Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 153
Filtrar
1.
J Am Coll Cardiol ; 84(8): 766-770, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142732

RESUMO

This report describes a hybrid intervention addressing left circumflex artery occlusion during minimally invasive mitral valve repair. By using a radiopaque Cor-Knot device (LSI Solutions), targeted removal of occluding sutures was achieved, circumventing sternotomy and coronary artery bypass. Real-time coronary angiography provided assessment of procedural success during surgical revision in a hybrid operating room.


Assuntos
Oclusão Coronária , Procedimentos Cirúrgicos Minimamente Invasivos , Insuficiência da Valva Mitral , Humanos , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Oclusão Coronária/cirurgia , Oclusão Coronária/etiologia , Oclusão Coronária/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Masculino , Angiografia Coronária , Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Feminino , Complicações Pós-Operatórias/etiologia , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/métodos , Intervenção Coronária Percutânea/efeitos adversos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38970376

RESUMO

OBJECTIVES: The goal of this study was to investigate the impact of onset-to-cut time on mortality in patients undergoing surgery for stable acute type A aortic dissection. METHODS: Patients who underwent surgery for acute type A aortic dissection between January 2006 and December 2021 and available onset-to-cut times were included. Patients with unstable aortic dissection (preoperative shock, intubation, resuscitation, coma, pericardial tamponade and local/systemic malperfusion syndromes) were excluded. After descriptive analysis, a multivariable binary logistic regression for 30-day mortality was performed. A receiver operating characteristic curve for onset-to-cut time and 30-day mortality was calculated. Restricted cubic splines were designed to investigate the association between onset-to-cut time and survival. RESULTS: The final cohort comprised 362 patients. The median onset-to-cut time was 543 (376-1155) min. The 30-day mortality was 9%. Only previous myocardial infarction (P = 0.018) and prolonged cardiopulmonary bypass time (P < 0.001) were identified as independent risk factors for 30-day mortality. The corresponding area under the receiver operating characteristic curve showed a value of 0.49. Restricted cubic splines did not indicate an association between onset-to-cut time and survival (P = 0.316). CONCLUSIONS: Onset-to-cut time in the setting of stable acute type A aortic dissection does not seem to be a valid predictor of 30-day mortality in patients undergoing surgery and stayed stable during the preoperative course.

3.
Eur J Cardiothorac Surg ; 66(1)2024 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-38905500

RESUMO

OBJECTIVES: Managing acute type A aortic dissection with coronary malperfusion is challenging. This study outlines our revascularization strategy for these patients. METHODS: Patients undergoing surgery for acute type A aortic dissection with coronary malperfusion and aortic root involvement from January 2000 to December 2021 were included. Patients were classified using the Neri classification for coronary dissection, including a novel 'Neri -' class (no coronary dissection). Patients undergoing revascularization either as a planned or as a bailout strategy due to persisting low cardiac output were compared additionally. RESULTS: The cohort comprised 195 patients: 43 (22%) Neri -, 43 (22%) Neri A, 74 (38%) Neri B and 35 (18%) Neri C. Aortic root replacement was mainly performed in 25 Neri C patients (71%; P < 0.001). Concomitant bypass surgery was performed in 4 (9%) of Neri -, 5 (12%) of Neri A, 21 (28%) of Neri B and 32 (91%) of Neri C patients (P < 0.001). Thirty-day mortality was 42% with 21 (49%) Neri -, 12 (28%) Neri A, 30 (41%) Neri B and 19 (54%) Neri C patients (P = 0.087). Bailout revascularization was primarily performed in 11 Neri B patients (69%; P = 0.001) and associated with a higher 30-day mortality of 81% compared to 48% for planned revascularization (P = 0.042). CONCLUSIONS: Postoperative outcomes in case of coronary malperfusion are poor, irrespective of the anatomic dissection pattern. The decision for concomitant bypass surgery is crucial but may be considered in Neri C patients combined with aortic root replacement. Bailout revascularization was most common in Neri B and showed dismal outcome.


Assuntos
Dissecção Aórtica , Ponte de Artéria Coronária , Humanos , Dissecção Aórtica/cirurgia , Dissecção Aórtica/complicações , Masculino , Ponte de Artéria Coronária/métodos , Feminino , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Doença Aguda , Resultado do Tratamento , Aneurisma da Aorta Torácica/cirurgia , Aneurisma da Aorta Torácica/complicações
4.
Eur J Cardiothorac Surg ; 65(6)2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38814808

RESUMO

OBJECTIVES: The aim of this study was to evaluate the outcomes of transposition of the omentum into the mediastinum to support the replacement of infected aortic grafts or to cover infected aortic grafts that are not amenable for surgical replacement. METHODS: All patients with thoracic aortic graft infections who underwent mediastinal transposition of the omentum at our institution between 2005 and 2023 were included in this study. Mediastinal transposition of the omentum was performed either after replacement of the infected graft ('curative concept') or solely as bailout procedure by wrapping the infected graft ('palliative concept'). The diagnosis, including computed tomography scans during follow-up, was made according to the criteria of the Management of Aortic Graft Infection Collaboration. RESULTS: The patient cohort consisted of 31 patients. Both in-hospital and 1-year mortality were 0% (n = 0) for the curative concept (n = 9) compared to 23% (n = 5) and 41% (n = 9) for the palliative concept (n = 22), respectively. There was no graft infection-associated death or recurrence of infection after 3 years in the curative group. Survival was 52% at 3 years in the palliative group, with freedom of infection in 59% of the patients (n = 13). CONCLUSIONS: Transposition of the omentum and wrapping of the infected aortic prosthetic graft is a useful bailout strategy for patients who are ineligible for replacement of an infected aortic graft. However, mortality stays high. For radical treatment of aortic graft infections, it may prove an effective supportive therapy and represents an important tool in the armamentarium of cardiac surgeons.


Assuntos
Aorta Torácica , Aorta , Prótese Vascular , Mediastino , Omento , Infecções Relacionadas à Prótese , Humanos , Omento/transplante , Omento/cirurgia , Masculino , Feminino , Infecções Relacionadas à Prótese/cirurgia , Aorta Torácica/cirurgia , Aorta Torácica/diagnóstico por imagem , Pessoa de Meia-Idade , Idoso , Prótese Vascular/efeitos adversos , Estudos Retrospectivos , Aorta/cirurgia , Mediastino/cirurgia , Implante de Prótese Vascular/métodos , Resultado do Tratamento , Adulto , Tomografia Computadorizada por Raios X
5.
J Clin Med ; 13(9)2024 Apr 28.
Artigo em Inglês | MEDLINE | ID: mdl-38731123

RESUMO

The treatment of DeBakey type I aortic dissection remains a major challenge in the field of aortic surgery. To upgrade the standard of care hemiarch replacement, a novel device called an "Ascyrus Medical Dissection Stent" (AMDS) is now available. This hybrid device composed of a proximal polytetrafluoroethylene cuff and a distal non-covered nitinol stent is inserted into the aortic arch and the descending thoracic aorta during hypothermic circulatory arrest in addition to hemiarch replacement. Due to its specific design, it may result in a reduced risk for distal anastomotic new entries, the effective restoration of branch vessel malperfusion and positive aortic remodeling. In this narrative review, we provide an overview about the indications and the technical use of the AMDS. Additionally, we summarize the current available literature and discuss potential pitfalls in the application of the AMDS regarding device failure and aortic re-intervention.

6.
Artigo em Inglês | MEDLINE | ID: mdl-38627244

RESUMO

We evaluated the feasibility of harvesting bilateral internal thoracic arteries with the da Vinci Single Port system (SP) through a single left-sided subcostal incision. Complete bilateral mobilization with sufficiently long conduits for multivessel grafting was possible in 2 human cadavers and 2 live porcine. Creating the subcostal access and docking the SP system took between 14 and 21 min and the total harvest time ranged from 65 to 125 min in all models. No major bleeding was observed in the live porcine and hemostasis was managed with the available instrumentation. One porcine deceased during surgery due to ventricular fibrillation followed by cardiac arrest. The robotic harvesting was technically easily reproduced by the surgeons and required no additional rib-spreading. Further studies will be required to assess if this subcostal approach with the da Vinci SP system yields true clinical benefits in patients.

7.
Artigo em Inglês | MEDLINE | ID: mdl-38630154

RESUMO

Aim of this study was to compare redo MV surgery patients undergoing right mini-thoracotomy and EAC with redo MV patients undergoing surgery through other approaches. Redo MV patients from 7 European centers were analyzed. Primary endpoint was 30-day mortality; secondary endpoints were stroke, re-exploration, low cardiac output syndrome (LCOS), respiratory failure, and intensive care unit (ICU) and in-hospital length-of-stay. Forty-nine patients underwent right mini-thoracotomy and EAC (22.7%), and 167 (77.3%) underwent surgery through other approaches (112 sternotomy, 40 unclamped mini-thoracotomies, and 15 mini-thoracotomies with trans-thoracic clamp). Thirty-day mortality, stroke, re-exploration for bleeding, and weaning failure were comparable. The EAC group showed significant lower rate of LCOS (p = 0.03) and shorter ICU (p = 0.04) and in-hospital length of stay (p = 0.002). The EAC allows the surgeon to reach the aorta, to clamp it, and to deliver the cardioplegia with a "no-touch" technique, with significant improvement in outcomes.

9.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artigo em Inglês | MEDLINE | ID: mdl-38598445

RESUMO

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Assuntos
Dissecção Aórtica , Implante de Prótese Vascular , Stents , Humanos , Dissecção Aórtica/cirurgia , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Procedimentos Endovasculares/métodos , Procedimentos Endovasculares/efeitos adversos , Doença Aguda , Desenho de Prótese , Aneurisma da Aorta Torácica/cirurgia , Resultado do Tratamento , Aneurisma Aórtico/cirurgia
11.
JTCVS Open ; 17: 64-71, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420545

RESUMO

Objective: Randomized evidence suggests a high risk of pacemaker implantation for patients undergoing mitral valve (MV) surgery with concomitant tricuspid valve repair (cTVR). We investigated the impact of cTVR on outcomes in the Mini-Mitral International Registry. Methods: From 2015 to 2021, 7513 patients underwent minimally invasive MV with or without cTVR in 17 international centers (MV: n = 5609, cTVR: n = 1113). Propensity matching generated 1110 well-balanced pairs. Multivariable analysis was applied. Results: Patients with cTVR were older and had more comorbidities. Propensity matching eliminated most differences except for more TR in patients who underwent cTVR (77.2% vs 22.1% MV, P < .001). Mean matched age was 71 years, and 45% were male. European System for Cardiac Operative Risk Evaluation II was still 2.68% (interquartile range [IQR], 0.80-2.63) vs 1.9% (IQR, 1.12-3.9) in matched MV (P < .001). MV replacement (30%) and atrial fibrillation surgery (32%) were similar in both groups. Cardiopulmonary bypass (161 minutes [IQR, 133-203] vs MV: 130 minutes [IQR, 103-166]; P < .001) and crossclamp times (93 minutes [IQR, 66-123] vs MV: 83 minutes [IQR, 64-107]; P < .001) were longer with cTVR. Although in-hospital mortality was similar (cTVR: 3.3% vs MV: 2.2%; P = .5), postoperative pacemaker implantations (9% vs MV: 5.8%; P = .02), low cardiac output syndrome (7.7% vs MV: 4.4%; P = .02), and acute kidney injury (13.8% vs MV: 10%; P = .01) were more frequent with cTVR. cTVR eliminated relevant TR in most patients (greater-than-moderate TR: 6.8%). Multivariable analysis identified MV replacement, atrial fibrillation, and cTVR as risk factors of postoperative pacemaker implantation. Conclusions: cTVR in minimally invasive MV surgery is an independent risk factor for pacemaker implantation in this international registry. It is also associated with more bleeding, low output syndrome, and acute kidney injury. It remains unclear whether technical or patient factors (or both) explain these differences.

12.
Eur J Cardiothorac Surg ; 65(1)2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38175777

RESUMO

OBJECTIVES: Cardiopulmonary resuscitation (CPR) aggravates the pre-existing dismal prognosis of patients suffering from acute type A aortic dissection (ATAAD). We aimed to identify factors affecting survival and outcome in ATAAD patients requiring CPR at presentation at 2 European aortic centres. METHODS: Data on 112 surgical candidates and undergoing preoperative CPR were retrospectively evaluated. Patients were divided into 2 groups according to 30-day mortality. A multivariable model identified predictors for 30-day mortality. RESULTS: Preoperative death occurred in 23 patients (20.5%). In the remaining 89 surgical patients (79.5%) circulatory arrest time (41 ± 20 min in 30-day non-survivors vs 30 ± 13 min in 30-day survivor, P = 0.003) as well as cardiopulmonary bypass time (320 ± 132 min in 30-day non-survivors vs 252 ± 140 min in 30-day survivor, P = 0.020) time was significantly longer in patients with worse outcome. Thirty-day mortality of the total cohort was 61.6% (n = 69) with cardiac failure in 48% and aortic rupture or haemorrhagic shock (28%) as predominant reasons of death. Age [odds ratio (OR) 1.04, 95% confidence interval (CI) 1.01-1.09, P = 0.034], preoperative coronary (OR 3.42, 95% CI 1.34-9.26, p = 0.012) and spinal malperfusion (OR 12.49, 95% CI 1.83-225.02, P = 0.028) emerged as independent predictors for 30-day mortality while CPR due to tamponade was associated with improved early survival (OR 0.29, 95% CI 0.091-0.81, P = 0.023). CONCLUSIONS: Assessment of underlying cause for CPR is mandatory. Pericardial tamponade, rapidly resolved with pericardial drainage, is a predictor for improved survival, while age and presence of coronary and spinal malperfusion are associated with dismal outcome in this high-risk patient group.


Assuntos
Dissecção Aórtica , Reanimação Cardiopulmonar , Humanos , Resultado do Tratamento , Estudos Retrospectivos , Dissecção Aórtica/complicações , Dissecção Aórtica/cirurgia , Prognóstico , Fatores de Risco , Doença Aguda
13.
Eur J Cardiothorac Surg ; 65(3)2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38273702

RESUMO

OBJECTIVES: Aortic valve regurgitation (AR) frequently complicates the clinical course after left ventricular assist device (LVAD) implantation. Transcatheter aortic valve implantation (TAVI) has emerged as an alternative to surgical aortic valve replacement (SAVR) in this cohort with a mostly high surgical risk profile. The unique challenges in LVAD patients, such as presence of non-calcified aortic valves and annular dilatation, raise concerns about device migration and paravalvular leakage (PVL) leading to missing device success. This study evaluates procedural outcomes and survival rates in LVAD patients who underwent TAVI, emphasizing strategies to enhance device success. METHODS: Between January 2017 and April 2023, 27 LVAD patients with clinically significant AR underwent elective or urgent TAVI at our centre. Primary end-points were procedural success rates, without the need for a second transcatheter heart valve (THV) and postprocedural AR/PVL. Secondary outcomes included survival rates and adverse events. RESULTS: Among the cohort, 14.8% received AR-dedicated TAVI devices, with none requiring a second THV. There was no intraprocedural AR, and 1 patient (25%) had AR > 'trace' at discharge. Additionally, 25.9% underwent device landing zone (DLZ) pre-stenting with a standard TAVI device, all without needing a second THV. There was no intraprocedural AR, and none to trace AR at discharge. Among the 59.3% receiving standard TAVI devices, 37.5% required a second THV. In this subgroup, intraprocedural AR > 'trace' occurred in 12.5%, decreasing to 6.25% at discharge. In-hospital mortality was 3.7%, and median follow-up survival was 388 days (interquartile range 208-1167 days). CONCLUSIONS: TAVI yields promising procedural outcomes and early survival rates in LVAD patients with AR. Tailored TAVI devices and pre-stenting techniques enhance procedural success. Continued research into these strategies is essential to optimize outcomes in this complex patient cohort.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Coração Auxiliar , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Coração Auxiliar/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos
14.
Front Cardiovasc Med ; 10: 1299192, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034371

RESUMO

Introduction: Open surgical repair remains the current gold standard for the treatment of acute type A aortic dissection. However, especially elderly patients with relevant comorbidities who are deemed unfit for open surgery may benefit from a minimally invasive endovascular approach. Methods: We report a case of an 80-year-old male with retrograde acute type A aortic dissection and peripheral malperfusion after receiving thoracic endovascular aortic repair due to thoracic aortic aneurysm. Our individualized endovascular approach consisted of left carotid-subclavian bypass, proximal extension of thoracic endovascular aortic repair using a covered stent graft and a single covered stent graft for the ascending aorta in combination with an uncovered stent for the aortic arch. Results: Postoperative computed tomographic angiography demonstrated excellent outcome with no signs of endoleak or patent false lumen. Follow-up after 3.5 years showed a stable result with no signs of stent failure or dissection progress. No aortic re-interventions were needed in the further course. Discussion: An individualized endovascular approach may be justified for acute type A aortic dissection in elderly patients with high surgical risk if performed in specialized aortic centers. Additional short-length stent graft devices are needed to address the anatomical challenges of the ascending aorta. For enhanced remodeling of the dissected aorta, the use of an additional uncovered stent may be advisable.

15.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37812223

RESUMO

OBJECTIVES: The aim of this study was to examine the incidence and predictors of stroke after minimally invasive mitral valve surgery (mini-MVS) and to assess the role of preoperative CT scan on surgical management and neurological outcomes in the large cohort of Mini-Mitral International Registry. METHODS: Clinical, operative and in-hospital outcomes in patients undergoing mini-MVS between 2015 and 2021 were collected. Univariable and multivariable analyses were used to identify predictors of stroke. Finally, the impact of preoperative CT scan on surgical management and neurological outcomes was assessed. RESULTS: Data from 7343 patients were collected. The incidence of stroke was 1.3% (n = 95/7343). Stroke was associated with higher in-hospital mortality (11.6% vs 1.5%, P < 0.001) and longer intubation time, ICU and hospital stay (median 26 vs 7 h, 120 vs 24 h and 14 vs 8 days, respectively). On multivariable analysis, age (odds ratio 1.039, 95% confidence interval 1.019-1.060, P < 0.001) and mitral valve replacement (odds ratio 2.167, 95% confidence interval 1.401-3.354, P < 0.001) emerged as independent predictors of stroke. Preoperative CT scan was made in 31.1% of cases. These patients had a higher risk profile and EuroSCORE II (median 1.58 vs 1.1, P < 0.001). CT scan influenced the choice of cannulation site, being ascending aorta (18.5% vs 0.5%, P < 0.001) more frequent in the CT group and femoral artery more frequent in the no CT group (97.8% vs 79.7%, P < 0.001). No difference was found in the incidence of postoperative stroke (CT group 1.5, no CT group 1.4%, P = 0.7). CONCLUSIONS: Mini-MVS is associated with a low incidence of stroke, but when it occurs it has an ominous impact on mortality. Preoperative CT scan affected surgical cannulation strategy but did not led to improved neurological outcomes.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Acidente Vascular Cerebral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Esternotomia/efeitos adversos , Procedimentos Cirúrgicos Minimamente Invasivos/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento , Implante de Prótese de Valva Cardíaca/efeitos adversos
17.
Eur J Cardiothorac Surg ; 64(4)2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37589652

RESUMO

OBJECTIVES: The aim of this study is to investigate the outcome of elderly patients with surgically treated acute type A aortic dissection (ATAAD) complicated by malperfusion. METHODS: Patients ≥70 years old who underwent surgical treatment for ATAAD between January 2000 and December 2020 were enrolled in this study and stratified by their specific Penn Classification into 4 different subgroups, where Penn Abc was defined as multilevel malperfusion. Short- and long-term outcomes were investigated. Multivariable binary logistic regression was performed to identify risk factors for 1-year mortality. RESULTS: Four hundred elderly patients underwent surgical treatment for ATAAD. A total of 204 (51%) patients had no evidence of malperfusion (Penn Aa), 106 (26.5%) had localized organic malperfusion (Penn Ab), 44 (11%) patients had systemic malperfusion (Penn Ac) and 46 (11.5%) suffered from multilevel malperfusion (Penn Abc). For the latter, in-hospital mortality was 70% (P < 0.001). Age (P < 0.006) and multilevel malperfusion (P < 0.001) were independent risk factors for 1-year mortality. Patients with multilevel malperfusion showed the worst 1-year survival (P < 0.001). In the case of Penn Aa, in-hospital mortality was 13% (P < 0.001). CONCLUSIONS: Surgery may lead to satisfactory results in the absence of malperfusion, even in octogenarians. Elderly patients with multilevel malperfusion show very poor surgical outcome. In these patients, the decision for surgery should be taken with caution. Operation, if performed, should be carried out by experienced teams only.


Assuntos
Dissecção Aórtica , Idoso de 80 Anos ou mais , Humanos , Idoso , Resultado do Tratamento , Dissecção Aórtica/cirurgia , Fatores de Risco , Mortalidade Hospitalar , Doença Aguda , Estudos Retrospectivos
18.
Heart ; 109(18): 1394-1400, 2023 08 24.
Artigo em Inglês | MEDLINE | ID: mdl-37376817

RESUMO

OBJECTIVE: Ventricular secondary mitral regurgitation (SMR) (Carpentier type IIIb) results from left ventricular (LV) remodelling, displacement of papillary muscles and tethering of mitral leaflets. The most appropriate treatment approach remains controversial. We aimed to assess the safety and efficacy of standardised relocation of both papillary muscles (subannular repair) at 1-year follow-up (FU). METHODS: REFORM-MR (Reform-Mitral Regurgitation) is a prospective, multicentre registry that enrolled consecutive patients with ventricular SMR (Carpentier type IIIb) undergoing standardised subannular mitral valve (MV) repair in combination with annuloplasty at five sites in Germany. Here, we report survival, freedom from recurrence of MR >2+, freedom from major adverse cardiac and cerebrovascular events (MACCEs), including cardiovascular death, myocardial infarction, stroke, MV reintervention and echocardiographic parameters of residual leaflet tethering at 1-year FU. RESULTS: A total of 94 patients (69.1% male) with a mean age of 65.1±9.7 years met the inclusion criteria. Advanced LV dysfunction (mean left ventricular ejection fraction 36.4±10.5%) and severe LV dilatation (mean left ventricular end-diastolic diameter 61.0±9.3 mm) resulted in severe mitral leaflet tethering (mean tenting height 10.6±3.0 mm) and an elevated mean EURO Score II of 4.8±4.6 prior to surgery. Subannular repair was successfully performed in all patients, without operative mortality or complications. One-year survival was 95.5%. At 12 months, a durable reduction of mitral leaflet tethering resulted in a low rate (4.2%) of recurrent MR >2+. In addition to a significant improvement in New York Heart Association (NYHA) class (22.4% patients in NYHA III/IV vs 64.5% patients at baseline, p<0.001), freedom from MACCE was observed in 91.1% of patients. CONCLUSIONS: Our study demonstrates the safety and feasibility of standardised subannular repair to treat ventricular SMR (Carpentier type IIIb) in a multicentre setting. By addressing mitral leaflet tethering, papillary muscle relocation results in very satisfactory 1-year outcomes and has the potential to durably restore MV geometry; nevertheless, long-term FU is mandatory. TRIAL REGISTRATION NUMBER: NCT03470155.


Assuntos
Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Estudos Prospectivos , Volume Sistólico , Sístole , Resultado do Tratamento , Função Ventricular Esquerda
19.
Artigo em Inglês | MEDLINE | ID: mdl-37279727

RESUMO

Transaxillary implantation of a temporary microaxial left ventricular assist device in patients suffering from cardiogenic shock is an established technique. We present a 77-year-old female patient with severe mitral regurgitation. She underwent minimally invasive surgical mitral valve replacement. After an uneventful postoperative course, the patient developed acute heart failure on the 11th postoperative day. Transthoracic echocardiography revealed new onset of Takotsubo cardiomyopathy with a severely decreased left ventricular ejection fraction. Implantation of a microaxial flow pump for left ventricular decompression was scheduled. Preoperative computed tomography revealed a rectangular course of the right subclavian artery. To advance the Impella, we employed an introducer fitted over the guidewire behind the Impella device as a 'cue stick' to move the rigid part of the pump forward to overcome the kinking using a 'shuffleboard technique'. The haemodynamic situation stabilized immediately after implantation. The Impella 5.5 was successfully weaned after 6 days of support. In the event of (rectangular) kinking of the subclavian artery, the 'shuffleboard technique' can be used for the successful positioning of the pump.

20.
Eur J Cardiothorac Surg ; 64(1)2023 07 03.
Artigo em Inglês | MEDLINE | ID: mdl-37233202

RESUMO

OBJECTIVES: Annuloplasty rings are routinely used in mitral valve repair (MVr). However, accurate annuloplasty ring size selection is essential to obtain a favourable outcome. Moreover, ring sizing can be challenging in some patients and is highly influenced by surgeons' experience. This study investigated the utility of three-dimensional mitral valve (3D-MV) reconstruction models to predict annuloplasty ring size for MVr. METHODS: A total of 150 patients undergoing minimally invasive MVr with annuloplasty ring due to Carpentier type II pathology and who were discharged with none/trace residual mitral regurgitation were included. 3D-MV reconstruction models were created with a semi-automated software package (4D MV Analysis) to quantitate mitral valve geometry. To predict the ring size, univariable and multivariable linear regression analyses were performed. RESULTS: Between 3D-MV reconstruction values and implanted ring sizes, the highest correlation coefficients were provided by commissural width (CW) (0.839; P < 0.001), intertrigonal distance (ITD) (0.796; P < 0.001), annulus area (0.782; P < 0.001), anterior mitral leaflet area (0.767; P < 0.001), anterior-posterior diameter (0.679; P < 0.001) and anterior mitral leaflet length (0.515; P < 0.001). In multivariable regression analysis, only CW and ITD were found to be independent predictors of annuloplasty ring size (R2 = 0.743; P < 0.001). The highest level of agreement was achieved with CW and ITD, and 76.6% of patients received a ring with no >1 ring size difference from the predicted ring sizes. CONCLUSIONS: 3D-MV reconstruction models can support surgeons in the decision-making process for annuloplasty ring sizing. The present study may be a first step towards accurate annuloplasty ring size prediction using multimodal machine learning decision support.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/patologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/patologia , Procedimentos Cirúrgicos Cardíacos/métodos , Valva Tricúspide/cirurgia , Anuloplastia da Valva Mitral/efeitos adversos , Anuloplastia da Valva Mitral/métodos , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA