Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Bone Rep ; 18: 101659, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36817167

RESUMO

While the positive association between automated intact fibroblast growth factor (FGF) 23 measurement kit (Determinar CL FGF23 [CL]) and the former assay (Kainos [KI]), and clinical utility of CL was well established, the clinical performance of Medfrontier FGF23 (MED), which was the manual intact FGF23 measurement kit with same antibody set as CL, has not yet been validated. Therefore, this study aims to compare MED FGF23 levels to KI FGF23 levels. A total of 380 samples were collected from healthy individuals, and 200 samples were collected from 20 patients with chronic hypophosphatemia. The intact FGF23 level of each sample was measured by KI and MED. Among the healthy individuals, the reference range of MED FGF23 levels was 18.6-59.8 pg/mL when calculated as the average ± 2 standard deviations. When compared with KI FGF23 levels, MED FGF23 levels were lower than KI levels both among samples from healthy individuals (KI FGF23, 40.9 [interquartile (IQR), 31.1-50.6]; MED FGF23, 38.0 [IQR, 31.5-45.7]; p value = 0.02) and among samples from patients with chronic hypophosphatemia (KI FGF23, 172.5 [IQR, 115.8-290.7]; MED FGF23, 130.2 [IQR, 93.6-247.0]; p value = 0.003). The linear regression analysis showed that the correlation between KI FGF23 and MED FGF23 was interpreted as a slope of 0.83 with a y-intercept of 0.53, revealing good linearity (R2 = 0.99). This study showed that the discrepancy between KI and MED was very similar to the previously reported data between KI and CL.

2.
J Bone Miner Metab ; 39(6): 1066-1075, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34255195

RESUMO

INTRODUCTION: Measurement of fibroblast growth factor 23 (FGF23) has been reported to be clinically useful for the differential diagnosis of chronic hypophosphatemia. However, assays for research use only are available in Japan. Thus, the objective of this study was to examine the clinical utility of a novel and automated chemiluminescent enzyme immunoassay for the measurement of FGF23. MATERIALS AND METHODS: Participants were recruited from July 2015 to January 2017 at six facilities in Japan. Thirty-eight patients with X-linked hypophosphatemic rickets (XLH 15 males, 23 females, age 0-66 years), five patients with tumour-induced osteomalacia (TIO 3 males, 2 females, age 60-73 years), and twenty-two patients with hypophosphatemia (11 males, 11 females, age 1-75 years) caused due to other factors participated in this study. RESULTS: With the clinical cut-off value of FGF23 at 30.0 pg/mL indicated in the Diagnostic Guideline of Rickets/Osteomalacia in Japan, the sensitivity and specificity of FGF23-related hypophosphatemic rickets/osteomalacia without vitamin D deficiency (disease group-1) were 100% and 81.8%, respectively, which distinguished it from non-FGF23-related hypophosphatemia (disease group-2). Furthermore, the diagnostic sensitivity of FGF23-related hypophosphatemia with vitamin D deficiency remained at 100%. Among the four patients with FGF23 levels ≥ 30.0 pg/mL in disease group-2, two patients with relatively higher FGF23 values were suspected to have genuine FGF23-related hypophosphatemia, due to the ectopic production of FGF23 in pulmonary and prostate small cell carcinomas. CONCLUSION: The novel FGF23 assay tested in this study is useful for the differential diagnosis of hypophosphatemic rickets/osteomalacia in a clinical setting.


Assuntos
Raquitismo Hipofosfatêmico Familiar , Hipofosfatemia , Osteomalacia , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Feminino , Fator de Crescimento de Fibroblastos 23 , Fatores de Crescimento de Fibroblastos , Humanos , Técnicas Imunoenzimáticas , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA