Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Tech Mess ; 90(12): 761-785, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38046181

RESUMO

This review provides an overview on bio- and chemosensors based on a thermal transducer platform that monitors the thermal interface resistance R th between a solid chip and the supernatant liquid. The R th parameter responds in a surprisingly strong way to molecular-scale changes at the solid-liquid interface, which can be measured thermometrically, using for instance thermocouples in combination with a controllable heat source. In 2012, the effect was first observed during on-chip denaturation experiments on complementary and mismatched DNA duplexes that differ in their melting temperature. Since then, the concept is addressed as heat-transfer method, in short HTM, and numerous applications of the basic sensing principle were identified. Functionalizing the chip with bioreceptors such as molecularly imprinted polymers makes it possible to detect neurotransmitters, inflammation markers, viruses, and environmental pollutants. In combination with aptamer-type receptors, it is also possible to detect proteins at low concentrations. Changing the receptors to surface-imprinted polymers has opened up new possibilities for quantitative bacterial detection and identification in complex matrices. In receptor-free variants, HTM was successfully used to characterize lipid vesicles and eukaryotic cells (yeast strains, cancer cell lines), the latter showing spontaneous detachment under influence of the temperature gradient inherent to HTM. We will also address modifications to the original HTM technique such as M-HTM, inverted HTM, thermal wave transport analysis TWTA, and the hot-wire principle. The article concludes with an assessment of the possibilities and current limitations of the method, together with a technological forecast.

2.
Sensors (Basel) ; 24(1)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38202993

RESUMO

Per- and polyfluoroalkyl substances (PFAS) are a class of materials that have been widely used in the industrial production of a wide range of products. After decades of bioaccumulation in the environment, research has demonstrated that these compounds are toxic and potentially carcinogenic. Therefore, it is essential to map the extent of the problem to be able to remediate it properly in the next few decades. Current state-of-the-art detection platforms, however, are lab based and therefore too expensive and time-consuming for routine screening. Traditional biosensor tests based on, e.g., lateral flow assays may struggle with the low regulatory levels of PFAS (ng/mL), the complexity of environmental matrices and the presence of coexisting chemicals. Therefore, a lot of research effort has been directed towards the development of biomimetic receptors and their implementation into handheld, low-cost sensors. Numerous research groups have developed PFAS sensors based on molecularly imprinted polymers (MIPs), metal-organic frameworks (MOFs) or aptamers. In order to transform these research efforts into tangible devices and implement them into environmental applications, it is necessary to provide an overview of these research efforts. This review aims to provide this overview and critically compare several technologies to each other to provide a recommendation for the direction of future research efforts focused on the development of the next generation of biomimetic PFAS sensors.


Assuntos
Biomimética , Fluorocarbonos , Humanos , Carcinogênese , Carcinógenos , Indústrias
3.
Adv Sci (Weinh) ; 9(24): e2200459, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35780480

RESUMO

Despite the importance of cell characterization and identification for diagnostic and therapeutic applications, developing fast and label-free methods without (bio)-chemical markers or surface-engineered receptors remains challenging. Here, we exploit the natural cellular response to mild thermal stimuli and propose a label- and receptor-free method for fast and facile cell characterization. Cell suspensions in a dedicated sensor are exposed to a temperature gradient, which stimulates synchronized and spontaneous cell-detachment with sharply defined time-patterns, a phenomenon unknown from literature. These patterns depend on metabolic activity (controlled through temperature, nutrients, and drugs) and provide a library of cell-type-specific indicators, allowing to distinguish several yeast strains as well as cancer cells. Under specific conditions, synchronized glycolytic-type oscillations are observed during detachment of mammalian and yeast-cell ensembles, providing additional cell-specific signatures. These findings suggest potential applications for cell viability analysis and for assessing the collective response of cancer cells to drugs.


Assuntos
Células Eucarióticas , Saccharomyces cerevisiae , Animais , Glicólise , Mamíferos , Saccharomyces cerevisiae/metabolismo
4.
Eur J Pharm Biopharm ; 146: 133-142, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31698041

RESUMO

Doxorubicin is an anti-cancer drug that is important for breast cancer therapy. In this study, the effects of the membrane potential of breast cancer cells (-30 mV) and normal breast epithelial cells (-60 mV) on doxorubicin (DOX) permeability was studied. To achieve this goal, black lipid membranes (BLMs) as a model cell membrane were formed with DPhPC phospholipids in a single aperture of a Teflon sheet by the Montal and Mueller method. The presence of the BLM was characterized by capacitive measurements. The measured specific capacitance of 0.6 µF/cm2 after applying the Montal and Mueller method, confirming the presence of a BLM in the aperture. In addition, the very low current leakage of the BLM (9-24 pA) and ClyA-protein channel insertion in the BLM indicate the compactness, high quality, and thickness of 3-5 nm of the BLM. Afterwards, the permeability of doxorubicin through the BLM was studied at defined cell conditions (37 °C and pH 7.4), as well as cancerous and healthy epithelial-cell membrane potentials (-30 mV and -60 mV, respectively). The results show a slow DOX penetration within the first few hours, which increases rapidly with time. The initial slow penetration can be attributed to an electrostatic interaction between doxorubicin and DPhPC molecules in the model cell membrane. Furthermore, a MTT assay on MCF-10A and MCF-7 under different concentrations of doxorubicin confirmed that the cancerous MCF-7 cell line is more resistant to doxorubicin in comparison with the non-cancerous MCF-10A. Such studies highlight important strategies for designing and tuning the interaction efficacy of novel pharmaceuticals at molecular level.


Assuntos
Antineoplásicos/farmacocinética , Neoplasias da Mama/tratamento farmacológico , Permeabilidade da Membrana Celular/fisiologia , Doxorrubicina/farmacocinética , Potenciais da Membrana , Antineoplásicos/administração & dosagem , Apoptose/efeitos dos fármacos , Neoplasias da Mama/patologia , Relação Dose-Resposta a Droga , Doxorrubicina/administração & dosagem , Resistencia a Medicamentos Antineoplásicos , Células Epiteliais/citologia , Células Epiteliais/metabolismo , Feminino , Humanos , Bicamadas Lipídicas/metabolismo , Células MCF-7 , Fosfolipídeos/metabolismo
5.
Langmuir ; 31(6): 2043-50, 2015 Feb 17.
Artigo em Inglês | MEDLINE | ID: mdl-25654744

RESUMO

Previous work has indicated that surface imprinted polymers (SIPs) allow for highly specific cell detection through macromolecular cell imprints. The combination of SIPs with a heat-transfer-based read-out technique has led to the development of a selective, label-free, low-cost, and user-friendly cell detection assay. In this study, the breast cancer cell line ZR-75-1 is used to assess the potential of the platform for monitoring the quality of a cell culture in time. For this purpose, we show that the proposed methodology is able to discriminate between the original cell line (adherent growth, ZR-75-1a) and a descendant cell line (suspension growth, ZR-75-1s). Moreover, ZR-75-1a cells were cultured for a prolonged period of time and analyzed using the heat-transfer method (HTM) at regular time intervals. The results of these experiments demonstrate that the thermal resistance (Rth) signal decays after a certain number of cell culture passages. This can likely be attributed to a compromised quality of the cell culture due to cross-contamination with the ZR-75-1s cell line, a finding that was confirmed by classical STR DNA profiling. The cells do not express the same functional groups on their membrane, resulting in a weaker bond between cell and imprint, enabling cell removal by mechanical friction, provided by flushing the measuring chamber with buffer solution. These findings were further confirmed by HTM and illustrate that the biomimetic sensor platform can be used as an assay for monitoring the quality of cell cultures in time.


Assuntos
Biomimética/métodos , Temperatura Alta , Impressão Molecular , Sondas Moleculares/síntese química , Polímeros/síntese química , Técnicas de Cultura de Células , Linhagem Celular Tumoral , Humanos , Repetições de Microssatélites , Sondas Moleculares/metabolismo , Polímeros/metabolismo , Controle de Qualidade , Propriedades de Superfície
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA