Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
1.
Ophthalmology ; 126(11): 1517-1526, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31471088

RESUMO

PURPOSE: Neodymium:yttrium-aluminum-garnet (Nd:YAG) laser treatment is performed on vitreous floaters, but studies of structural and functional effects with objective outcome measures are lacking. This study evaluated Nd:YAG laser effects by comparing participants with vitreous floaters who previously underwent laser treatment with untreated control participants and healthy persons without vitreous floaters using quantitative ultrasonography to evaluate vitreous structure and by measuring visual acuity and contrast sensitivity function to assess vision. DESIGN: Retrospective, comparative study. PARTICIPANTS: One eye was enrolled for each of 132 participants: 35 control participants without vitreous floaters, 59 participants with untreated vitreous floaters, and 38 participants with vitreous floaters previously Nd:YAG-treated. Of these, 25 were dissatisfied and sought vitrectomy; 13 were satisfied with observation. METHODS: The 39-item National Eye Institute Visual Function Questionnaire (NEI-VFQ-39) to assess participant visual well-being, quantitative ultrasonography (QUS) to measure vitreous echodensity, and best-corrected visual acuity (BCVA) and contrast sensitivity function (CSF) to evaluate vision. MAIN OUTCOME MEASURES: Results of NEI-VFQ-39, QUS, BCVA, and CSF. RESULTS: Compared with control participants without vitreous floaters, participants with untreated vitreous floaters showed worse NEI-VFQ-39 results, 57% greater vitreous echodensity, and significant (130%) CSF degradation (P < 0.001 for each). Compared with untreated eyes with vitreous floaters, Nd:YAG-treated eyes had 23% less vitreous echodensity (P < 0.001), but no differences in NEI-VFQ-39 (P = 0.51), BCVA (P = 0.42), and CSF (P = 0.17) results. Of 38 participants with vitreous floaters who previously were treated with Nd:YAG, 25 were dissatisfied and seeking vitrectomy, whereas 13 were satisfied with observation. Participants seeking vitrectomy showed 24% greater vitreous echodensity (P = 0.018) and 52% worse CSF (P = 0.006). Multivariate linear regression models confirmed these findings. CONCLUSIONS: As a group, participants previously treated with Nd:YAG laser for bothersome vitreous floaters showed less dense vitreous, but similar visual function as untreated control participants with vitreous floaters. Because some treated eyes showed less dense vitreous and better visual function than those of untreated control participants, a prospective randomized study of Nd:YAG laser treatment of vitreous is warranted, using uniform laser treatment parameters and objective quantitative outcome measures.


Assuntos
Oftalmopatias/cirurgia , Lasers de Estado Sólido/uso terapêutico , Acuidade Visual/fisiologia , Corpo Vítreo/diagnóstico por imagem , Corpo Vítreo/cirurgia , Adulto , Idoso , Sensibilidades de Contraste/fisiologia , Oftalmopatias/diagnóstico por imagem , Oftalmopatias/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Oftalmoscopia , Satisfação do Paciente/estatística & dados numéricos , Estudos Retrospectivos , Perfil de Impacto da Doença , Inquéritos e Questionários , Ultrassonografia , Vitrectomia , Corpo Vítreo/fisiopatologia
2.
Artigo em Inglês | MEDLINE | ID: mdl-21902166

RESUMO

The vitreous body is nearly transparent both optically and ultrasonically. Conventional 10- to 12-MHz diagnostic ultrasound can detect vitreous inhomogeneities at high gain settings, but has limited resolution and sensitivity, especially outside the fixed focal zone near the retina. To improve visualization of faint intravitreal fluid/gel interfaces, the authors fabricated a spherically curved 20-MHz five-element annular array ultrasound transducer, implemented a synthetic-focusing algorithm to extend the depth-of-field, and used a pulse-encoding strategy to increase sensitivity. The authors evaluated a human subject with a recent posterior vitreous detachment and compared the annular array with conventional 10-MHz ultrasound and spectral-domain optical coherence tomography. With synthetic focusing and chirp pulse-encoding, the array allowed visualization of the formed and fluid components of the vitreous with improved sensitivity and resolution compared with the conventional B-scan. Although optical coherence tomography allowed assessment of the posterior vitreoretinal interface, the ultrasound array allowed evaluation of the entire vitreous body.


Assuntos
Técnicas de Diagnóstico Oftalmológico/instrumentação , Ultrassonografia/instrumentação , Corpo Vítreo/diagnóstico por imagem , Descolamento do Vítreo/diagnóstico por imagem , Algoritmos , Desenho de Equipamento , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia de Coerência Óptica , Transdutores
3.
Cancer Biomark ; 3(1): 1-33, 2007.
Artigo em Inglês | MEDLINE | ID: mdl-17655039

RESUMO

The concept of intraepithelial neoplasm (IEN) as a near-obligate precursor of cancers has generated opportunities to examine drug or device intervention strategies that may reverse or retard the sometimes lengthy process of carcinogenesis. Chemopreventive agents with high therapeutic indices, well-monitored for efficacy and safety, are greatly needed, as is development of less invasive or minimally disruptive visualization and assessment methods to safely screen nominally healthy but at-risk patients, often for extended periods of time and at repeated intervals. Imaging devices, alone or in combination with anticancer drugs, may also provide novel interventions to treat or prevent precancer.


Assuntos
Diagnóstico por Imagem/métodos , Neoplasias/prevenção & controle , Lesões Pré-Cancerosas/prevenção & controle , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias/diagnóstico , Lesões Pré-Cancerosas/diagnóstico
4.
Med Phys ; 34(3): 1037-46, 2007 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-17441250

RESUMO

A theoretical model is described for application in ultrasonic tissue characterization using a calibrated 2-D spectrum analysis method. This model relates 2-D spectra computed from ultrasonic backscatter signals to intrinsic physical properties of tissue microstructures, e.g., size, shape, and acoustic impedance. The model is applicable to most clinical diagnostic ultrasound systems. Two experiments employing two types of tissue architectures, spherical and cylindrical scatterers, are conducted using ultrasound with center frequencies of 10 and 40 MHz, respectively. Measurements of a tissue-mimicking phantom with an internal suspension of microscopic glass beads are used to validate the theoretical model. Results from in vitro muscle fibers are presented to further elucidate the utility of 2-D spectrum analysis in ultrasonic tissue characterization.


Assuntos
Neoplasias/diagnóstico , Análise Espectral/métodos , Ultrassom , Ultrassonografia/instrumentação , Ultrassonografia/métodos , Algoritmos , Animais , Bovinos , Humanos , Interpretação de Imagem Assistida por Computador , Modelos Estatísticos , Modelos Teóricos , Músculos/patologia , Neoplasias/patologia , Distribuição Normal , Reconhecimento Automatizado de Padrão , Imagens de Fantasmas , Análise Espectral/instrumentação
5.
Ultrasound Med Biol ; 32(11): 1743-51, 2006 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17112960

RESUMO

Spectral parameter imaging in both the fundamental and harmonic of backscattered radio-frequency (RF) data were used for immediate visualization of high-intensity focused ultrasound (HIFU) lesion sites. A focused 5-MHz HIFU transducer with a coaxial 9-MHz focused single-element diagnostic transducer was used to create and scan lesions in chicken breast and freshly excised rabbit liver. B-mode images derived from the backscattered RF signal envelope were compared with midband fit (MBF) spectral parameter images in the fundamental (9-MHz) and harmonic (18-MHz) bands of the diagnostic probe. Images of HIFU-induced lesions derived from the MBF to the calibrated spectrum showed improved contrast (approximately 3 dB) of tumor margins versus surround compared with images produced from the conventional signal envelope. MBF parameter images produced from the harmonic band showed higher contrast in attenuated structures (core, shadow) compared with either the conventional envelope (3.3 dB core; 11.6 dB shadow) or MBF images of the fundamental band (4.4 dB core; 7.4 dB shadow). The gradient between the lesion and surround was 3.4 dB/mm, 6.9 dB/mm and 17.2 dB/mm for B-mode, MBF-fundamental mode and MBF-harmonic mode, respectively. Images of threshold and "popcorn" lesions produced in freshly excised rabbit liver were most easily visualized and boundaries best-defined using MBF-harmonic mode.


Assuntos
Terapia por Ultrassom/métodos , Animais , Galinhas , Processamento de Imagem Assistida por Computador/métodos , Fígado/diagnóstico por imagem , Músculo Esquelético/diagnóstico por imagem , Coelhos , Transdutores , Terapia por Ultrassom/instrumentação , Ultrassonografia
6.
Ultrason Imaging ; 26(3): 163-72, 2004 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-15754797

RESUMO

Because current methods of imaging prostate cancer are inadequate, biopsies cannot be effectively guided and treatment cannot be effectively planned and targeted. Therefore, our research is aimed at ultrasonically characterizing cancerous prostate tissue so that we can image it more effectively and thereby provide improved means of detecting, treating and monitoring prostate cancer. We base our characterization methods on spectrum analysis of radiofrequency (rf) echo signals combined with clinical variables such as prostate-specific antigen (PSA). Tissue typing using these parameters is performed by artificial neural networks. We employed and evaluated different approaches to data partitioning into training, validation, and test sets and different neural network configuration options. In this manner, we sought to determine what neural network configuration is optimal for these data and also to assess possible bias that might exist due to correlations among different data entries among the data for a given patient. The classification efficacy of each neural network configuration and data-partitioning method was measured using relative-operating-characteristic (ROC) methods. Neural network classification based on spectral parameters combined with clinical data generally produced ROC-curve areas of 0.80 compared to curve areas of 0.64 for conventional transrectal ultrasound imaging combined with clinical data. We then used the optimal neural network configuration to generate lookup tables that translate local spectral parameter values and global clinical-variable values into pixel values in tissue-type images (TTIs). TTIs continue to show cancerous regions successfully, and may prove to be particularly useful clinically in combination with other ultrasonic and nonultrasonic methods, e.g., magnetic-resonance spectroscopy.


Assuntos
Redes Neurais de Computação , Neoplasias da Próstata/patologia , Ultrassonografia de Intervenção , Biópsia , Humanos , Masculino , Planejamento de Assistência ao Paciente , Antígeno Prostático Específico/sangue , Neoplasias da Próstata/terapia , Curva ROC , Processamento de Sinais Assistido por Computador
7.
Ultrasound Med Biol ; 29(11): 1593-605, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14654155

RESUMO

This report describes a monitoring technique for high-intensity focused ultrasound (US), or HIFU, lesions, including protein-denaturing lesions (PDLs) and those made for noninvasive cardiac therapy and tumor treatment in the eye, liver and other organs. Designed to sense the increased stiffness of a HIFU lesion, this technique uniquely utilizes the radiation force of the therapeutic US beam as an elastographic push to detect relative stiffness changes. Feasibility was demonstrated with computer simulations (treating acoustically induced displacements, concomitant heating, and US displacement-estimation algorithms) and pilot in vitro experimental studies, which agree qualitatively in differentiating HIFU lesions from normal tissue. Detectable motion can be induced by a single 5 ms push with temperatures well below those needed to form a lesion. Conversely, because the characteristic heat diffusion time is much longer than the characteristic relaxation time following a push, properly timed multiple therapy pulses will form lesions while providing precise control during therapy.


Assuntos
Simulação por Computador , Processamento de Imagem Assistida por Computador , Terapia por Ultrassom/métodos , Animais , Bovinos , Elasticidade , Estudos de Viabilidade , Temperatura Alta , Humanos , Fígado/diagnóstico por imagem , Movimento (Física) , Imagens de Fantasmas , Desnaturação Proteica , Transdutores , Ultrassonografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA