Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38400814

RESUMO

OBJECTIVES: Since 2000, we anastomosed the saphenous vein graft to the right coronary artery system using the stump of the right internal thoracic artery as inflow. The long-term results of patients where the right coronary artery was grafted with the right internal thoracic artery or the ascending aorta as saphenous vein inflow has not been reported. METHODS: From 2000 to 2018, 699 consecutive patients had right internal thoracic artery elongated with saphenous vein (I-graft group, n = 358, 51.2%) or saphenous vein from the aorta (Ao-graft group, n = 341, 48.8%) on right coronary artery system. Inclusion criteria were age ≤75 years, bilateral internal thoracic arteries as a Y graft on the left system (three-vessel disease, n = 603, 86.3%) or as a left internal thoracic artery on left anterior descending and right internal thoracic artery elongated with saphenous vein on the right coronary artery system (two-vessel disease, n = 96, 13.7%), only 1 saphenous vein per patient. Propensity-matching identified 272 patients per group. One-hundred and twenty-two patients underwent coronary computed tomographic angiography to asses grafts patency after a median follow-up of 88 (65-93) months. RESULTS: In the paired samples, there was no difference in the early outcome. Ten-year survival and freedom from death, non-fatal acute myocardial infarction and repeat revascularization were higher in I-graft group: 90.6 [standard error (SE): 2.0] vs 78.2 (SE: 5.3), P = 0.0266, and 85.2 (SE: 2.4) vs 69.9 (SE: 5.3), P = 0.0179. Saphenous vein graft, at a long-time follow-up, showed a higher patency rate (81.6% (SE: 7.0) vs 50.7% (SE: 7.9), P < 0.0001) and a smaller internal lumen diameter (2.7, standard deviation: 0.4 vs 3.4, standard deviation: 0.6 mm, P < 0.0001) when right internal thoracic artery was the inflow. CONCLUSIONS: Grafting the right coronary artery with saphenous vein may entail higher patency rate and better outcome when the inflow is the right internal thoracic artery than when is the ascending aorta. Prospective randomized data are needed to test this hypothesis.


Assuntos
Ponte de Artéria Coronária , Artéria Torácica Interna , Humanos , Idoso , Ponte de Artéria Coronária/métodos , Angiografia Coronária , Veia Safena/transplante , Estudos Prospectivos , Grau de Desobstrução Vascular , Resultado do Tratamento , Aorta/diagnóstico por imagem , Aorta/cirurgia , Artéria Torácica Interna/transplante
2.
Curr Probl Cardiol ; 49(1 Pt C): 102200, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37956917

RESUMO

In an adult patient, coronary artery fistula involving the circumflex artery (CX) connected to the coronary sinus caused aneurysm of the left main and CX associated with ectasia of the intermediate branch. The patient had posterolateral infarction with severe ischemic mitral regurgitation and moderate tricuspid regurgitation. A rare venous return anomaly was also present. The inferior vena cava, which was interrupted at the level of the liver, continued with the hemiazygos to drain into a persistent left superior vena cava, which in turn drained into the coronary sinus. Surgery included CX closure and mitral and tricuspid repair. The strategy had to be adapted to the anatomy. The fistula was dissected and snared for cardioplegia delivery, and venous return was achieved by cannulation of the superior vena cava and femoral vein. The procedure was uneventful, and 4 years later the patient is asymptomatic.


Assuntos
Seio Coronário , Fístula , Cardiopatias Congênitas , Humanos , Adulto , Seio Coronário/cirurgia , Veia Cava Superior/anormalidades , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/cirurgia , Veia Cava Inferior/cirurgia , Veia Cava Inferior/anormalidades
3.
Open J Cardiovasc Surg ; 11: 1179065219871948, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31488952

RESUMO

Coronary artery bypass surgery still has its unique role in the treatment of coronary artery disease. It faces, however, the continuous challenge of becoming even less invasive and more effective as cases become more complex. We here present the results of 1359 cases treated with the π-circuit technique which consists of an off-pump total myocardial revascularization using composite arterial grafts. The results demonstrate that it is a safe technique providing low mortality, stroke, renal failure, wound infection, and other complication rates. We suggest the application of this technique, as well as of other similar techniques regarding similar principles, especially in high-risk patients.

4.
Eur J Cardiothorac Surg ; 54(5): 884-888, 2018 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29897429

RESUMO

OBJECTIVES: Our goal was to compare the observed and the expected rates of postoperative cerebrovascular accidents (CVA) in a large cohort of consecutive patients undergoing off-pump coronary artery bypass grafting (CABG) using the ∏-circuit as a no-touch technique. METHODS: From January 2001 to May 2016, 3081 patients were consecutively submitted to an off-pump CABG operation using the ∏-circuit. A CVA was defined as a neurological deficit, lasting less (transient ischaemic attack) or more (stroke) than 24 h, diagnosed by a neurologist and confirmed by a computed tomography or magnetic resonance imaging scan of the brain. The primary end point was to compare the observed and the expected rates of CVAs; the latter was obtained using the Society of Thoracic Surgeons' calculator. The secondary end point was to compare the observed and the expected mortality rates using the Society of Thoracic Surgeons' calculator and the prevalence of postoperative complications. Moreover, we identified some subgroups at higher risk. RESULTS: The postoperative rate of CVAs was 0.5% (14 cases): 2 (0.1%) were transient ischaemic attacks and 12 (0.4%) were strokes. The mean expected CVA rate (1.6%) was significantly higher than the observed rate (P < 0.001). None of patients who experienced postoperative CVAs died. The observed mortality was 1.3% (40 patients) vs the expected mortality (2.6%), which was significantly higher (P < 0.001). Multivariable analysis identified age >70 years old, diabetes, extracardiac vasculopathy and chronic renal failure as risk factors for postoperative CVAs. However, in all the subgroups of risk, except for those with chronic renal failure, the use of the ∏-circuit was associated with a low rate of CVAs. CONCLUSIONS: The ∏-circuit should be included as a possible choice among no-touch techniques. The observed rate of CVAs of 75% is lower than the expected rate.


Assuntos
Ponte de Artéria Coronária sem Circulação Extracorpórea/métodos , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Idoso , Angiografia Coronária , Ponte de Artéria Coronária sem Circulação Extracorpórea/efeitos adversos , Feminino , Humanos , Ataque Isquêmico Transitório/diagnóstico por imagem , Ataque Isquêmico Transitório/etiologia , Ataque Isquêmico Transitório/prevenção & controle , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico por imagem , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA