.


Assuntos
Neoplasias Encefálicas , Glioma , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Metionina , Neoplasias Encefálicas/diagnóstico por imagem , Neoplasias Encefálicas/patologia , Inteligência Artificial , Tomografia por Emissão de Pósitrons/métodos , Gradação de Tumores , Glioma/diagnóstico por imagem , Glioma/patologia , Imageamento por Ressonância Magnética/métodos , Racemetionina
2.
Eur J Radiol ; 154: 110433, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35834858

RESUMO

PURPOSE: To evaluate visually and quantitatively the performance of a deep-learning-based super-resolution (SR) model for microcalcifications in digital mammography. METHOD: Mammograms were consecutively collected from 5080 patients who underwent breast cancer screening from January 2015 to March 2017. Of these, 93 patients (136 breasts, mean age, 50 ± 7 years) had microcalcifications in their breasts on mammograms. We applied an artificial intelligence model known as a fast SR convolutional neural network to the mammograms. SR and original mammograms were visually evaluated by four breast radiologists using a 5-point scale (1: original mammograms are strongly preferred, 5: SR mammograms are strongly preferred) for the detection, diagnostic quality, contrast, sharpness, and noise of microcalcifications. Mammograms were quantitatively evaluated using a perception-based image-quality evaluator (PIQE). RESULTS: All radiologists rated the SR mammograms better than the original ones in terms of detection, diagnostic quality, contrast, and sharpness of microcalcifications. These ratings were significantly different according to the Wilcoxon signed-rank test (p <.001), while the noise score of the three radiologists was significantly lower (p <.001). According to PIQE, SR mammograms were rated better than the original mammograms, showing a significant difference by paired t-test (p <.001). CONCLUSION: An SR model based on deep learning can improve the visibility of microcalcifications in mammography and help detect and diagnose them in mammograms.


Assuntos
Neoplasias da Mama , Calcinose , Aprendizado Profundo , Adulto , Inteligência Artificial , Neoplasias da Mama/diagnóstico por imagem , Calcinose/diagnóstico por imagem , Feminino , Humanos , Mamografia , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
3.
Ann Nucl Med ; 36(5): 468-478, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35182328

RESUMO

OBJECTIVE: It is important to detect parathyroid adenomas by parathyroid scintigraphy with 99m-technetium sestamibi (99mTc-MIBI) before surgery. This study aimed to develop and validate deep learning (DL)-based models to detect parathyroid adenoma in patients with primary hyperparathyroidism, from parathyroid scintigrams with 99mTc-MIBI. METHODS: DL-based models for detecting parathyroid adenoma in early- and late-phase parathyroid scintigrams were, respectively, developed and evaluated. The training dataset used to train the models was collected from 192 patients (165 adenoma cases, mean age: 64 years ± 13, 145 women) and the validation dataset used to tune the models was collected from 45 patients (30 adenoma cases, mean age: 67 years ± 12, 37 women). The images were collected from patients who were pathologically diagnosed with parathyroid adenomas or in whom no lesions could be detected by either parathyroid scintigraphy or ultrasonography at our institution from June 2010 to March 2019. The models were tested on a dataset collected from 44 patients (30 adenoma cases, mean age: 67 years ± 12, 38 women) who took scintigraphy from April 2019 to March 2020. The models' lesion-based sensitivity and mean false positive indications per image (mFPI) were assessed with the test dataset. RESULTS: The sensitivity was 82% [95% confidence interval 72-92%] with mFPI of 0.44 for the scintigrams of the early-phase model and 83% [73-92%] with mFPI of 0.31 for the scintigrams of the delayed-phase model in the test dataset, respectively. CONCLUSIONS: The DL-based models were able to detect parathyroid adenomas with a high sensitivity using parathyroid scintigraphy with 99m-technetium sestamibi.


Assuntos
Adenoma , Aprendizado Profundo , Hiperparatireoidismo Primário , Neoplasias das Paratireoides , Adenoma/complicações , Adenoma/diagnóstico por imagem , Idoso , Feminino , Humanos , Hiperparatireoidismo Primário/diagnóstico por imagem , Hiperparatireoidismo Primário/patologia , Masculino , Pessoa de Meia-Idade , Glândulas Paratireoides/diagnóstico por imagem , Glândulas Paratireoides/patologia , Neoplasias das Paratireoides/diagnóstico por imagem , Neoplasias das Paratireoides/cirurgia , Cintilografia , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade , Tecnécio , Tecnécio Tc 99m Sestamibi
4.
Front Neurol ; 9: 788, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30298047

RESUMO

Background and objective: Phase difference enhanced imaging (PADRE), a new phase-related MRI technique, can enhance both paramagnetic and diamagnetic substances, and select which phases to be enhanced. Utilizing these characteristics, we developed color map of PADRE (Color PADRE), which enables simultaneous visualization of myelin-rich structures and veins. Our aim was to determine whether Color PADRE is sufficient to delineate the characteristics of non-gadolinium-enhancing T2-hyperintense regions related with metastatic tumors (MTs), diffuse astrocytomas (DAs) and glioblastomas (GBs), and whether it can contribute to the differentiation of MTs from GBs. Methods: Color PADRE images of 11 patients with MTs, nine with DAs and 17 with GBs were created by combining tissue-enhanced, vessel-enhanced and magnitude images of PADRE, and then retrospectively reviewed. First, predominant visibility of superficial white matter and deep medullary veins within non-gadolinium-enhancing T2-hyperintense regions were compared among the three groups. Then, the discriminatory power to differentiate MTs from GBs was assessed using receiver operating characteristic analysis. Results: The degree of visibility of superficial white matter was significantly better in MTs than in GBs (p = 0.017), better in GBs than in DAs (p = 0.014), and better in MTs than in DAs (p = 0.0021). On the contrary, the difference in the visibility of deep medullary veins was not significant (p = 0.065). The area under the receiver operating characteristic curve to discriminate MTs from GBs was 0.76 with a sensitivity of 80% and specificity of 64%. Conclusion: Visibility of superficial white matter on Color PADRE reflects inferred differences in the proportion of vasogenic edema and tumoral infiltration within non-gadolinium-enhancing T2-hyperintense regions of MTs, DAs and GBs. Evaluation of peritumoral areas on Color PADRE can help to distinguish MTs from GBs.

5.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(11): 1091-1097, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-27867168

RESUMO

We report on the methods and experiences of the dual-phase cone beam computed tomography during hepatic arteriography (CBCTHA) to apply the 3D-DSA. A total of 32 ml contrast medium (150 mgI/ml) was injected at the rate of 2.0 ml/s for 16 s. The early phase scan was initiated 10 s after the start of contrast media injection. The delayed phase scan was started 40 s after that (24 s after the end of CM injection). When using the dual phase CBCTHA, it was able to obtain the classical hepatocellular carcinoma (HCC) images same as computed tomography during hepatic arteriography (CTHA). In the early phase, the tumor can be highly enhanced against the liver parenchyma. In delayed phase, corona enhancement was clearly appeared at the liver parenchyma. Of 58 cases of acquisitions, we experienced six cases with miss breath holding and 14 cases with over the field of view (FOV) due to hepatomegaly. We evaluated the tumor contrast in 18 cases because the other 40 cases were not applied to our criteria. The pixel values of ROIs on the tumor, coronal enhancement, and liver parenchyma were measured, respectively. Then, we calculated tumor-parenchyma contrast (T-P contrast), corona-tumor contrast (C-T contrast), and corona-parenchyma contrast (C-P contrast). The T-P contrast was 358±112, the C-T contrast was 132±51, and the C-P contrast was 168±66. The contrast was clearly visualized among them. The dual-phase CBCTHA that applies the 3D-DSA is a simple and useful technique for hepatocellular carcinoma treatment.


Assuntos
Angiografia , Tomografia Computadorizada de Feixe Cônico , Artéria Hepática/diagnóstico por imagem , Fígado/irrigação sanguínea , Idoso , Tomografia Computadorizada de Feixe Cônico/instrumentação , Feminino , Humanos , Imageamento Tridimensional , Masculino
6.
Nihon Hoshasen Gijutsu Gakkai Zasshi ; 72(11): 1144-1151, 2016.
Artigo em Japonês | MEDLINE | ID: mdl-27867175

RESUMO

The purpose of this study was to understand the scatter radiation distribution during C-arm CT examination in the interventional radiography (IVR) room to show the escaped area and the radiation protective method. The C-arm rotates 200° in 5 s. The tube voltage was 90 kV, and the entrance dose to the detector was 0.36 µGy/frame during C-arm CT examination. The scattered doses were measured each 50 cm from the isocenter like a grid pattern. The heights of the measurement were 50, 100, and 150 cm from the floor. The maximum scattered doses were 38.23±0.60 µGy at 50 cm, 43.86±0.20 µGy at 100 cm, and 25.78±0.37 µGy at 150 cm. The scatter radiation distribution at 100 cm was the highest scattered dose. The operator should protect their reproductive gland, thyroid, and lens. The scattered dose was low behind the C-arm body and the bed, so they will be able to become the escaped area for staff.


Assuntos
Imagens de Fantasmas , Tomografia Computadorizada por Raios X/instrumentação
7.
Radiol Phys Technol ; 9(2): 170-7, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26873140

RESUMO

Our aim in this study was to verify the usefulness of the standardized uptake value (SUV) normalized by individual CT-based lean body mass (LBMCT) in application of PET response criteria in solid tumors (PERCIST).We retrospectively investigated 14 patients (4 male and 10 female) with malignant lymphoma who were undergoing chemotherapy. (18)F-FDG PET/CT examinations were performed before and after chemotherapy. The LBMCT was calculated by estimation of fat weight from CT data (from skull base to pelvis). The mean ± standard deviation (SD) and the Bland-Altman plot were used for comparison among body weight, LBMCT, and LBM derived from a predictive equation (LBMPE). Indices for FDG uptake in the liver were: SUV, SUV based on LBMPE (SULPE), and SUV based on LBMCT (SULCT). Overall differences between the uptake values were analyzed by one-way ANOVA. If the ANOVA showed significance, differences between uptake values were investigated further by use of the Tukey-Kramer test. The mean values of body weight, LBMPE, and LBMCT were: 55.4 ± 14.9 (39.0-112.0), 43.0 ± 10.5 (31.3-75.2), and 35.3 ± 9.8 (23.4-75.8) kg, respectively. There was a wide dispersion between LBMPE and LBMCT (differences, 7.6 ± 3.6 kg; 95 % CI, 6.42-8.85). LBMPE was higher than LBMCT in all the cases except in Case 11. The mean uptake values significantly differed among SUV, SULPE, and SULCT (F = 68.3, p < 0.05). Whereas SULPE deviated from PERCIST criteria in seven patients, SULCT satisfied the criteria except in one case. These results suggest that liver SULCT is useful for application of PERCIST.


Assuntos
Índice de Massa Corporal , Processamento de Imagem Assistida por Computador/normas , Linfoma/diagnóstico por imagem , Linfoma/metabolismo , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Adulto , Transporte Biológico , Feminino , Fluordesoxiglucose F18/metabolismo , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Masculino , Pessoa de Meia-Idade , Padrões de Referência , Estudos Retrospectivos , Razão Sinal-Ruído
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA