Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Coron Artery Dis ; 32(5): 391-396, 2021 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-33060529

RESUMO

OBJECTIVES: Recent improvements in coronary stent design have focussed on thinner struts, different alloys and architecture, more biocompatible polymers, and shorter drug absorption times. This study evaluates safety and efficacy of a newer generation thin-strut cobalt chromium sirolimus-eluting coronary stent (SES, Ultimaster) in comparison with a second-generation thicker strut stainless steel biolimus-eluting stent (BES, Nobori) in percutaneous coronary intervention (PCI) practice. METHODS: A propensity score analysis was performed to adjust for differences in baseline characteristics of 8137 SES patients and 2738 BES patients of two PCI registries (e-Ultimaster and NOBORI 2). An independent clinical event committee adjudicated all endpoint-related adverse events. RESULTS: The use of SES, as compared with BES was associated with a significantly lower rate of myocardial infarction (MI) (1.2% vs 2.2%; P = 0.0006) and target vessel-related MI (1.1% vs 1.8%; P = 0.002) at 1 year. One-year composite endpoints of all predefined endpoints were lower in patients undergoing SES implantation (target lesion failure: 3.2% vs 4.1%; P = 0.03, target vessel failure: 3.7% vs 5.0%; P = 0.003, patient-oriented composite endpoint 5.7% vs 6.8%; P = 0.03). No significant differences between SES and BES were observed in all-cause death (2.0% vs 1.6%; P = 0.19), cardiac death (1.2% vs 1.2%; P = 0.76) or stent thrombosis (0.6% vs 0.8%; P = 0.43). CONCLUSIONS: These findings suggest an improved clinical safety and efficacy of a newer generation thin-strut SES as compared with a second-generation thicker strut BES.


Assuntos
Ligas de Cromo/farmacologia , Doença da Artéria Coronariana/cirurgia , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso , Materiais Biocompatíveis/farmacologia , Reestenose Coronária/diagnóstico , Reestenose Coronária/etiologia , Reestenose Coronária/mortalidade , Stents Farmacológicos/efeitos adversos , Stents Farmacológicos/classificação , Análise de Falha de Equipamento , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Desenho de Prótese , Sistema de Registros/estatística & dados numéricos , Análise de Sobrevida
2.
Clin Res Cardiol ; 109(7): 845-856, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31792571

RESUMO

BACKGROUND: Chronic kidney disease (CKD) is highly prevalent in patients with coronary artery disease (CAD). OBJECTIVE: The outcome following revascularization using contemporary technologies (new-generation abluminal sirolimus-eluting stents with thin struts) in patients with CKD (i.e., glomerular filtration rate of < 60 mL/min/1.73m2) and in patients with hemodialysis (HD) is unknown. METHODS: e-Ultimaster is a prospective, single-arm, multi-center registry with clinical follow-up at 3 months and 1 year. RESULTS: A total of 19,475 patients were enrolled, including 1466 patients with CKD, with 167 undergoing HD. Patients with CKD had a higher prevalence of overall comorbidities, multiple/small vessel disease (≤ 2.75 mm), bifurcation lesions, and more often left main artery treatments (all p < 0.0001) when compared with patients with normal renal function (reference). CKD patients had a higher risk of target lesion failure (unadjusted OR, 2.51 [95% CI 2.04-3.08]), target vessel failure (OR, 2.44 [95% CI 2.01-2.96]), patient-oriented composite end point (OR, 2.19 [95% CI 1.87-2.56]), and major adverse cardiovascular events (OR, 2.34 [95% CI 1.93-2.83, p for all < 0.0001]) as reference. The rates of target lesion revascularization (OR, 1.17 [95% CI 0.79-1.73], p = 0.44) were not different. Bleeding complications were more frequently observed in CKD than in the reference (all p < 0.0001). CONCLUSION: In this worldwide registry, CKD patients presented with more comorbidities and more complex lesions when compared with the reference population. They experienced higher rate of adverse events at 1-year follow-up. One-year summary outcomes of contemporary PCI in renal insufficiency. CKD chronic kidney disease, POCE patient oriented composite endpoint, MACE major adverse cardiovascular events, TLF target lesion failure, TLR target lesion revascularization, ST stent thrombosis.


Assuntos
Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Intervenção Coronária Percutânea , Insuficiência Renal Crônica/complicações , Idoso , Estudos de Coortes , Stents Farmacológicos , Feminino , Taxa de Filtração Glomerular , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Diálise Renal , Insuficiência Renal Crônica/terapia , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA