Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JAMA Netw Open ; 6(2): e230524, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36821110

RESUMO

Importance: An accurate and robust artificial intelligence (AI) algorithm for detecting cancer in digital breast tomosynthesis (DBT) could significantly improve detection accuracy and reduce health care costs worldwide. Objectives: To make training and evaluation data for the development of AI algorithms for DBT analysis available, to develop well-defined benchmarks, and to create publicly available code for existing methods. Design, Setting, and Participants: This diagnostic study is based on a multi-institutional international grand challenge in which research teams developed algorithms to detect lesions in DBT. A data set of 22 032 reconstructed DBT volumes was made available to research teams. Phase 1, in which teams were provided 700 scans from the training set, 120 from the validation set, and 180 from the test set, took place from December 2020 to January 2021, and phase 2, in which teams were given the full data set, took place from May to July 2021. Main Outcomes and Measures: The overall performance was evaluated by mean sensitivity for biopsied lesions using only DBT volumes with biopsied lesions; ties were broken by including all DBT volumes. Results: A total of 8 teams participated in the challenge. The team with the highest mean sensitivity for biopsied lesions was the NYU B-Team, with 0.957 (95% CI, 0.924-0.984), and the second-place team, ZeDuS, had a mean sensitivity of 0.926 (95% CI, 0.881-0.964). When the results were aggregated, the mean sensitivity for all submitted algorithms was 0.879; for only those who participated in phase 2, it was 0.926. Conclusions and Relevance: In this diagnostic study, an international competition produced algorithms with high sensitivity for using AI to detect lesions on DBT images. A standardized performance benchmark for the detection task using publicly available clinical imaging data was released, with detailed descriptions and analyses of submitted algorithms accompanied by a public release of their predictions and code for selected methods. These resources will serve as a foundation for future research on computer-assisted diagnosis methods for DBT, significantly lowering the barrier of entry for new researchers.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Humanos , Feminino , Benchmarking , Mamografia/métodos , Algoritmos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Neoplasias da Mama/diagnóstico por imagem
2.
Radiology ; 303(1): 69-77, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35040677

RESUMO

Background Digital breast tomosynthesis (DBT) has higher diagnostic accuracy than digital mammography, but interpretation time is substantially longer. Artificial intelligence (AI) could improve reading efficiency. Purpose To evaluate the use of AI to reduce workload by filtering out normal DBT screens. Materials and Methods The retrospective study included 13 306 DBT examinations from 9919 women performed between June 2013 and November 2018 from two health care networks. The cohort was split into training, validation, and test sets (3948, 1661, and 4310 women, respectively). A workflow was simulated in which the AI model classified cancer-free examinations that could be dismissed from the screening worklist and used the original radiologists' interpretations on the rest of the worklist examinations. The AI system was also evaluated with a reader study of five breast radiologists reading the DBT mammograms of 205 women. The area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and recall rate were evaluated in both studies. Statistics were computed across 10 000 bootstrap samples to assess 95% CIs, noninferiority, and superiority tests. Results The model was tested on 4310 screened women (mean age, 60 years ± 11 [standard deviation]; 5182 DBT examinations). Compared with the radiologists' performance (417 of 459 detected cancers [90.8%], 477 recalls in 5182 examinations [9.2%]), the use of AI to automatically filter out cases would result in 39.6% less workload, noninferior sensitivity (413 of 459 detected cancers; 90.0%; P = .002), and 25% lower recall rate (358 recalls in 5182 examinations; 6.9%; P = .002). In the reader study, AUC was higher in the standalone AI compared with the mean reader (0.84 vs 0.81; P = .002). Conclusion The artificial intelligence model was able to identify normal digital breast tomosynthesis screening examinations, which decreased the number of examinations that required radiologist interpretation in a simulated clinical workflow. Published under a CC BY 4.0 license. Online supplemental material is available for this article. See also the editorial by Philpotts in this issue.


Assuntos
Neoplasias da Mama , Inteligência Artificial , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Feminino , Humanos , Masculino , Mamografia/métodos , Pessoa de Meia-Idade , Estudos Retrospectivos , Carga de Trabalho
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA