Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Medicine (Baltimore) ; 101(29): e29484, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35866813

RESUMO

BACKGROUNDS: Centrilobular zonal necrosis (CZN) is described as a histological feature present in a small number of autoimmune hepatitis (CZN-AIH) patients. CZN may be detected in the absence of significant interface hepatitis, which is the most important histological finding of AIH. The clinical and histopathological spectra of CZN-AIH were not homogeneous, and the concept of CZN-AIH as a distinctive subtype of AIH remains controversial, due to the rarity of CZN-AIH and the ambiguous definition of CZN. METHODS: To elucidate the clinical and immunogenetic features of CZN-AIH, a total of 102 biopsy samples of AIH, obtained at The Jikei University Katsushika Medical Center and Jikei University Hospital from 2000 to 2018, were reviewed. The 32 patients whose biopsies showed CZN were selected as the CZN-AIH group, and the remaining 70 were grouped as the non-CZN-AIH controls (control AIH). Data on clinical, histopathologic, and immunogenetic features were statistically compared between the CZN-AIH and the control AIH group. Additionally, the impact of the onset pattern (acute or chronic) and coexistent significant interface hepatitis in CZN-AIH was determined. RESULTS: In CZN-AIH, the frequency of acute-onset cases was significantly higher than that in control AIH (56.2% vs 32.9%; P < .05), and the number of cases with moderate-to-severe interface hepatitis in liver histology was significantly lower (37.5% vs 87.1%; P < .001). Compared to the control AIH, cases of CZN-AIH had lower immunoglobulin G level (P < .001), lower antinuclear antibodies titer (P < .001), and lower AIH score (P < .001). The immunogenetic disproportionate distribution of HLA-DR phenotypes in control AIH (increased HLA-DR4 and decreased HLA-DR9) was not found in CZN-AIH. Moreover, CZN-AIH was less frequently relapsed (P < .05). For the acute-onset CZN-AIH cases, the clinical features were hardly indistinguishable from the chronic CZN-AIH cases. Similarly, the existence of interface hepatitis did not influence on the pathophysiology of CZN-AIH. Moreover, the acute-onset CZN-AIH cases is clinically distinguishable from acute-onset control AIH. CONCLUSION: CZN can characterize as a distinct AIH subtype, regardless of onset-pattern or coexistence of significant interface hepatitis. To further strengthen this hypothesis, collection of more CZN-AIH cases is needed.


Assuntos
Hepatite Autoimune , Estudos de Coortes , Antígenos HLA-DR , Hepatite Autoimune/patologia , Humanos , Necrose
2.
J Gastroenterol ; 54(7): 587-596, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-30603885

RESUMO

BACKGROUND: Narrow-band imaging (NBI) classifications for Barrett's esophagus have been proposed for the detection of early esophageal adenocarcinoma. We developed a simplified classification system with demonstrated high diagnostic accuracy and reproducibility among experienced endoscopists, but the feasibility of this system among novice endoscopists was unclear. METHODS: In the present study, eight novice endoscopists with no experience of magnification endoscopy were asked to review 248 images of Barrett's esophagus (72 dysplastic, 176 non-dysplastic) obtained using high-definition magnification endoscopy with NBI 6 weeks before (1st test), immediately after (2nd test), and 6 weeks after (3rd test) being taught the simplified classification system. The primary outcomes were differences in diagnostic accuracy for dysplasia among the three tests. RESULTS: The specificity and overall accuracy improved significantly in the 2nd vs. 1st test [97% vs. 80% (p < 0.001) and 94% vs. 82% (p < 0.001), respectively], but sensitivity was comparable (87% in both tests; p = 0.42). In the 3rd test, the sensitivity and overall accuracy decreased significantly compared with the 2nd test [82% vs. 87% (p < 0.001) and 93% vs. 94% (p < 0.05), respectively], but there was no significant difference in specificity (97% in both tests; p = 0.16). The kappa values for interobserver agreement for the mucosal pattern, vascular pattern, and predicted histology were substantial, and improved significantly in the 2nd vs. 1st test (0.78 vs. 0.59, 0.70 vs. 0.53, and 0.79 vs. 0.66, respectively; p < 0.001 for all). CONCLUSIONS: The simplified NBI classification system may be appropriate for novice endoscopists to use in providing high accuracy and reproducibility.


Assuntos
Adenocarcinoma/diagnóstico , Esôfago de Barrett/diagnóstico , Neoplasias Esofágicas/diagnóstico , Esofagoscopia/métodos , Imagem de Banda Estreita , Idoso , Esôfago de Barrett/classificação , Esôfago de Barrett/patologia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA