Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 80
Filtrar
1.
Mol Ther Oncol ; 32(1): 200775, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38596311

RESUMO

Chimeric antigen receptor (CAR) T cell therapies targeting B cell-restricted antigens CD19, CD20, or CD22 can produce potent clinical responses for some B cell malignancies, but relapse remains common. Camelid single-domain antibodies (sdAbs or nanobodies) are smaller, simpler, and easier to recombine than single-chain variable fragments (scFvs) used in most CARs, but fewer sdAb-CARs have been reported. Thus, we sought to identify a therapeutically active sdAb-CAR targeting human CD22. Immunization of an adult Llama glama with CD22 protein, sdAb-cDNA library construction, and phage panning yielded >20 sdAbs with diverse epitope and binding properties. Expressing CD22-sdAb-CAR in Jurkat cells drove varying CD22-specific reactivity not correlated with antibody affinity. Changing CD28- to CD8-transmembrane design increased CAR persistence and expression in vitro. CD22-sdAb-CAR candidates showed similar CD22-dependent CAR-T expansion in vitro, although only membrane-proximal epitope targeting CD22-sdAb-CARs activated direct cytolytic killing and extended survival in a lymphoma xenograft model. Based on enhanced survival in blinded xenograft studies, a lead CD22sdCAR-T was selected, achieving comparable complete responses to a benchmark short linker m971-scFv CAR-T in high-dose experiments. Finally, immunohistochemistry and flow cytometry confirm tissue and cellular-level specificity of the lead CD22-sdAb. This presents a complete report on preclinical development of a novel CD22sdCAR therapeutic.

2.
Med Phys ; 51(4): 2998-3009, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38060696

RESUMO

BACKGROUND: The static magnetic field present in magnetic resonance (MR)-guided radiotherapy systems can influence dose deposition and charged particle collection in air-filled ionization chambers. Thus, accurately quantifying the effect of the magnetic field on ionization chamber response is critical for output calibration. Formalisms for reference dosimetry in a magnetic field have been proposed, whereby a magnetic field quality conversion factor kB,Q is defined to account for the combined effects of the magnetic field on the radiation detector. Determination of kB,Q in the literature has focused on Monte Carlo simulation studies, with experimental validation limited to only a few ionization chamber models. PURPOSE: The purpose of this study is to experimentally measure kB,Q for 11 ionization chamber models in two commercially available MR-guided radiotherapy systems: Elekta Unity and ViewRay MRIdian. METHODS: Eleven ionization chamber models were characterized in this study: Exradin A12, A12S, A28, and A26, PTW T31010, T31021, and T31022, and IBA FC23-C, CC25, CC13, and CC08. The experimental method to measure kB,Q utilized cross-calibration against a reference Exradin A1SL chamber. Absorbed dose to water was measured for the reference A1SL chamber positioned parallel to the magnetic field with its centroid placed at the machine isocenter at a depth of 10 cm in water for a 10 × 10 cm2 field size at that depth. Output was subsequently measured with the test chamber at the same point of measurement. kB,Q for the test chamber was computed as the ratio of reference dose to test chamber output, with this procedure repeated for each chamber in each MR-guided radiotherapy system. For the high-field 1.5 T Elekta Unity system, the dependence of kB,Q on the chamber orientation relative to the magnetic field was quantified by rotating the chamber about the machine isocenter. RESULTS: Measured kB,Q values for our test dataset of ionization chamber models ranged from 0.991 to 1.002, and 0.995 to 1.004 for the Elekta Unity and ViewRay MRIdian, respectively, with kB,Q tending to increase as the chamber sensitive volume increased. Measured kB,Q values largely agreed within uncertainty to published Monte Carlo simulation data and available experimental data. kB,Q deviation from unity was minimized for ionization chamber orientation parallel or antiparallel to the magnetic field, with increased deviations observed at perpendicular orientations. Overall (k = 1) uncertainty in the experimental determination of the magnetic field quality conversion factor, kB,Q was 0.71% and 0.72% for the Elekta Unity and ViewRay MRIdian systems, respectively. CONCLUSIONS: For a high-field MR-linac, the characterization of ionization chamber performance as angular orientation varied relative to the magnetic field confirmed that the ideal orientation for output calibration is parallel. For most of these chamber models, this study represents the first experimental characterization of chamber performance in clinical MR-linac beams. This is a critical step toward accurate output calibration for MR-guided radiotherapy systems and the measured kB,Q values will be an important reference data source for forthcoming MR-linac reference dosimetry protocols.


Assuntos
Radiometria , Radioterapia Guiada por Imagem , Eficiência Biológica Relativa , Campos Magnéticos , Método de Monte Carlo , Água
4.
Med Phys ; 2023 Dec 13.
Artigo em Inglês | MEDLINE | ID: mdl-38088935

RESUMO

BACKGROUND: The radiotherapy process relies on several metrics in determining a notion of "distance" from one three-dimensional region-of-interest (ROI) to another. The majority are symmetric (or commutative) and do not contain information pertaining to directionality. Growth versus regression, for example, is not inherently distinguished by these metrics. PURPOSE: The purpose of this work was to formalize a unidirectional distance metric, motivated by radiotherapy margin concepts, which we term the migration distance. Informally, the migration distance from ROI X to Y is the minimum isotropic expansion of X such that Y is completely encompassed by the expansion. If Y is contained within X, the migration distance is negative with magnitude equal to the maximum isotropic contraction of X such that Y remains contained within contraction. The metric is demonstrated by quantifying glioblastoma interfraction target changes. METHODS: An explicit mathematical formulation of the migration distance is presented and contrasted with the related Hausdorff distance. The results are demonstrated for the gross tumor volume (GTV) dynamics of a glioblastoma cohort consisting of 111 patients that underwent standard chemoradiotherapy with offline MR imaging at planning, fraction 10, fraction 20, and 1-month post radiotherapy. RESULTS: The mean ± SD of the GTV migration distance relative to planning was 5.9 ± 3.9 mm at fraction 10, 6.2 ± 4.4 mm at fraction 20, and 7.9 ± 7.1 mm at 1-month post radiotherapy. The maximum GTV migration distance across all patients at the same timepoints was 20.4, 20.7, and 45.5 mm, respectively. CONCLUSIONS: We have proposed and demonstrated a unidirectional distance metric. The migration distance may have applications in the quantification of anatomical changes, planning target volume designs, and dosimetric radiotherapy plan assessment.

5.
J Appl Clin Med Phys ; 24(11): e14087, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37354202

RESUMO

BACKGROUND: Magnetic resonance (MR)-guided radiation therapy provides capabilities to utilize high-resolution and real-time MR imaging before and during treatment, which is critical for adaptive radiotherapy. This emerging modality has been promptly adopted in the clinic settings in advance of adaptations to reference dosimetry formalism that are needed to account for the presence of strong magnetic fields. In particular, the influence of magnetic field on the uncertainty of parameters in the reference dosimetry equation needs to be determined in order to fully characterize the uncertainty budget for reference dosimetry in MR-guided radiation therapy systems. PURPOSE: To identify and quantify key sources of uncertainty in the reference dosimetry of external high energy radiotherapy beams in the presence of a strong magnetic field. METHODS: In the absence of a formalized Task Group report for reference dosimetry in MR-integrated linacs, the currently suggested formalism follows the TG-51 protocol with the addition of a quality conversion factor kBQ accounting for the effects of the magnetic field on ionization chamber response. In this work, we quantify various sources of uncertainty that impact each of the parameters in the formalism, and evaluate their overall contribution to the final dose. Measurements are done in a 1.5 T MR-Linac (Unity, Elekta AB, Stockholm, Sweden) which integrates a 1.5 T Philips MR scanner and a 7 MVFFF linac. The responses of several reference-class small volume ionization chambers (Exradin:A1SL, IBA:CC13, PTW:Semiflex-3D) and Farmer type ionization chambers (Exradin:A19, IBA:FC65-G) were evaluated throughout this process. Long-term reproducibility and stability of beam quality, TPR 10 20 ${\mathrm{TPR}}_{10}^{20}$ , was also measured with an in-house built phantom. RESULTS: Relative to the conventional external high energy linacs, the uncertainty on overall reference dose in MR-linac is more significantly affected by the chamber setup: A translational displacement along y-axis of ± 3 mm results in dose variation of < |0.20| ± 0.02% (k = 1), while rotation of ± 5° in horizontal and vertical parallel planes relative to relative to the direction of magnetic field, did not exceed variation of < |0.44| ± 0.02% for all 5 ionization chambers. We measured a larger dose variation for xy-plane (horizontal) rotations (< |0.44| ± 0.02% (k = 1)) than for yz-plane (vertical) rotations (< ||0.28| ± 0.02% (k = 1)), which we associate with the gradient of kB,Q as a function of chamber orientation with respect to direction of the B0 -field. Uncertainty in Pion (for two depths), Ppol (with various sub-studies including effects of cable length, cable looping in the MRgRT bore, connector type in magnetic environment), and Prp were determined. Combined conversion factor kQ × kB,Q was provided for two reference depths at four cardinal angle orientations. Over a two-year period, beam quality was quite stable with TPR 10 20 ${\mathrm{TPR}}_{10}^{20}$ being 0.669 ± 0.01%. The actual magnitude of TPR 10 20 ${\mathrm{TPR}}_{10}^{20}$ was measured using identical equipment and compared between two different Elekta Unity MR-Linacs with results agreeing to within 0.21%. CONCLUSION: In this work, the uncertainty of a number of parameters influencing reference dosimetry was quantified. The results of this work can be used to identify best practice guidelines for reference dosimetry in the presence of magnetic fields, and to evaluate an uncertainty budget for future reference dosimetry protocols for MR-linac.


Assuntos
Aceleradores de Partículas , Radiometria , Humanos , Incerteza , Reprodutibilidade dos Testes , Radiometria/métodos , Imageamento por Ressonância Magnética , Espectroscopia de Ressonância Magnética
6.
Clin Transl Radiat Oncol ; 39: 100582, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36699195

RESUMO

Purpose: Magnetic resonance image-guided radiotherapy for intracranial indications is a promising advance; however, uncertainties remain for both target localization after translation-only MR setup and intrafraction motion. This investigation quantified these uncertainties and developed a population-based planning target volume (PTV) model to explore target and organ-at-risk (OAR) volumetric coverage tradeoffs. Methods: Sixty-six patients, 49 with a primary brain tumor and 17 with a post-surgical resection cavity, treated on a 1.5T-based MR-linac across 1329 fractions were included. At each fraction, patients were setup by translation-only fusion of the online T1 MRI to the planning image. Each fusion was independently repeated offline accounting for rotations. The six degree-of-freedom difference between fusions was applied to transform the planning CTV at each fraction (CTVfx). A PTV model parameterized by volumetric CTVfx coverage, proportion of fractions, and proportion of patients was developed. Intrafraction motion was quantified in a 412 fraction subset as the fusion difference between post- and pre-irradiation T1 MRIs. Results: For the left-right/anterior-posterior/superior-inferior axes, mean ± SD of the rotational fusion differences were 0.1 ± 0.8/0.1 ± 0.8/-0.2 ± 0.9°. Covering 98 % of the CTVfx in 95 % of fractions in 95 % of patients required a 3 mm PTV margin. Margin reduction decreased PTV-OAR overlap; for example, the proportion of optic chiasm overlapped by the PTV was reduced up to 23.5 % by margin reduction from 4 mm to 3 mm. Conclusions: An evidence-based PTV model was developed for brain cancer patients treated on the MR-linac. Informed by this model, we have clinically adopted a 3 mm PTV margin for conventionally fractionated intracranial patients.

7.
J Thorac Cardiovasc Surg ; 166(6): 1529-1541.e4, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-36049964

RESUMO

OBJECTIVE: For some individuals, chronic allograft failure is best treated with retransplantation. We sought to determine if time to retransplantation impacts short- and long-term outcomes for heart or lung retransplant recipients with a time to retransplantation more than 1 year. METHODS: The United Network for Organ Sharing/Organ Procurement and Transplantation Network STAR file was queried for all adult, first-time heart (June 1, 2006, to September 30, 2020) and lung (May 1, 2005, to September 30, 2020) retransplantations with a time to retransplantation of at least 1 year. Patients were grouped according to the tertile of time to retransplantation (tertile 1: 1-7.7 years, tertile 2: 7.7-14.7 years, tertile 3: 14.7+ years; lung: tertile 1: 1-2.8 years, tertile 2: 2.8-5.6 years, tertile 3: 5.6+ years). The primary outcome was survival after retransplantation. Comparative statistics identified differences in groups, and Kaplan-Meier methods and a Cox proportional hazard model were used for survival analysis. RESULTS: After selection, 908 heart and 871 lung retransplants were identified. Among heart retransplant recipients, tertile 1 was associated with male sex, smoking history, higher listing status, and increased mechanical support pretransplant. Tertile 3 had the highest rate of concomitant kidney transplant; however, the incidence of morbidity and in-hospital mortality was similar among the groups. Unadjusted and adjusted analyses revealed no survival difference among all groups. Regarding lung retransplant recipients, tertile 1 was associated with increased lung allocation score, pretransplant hospitalization, and mechanical support. Unadjusted and adjusted survival analyses revealed decreased survival in tertile 1. CONCLUSIONS: Time to retransplant does not appear to affect heart recipients with a time to retransplantation of more than 1 year; however, shorter time to retransplantation for prior lung recipients is associated with decreased survival. Potential lung retransplant candidates with a time to retransplantation of less than 2.8 years should be carefully evaluated before retransplantation.


Assuntos
Transplante de Coração , Transplante de Pulmão , Adulto , Humanos , Masculino , Reoperação , Pulmão , Transplante de Pulmão/efeitos adversos , Transplante Homólogo , Estudos Retrospectivos , Sobrevivência de Enxerto
8.
Ann Thorac Surg ; 115(1): 221-230, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-35940315

RESUMO

BACKGROUND: Donors with hepatitis C virus (HCV) have expanded the donor pool for heart and lung transplantation, but concerns have arisen about rejection. We examined the incidence of rejection after heart and lung transplantation in recipients of HCV-positive donors as well as HCV-positive recipients. METHODS: Adults undergoing heart and lung transplantation from March 31, 2015 to December 31, 2019 were identified in the United Network for Organ Sharing/Organ Transplantation and Procurement Network Standard Transplant Analysis and Research file. Patients were stratified as donor-recipient HCV negative, donor positive, and recipient positive. Comparative statistics and a multilevel logistic regression model were used. RESULTS: Meeting the criteria were 10 624 heart transplant recipients. Donor-positive recipients were significantly associated with older age, blood group O, and shorter waitlist time. No significant differences existed with regards to treatment for rejection in the first year (negative, 19.5%; donor positive, 22.3%; recipient positive, 19.5%; P = .45) or other outcomes. On regression analysis HCV status was not associated with treated rejection; however center variability was significantly associated with treated rejection (median odds ratio, 2.18). Similarly, 9917 lung transplant recipients were identified. Donor-positive recipients were more commonly White and had obstructive disease and lower lung allocation scores. Both unadjusted (negative, 22.1%; donor positive, 23.0%; recipient positive, 18.6%; P = .43) and adjusted analyses failed to demonstrate a significant association between HCV status and treatment for rejection, whereas center variability remained significantly associated with treatment for rejection (median odds ratio, 2.41). CONCLUSIONS: Use of HCV donors has expanded the donor pool for heart and lung transplantation. HCV donor status was not associated with treatment for rejection in the first year, but center variability played a role in the incidence and treatment of rejection.


Assuntos
Hepatite C , Transplante de Pulmão , Adulto , Humanos , Hepatite C/epidemiologia , Doadores de Tecidos , Hepacivirus , Pulmão , Estudos Retrospectivos , Rejeição de Enxerto/epidemiologia
9.
Arch Pathol Lab Med ; 147(6): 722-734, 2023 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-36136297

RESUMO

CONTEXT.­: Penile squamous cell carcinomas (PSCCs) are divided into tumors that are human papillomavirus (HPV) associated and those that are non-HPV associated. HPV and non-HPV PSCCs each display unique pathogenic mechanisms, histologic subtypes, and clinical behaviors. Treatment of localized PSCC tumors is linked to significant physical and psychological morbidity, and management of advanced disease is often treatment refractory. The identification of novel actionable mutations is of critical importance so that translational scientists and clinicians alike can pursue additional therapeutic options. OBJECTIVE.­: To provide an update on the molecular pathogenesis associated with PSCC. A special emphasis is placed on next-generation sequencing data and its role in identifying potential therapeutic targets. DATA SOURCES.­: A literature review using the PubMed search engine to access peer-reviewed literature published on PSCC. CONCLUSIONS.­: Our understanding of the genetic and molecular mechanisms that underlie PSCC pathogenesis continues to evolve. PSCC tumorigenesis is mediated by multiple pathways, and mutations of oncogenic significance have been identified that may represent targets for personalized therapy. Preliminary results of treatment with immune checkpoint inhibition and tyrosine kinase inhibitors have produced variable clinical results. Further insight into the pathogenesis of PSCC will help guide clinical trials and develop additional precision medicine approaches.


Assuntos
Carcinoma de Células Escamosas , Infecções por Papillomavirus , Neoplasias Penianas , Masculino , Humanos , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/terapia , Carcinoma de Células Escamosas/metabolismo , Neoplasias Penianas/genética , Neoplasias Penianas/terapia , Neoplasias Penianas/patologia
10.
Front Oncol ; 12: 1060098, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36518316

RESUMO

Purpose: This study reports the workflow and initial clinical experience of high grade glioma (HGG) radiotherapy on the 1.5 T MR-Linac (MRL), with a focus on the temporal variations of the tumor and feasibility of multi-parametric image (mpMRI) acquisition during routine treatment workflow. Materials and methods: Ten HGG patients treated with radiation within the first year of the MRL's clinical operation, between October 2019 and August 2020, were identified from a prospective database. Workflow timings were recorded and online adaptive plans were generated using the Adapt-To-Position (ATP) workflow. Temporal variation within the FLAIR hyperintense region (FHR) was assessed by the relative FHR volumes (n = 281 contours) and migration distances (maximum linear displacement of the volume). Research mpMRIs were acquired on the MRL during radiation and changes in selected functional parameters were investigated within the FHR. Results: All patients completed radiotherapy to a median dose of 60 Gy (range, 54-60 Gy) in 30 fractions (range, 30-33), receiving a total of 287 fractions on the MRL. The mean in-room time per fraction with or without post-beam research imaging was 42.9 minutes (range, 25.0-69.0 minutes) and 37.3 minutes (range, 24.0-51.0 minutes), respectively. Three patients (30%) required re-planning between fractions 9 to 12 due to progression of tumor and/or edema identified on daily MRL imaging. At the 10, 20, and 30-day post-first fraction time points 3, 3, and 4 patients, respectively, had a FHR volume that changed by at least 20% relative to the first fraction. Research mpMRIs were successfully acquired on the MRL. The median apparent diffusion coefficient (ADC) within the FHR and the volumes of FLAIR were significantly correlated when data from all patients and time points were pooled (R=0.68, p<.001). Conclusion: We report the first clinical series of HGG patients treated with radiotherapy on the MRL. The ATP workflow and treatment times were clinically acceptable, and daily online MRL imaging triggered adaptive re-planning for selected patients. Acquisition of mpMRIs was feasible on the MRL during routine treatment workflow. Prospective clinical outcomes data is anticipated from the ongoing UNITED phase 2 trial to further refine the role of MR-guided adaptive radiotherapy.

11.
Technol Cancer Res Treat ; 21: 15330338221124695, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36071647

RESUMO

Introduction: Magnetic resonance imaging-linear accelerator radiotherapy is an innovative technology that requires special consideration for secondary electron interactions within the magnetic field, which can alter dose deposition at air-tissue interfaces. As part of ongoing quality assurance and quality improvement of new radiotherapy technologies, the purpose of this study was to evaluate skin dose modelled from the treatment planning systems of a magnetic resonance imaging-linear accelerator and a conventional linear accelerator, and then correlate with in vivo measurements of delivered skin dose from each linear accelerator. Methods: In this prospective cohort study, 37 consecutive glioma patients had treatment planning completed and approved prior to radiotherapy initiation using commercial treatment planning systems: a Monte Carlo-based algorithm for magnetic resonance imaging-linear accelerator or a convolution-based algorithm for conventional linear accelerator. In vivo skin dose was measured using an optically stimulated luminescent dosimeter. Results: Monte Carlo-based magnetic resonance imaging-linear accelerator plans and convolution-based conventional linear accelerator plans had similar dosimetric parameters for target volumes and organs-at-risk. However, magnetic resonance imaging-linear accelerator plans had 1.52 Gy higher mean dose to air cavities (P < .0001) and 1.10 Gy higher mean dose to skin (P < .0001). In vivo skin dose was 14.5% greater for magnetic resonance imaging-linear accelerator treatments (P = .0027), and was more accurately predicted by Monte Carlo-based calculation (ρ = 0.95, P < .0001) versus convolution-based (ρ = 0.80, P = .0096). Conclusion: This is the first prospective dosimetric comparison of glioma patients clinically treated on both magnetic resonance imaging-linear accelerator and conventional linear accelerator. Our findings suggest that skin doses were significantly greater with magnetic resonance imaging-linear accelerator plans but correlated better with in vivo measurements of actual skin dose from delivered treatments. Future magnetic resonance imaging-linear accelerator planning processes are being designed to account for skin dosimetry and treatment delivery.


Assuntos
Glioma , Planejamento da Radioterapia Assistida por Computador , Glioma/diagnóstico por imagem , Glioma/radioterapia , Humanos , Imageamento por Ressonância Magnética/métodos , Aceleradores de Partículas , Estudos Prospectivos , Planejamento da Radioterapia Assistida por Computador/métodos
12.
Nat Commun ; 13(1): 1898, 2022 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-35393414

RESUMO

Recent advances in cancer therapeutics clearly demonstrate the need for innovative multiplex therapies that attack the tumour on multiple fronts. Oncolytic or "cancer-killing" viruses (OVs) represent up-and-coming multi-mechanistic immunotherapeutic drugs for the treatment of cancer. In this study, we perform an in-vitro screen based on virus-encoded artificial microRNAs (amiRNAs) and find that a unique amiRNA, herein termed amiR-4, confers a replicative advantage to the VSVΔ51 OV platform. Target validation of amiR-4 reveals ARID1A, a protein involved in chromatin remodelling, as an important player in resistance to OV replication. Virus-directed targeting of ARID1A coupled with small-molecule inhibition of the methyltransferase EZH2 leads to the synthetic lethal killing of both infected and uninfected tumour cells. The bystander killing of uninfected cells is mediated by intercellular transfer of extracellular vesicles carrying amiR-4 cargo. Altogether, our findings establish that OVs can serve as replicating vehicles for amiRNA therapeutics with the potential for combination with small molecule and immune checkpoint inhibitor therapy.


Assuntos
Vesículas Extracelulares , MicroRNAs , Neoplasias , Terapia Viral Oncolítica , Vírus Oncolíticos , Humanos , MicroRNAs/genética , Neoplasias/terapia , Vírus Oncolíticos/genética
13.
Clin Transplant ; 36(5): e14593, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35032351

RESUMO

BACKGROUND: Advanced age is considered a risk factor for lung transplantation (LTX). We sought to evaluate the long-term outcomes of LTX in the septuagenarian. METHODS: LTX recipients in the UNOS transplant registry (May 1, 2005-June 12, 2020) were stratified into 18-59, 60-69, and > = 70 years of age. Recipient and transplant characteristics were evaluated for survival, cause of death (COD), length of stay (LOS), and complications. A Kaplan-Meier analysis examined long-term survival for all patients stratified by age, specifically looking at cause of death. RESULTS: A total of 27 632 recipients were identified. As recipients aged, we found a decrease in proportion of cystic fibrosis and an increase in restrictive disease while obstructive disease peaked in the 60-69yo cohort (P < .001). Septuagenarians had higher rates of single LTX, male gender, and white race (P < .001). Older recipients had significantly longer donor recovery distances traveled with paradoxical shorter ischemic times, shorter hospital LOS and were transplanted at higher volume centers. There was no difference with in-hospital mortality among groups (P = .5). Acute rejection during initial hospitalization, rejection within 1 year, and post-transplant dialysis incidence decreased with age. Graft failure was a common COD in younger patients while malignancy and cardio/cerebrovascular diseases were common COD in > = 70yo. CONCLUSION: Select septuagenarian LTX candidates may be safely transplanted with relatively few complications. Immunosenescence and conditions of the aged are likely contributing factors to the decreased rejection and graft failure observations. Septuagenarians should not be excluded from LTX consideration based solely on age. Transplantation in septuagenarians should only be done in very selected patients (screened for malignancies and atherosclerotic disease) and these recipients should be carefully followed after transplantation because of these risk factors.


Assuntos
Transplante de Pulmão , Neoplasias , Idoso , Envelhecimento , Humanos , Incidência , Transplante de Pulmão/efeitos adversos , Masculino , Neoplasias/cirurgia , Sistema de Registros , Estudos Retrospectivos
14.
Transplant Proc ; 53(10): 3065-3068, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34756711

RESUMO

With the increased incidence and survival of lung transplant (LTx) recipients, the risk for chronic sequelae such as chronic kidney disease (CKD) is on the rise. Data on the long-term renal outcome are scarce. We performed a retrospective chart review of 171 adults with LTx from January 1, 2014, to January 1, 2019. Primary outcomes were prevalence of CKD/end-stage renal disease, acute kidney injury (AKI) as a risk factor for future CKD, and all-cause mortality in recipients with CKD compared with the non-CKD group. Secondary outcomes were frequency of utilization of modalities for CKD (urinalysis, imaging, biopsy, nephrology consultations). Baseline median creatinine and estimated glomerular filtration rate (eGFR) were 0.8 mg/dL and 90 mL/min/1.73 m2, respectively. Of the participants, 60% (96 of 161), 67% (102 of 153), 79% (37 of 47), 86% (10 of 12) had CKD at the end of 6, 12, 36, and 60 months, respectively, and 16% were on dialysis at the end of the study period; 3% received a subsequent renal transplant, and 27% mortality was noted over a 5-year follow-up period. The odds of CKD development in patients with an AKI during index hospitalization vs no AKI was 6.22 (2.87 to 13.06, P < .0001). The odds ratio of all-cause mortality in patients with CKD compared with non-CKD was 3.36 (95% confidence interval, 1.44-8.64, P = .005). Measurement of hematuria/proteinuria, imaging, and renal biopsy were infrequently used. Given the high prevalence of AKI and CKD in this population, a multidisciplinary team approach with an early nephrology consultation will be key to improve the overall and renal outcomes in LTx recipients.


Assuntos
Injúria Renal Aguda , Insuficiência Renal Crônica , Aloenxertos , Taxa de Filtração Glomerular , Humanos , Pulmão , Diálise Renal , Estudos Retrospectivos , Fatores de Risco , Transplantados
15.
Radiother Oncol ; 164: 155-162, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34592363

RESUMO

BACKGROUND AND PURPOSE: MRI linear accelerators (MR-Linacs) may allow treatment adaptation to be guided by quantitative MRI including diffusion-weighted imaging (DWI). The aim of this study was to evaluate the accuracy and precision of apparent diffusion coefficient (ADC) measurements from DWI on a 1.5 T MR-Linac in patients with central nervous system (CNS) tumours through comparison with a diagnostic scanner. MATERIALS AND METHODS: CNS patients were treated using a 1.5 T Elekta Unity MR-Linac. DWI was acquired during MR-Linac treatment and on a Philips Ingenia 1.5 T. The agreement between the two scanners on median ADC over the gross tumour/clinical target volumes (GTV/CTV) and in brain regions (white/grey matter, cerebrospinal fluid (CSF)) was computed. Repeated scans were used to estimate ADC repeatability. Daily changes in ADC over the GTV of high-grade gliomas were characterized from MR-Linac scans. RESULTS: DWI from 59 patients was analyzed. MR-Linac ADC measurements showed a small bias relative to Ingenia measurements in white matter, grey matter, GTV, and CTV (bias: -0.05 ± 0.03, -0.08 ± 0.05, -0.1 ± 0.1, -0.08 ± 0.07 µm2/ms). ADC differed substantially in CSF (bias: -0.5 ± 0.3 µm2/ms). The repeatability of MR-Linac ADC over white/grey matter was similar to previous reports (coefficients of variation for median ADC: 1.4%/1.8%). MR-Linac ADC changes in the GTV were detectable. CONCLUSIONS: It is possible to obtain ADC measurements in the brain on a 1.5 T MR-Linac that are comparable to those of diagnostic-quality scanners. This technical validation study adds to the foundation for future studies that will correlate brain tumour ADC with clinical outcomes.


Assuntos
Neoplasias Encefálicas , Neoplasias do Sistema Nervoso Central , Neoplasias Encefálicas/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Aceleradores de Partículas
16.
Radiother Oncol ; 162: 140-149, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34280403

RESUMO

PURPOSE: To describe the implementation and initial results of using Chemical Exchange Saturation Transfer (CEST) for monitoring patients with central nervous system (CNS) tumours treated using a 1.5 tesla MR-guided radiotherapy system. METHODS: CNS patients were treated with up to 30 fractions (total dose up to 60 Gy) using a 1.5 T Elekta Unity MR-Linac. CEST scans were obtained in 54 subjects at one or more time points during treatment. CEST metrics, including the amide magnetization transfer ratio (MTRAmide), nuclear Overhauser effect (NOE) MTR (MTRNOE) and asymmetry, were quantified in phantoms and CNS patients. The signal was investigated between tumour and white matter, across time, and across disease categories including high- and low-grade tumours. RESULTS: The gross tumour volume (GTV) exhibited lower MTRAmide and MTRNOE and higher asymmetry compared to contralateral normal appearing white matter. Signal changes in the GTV during fractionated radiotherapy were observed. There were differences between high- and low-grade tumours, with higher CEST asymmetry associated with higher grade disease. CONCLUSION: CEST MRI using a 1.5 T MR-Linac was demonstrated to be feasible for in vivo imaging of CNS tumours. CEST images showed tumour/white-matter contrast, temporal CEST signal changes, and associations with tumour grade. These results show promise for the eventual goal of using metabolic imaging to inform the design of adaptive radiotherapy protocols.


Assuntos
Neoplasias Encefálicas , Neoplasias do Sistema Nervoso Central , Substância Branca , Encéfalo , Neoplasias do Sistema Nervoso Central/diagnóstico por imagem , Neoplasias do Sistema Nervoso Central/radioterapia , Humanos , Imageamento por Ressonância Magnética , Imagens de Fantasmas
17.
Front Oncol ; 11: 634830, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34046341

RESUMO

Adaptive MR-guided radiotherapy (MRgRT) is a new treatment paradigm and its role as a non-invasive treatment option for renal cell carcinoma is evolving. The early clinical experience to date shows that real-time plan adaptation based on the daily MRI anatomy can lead to improved target coverage and normal tissue sparing. Continued technological innovations will further mitigate the challenges of organ motion and enable more advanced treatment adaptation, and potentially lead to enhanced oncologic outcomes and preservation of renal function. Future applications look promising to make a positive clinical impact and further the personalization of radiotherapy in the management of renal cell carcinoma.

18.
J Cancer Res Clin Oncol ; 147(5): 1365-1378, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33555379

RESUMO

PURPOSE: Mutations in BRAF are the most prominent activating mutations in melanoma and are increasingly recognized in other cancers. There is currently no accepted treatment regimen for patients with mutant BRAFK601N melanoma, and the study of melanoma driven by BRAF mutations at the 601 locus is lacking due to a paucity of cellular model systems. Therefore, we sought to better understand the treatment and clinical approach to patients with mutant BRAFK601N melanoma and subsequently develop a novel personalized oncology platform for rare or treatment-refractory cancers. METHODS: We developed and characterized the first patient-derived, naturally occurring BRAFK601N melanoma model, described herein as OHRI-MEL-13, and assessed efficacy using the Prestwick Chemical Library and select targeted therapeutics. RESULTS: OHRI-MEL-13 exhibits loss of heterozygosity of BRAF, closely mimics the original tumor's gene expression profile, is tumorigenic in immune-deficient murine models, and is available for public accession through American Type Culture Collection. We present in silico modeling data, which illustrates the therapeutic failure of BRAFV600E-targeted therapies in BRAFK601N mutants. Our platform elucidated a unique role for MEK inhibition with cobimetinib, which resulted in short-term clinical success by reducing the metastatic burden. CONCLUSION: Our model of BRAFK601N-activated melanoma was developed, thoroughly characterized, and made available for public accession. This model served to demonstrate the feasibility of a novel personalized oncology platform that could be optimized at an institutional level for rare variant or treatment-refractory cancers. We also demonstrate the clinical utility of monotherapy MEK inhibition in a case of BRAFK601N melanoma.


Assuntos
Antineoplásicos/farmacologia , Melanoma/tratamento farmacológico , Melanoma/genética , Proteínas Proto-Oncogênicas B-raf/genética , Neoplasias Cutâneas/tratamento farmacológico , Neoplasias Cutâneas/genética , Animais , Carcinogênese/efeitos dos fármacos , Carcinogênese/genética , Linhagem Celular Tumoral , Desenvolvimento de Medicamentos/métodos , Humanos , Camundongos , Camundongos Endogâmicos NOD , Camundongos Nus , Camundongos SCID , Mutação/genética , Medicina de Precisão , Transcriptoma/efeitos dos fármacos , Transcriptoma/genética
19.
Med Phys ; 48(5): e67-e85, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33577091

RESUMO

Over the last few years, magnetic resonance image-guided radiotherapy systems have been introduced into the clinic, allowing for daily online plan adaption. While quality assurance (QA) is similar to conventional radiotherapy systems, there is a need to introduce or modify measurement techniques. As yet, there is no consensus guidance on the QA equipment and test requirements for such systems. Therefore, this report provides an overview of QA equipment and techniques for mechanical, dosimetric, and imaging performance of such systems and recommendation of the QA procedures, particularly for a 1.5T MR-linac device. An overview of the system design and considerations for QA measurements, particularly the effect of the machine geometry and magnetic field on the radiation beam measurements is given. The effect of the magnetic field on measurement equipment and methods is reviewed to provide a foundation for interpreting measurement results and devising appropriate methods. And lastly, a consensus overview of recommended QA, appropriate methods, and tolerances is provided based on conventional QA protocols. The aim of this consensus work was to provide a foundation for QA protocols, comparative studies of system performance, and for future development of QA protocols and measurement methods.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radioterapia Guiada por Imagem , Campos Magnéticos , Imageamento por Ressonância Magnética , Aceleradores de Partículas , Imagens de Fantasmas , Radiometria , Planejamento da Radioterapia Assistida por Computador
20.
Transpl Infect Dis ; 23(3): e13518, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33217132

RESUMO

Lung transplant recipients are at increased risk for infection in the early postoperative phase, thus perioperative antibiotics are employed. This retrospective study evaluated the efficacy of short- vs long-course perioperative antibiotics in lung transplant patients. Lung transplant patients with donor positive cultures between August 2013 and September 2019 were evaluated, excluding those with cystic fibrosis, death within 14 days and re-transplants. The primary outcome was 30-day freedom from donor-derived respiratory infection. A total of 147 patients were included (57 short vs 90 long-course). Median perioperative antibiotic duration was 6 days in the short-course vs 14 days in the long-course group (P < .0001). Thirty-day freedom from donor-derived respiratory infection was present in 56 (98%) patients in the short-course vs 85 (94%) patients in the long-course group (P = .41). There was no difference in development of Clostridioides difficile infections (P = .41), while cumulative ventilator time and time to post-op extubation were longer in the long-course group (P = .001 and .004, respectively). Among lung transplant recipients with positive donor respiratory cultures, short-course perioperative antibiotics were as effective as long-course antibiotics in preventing donor-derived bacterial respiratory infections.


Assuntos
Transplante de Pulmão , Transplantados , Antibacterianos/uso terapêutico , Humanos , Pulmão , Estudos Retrospectivos , Doadores de Tecidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA