Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Magn Reson Imaging ; 112: 38-46, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38604349

RESUMO

BACKGROUND: Measuring tissue oxygen concentration is crucial in understanding the pathophysiological process of hypoxia in head and neck cancer (HNC) and its significant role in cancer biology. This study aimed to determine the feasibility of T1 mapping using a variable flip angle (VFA) technique with stack of stars (SOS) trajectory sampling in HNC patients undergoing chemoradiotherapy (CRT). METHODS: To evaluate the ability of SOS acquisition to detect T1, a phantom study was conducted and compared to conventional Cartesian acquisition (CART). Additionally, four newly diagnosed patients were recruited and underwent two scans each at baseline and inter-treatment. The repeatability of SOS and CART acquisitions was assessed by comparing the T1 measurements of CSF from the baseline and intra-treatment MRI studies. The changes in ∆T1 of the tumors during air and oxygen inhalation between baseline and inter-treatment scans were also evaluated. RESULTS: Our study found that the 3D VFA SOS sequence was effective in reducing motion artifacts compared to the conventional VFA sequence with CART sampling and the same scan time, as demonstrated by the results from the phantom and patient studies. In terms of repeatability, no significant correlation was observed between the variability in ΔT1 measurements of CSF obtained from SOS T1 maps. The SOS ΔT1 measurements showed higher consistency, as evidenced by the ICC values ranging from 0.52 to 0.92. The ∆T1 measurements on the primary tumors increased after the first CRT (p<0.05) for all patients who showed a positive treatment response, except for one patient (0.05

2.
J Interv Card Electrophysiol ; 67(2): 263-271, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36973597

RESUMO

BACKGROUND: The low-voltage area detected by electroanatomic mapping (EAM) is a surrogate marker of left atrial fibrosis. However, the correlation between the EAM and late gadolinium enhancement magnetic resonance imaging (LGE-MRI) has been inconsistent among studies. This study aimed to investigate how LA size affects the correlation between EAM and LGE-MRI. METHODS: High-density EAMs of the LA during sinus rhythm were collected in 22 patients undergoing AF ablation. The EAMs were co-registered with pre-ablation LGE-MRI models. Voltages in the areas with and without LGE were recorded. Left atrial volume index (LAVI) was calculated from MRI, and LAVI > 62 ml/m2 was defined as significant LA enlargement (LAE). RESULTS: Atrial bipolar voltage negatively correlates with the left atrial volume index. The median voltages in areas without LGE were 1.1 mV vs 2.0 mV in patients with vs without significant LAE (p = 0.002). In areas of LGE, median voltages were 0.4 mV vs 0.8 mV in patients with vs without significant LAE (p = 0.02). A voltage threshold of 1.7 mV predicted atrial LGE in patients with normal or mildly enlarged LA (sensitivity and specificity of 74% and 59%, respectively). In contrast, areas of voltage less than 0.75 mV correlated with LGE in patients with significant LA enlargement (sensitivity 68% and specificity 66%). CONCLUSIONS: LAVI affects left atrial bipolar voltage, and the correlation between low-voltage areas and LGE-MRI. Distinct voltage thresholds according to the LAVI value might be considered to identify atrial scar by EAM.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Meios de Contraste , Gadolínio , Átrios do Coração/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Fibrose , Ablação por Cateter/métodos
3.
Magn Reson Imaging ; 101: 40-46, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37030177

RESUMO

PURPOSE: To evaluate the dependence of the arterial input function (AIF) on the imaging z-axis and its effect on 3D DCE MRI pharmacokinetic parameters as mediated by the SPGR signal equation and Extended Tofts-Kermode model. THEORY: For SPGR-based 3D DCE MRI acquisition of the head and neck, inflow effects within vessels violate the assumptions underlying the SPGR signal model. Errors in the SPGR-based AIF estimate propagate through the Extended Tofts-Kermode model to affect the output pharmacokinetic parameters. MATERIALS AND METHODS: 3D DCE-MRI data were acquired for six newly diagnosed HNC patients in a prospective single arm cohort study. AIF were selected within the carotid arteries at each z-axis location. A region of interest (ROI) was placed in normal paravertebral muscle and the Extended Tofts-Kermode model solved for each pixel within the ROI for each AIF. Results were compared to those obtained with a published population average AIF. RESULTS: Due to inflow effect, the AIF showed extreme variation in their temporal shapes. Ktrans was most sensitive to the initial bolus concentration and showed more variation over the muscle ROI with AIF taken from the upstream portion of the carotid. kep was less sensitive to the peak bolus concentration and showed less variation for AIF taken from the upstream portion of the carotid. CONCLUSION: Inflow effects may introduce an unknown bias to SPGR-based 3D DCE pharmacokinetic parameters. Variation in the computed parameters depends on the selected AIF location. In the context of high flow, measurements may be limited to relative rather than absolute quantitative parameters.


Assuntos
Meios de Contraste , Neoplasias de Cabeça e Pescoço , Humanos , Meios de Contraste/farmacocinética , Estudos de Coortes , Estudos Prospectivos , Imageamento por Ressonância Magnética/métodos , Artérias Carótidas , Algoritmos , Reprodutibilidade dos Testes
4.
J Am Heart Assoc ; 10(7): e018924, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33759540

RESUMO

Background Esophageal thermal injury (ETI) is a byproduct of atrial fibrillation (AF) ablation using thermal sources. The most severe form of ETI is represented by atrioesophageal fistula, which has a high mortality rate. Late gadolinium enhancement (LGE) magnetic resonance imaging (MRI) allows identification of ETI. Hence, we sought to evaluate the utility of LGE-MRI as a method to identify ETI across the entire spectrum of severity. Methods and Results All AF radiofrequency ablations performed at the University of Utah between January 2009 and December 2017 were reviewed. Patients with LGE-MRI within 24 hours following AF ablation as well as patients who had esophagogastroduodenoscopy in addition to LGE-MRI were identified. An additional patient with atrioesophageal fistula who had AF ablation at a different institution and had MRI and esophagogastroduodenoscopy at the University of Utah was identified. A total of 1269 AF radiofrequency ablations were identified. ETI severity was classified on the basis of esophageal LGE pattern (none, 60.9%; mild, 27.5%; moderate, 9.9%; severe, 1.7%). ETI resolved in most patients who underwent repeat LGE-MRI at 3 months. All patients with esophagogastroduodenoscopy-confirmed ETI had moderate-to-severe LGE 24 hours after ablation MRI. Moderate-to-severe LGE had 100% sensitivity and 58.1% specificity in detecting ETI, and a negative predictive value of 100%. Atrioesophageal fistula was visualized by both computed tomography and LGE-MRI in one patient. Conclusions LGE-MRI is useful in detecting and characterizing ETI across the entire severity spectrum. LGE-MRI exhibits an extremely high sensitivity and negative predictive value in screening for ETI after AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Queimaduras/diagnóstico , Ablação por Cateter/efeitos adversos , Esôfago/lesões , Gadolínio/farmacologia , Imageamento por Ressonância Magnética/métodos , Idoso , Queimaduras/etiologia , Meios de Contraste/farmacologia , Esofagoscopia/métodos , Esôfago/diagnóstico por imagem , Feminino , Seguimentos , Humanos , Masculino , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo
5.
Circ Arrhythm Electrophysiol ; 12(8): e007174, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31422685

RESUMO

BACKGROUND: Macroreentrant atrial tachycardia (AT) accounts for 40% to 60% of recurrent atrial arrhythmias after atrial fibrillation (AF) ablation. To describe late gadolinium enhancement magnetic resonance imaging (LGE-MRI)-detected scar-based dechanneling as new ablation strategy to treat ATs after AF ablation. METHODS: Data from 102 patients who underwent initial AF ablation and repeat ablation for recurrent atrial arrhythmia within 1-year follow-up were analyzed. All patients underwent LGE-MRI before initial and repeat ablation. Depending on the recurrent rhythm, patients with AF and AT recurrence were assigned to group 1 or 2, respectively. Group 1 underwent fibrosis homogenization as second procedure. Group 2 underwent LGE-MRI-detected scar-based dechanneling. Both groups underwent reisolation of pulmonary veins if necessary. RESULTS: Forty-six patients (45%) presented with AF, and 56 patients (55%) presented with AT recurrence during follow-up after initial ablation. In the first 25 patients from group 2, the AT was electroanatomically mapped, and a critical isthmus was defined. It was found that those isthmi were located in the regions with nontransmural scarring detected by LGE-MRI. In the last 31 patients from group 2, an empirical LGE-MRI-based dechanneling was performed solely based on the LGE-MRI results. During 1-year follow-up after second ablation, 67% patients in group 1 and 64% patients in group 2 were free from recurrence (log-rank, P=1.000). In group 2, 64% in the electroanatomically guided and 65% in the LGE-MRI dechanneling group were free from recurrence (log-rank, P=0.900). CONCLUSIONS: Anatomic targeting of LGE-MRI-detected gaps and superficial atrial scar is feasible and effective to treat recurrent arrhythmias post-AF ablation. Homogenization of existing scar is the appropriate treatment for recurrent AF, whereas dechanneling of existing isthmi seems the right approach for patients recurring with AT.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Meglumina/análogos & derivados , Compostos Organometálicos/farmacologia , Cirurgia Assistida por Computador/métodos , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Remodelamento Atrial , Meios de Contraste/farmacologia , Feminino , Seguimentos , Gadolínio , Átrios do Coração/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Imageamento Tridimensional , Masculino , Meglumina/farmacologia , Período Pós-Operatório , Recidiva , Estudos Retrospectivos , Fatores de Tempo
6.
Europace ; 21(1): 154-162, 2019 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-29878090

RESUMO

AIMS: The goals of this study were to develop a method that combines cryoablation with real-time magnetic resonance imaging (MRI) guidance for pulmonary vein isolation (PVI) and to further quantify the lesion formation by imaging both acute and chronic cryolesions. METHODS AND RESULTS: Investigational MRI-compatible cryoablation devices were created by modifying cryoballoons and cryocatheters. These devices were used in canines (n = 8) and a complete series of lesions (PVI: n = 5, superior vena cava: n = 4, focal: n = 13) were made under real-time MRI guidance. Late gadolinium enhancement (LGE) magnetic resonance imaging was acquired at acute and chronic time points. Late gadolinium enhancement magnetic resonance imagings show a significant amount of acute tissue injury immediately following cryoablation which subsides over time. In the pulmonary veins, scar covered 100% of the perimeter of the ostium of the veins acutely, which subsided to 95.6 ± 4.3% after 3 months. Focal point lesions showed significantly larger acute enhancement volumes compared to the volumes estimated from gross pathology measurements (0.4392 ± 0.28 cm3 vs. 0.1657 ± 0.08 cm3, P = 0.0043). Additionally, our results with focal point ablations indicate that freeze-zone formation reached a maximum area after 120 s. CONCLUSION: This study reports on the development of an MRI-based cryoablation system and shows that with acute cryolesions there is a large area of reversible injury. Real-time MRI provides the ability to visualize the freeze-zone formation during the freeze cycle and for focal lesions reaches a maximum after 120 s suggesting that for maximizing lesion size 120 s might be the lower limit for dosing duration.


Assuntos
Criocirurgia , Imagem por Ressonância Magnética Intervencionista , Veias Pulmonares/cirurgia , Veia Cava Superior/cirurgia , Animais , Criocirurgia/efeitos adversos , Cães , Imagem por Ressonância Magnética Intervencionista/efeitos adversos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Fatores de Risco , Fatores de Tempo , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/patologia
7.
J Cardiovasc Electrophysiol ; 29(3): 385-392, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29345381

RESUMO

INTRODUCTION: Adequate catheter/atrial tissue contact is critical for lesion formation during radiofrequency (RF) ablation of atrial fibrillation (AF). Late gadolinium enhancement magnetic resonance imaging (LGE-MRI) is a unique tool for the evaluation of lesion formation and detection of acute esophageal injury. METHODS: LGE-MRIs were obtained prior, within 24 hours of, and at 115 ± 62 days after first AF ablation in 36 patients. The Visitag module of CARTO3 was used to collect contact force (CF) and duration from a CF sensing ablation catheter for each registered ablation point. The minimum CF resulting in permanent lesions was determined. Esophageal enhancement detected by acute LGE-MRI was classified as mild, moderate, and severe. The CF resulting in esophageal enhancement was determined. RESULTS: A total of 4,642 registered ablation tags at 50 W power were analyzed. The mean RF duration (5.9 ± 3.7 vs. 5.6 ± 3.2 seconds, P < 0.05), CF (11.5 ± 5.6 vs. 10.9 ± 5.4 g, P < 0.001), and force time integral (FTI) (67.3 ± 54.5 vs. 62.2 ± 52.7 gs, P < 0.01) were significantly higher between ablation tags with and without associated LGE-MRI detected scar. The mean CF (15.7 ± 6.1 vs. 12.6 ± 5.9 g, P < 0.05, n  =  17 patients) in areas of esophageal enhancement was greater than areas without. CONCLUSION: Left atrial short duration ablation lesions with a CF greater than 12 g are more likely to be associated with permanent lesion formation. Ablating on top of the esophagus, CF less than 15 g would help minimize esophageal wall injury.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Esôfago/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Ferimentos e Lesões/prevenção & controle , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Cicatriz/etiologia , Esôfago/lesões , Feminino , Fibrose , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/fisiopatologia , Humanos , Masculino , Meglumina/administração & dosagem , Pessoa de Meia-Idade , Duração da Cirurgia , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Ferimentos e Lesões/diagnóstico por imagem , Ferimentos e Lesões/etiologia
8.
Artigo em Inglês | MEDLINE | ID: mdl-29079664

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) has been used to acutely visualize radiofrequency ablation lesions, but its accuracy in predicting chronic lesion size is unknown. The main goal of this study was to characterize different areas of enhancement in late gadolinium enhancement MRI done immediately after ablation to predict acute edema and chronic lesion size. METHODS AND RESULTS: In a canine model (n=10), ventricular radiofrequency lesions were created using ThermoCool SmartTouch (Biosense Webster) catheter. All animals underwent MRI (late gadolinium enhancement and T2-weighted edema imaging) immediately after ablation and after 1, 2, 4, and 8 weeks. Edema, microvascular obstruction, and enhanced volumes were identified in MRI and normalized to chronic histological volume. Immediately after contrast administration, the microvascular obstruction region was 3.2±1.1 times larger than the chronic lesion volume in acute MRI. Even 60 minutes after contrast administration, edema was 8.7±3.31 times and the enhanced area 6.14±2.74 times the chronic lesion volume. Exponential fit to the microvascular obstruction volume was found to be the best predictor of chronic lesion volume at 26.14 minutes (95% prediction interval, 24.35-28.11 minutes) after contrast injection. The edema volume in late gadolinium enhancement correlated well with edema volume in T2-weighted MRI with an R2 of 0.99. CONCLUSION: Microvascular obstruction region on acute late gadolinium enhancement images acquired 26.1 minutes after contrast administration can accurately predict the chronic lesion volume. We also show that T1-weighted MRI images acquired immediately after contrast injection accurately shows edema resulting from radiofrequency ablation.


Assuntos
Ablação por Cateter/efeitos adversos , Cicatriz/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Edema Cardíaco/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos/administração & dosagem , Animais , Biópsia , Cicatriz/etiologia , Cicatriz/patologia , Circulação Coronária , Cães , Edema Cardíaco/etiologia , Edema Cardíaco/patologia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/patologia , Meglumina/administração & dosagem , Microcirculação , Modelos Animais , Valor Preditivo dos Testes , Fatores de Tempo
9.
Am J Cardiol ; 118(7): 991-7, 2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27553101

RESUMO

Left ventricular (LV) scar identified by late gadolinium enhanced (LGE) cardiac magnetic resonance (CMR) is associated with adverse outcomes in coronary artery disease and cardiomyopathies. We sought to determine the prognostic significance of LV-LGE in atrial fibrillation (AF). We studied 778 consecutive patients referred for radiofrequency ablation of AF who underwent CMR. Patients with coronary artery disease, previous myocardial infarction, or hypertrophic or dilated cardiomyopathy were excluded. The end points of interest were major adverse cardiac and cerebrovascular events (MACCE), defined as a composite of cardiovascular death, myocardial infarction, and ischemic stroke/transient ischemic attack. Of the 754 patients who met the inclusion criteria, 60% were men with an average age of 64 years. Most (87%) had a normal LV ejection fraction of ≥55%. LV-LGE was found in 46 patients (6%). There were 32 MACCE over the mean follow-up period of 55 months. The MACCE rate was higher for patients with LV-LGE (13.0% vs 3.7%; p = 0.002). In multivariate analysis, CHA2DS2-VASc score (hazard ratio [HR] 1.36, 95% CI 1.05 to 1.76), the presence of LV-LGE (HR 3.21, 95% CI 1.31 to 7.88), and the LV-LGE extent (HR 1.43, 95% CI 1.15 to 1.78) were independent predictors of MACCE. In addition, the presence of LV-LGE was an independent predictor for ischemic stroke/transient ischemic attack (HR 3.61, 95% CI 1.18 to 11.01) after adjusting for CHA2DS2-VASc score. In conclusion, the presence and extent of LV scar identified by LGE-CMR were independent predictors of MACCE in patients with AF.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Cicatriz/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Idoso , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doenças Cardiovasculares/mortalidade , Ablação por Cateter , Cicatriz/epidemiologia , Meios de Contraste , Diabetes Mellitus/epidemiologia , Dislipidemias/epidemiologia , Feminino , Seguimentos , Gadolínio , Insuficiência Cardíaca/epidemiologia , Humanos , Imageamento Tridimensional , Ataque Isquêmico Transitório/epidemiologia , Modelos Logísticos , Imageamento por Ressonância Magnética , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/epidemiologia , Razão de Chances , Prognóstico , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Fumar/epidemiologia , Acidente Vascular Cerebral/epidemiologia , Fatores de Tempo
10.
J Cardiovasc Electrophysiol ; 27(5): 602-8, 2016 05.
Artigo em Inglês | MEDLINE | ID: mdl-26856381

RESUMO

INTRODUCTION: MRI-based ablation provides an attractive capability of seeing ablation-related tissue changes in real time. Here we describe a real-time MRI-based cardiac cryo-ablation system. METHODS: Studies were performed in canine model (n = 4) using MR-compatible cryo-ablation devices built for animal use: focal cryo-catheter with 8 mm tip and 28 mm diameter cryo-balloon. The main steps of MRI-guided cardiac cryo-ablation procedure (real-time navigation, confirmation of tip-tissue contact, confirmation of vessel occlusion, real-time monitoring of a freeze zone formation, and intra-procedural assessment of lesions) were validated in a 3 Tesla clinical MRI scanner. RESULTS: The MRI compatible cryo-devices were advanced to the right atrium (RA) and right ventricle (RV) and their position was confirmed by real-time MRI. Specifically, contact between catheter tip and myocardium and occlusion of superior vena cava (SVC) by the balloon was visually validated. Focal cryo-lesions were created in the RV septum. Circumferential ablation of SVC-RA junction with no gaps was achieved using the cryo-balloon. Real-time visualization of freeze zone formation was achieved in all studies when lesions were successfully created. The ablations and presence of collateral damage were confirmed by T1-weighted and late gadolinium enhancement MRI and gross pathological examination. CONCLUSION: This study confirms the feasibility of a MRI-based cryo-ablation system in performing cardiac ablation procedures. The system allows real-time catheter navigation, confirmation of catheter tip-tissue contact, validation of vessel occlusion by cryo-balloon, real-time monitoring of a freeze zone formation, and intra-procedural assessment of ablations including collateral damage.


Assuntos
Criocirurgia/métodos , Átrios do Coração/cirurgia , Imagem por Ressonância Magnética Intervencionista , Veia Cava Superior/cirurgia , Animais , Cateteres Cardíacos , Criocirurgia/instrumentação , Cães , Desenho de Equipamento , Estudos de Viabilidade , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/patologia , Modelos Animais , Miocárdio/patologia , Valor Preditivo dos Testes , Fatores de Tempo , Veia Cava Superior/diagnóstico por imagem , Veia Cava Superior/patologia
11.
Europace ; 17(3): 483-8, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25336666

RESUMO

AIM: Late gadolinium enhanced (LGE) magnetic resonance imaging (MRI) is a useful tool for facilitating ventricular tachycardia (VT) ablation. Unfortunately, most VT ablation candidates often have prophylactic implantable cardioverter-defibrillator (ICD) and do not undergo cardiac MRI largely due to image artefacts generated by ICD. A prior study has reported success of 'wideband' LGE MRI for imaging myocardial scar without image artefacts induced by ICD at 1.5T. The purpose of this study was to widen the availability of wideband LGE MRI to 3T, since it has the potential to achieve higher spatial resolution than 1.5T. METHODS AND RESULTS: We compared the performance of standard and wideband LGE MRI pulse sequences in phantoms and canines with myocardial lesions created by radiofrequency ablation. Standard LGE MRI produced image artefacts induced by ICD and 49% accuracy in detecting 97 myocardial scars examined in this study, whereas wideband LGE MRI produced artefact-free images and 94% accuracy in detecting scars. The mean image quality score (1 = nondiagnostic, 2 = poor, 3 = adequate, 4 = good, 5 = excellent) was significantly (P < 0.001) higher for wideband (3.7 ± 0.8) than for standard LGE MRI (2.1 ± 0.7). The mean artefact level score (1 = minimal, 2 = mild, 3 = moderate, 4 = severe, 5 = nondiagnostic) was significantly (P < 0.001) lower for wideband (2.1 ± 0.8) than for standard LGE MRI (4.0 ± 0.6). Wideband LGE MRI agreed better with gross pathology than standard LGE MRI. CONCLUSION: This study demonstrates the feasibility of wideband LGE MRI for suppression of image artefacts induced by ICD at 3T.


Assuntos
Artefatos , Cicatriz/diagnóstico , Desfibriladores Implantáveis , Imageamento por Ressonância Magnética/métodos , Miocárdio/patologia , Animais , Ablação por Cateter/métodos , Cicatriz/patologia , Meios de Contraste , Cães , Estudos de Viabilidade , Gadolínio , Imagens de Fantasmas , Cirurgia Assistida por Computador/métodos , Taquicardia Ventricular/cirurgia
12.
J Cardiovasc Electrophysiol ; 25(5): 457-463, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24383404

RESUMO

BACKGROUND: Three-dimensional electroanatomic mapping (EAM) is routinely used to mark ablated areas during radiofrequency ablation. We hypothesized that, in atrial fibrillation (AF) ablation, EAM overestimates scar formation in the left atrium (LA) when compared to the scar seen on late-gadolinium enhancement magnetic resonance imaging (LGE-MRI). METHODS AND RESULTS: Of the 235 patients who underwent initial ablation for AF at our institution between August 2011 and December 2012, we retrospectively identified 70 patients who had preprocedural magnetic resonance angiography merged with LA anatomy in EAM software and had a 3-month postablation LGE-MRI for assessment of scar. Ablated area was marked intraprocedurally using EAM software and quantified retrospectively. Scarred area was quantified in 3-month postablation LGE-MRI. The mean ablated area in EAM was 30.5 ± 7.5% of the LA endocardial surface and the mean scarred area in LGE-MRI was 13.9 ± 5.9% (P < 0.001). This significant difference in the ablated area marked in the EAM and scar area in the LGE-MRI was present for each of the 3 independent operators. Complete pulmonary vein (PV) encirclement representing electrical isolation was observed in 87.8% of the PVs in EAM as compared to only 37.4% in LGE-MRI (P < 0.001). CONCLUSIONS: In AF ablation, EAM significantly overestimates the resultant scar as assessed with a follow-up LGE-MRI.


Assuntos
Fibrilação Atrial/terapia , Ablação por Cateter , Cicatriz/diagnóstico , Técnicas Eletrofisiológicas Cardíacas , Átrios do Coração/cirurgia , Angiografia por Ressonância Magnética , Veias Pulmonares/cirurgia , Cirurgia Assistida por Computador , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cicatriz/patologia , Cicatriz/fisiopatologia , Feminino , Átrios do Coração/patologia , Átrios do Coração/fisiopatologia , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Veias Pulmonares/patologia , Veias Pulmonares/fisiopatologia , Reprodutibilidade dos Testes , Estudos Retrospectivos , Software , Resultado do Tratamento , Utah
13.
Magn Reson Med ; 70(4): 994-1004, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23165722

RESUMO

The visualization of lesion formation in real time is one potential benefit of carrying out radiofrequency ablation under magnetic resonance (MR) guidance in the treatment of atrial fibrillation. MR thermometry has the potential to detect such lesions. However, performing MR thermometry during cardiac radiofrequency ablation requires high temporal and spatial resolution and a high signal-to-noise ratio. In this study, a local MR coil (2-cm diameter) was developed to investigate the feasibility of performing limited field of view MR thermometry with high accuracy and speed. The local MR coil allowed high-resolution (1 × 1 × 3 mm(3)) image acquisitions in 76.3 ms with a field of view 64 × 32 mm(2) during an open-chest animal experiment. This represents a 4-fold image acquisition acceleration and an 18-fold field of view reduction compared to that achieved using external MR coils. The signal sensitivity achieved using the local coil was over 20 times greater than that achievable using external coils with the same scan parameters. The local coil configuration provided fewer artifacts and sharper and more stable images. These results demonstrate that MR thermometry can be performed in the heart wall and that lesion formation can be observed during radiofrequency ablation procedures in a canine model.


Assuntos
Ablação por Cateter/instrumentação , Ventrículos do Coração/cirurgia , Imageamento por Ressonância Magnética/instrumentação , Magnetismo/instrumentação , Cirurgia Assistida por Computador/métodos , Termografia/instrumentação , Transdutores , Animais , Cães , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Interpretação de Imagem Assistida por Computador/instrumentação , Ondas de Rádio , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Control Release ; 160(3): 459-67, 2012 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-22465391

RESUMO

Synthetic arteriovenous (AV) hemodialysis grafts are plagued by hyperplasia resulting in occlusion and graft failure yet there are no clinically available preventative treatments. Here the delivery and degradation of a sirolimus-laden polymer gel were monitored in vivo by magnetic resonance imaging (MRI) and its efficacy for inhibiting hyperplasia was evaluated in a porcine model of AV graft stenosis. Synthetic grafts were placed between the carotid artery and ipsilateral jugular vein of swine. A biodegradable polymer gel loaded with sirolimus (2.5mg/mL) was immediately applied perivascularly to the venous anastomosis, and reapplied by ultrasound-guided injections at one, two and three weeks. Control grafts received neither sirolimus nor polymer. The lumen cross-sectional area at the graft-vein anastomosis was assessed in vivo by non-invasive MRI. The explanted tissues also underwent histological analysis. A specifically developed MRI pulse sequence provided a high contrast-to-noise ratio (CNR) between the polymer and surrounding tissue that allowed confirmation of gel location after injection. Polymer signal decreased up to 80% at three to four weeks after injection, slightly faster than its degradation kinetics in vitro. The MR image of the polymer was confirmed by visual assessment at necropsy. On histological assessment, the mean hyperplasia surface area of the treated graft was 52% lower than that of the control grafts (0.43mm(2) vs. 0.89mm(2); p<0.003), while the minimum cross-sectional lumen area, as measured on MRI, was doubled (5.3mm(2) vs 2.5mm(2); p<0.05). In conclusion, customized MRI allowed non-invasive monitoring of the location and degradation of drug delivery polymer gels in vivo. Perivascular application of sirolimus-laden polymer yielded a significant decrease in hyperplasia development and an increase in lumen area at the venous anastomosis of AV grafts.


Assuntos
Antibióticos Antineoplásicos/administração & dosagem , Oclusão de Enxerto Vascular/tratamento farmacológico , Hiperplasia/tratamento farmacológico , Polietilenoglicóis/administração & dosagem , Poliglactina 910/administração & dosagem , Sirolimo/administração & dosagem , Animais , Antibióticos Antineoplásicos/sangue , Antibióticos Antineoplásicos/farmacocinética , Portadores de Fármacos/administração & dosagem , Géis , Oclusão de Enxerto Vascular/metabolismo , Hiperplasia/metabolismo , Polietilenoglicóis/farmacocinética , Poliglactina 910/farmacocinética , Diálise Renal , Sirolimo/sangue , Sirolimo/farmacocinética , Sus scrofa
15.
Circ Arrhythm Electrophysiol ; 2(6): 620-5, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20009076

RESUMO

BACKGROUND: Esophageal wall thermal injury after atrial fibrillation ablation is a potentially serious complication. However, no noninvasive modality has been used to describe and screen patients to examine whether esophageal wall injury has occurred. We describe a noninvasive method of using delayed-enhancement MRI to detect esophageal wall injury and subsequent recovery after atrial fibrillation ablation. METHODS AND RESULTS: We analyzed the delayed-enhancement MRI scans of 41 patients before ablation and at 24 hours and 3 months after ablation to determine whether there was evidence of contrast enhancement in the esophagus after atrial fibrillation ablation. In patients with contrast enhancement, 3D segmentation of the esophagus was performed using a novel image processing method. Upper gastrointestinal endoscopy was then performed. Repeat delayed-enhancement MRI and upper gastrointestinal endoscopy was performed 1 week later to track changes in lesions. The wall thickness of the anterior and posterior wall of the esophagus was measured at 3 time points: before ablation, 24 hours after ablation, and 3 months after ablation. Evaluation of preablation MRI scans demonstrated no cases of esophageal enhancement. At 24 hours, 5 patients showed contrast enhancement. Three of these patients underwent upper gastrointestinal endoscopy, which demonstrated esophageal lesions. Repeat upper gastrointestinal endoscopy and MRI 1 week later demonstrated resolution of the lesions. All 5 patients had confirmed resolution of enhancement at 3 months. All patients with esophageal tissue enhancement demonstrated left atrial wall enhancement directly adjacent to the regions of anterior wall esophageal enhancement. CONCLUSIONS: Our preliminary results indicate delayed-enhancement MRI can assess the extent and follow progression of esophageal wall injury after catheter ablation of atrial fibrillation. It appears that acute esophageal injury recovers within 1 week of the procedure.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Meios de Contraste , Esôfago/patologia , Imagem Cinética por Ressonância Magnética , Meglumina/análogos & derivados , Compostos Organometálicos , Idoso , Fibrilação Atrial/patologia , Esofagoscopia , Esôfago/lesões , Estudos de Viabilidade , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA