1.
Int J Biomed Imaging ; 2023: 4228321, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37521027

RESUMO

Background: Bariatric surgery is the most effective treatment for morbid obesity and reduces the severity of nonalcoholic fatty liver disease (NAFLD) in the long term. Less is known about the effects of bariatric surgery on liver fat, inflammation, and fibrosis during the early stages following bariatric surgery. Aims: This exploratory study utilises advanced imaging methods to investigate NAFLD and fibrosis changes during the early metabolic transitional period following bariatric surgery. Methods: Nine participants with morbid obesity underwent sleeve gastrectomy. Multiparametric MRI (mpMRI) and magnetic resonance elastography (MRE) were performed at baseline, during the immediate (1 month), and late (6 months) postsurgery period. Liver fat was measured using proton density fat fraction (PDFF), disease activity using iron-correct T1 (cT1), and liver stiffness using MRE. Repeated measured ANOVA was used to assess longitudinal changes and Dunnett's method for multiple comparisons. Results: All participants (Age 45.1 ± 9.0 years, BMI 39.7 ± 5.3 kg/m2) had elevated hepatic steatosis at baseline (PDFF >5%). In the immediate postsurgery period, PDFF decreased significantly from 14.1 ± 7.4% to 8.9 ± 4.4% (p = 0.016) and cT1 from 826.9 ± 80.6 ms to 768.4 ± 50.9 ms (p = 0.047). These improvements continued to the later postsurgery period. Bariatric surgery did not reduce liver stiffness measurements. Conclusion: Our findings support using MRI as a noninvasive tool to monitor NAFLD in patient with morbid obesity during the early stages following bariatric surgery.

2.
Sci Rep ; 8(1): 9189, 2018 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-29907829

RESUMO

LiverMultiScan is an emerging diagnostic tool using multiparametric MRI to quantify liver disease. In a two-centre prospective validation study, 161 consecutive adult patients who had clinically-indicated liver biopsies underwent contemporaneous non-contrast multiparametric MRI at 3.0 tesla (proton density fat fraction (PDFF), T1 and T2* mapping), transient elastography (TE) and Enhanced Liver Fibrosis (ELF) test. Non-invasive liver tests were correlated with gold standard histothological measures. Reproducibility of LiverMultiScan was investigated in 22 healthy volunteers. Iron-corrected T1 (cT1), TE, and ELF demonstrated a positive correlation with hepatic collagen proportionate area (all p < 0·001). TE was superior to ELF and cT1 for predicting fibrosis stage. cT1 maintained good predictive accuracy for diagnosing significant fibrosis in cases with indeterminate ELF, but not for cases with indeterminate TE values. PDFF had high predictive accuracy for individual steatosis grades, with AUROCs ranging from 0.90-0.94. T2* mapping diagnosed iron accumulation with AUROC of 0.79 (95% CI: 0.67-0.92) and negative predictive value of 96%. LiverMultiScan showed excellent test/re-test reliability (coefficients of variation ranging from 1.4% to 2.8% for cT1). Overall failure rates for LiverMultiScan, ELF and TE were 4.3%, 1.9% and 15%, respectively. LiverMultiScan is an emerging point-of-care diagnostic tool that is comparable with the established non-invasive tests for assessment of liver fibrosis, whilst at the same time offering a superior technical success rate and contemporaneous measurement of liver steatosis and iron accumulation.


Assuntos
Fígado Gorduroso , Ferro/metabolismo , Cirrose Hepática , Fígado , Imageamento por Ressonância Magnética/métodos , Adulto , Biópsia , Estudos Transversais , Fígado Gorduroso/diagnóstico por imagem , Fígado Gorduroso/metabolismo , Fígado Gorduroso/patologia , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/metabolismo , Fígado/patologia , Cirrose Hepática/diagnóstico por imagem , Cirrose Hepática/metabolismo , Cirrose Hepática/patologia , Imageamento por Ressonância Magnética/instrumentação , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA