Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 86
Filtrar
1.
J Imaging Inform Med ; 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38693333

RESUMO

Ischemic stroke segmentation at an acute stage is vital in assessing the severity of patients' impairment and guiding therapeutic decision-making for reperfusion. Although many deep learning studies have shown attractive performance in medical segmentation, it is difficult to use these models trained on public data with private hospitals' datasets. Here, we demonstrate an ensemble model that employs two different multimodal approaches for generalization, a more effective way to perform on external datasets. First, after we jointly train a segmentation model on diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) MR modalities, the model is inferred on the DWI images. Second, a channel-wise segmentation model is trained by concatenating the DWI and ADC images as input, and then is inferred using both MR modalities. Before training with ischemic stroke data, we utilized BraTS 2021, a public brain tumor dataset, for transfer learning. An extensive ablation study evaluates which strategy learns better representations for ischemic stroke segmentation. In our study, nnU-Net well-known for robustness is selected as our baseline model. Our proposed method is evaluated on three different datasets: the Asan Medical Center (AMC) I and II, and the 2022 Ischemic Stroke Lesion Segmentation (ISLES). Our experiments are widely validated over a large, multi-center, and multi-scanner dataset with a huge amount of 846 scans. Not only stroke lesion models can benefit from transfer learning using brain tumor data, but combining the MR modalities using different training schemes also highly improves segmentation performance. The method achieved a top-1 ranking in the ongoing ISLES'22 challenge and performed particularly well on lesion-wise metrics of interest to neuroradiologists, achieving a Dice coefficient of 78.69% and a lesion-wise F1 score of 82.46%. Also, the method was relatively robust on the AMC I (Dice, 60.35%; lesion-wise F1, 68.30%) and II (Dice; 74.12%; lesion-wise F1, 67.53%) datasets in different settings. The high segmentation accuracy of our proposed method could improve radiologists' ability to detect ischemic stroke lesions in MRI images. Our model weights and inference code are available on https://github.com/MDOpx/ISLES22-model-inference .

2.
Radiologie (Heidelb) ; 2024 Apr 19.
Artigo em Alemão | MEDLINE | ID: mdl-38639916

RESUMO

BACKGROUND: Magnetic resonance (MRI) imaging of the skeletal muscles (muscle MRI for short) is increasingly being used in clinical routine for diagnosis and longitudinal assessment of muscle disorders. However, cross-centre standards for measurement protocol and radiological assessment are still lacking. OBJECTIVES: The aim of this expert recommendation is to present standards for the application and interpretation of muscle MRI in hereditary and inflammatory muscle disorders. METHODS: This work was developed in collaboration between neurologists, neuroradiologists, radiologists, neuropaediatricians, neuroscientists and MR physicists from different university hospitals in Germany. The recommendations are based on expert knowledge and a focused literature search. RESULTS: The indications for muscle MRI are explained, including the detection and monitoring of structural tissue changes and oedema in the muscle, as well as the identification of a suitable biopsy site. Recommendations for the examination procedure and selection of appropriate MRI sequences are given. Finally, steps for a structured radiological assessment are presented. CONCLUSIONS: The present work provides concrete recommendations for the indication, implementation and interpretation of muscle MRI in muscle disorders. Furthermore, it provides a possible basis for the standardisation of the measurement protocols at all clinical centres in Germany.

3.
Nervenarzt ; 2024 Apr 29.
Artigo em Alemão | MEDLINE | ID: mdl-38683354

RESUMO

BACKGROUND: Magnetic resonance (MRI) imaging of the skeletal muscles (muscle MRI for short) is increasingly being used in clinical routine for diagnosis and longitudinal assessment of muscle disorders. However, cross-centre standards for measurement protocol and radiological assessment are still lacking. OBJECTIVES: The aim of this expert recommendation is to present standards for the application and interpretation of muscle MRI in hereditary and inflammatory muscle disorders. METHODS: This work was developed in collaboration between neurologists, neuroradiologists, radiologists, neuropaediatricians, neuroscientists and MR physicists from different university hospitals in Germany. The recommendations are based on expert knowledge and a focused literature search. RESULTS: The indications for muscle MRI are explained, including the detection and monitoring of structural tissue changes and oedema in the muscle, as well as the identification of a suitable biopsy site. Recommendations for the examination procedure and selection of appropriate MRI sequences are given. Finally, steps for a structured radiological assessment are presented. CONCLUSIONS: The present work provides concrete recommendations for the indication, implementation and interpretation of muscle MRI in muscle disorders. Furthermore, it provides a possible basis for the standardisation of the measurement protocols at all clinical centres in Germany.

4.
Radiology ; 310(3): e231429, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38530172

RESUMO

Background Differentiating between benign and malignant vertebral fractures poses diagnostic challenges. Purpose To investigate the reliability of CT-based deep learning models to differentiate between benign and malignant vertebral fractures. Materials and Methods CT scans acquired in patients with benign or malignant vertebral fractures from June 2005 to December 2022 at two university hospitals were retrospectively identified based on a composite reference standard that included histopathologic and radiologic information. An internal test set was randomly selected, and an external test set was obtained from an additional hospital. Models used a three-dimensional U-Net encoder-classifier architecture and applied data augmentation during training. Performance was evaluated using the area under the receiver operating characteristic curve (AUC) and compared with that of two residents and one fellowship-trained radiologist using the DeLong test. Results The training set included 381 patients (mean age, 69.9 years ± 11.4 [SD]; 193 male) with 1307 vertebrae (378 benign fractures, 447 malignant fractures, 482 malignant lesions). Internal and external test sets included 86 (mean age, 66.9 years ± 12; 45 male) and 65 (mean age, 68.8 years ± 12.5; 39 female) patients, respectively. The better-performing model of two training approaches achieved AUCs of 0.85 (95% CI: 0.77, 0.92) in the internal and 0.75 (95% CI: 0.64, 0.85) in the external test sets. Including an uncertainty category further improved performance to AUCs of 0.91 (95% CI: 0.83, 0.97) in the internal test set and 0.76 (95% CI: 0.64, 0.88) in the external test set. The AUC values of residents were lower than that of the best-performing model in the internal test set (AUC, 0.69 [95% CI: 0.59, 0.78] and 0.71 [95% CI: 0.61, 0.80]) and external test set (AUC, 0.70 [95% CI: 0.58, 0.80] and 0.71 [95% CI: 0.60, 0.82]), with significant differences only for the internal test set (P < .001). The AUCs of the fellowship-trained radiologist were similar to those of the best-performing model (internal test set, 0.86 [95% CI: 0.78, 0.93; P = .39]; external test set, 0.71 [95% CI: 0.60, 0.82; P = .46]). Conclusion Developed models showed a high discriminatory power to differentiate between benign and malignant vertebral fractures, surpassing or matching the performance of radiology residents and matching that of a fellowship-trained radiologist. © RSNA, 2024 See also the editorial by Booz and D'Angelo in this issue.


Assuntos
Aprendizado Profundo , Fraturas da Coluna Vertebral , Humanos , Feminino , Masculino , Idoso , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada Multidetectores , Hospitais Universitários
5.
EBioMedicine ; 100: 104982, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38306899

RESUMO

BACKGROUND: Inflammatory demyelinating diseases of the central nervous system, such as multiple sclerosis, are significant sources of morbidity in young adults despite therapeutic advances. Current murine models of remyelination have limited applicability due to the low white matter content of their brains, which restricts the spatial resolution of diagnostic imaging. Large animal models might be more suitable but pose significant technological, ethical and logistical challenges. METHODS: We induced targeted cerebral demyelinating lesions by serially repeated injections of lysophosphatidylcholine in the minipig brain. Lesions were amenable to follow-up using the same clinical imaging modalities (3T magnetic resonance imaging, 11C-PIB positron emission tomography) and standard histopathology protocols as for human diagnostics (myelin, glia and neuronal cell markers), as well as electron microscopy (EM), to compare against biopsy data from two patients. FINDINGS: We demonstrate controlled, clinically unapparent, reversible and multimodally trackable brain white matter demyelination in a large animal model. De-/remyelination dynamics were slower than reported for rodent models and paralleled by a degree of secondary axonal pathology. Regression modelling of ultrastructural parameters (g-ratio, axon thickness) predicted EM features of cerebral de- and remyelination in human data. INTERPRETATION: We validated our minipig model of demyelinating brain diseases by employing human diagnostic tools and comparing it with biopsy data from patients with cerebral demyelination. FUNDING: This work was supported by the DFG under Germany's Excellence Strategy within the framework of the Munich Cluster for Systems Neurology (EXC 2145 SyNergy, ID 390857198) and TRR 274/1 2020, 408885537 (projects B03 and Z01).


Assuntos
Doenças Desmielinizantes , Esclerose Múltipla , Substância Branca , Suínos , Humanos , Animais , Camundongos , Doenças Desmielinizantes/diagnóstico por imagem , Doenças Desmielinizantes/patologia , Cuprizona , Porco Miniatura , Esclerose Múltipla/diagnóstico por imagem , Esclerose Múltipla/patologia , Bainha de Mielina/patologia , Substância Branca/patologia , Microscopia Eletrônica , Modelos Animais de Doenças
6.
Quant Imaging Med Surg ; 13(9): 5472-5482, 2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37711780

RESUMO

Background: To investigate reproducibility of texture features and volumetric bone mineral density (vBMD) extracted from trabecular bone in the thoracolumbar spine in routine clinical multi-detector computed tomography (MDCT) data in a single scanner environment. Methods: Patients who underwent two routine clinical thoraco-abdominal MDCT exams at a single scanner with a time interval of 6 to 26 months (n=203, 131 males; time interval mean, 13 months; median, 12 months) were included in this observational study. Exclusion criteria were metabolic and hematological disorders, bone metastases, use of bone-active medications, and history of osteoporotic vertebral fractures (VFs) or prior diagnosis of osteoporosis. A convolutional neural network (CNN)-based framework was used for automated spine labeling and segmentation (T5-L5), asynchronous Hounsfield unit (HU)-to-BMD calibration, and correction for the intravenous contrast medium phase. Vertebral vBMD and six texture features [varianceglobal, entropy, short-run emphasis (SRE), long-run emphasis (LRE), run-length non-uniformity (RLN), and run percentage (RP)] were extracted for mid- (T5-T8) and lower thoracic (T9-T12), and lumbar vertebrae (L1-L5), respectively. Relative annual changes were calculated in texture features and vBMD for each vertebral level and sorted by sex, and changes were checked for statistical significance (P<0.05) using paired t-tests. Root mean square coefficient of variation (RMSCV) and root mean square error (RMSE) were calculated as measures of variability. Results: SRE, LRE, RLN, and RP exhibited substantial reproducibility with RMSCV-values below 2%, for both sexes and at all spine levels, while vBMD was less reproducible (RMSCV =11.9-16.2%). Entropy showed highest variability (RMSCV =4.34-7.69%) due to statistically significant increases [range, mean ± standard deviation: (4.40±5.78)% to (8.36±8.66)%, P<0.001]. RMSCV of varianceglobal ranged from 1.60% to 3.03%. Conclusions: Opportunistic assessment of texture features in a single scanner environment using the presented CNN-based framework yields substantial reproducibility, outperforming vBMD reproducibility. Lowest scan-rescan variability was found for higher-order texture features. Further studies are warranted to determine, whether microarchitectural changes to the trabecular bone may be assessed through texture features.

7.
Radiother Oncol ; 188: 109901, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37678623

RESUMO

BACKGROUND: Many automatic approaches to brain tumor segmentation employ multiple magnetic resonance imaging (MRI) sequences. The goal of this project was to compare different combinations of input sequences to determine which MRI sequences are needed for effective automated brain metastasis (BM) segmentation. METHODS: We analyzed preoperative imaging (T1-weighted sequence ± contrast-enhancement (T1/T1-CE), T2-weighted sequence (T2), and T2 fluid-attenuated inversion recovery (T2-FLAIR) sequence) from 339 patients with BMs from seven centers. A baseline 3D U-Net with all four sequences and six U-Nets with plausible sequence combinations (T1-CE, T1, T2-FLAIR, T1-CE + T2-FLAIR, T1-CE + T1 + T2-FLAIR, T1-CE + T1) were trained on 239 patients from two centers and subsequently tested on an external cohort of 100 patients from five centers. RESULTS: The model based on T1-CE alone achieved the best segmentation performance for BM segmentation with a median Dice similarity coefficient (DSC) of 0.96. Models trained without T1-CE performed worse (T1-only: DSC = 0.70 and T2-FLAIR-only: DSC = 0.73). For edema segmentation, models that included both T1-CE and T2-FLAIR performed best (DSC = 0.93), while the remaining four models without simultaneous inclusion of these both sequences reached a median DSC of 0.81-0.89. CONCLUSIONS: A T1-CE-only protocol suffices for the segmentation of BMs. The combination of T1-CE and T2-FLAIR is important for edema segmentation. Missing either T1-CE or T2-FLAIR decreases performance. These findings may improve imaging routines by omitting unnecessary sequences, thus allowing for faster procedures in daily clinical practice while enabling optimal neural network-based target definitions.

8.
Front Endocrinol (Lausanne) ; 14: 1222041, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37576975

RESUMO

Objectives: Opportunistic quantitative computed tomography (oQCT) derived from non-dedicated routine CT has demonstrated high accuracy in diagnosing osteoporosis and predicting incident vertebral fractures (VFs). We aimed to investigate the cost-effectiveness of oQCT screening compared to dual-energy X-ray absorptiometry (DXA) as the standard of care for osteoporosis screening. Methods: Three screening strategies ("no osteoporosis screening", "oQCT screening", and "DXA screening") after routine CT were simulated in a state-transition model for hypothetical cohorts of 1,000 patients (women and men aged 65 years) over a follow-up period of 5 years (base case). The primary outcomes were the cumulative costs and the quality-adjusted life years (QALYs) estimated from a U.S. health care perspective for the year 2022. Cost-effectiveness was assessed based on a willingness-to-pay (WTP) threshold of $70,249 per QALY. The secondary outcome was the number of prevented VFs. Deterministic and probabilistic sensitivity analyses were conducted to test the models' robustness. Results: Compared to DXA screening, oQCT screening increased QALYs in both sexes (additional 2.40 per 1,000 women and 1.44 per 1,000 men) and resulted in total costs of $3,199,016 and $950,359 vs. $3,262,934 and $933,077 for women and men, respectively. As a secondary outcome, oQCT screening prevented 2.6 and 2.0 additional VFs per 1,000 women and men, respectively. In the probabilistic sensitivity analysis, oQCT screening remained cost-effective in 88.3% (women) and 90.0% (men) of iterations. Conclusion: oQCT screening is a cost-effective ancillary approach for osteoporosis screening and has the potential to prevent a substantial number of VFs if considered in daily clinical practice.


Assuntos
Osteoporose , Fraturas da Coluna Vertebral , Masculino , Humanos , Feminino , Análise Custo-Benefício , Densidade Óssea , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Programas de Rastreamento/métodos , Fraturas da Coluna Vertebral/diagnóstico por imagem , Fraturas da Coluna Vertebral/epidemiologia
9.
Eur Spine J ; 32(12): 4314-4320, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37401945

RESUMO

PURPOSE: To assess the diagnostic performance of three-dimensional (3D) CT-based texture features (TFs) using a convolutional neural network (CNN)-based framework to differentiate benign (osteoporotic) and malignant vertebral fractures (VFs). METHODS: A total of 409 patients who underwent routine thoracolumbar spine CT at two institutions were included. VFs were categorized as benign or malignant using either biopsy or imaging follow-up of at least three months as standard of reference. Automated detection, labelling, and segmentation of the vertebrae were performed using a CNN-based framework ( https://anduin.bonescreen.de ). Eight TFs were extracted: Varianceglobal, Skewnessglobal, energy, entropy, short-run emphasis (SRE), long-run emphasis (LRE), run-length non-uniformity (RLN), and run percentage (RP). Multivariate regression models adjusted for age and sex were used to compare TFs between benign and malignant VFs. RESULTS: Skewnessglobal showed a significant difference between the two groups when analyzing fractured vertebrae from T1 to L6 (benign fracture group: 0.70 [0.64-0.76]; malignant fracture group: 0.59 [0.56-0.63]; and p = 0.017), suggesting a higher skewness in benign VFs compared to malignant VFs. CONCLUSION: Three-dimensional CT-based global TF skewness assessed using a CNN-based framework showed significant difference between benign and malignant thoracolumbar VFs and may therefore contribute to the clinical diagnostic work-up of patients with VFs.


Assuntos
Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Humanos , Fraturas da Coluna Vertebral/diagnóstico , Coluna Vertebral/patologia , Redes Neurais de Computação , Tomografia Computadorizada por Raios X/métodos , Fraturas por Osteoporose/diagnóstico
10.
J Neurointerv Surg ; 2023 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-37524518

RESUMO

BACKGROUND: Vessel perforation during thrombectomy is a severe complication and is hypothesized to be more frequent during medium vessel occlusion (MeVO) thrombectomy. The aim of this study was to compare the incidence and outcome of patients with perforation during MeVO and large vessel occlusion (LVO) thrombectomy and to report on the procedural steps that led to perforation. METHODS: In this multicenter retrospective cohort study, data of consecutive patients with vessel perforation during thrombectomy between January 1, 2015 and September 30, 2022 were collected. The primary outcomes were independent functional outcome (ie, modified Rankin Scale 0-2) and all-cause mortality at 90 days. Binomial test, chi-squared test and t-test for unpaired samples were used for statistical analysis. RESULTS: During 25 769 thrombectomies (5124 MeVO, 20 645 LVO) in 25 stroke centers, perforation occurred in 335 patients (1.3%; mean age 72 years, 62% female). Perforation occurred more often in MeVO thrombectomy (2.4%) than in LVO thrombectomy (1.0%, p<0.001). More MeVO than LVO patients with perforation achieved functional independence at 3 months (25.7% vs 10.9%, p=0.001). All-cause mortality did not differ between groups (overall 51.6%). Navigation beyond the occlusion and retraction of stent retriever/aspiration catheter were the two most common procedural steps that led to perforation. CONCLUSIONS: In our cohort, perforation was approximately twice as frequent in MeVO than in LVO thrombectomy. Efforts to optimize the procedure may focus on navigation beyond the occlusion site and retraction of stent retriever/aspiration catheter. Further research is necessary in order to identify thrombectomy candidates at high risk of intraprocedural perforation and to provide data on the effectiveness of endovascular countermeasures.

11.
J Neurosurg Spine ; 39(3): 363-369, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37310023

RESUMO

OBJECTIVE: Multiple solutions for navigation-guided pedicle screw placement are currently available. Intraoperative imaging techniques are invaluable for spinal surgery, but often there is little attention paid to patient radiation exposure. This study aimed to compare the applied radiation doses of sliding gantry CT (SGCT)- and mobile cone-beam CT (CBCT)-based pedicle screw placement for spinal instrumentation. METHODS: The authors retrospectively analyzed 183 and 54 patients who underwent SGCT- or standard CBCT-based pedicle screw placement, respectively, for spinal instrumentation at their department between June 2019 and January 2020. SGCT uses an automated radiation dose adjustment. RESULTS: Baseline characteristics, including the number of screws per patient and the number of instrumented levels, did not significantly differ between the two groups. Although the accuracy of screw placement according to Gertzbein-Robbins classification did not differ between the two groups, more screws had to be revised intraoperatively in the CBCT group (SGCT 2.7% vs CBCT 6.0%, p = 0.0036). Mean (± SD) radiation doses for the first (SGCT 484.0 ± 201.1 vs CBCT 687.4 ± 188.5 mGy*cm, p < 0.0001), second (SGCT 515.8 ± 216.3 vs CBCT 658.3 ± 220.1 mGy*cm, p < 0.0001), third (SGCT 531.3 ± 237.5 vs CBCT 641.6 ± 177.3 mGy*cm, p = 0.0140), and total (SGCT 1216.9 ± 699.3 vs CBCT 2000.3 ± 921.0 mGy*cm, p < 0.0001) scans were significantly lower for SGCT. This was also true for radiation doses per scanned level (SGCT 461.9 ± 429.3 vs CBCT 1004.1 ± 905.1 mGy*cm, p < 0.0001) and radiation doses per screw (SGCT 172.6 ± 110.1 vs CBCT 349.6 ± 273.4 mGy*cm, p < 0.0001). CONCLUSIONS: The applied radiation doses were significantly lower using SGCT for navigated pedicle screw placement in spinal instrumentation. A modern CT scanner on a sliding gantry leads to lower radiation doses, especially through automated 3D radiation dose adjustment.


Assuntos
Parafusos Pediculares , Fusão Vertebral , Cirurgia Assistida por Computador , Humanos , Estudos Retrospectivos , Coluna Vertebral/cirurgia , Tomografia Computadorizada de Feixe Cônico/métodos , Cirurgia Assistida por Computador/métodos , Doses de Radiação , Fusão Vertebral/métodos
12.
Clin Neuroradiol ; 33(3): 591-610, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36862232

RESUMO

In 1971, the first computed tomography (CT) scan was performed on a patient's brain. Clinical CT systems were introduced in 1974 and dedicated to head imaging only. New technological developments, broader availability, and the clinical success of CT led to a steady growth in examination numbers. Most frequent indications for non-contrast CT (NCCT) of the head include the assessment of ischemia and stroke, intracranial hemorrhage and trauma, while CT angiography (CTA) has become the standard for first-line cerebrovascular evaluation; however, resulting improvements in patient management and clinical outcomes come at the cost of radiation exposure, increasing the risk for secondary morbidity. Therefore, radiation dose optimization should always be part of technical advancements in CT imaging but how can the dose be optimized? What dose reduction can be achieved without compromising diagnostic value, and what is the potential of the upcoming technologies artificial intelligence and photon counting CT? In this article, we look for answers to these questions by reviewing dose reduction techniques with respect to the major clinical indications of NCCT and CTA of the head, including a brief perspective on what to expect from current and future developments in CT technology with respect to radiation dose optimization.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Humanos , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Angiografia por Tomografia Computadorizada , Angiografia , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
13.
Sci Rep ; 13(1): 5054, 2023 03 28.
Artigo em Inglês | MEDLINE | ID: mdl-36977710

RESUMO

This study aimed to systematically evaluate the impact of dose reduction on image quality and confidence for intervention planning and guidance regarding computed tomography (CT)-based intervertebral disc and vertebral body biopsies. We retrospectively analyzed 96 patients who underwent multi-detector CT (MDCT) acquired for the purpose of biopsies, which were either derived from scanning with standard dose (SD) or low dose (LD; using tube current reduction). The SD cases were matched to LD cases considering sex, age, level of biopsy, presence of spinal instrumentation, and body diameter. All images for planning (reconstruction: "IMR1") and periprocedural guidance (reconstruction: "iDose4") were evaluated by two readers (R1 and R2) using Likert scales. Image noise was measured using attenuation values of paraspinal muscle tissue. The dose length product (DLP) was statistically significantly lower for LD scans regarding the planning scans (SD: 13.8 ± 8.2 mGy*cm, LD: 8.1 ± 4.4 mGy*cm, p < 0.01) and the interventional guidance scans (SD: 43.0 ± 48.8 mGy*cm, LD: 18.4 ± 7.3 mGy*cm, p < 0.01). Image quality, contrast, determination of the target structure, and confidence for planning or intervention guidance were rated good to perfect for SD and LD scans, showing no statistically significant differences between SD and LD scans (p > 0.05). Image noise was similar between SD and LD scans performed for planning of the interventional procedures (SD: 14.62 ± 2.83 HU vs. LD: 15.45 ± 3.22 HU, p = 0.24). Use of a LD protocol for MDCT-guided biopsies along the spine is a practical alternative, maintaining overall image quality and confidence. Increasing availability of model-based iterative reconstruction in clinical routine may facilitate further radiation dose reductions.


Assuntos
Redução da Medicação , Tomografia Computadorizada Multidetectores , Humanos , Estudos Retrospectivos , Doses de Radiação , Biópsia Guiada por Imagem , Processamento de Imagem Assistida por Computador/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos
14.
Acta Neurochir (Wien) ; 165(4): 897-904, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36820888

RESUMO

PURPOSE: Radiolucent anterior and posterior implants by carbon fiber-reinforced polyetheretherketone (CFR PEEK) aim to improve treatment of primary and secondary tumors of the spine during the last years. The aim of this study was to evaluate clinical and radiological outcomes after dorsoventral instrumentation using a CFR PEEK implant in a cohort of patients representing clinical reality. METHODS: A total of 25 patients with tumor manifestation of the thoracic and lumbar spine underwent vertebral body replacement (VBR) using an expandable CFR PEEK implant between January 2021 and January 2022. Patient outcome, complications, and radiographic follow-up were analyzed. RESULTS: A consecutive series aged 65.8 ± 14.7 (27.6-91.2) years were treated at 37 vertebrae of tumor manifestation, including two cases (8.0%) of primary tumor as well as 23 cases (92.0%) of spinal metastases. Overall, 26 cages covering a median of 1 level (1-4) were implanted. Duration of surgery was 134 ± 104 (65-576) min, with a blood loss of 792 ± 785 (100-4000) ml. No intraoperative cage revision was required. Surgical complications were reported in three (12.0%) cases including hemothorax in two cases (one intraoperative, one postoperative) and atrophic wound healing disorder in one case. In two cases (8.0%), revision surgery was performed (fracture of the adjacent tumorous vertebrae, progressive construct failure regarding cage subsidence). No implant failure was observed. CONCLUSION: VBR using CFR PEEK cages represents a legitimate surgical strategy which opens a variety of improvements-especially in patients in need of postoperative radiotherapy of the spine and MRI-based follow-up examinations.


Assuntos
Neoplasias , Fusão Vertebral , Humanos , Fibra de Carbono , Corpo Vertebral , Resultado do Tratamento , Vértebras Lombares/diagnóstico por imagem , Vértebras Lombares/cirurgia , Polietilenoglicóis , Cetonas , Estudos Retrospectivos
15.
Clin Neuroradiol ; 33(2): 271-291, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36416936

RESUMO

The introduction of the first whole-body CT scanner in 1974 marked the beginning of cross-sectional spine imaging. In the last decades, the technological advancement, increasing availability and clinical success of CT led to a rapidly growing number of CT examinations, also of the spine. After initially being primarily used for trauma evaluation, new indications continued to emerge, such as assessment of vertebral fractures or degenerative spine disease, preoperative and postoperative evaluation, or CT-guided interventions at the spine; however, improvements in patient management and clinical outcomes come along with higher radiation exposure, which increases the risk for secondary malignancies. Therefore, technical developments in CT acquisition and reconstruction must always include efforts to reduce the radiation dose. But how exactly can the dose be reduced? What amount of dose reduction can be achieved without compromising the clinical value of spinal CT examinations and what can be expected from the rising stars in CT technology: artificial intelligence and photon counting CT? In this article, we try to answer these questions by systematically reviewing dose reduction techniques with respect to the major clinical indications of spinal CT. Furthermore, we take a concise look on the dose reduction potential of future developments in CT hardware and software.


Assuntos
Inteligência Artificial , Tomografia Computadorizada por Raios X , Humanos , Estudos Transversais , Doses de Radiação , Tomografia Computadorizada por Raios X/métodos , Coluna Vertebral/diagnóstico por imagem
16.
Front Endocrinol (Lausanne) ; 13: 1046547, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36465625

RESUMO

Background: Quantitative magnetic resonance imaging (MRI) techniques such as chemical shift encoding-based water-fat separation techniques (CSE-MRI) are increasingly applied as noninvasive biomarkers to assess the biochemical composition of vertebrae. This study aims to investigate the longitudinal change of proton density fat fraction (PDFF) and T2* derived from CSE-MRI of the thoracolumbar vertebral bone marrow in patients that develop incidental vertebral compression fractures (VCFs), and whether PDFF and T2* enable the prediction of an incidental VCF. Methods: In this study we included 48 patients with CT-derived bone mineral density (BMD) measurements at baseline. Patients that presented an incidental VCF at follow up (N=12, mean age 70.5 ± 7.4 years, 5 female) were compared to controls without incidental VCF at follow up (N=36, mean age 71.1 ± 8.6 years, 15 females). All patients underwent 3T MRI, containing a significant part of the thoracolumbar spine (Th11-L4), at baseline, 6-month and 12 month follow up, including a gradient echo sequence for chemical shift encoding-based water-fat separation, from which PDFF and T2* maps were obtained. Associations between changes in PDFF, T2* and BMD measurements over 12 months and the group (incidental VCF vs. no VCF) were assessed using multivariable regression models. Mixed-effect regression models were used to test if there is a difference in the rate of change in PDFF, T2* and BMD between patients with and without incidental VCF. Results: Prior to the occurrence of an incidental VCF, PDFF in vertebrae increased in the VCF group (ΔPDFF=6.3 ± 3.1%) and was significantly higher than the change of PDFF in the group without VCF (ΔPDFF=2.1 ± 2.5%, P=0.03). There was no significant change in T2* (ΔT2*=1.7 ± 1.1ms vs. ΔT2*=1.1 ± 1.3ms, P=0.31) and BMD (ΔBMD=-1.2 ± 11.3mg/cm3 vs. ΔBMD=-11.4 ± 24.1mg/cm3, P= 0.37) between the two groups over 12 months. At baseline, no significant differences were detected in the average PDFF, T2* and BMD of all measured vertebrae (Th11-L4) between the VCF group and the group without VCF (P=0.66, P=0.35 and P= 0.21, respectively). When assessing the differences in rates of change, there was a significant change in slope for PDFF (2.32 per 6 months, 95% confidence interval (CI) 0.31-4.32; P=0.03) but not for T2* (0.02 per 6 months, CI -0.98-0.95; P=0.90) or BMD (-4.84 per 6 months, CI -23.4-13.7; P=0.60). Conclusions: In our study population, the average change of PDFF over 12 months is significantly higher in patients that develop incidental fractures at 12-month follow up compared to patients without incidental VCF, while T2* and BMD show no significant changes prior to the occurrence of the incidental vertebral fractures. Therefore, a longitudinal increase in bone marrow PDFF may be predictive for vertebral compression fractures.


Assuntos
Fraturas por Compressão , Fraturas da Coluna Vertebral , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Prótons , Medula Óssea/diagnóstico por imagem , Fraturas por Compressão/diagnóstico por imagem , Fraturas da Coluna Vertebral/diagnóstico por imagem , Imageamento por Ressonância Magnética , Água
17.
Front Endocrinol (Lausanne) ; 13: 900356, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35898459

RESUMO

Purpose: Osteoporosis is prevalent and entails alterations of vertebral bone and marrow. Yet, the spine is also a common site of metastatic spread. Parameters that can be non-invasively measured and could capture these alterations are the volumetric bone mineral density (vBMD), proton density fat fraction (PDFF) as an estimate of relative fat content, and failure displacement and load from finite element analysis (FEA) for assessment of bone strength. This study's purpose was to investigate if osteoporotic and osteoblastic metastatic changes in lumbar vertebrae can be differentiated based on the abovementioned parameters (vBMD, PDFF, and measures from FEA), and how these parameters correlate with each other. Materials and Methods: Seven patients (3 females, median age: 77.5 years) who received 3-Tesla magnetic resonance imaging (MRI) and multi-detector computed tomography (CT) of the lumbar spine and were diagnosed with either osteoporosis (4 patients) or diffuse osteoblastic metastases (3 patients) were included. Chemical shift encoding-based water-fat MRI (CSE-MRI) was used to extract the PDFF, while vBMD was extracted after automated vertebral body segmentation using CT. Segmentation masks were used for FEA-based failure displacement and failure load calculations. Failure displacement, failure load, and PDFF were compared between patients with osteoporotic vertebrae versus patients with osteoblastic metastases, considering non-fractured vertebrae (L1-L4). Associations between those parameters were assessed using Spearman correlation. Results: Median vBMD was 59.3 mg/cm3 in osteoporotic patients. Median PDFF was lower in the metastatic compared to the osteoporotic patients (11.9% vs. 43.8%, p=0.032). Median failure displacement and failure load were significantly higher in metastatic compared to osteoporotic patients (0.874 mm vs. 0.348 mm, 29,589 N vs. 3,095 N, p=0.034 each). A strong correlation was noted between PDFF and failure displacement (rho -0.679, p=0.094). A very strong correlation was noted between PDFF and failure load (rho -0.893, p=0.007). Conclusion: PDFF as well as failure displacement and load allowed to distinguish osteoporotic from diffuse osteoblastic vertebrae. Our findings further show strong associations between PDFF and failure displacement and load, thus may indicate complimentary pathophysiological associations derived from two non-invasive techniques (CSE-MRI and CT) that inherently measure different properties of vertebral bone and marrow.


Assuntos
Osteoporose , Prótons , Idoso , Feminino , Análise de Elementos Finitos , Humanos , Vértebras Lombares/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoporose/diagnóstico por imagem , Água
18.
Tomography ; 8(1): 479-496, 2022 02 11.
Artigo em Inglês | MEDLINE | ID: mdl-35202204

RESUMO

An important factor for the development of spinal degeneration, pain and the outcome of spinal surgery is known to be the balance of the spine. It must be analyzed in an upright, standing position to ensure physiological loading conditions and visualize load-dependent deformations. Despite the complex 3D shape of the spine, this analysis is currently performed using 2D radiographs, as all frequently used 3D imaging techniques require the patient to be scanned in a prone position. To overcome this limitation, we propose a deep neural network to reconstruct the 3D spinal pose in an upright standing position, loaded naturally. Specifically, we propose a novel neural network architecture, which takes orthogonal 2D radiographs and infers the spine's 3D posture using vertebral shape priors. In this work, we define vertebral shape priors using an atlas and a spine shape prior, incorporating both into our proposed network architecture. We validate our architecture on digitally reconstructed radiographs, achieving a 3D reconstruction Dice of 0.95, indicating an almost perfect 2D-to-3D domain translation. Validating the reconstruction accuracy of a 3D standing spine on real data is infeasible due to the lack of a valid ground truth. Hence, we design a novel experiment for this purpose, using an orientation invariant distance metric, to evaluate our model's ability to synthesize full-3D, upright, and patient-specific spine models. We compare the synthesized spine shapes from clinical upright standing radiographs to the same patient's 3D spinal posture in the prone position from CT.


Assuntos
Coluna Vertebral , Posição Ortostática , Humanos , Imageamento Tridimensional/métodos , Postura , Radiografia , Coluna Vertebral/diagnóstico por imagem , Coluna Vertebral/fisiologia
19.
Front Oncol ; 11: 761169, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34970486

RESUMO

While the diagnosis of high-grade glioma (HGG) is still associated with a considerably poor prognosis, neurosurgical tumor resection provides an opportunity for prolonged survival and improved quality of life for affected patients. However, successful tumor resection is dependent on a proper surgical planning to avoid surgery-induced functional deficits whilst achieving a maximum extent of resection (EOR). With diffusion magnetic resonance imaging (MRI) providing insight into individual white matter neuroanatomy, the challenge remains to disentangle that information as correctly and as completely as possible. In particular, due to the lack of sensitivity and accuracy, the clinical value of widely used diffusion tensor imaging (DTI)-based tractography is increasingly questioned. We evaluated whether the recently developed multi-level fiber tracking (MLFT) technique can improve tractography of the corticospinal tract (CST) in patients with motor-eloquent HGGs. Forty patients with therapy-naïve HGGs (mean age: 62.6 ± 13.4 years, 57.5% males) and preoperative diffusion MRI [repetition time (TR)/echo time (TE): 5000/78 ms, voxel size: 2x2x2 mm3, one volume at b=0 s/mm2, 32 volumes at b=1000 s/mm2] underwent reconstruction of the CST of the tumor-affected and unaffected hemispheres using MLFT in addition to deterministic DTI-based and deterministic constrained spherical deconvolution (CSD)-based fiber tractography. The brain stem was used as a seeding region, with a motor cortex mask serving as a target region for MLFT and a region of interest (ROI) for the other two algorithms. Application of the MLFT method substantially improved bundle reconstruction, leading to CST bundles with higher radial extent compared to the two other algorithms (delineation of CST fanning with a wider range; median radial extent for tumor-affected vs. unaffected hemisphere - DTI: 19.46° vs. 18.99°, p=0.8931; CSD: 30.54° vs. 27.63°, p=0.0546; MLFT: 81.17° vs. 74.59°, p=0.0134). In addition, reconstructions by MLFT and CSD-based tractography nearly completely included respective bundles derived from DTI-based tractography, which was however favorable for MLFT compared to CSD-based tractography (median coverage of the DTI-based CST for affected vs. unaffected hemispheres - CSD: 68.16% vs. 77.59%, p=0.0075; MLFT: 93.09% vs. 95.49%; p=0.0046). Thus, a more complete picture of the CST in patients with motor-eloquent HGGs might be achieved based on routinely acquired diffusion MRI data using MLFT.

20.
Quant Imaging Med Surg ; 11(7): 2955-2967, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34249626

RESUMO

BACKGROUND: Osteoporosis is a systemic skeletal disease that is characterized by low bone mass and microarchitectural deterioration, predisposing affected individuals to fragility fractures. Yet, standard measurement of areal bone mineral density (BMD) in dual-energy X-ray absorptiometry (DXA) as the current reference standard has limitations for correctly detecting osteoporosis and fracture risk, with opportunistic osteoporosis screening using computed tomography (CT) showing increasing importance. This study's objective is to compare finite element analysis (FEA)-based vertebral failure load with parameters of texture analysis (TA) derived from multi-detector CT (MDCT). METHODS: MDCT data of seven subjects (mean age: 71.9±7.4 years) were included for FEA and TA. Manual segmentation was performed for the vertebral bodies T11, T12, L1, and L2 and the intervertebral discs (IVDs) T11/12, T12/L1, L1/2, and L2/3. Correlation analyses between FEA-derived failure loads and parameters of TA for the single vertebrae and two functional spinal units (FSUs) were calculated, defining FSU-1 as T11-IVD-T12-IVD-L1 and FSU-2 as T12-IVD-L1-IVD-L2. Furthermore, multivariate regressions were performed to identify the texture parameters that predicted the failure load best. RESULTS: For single vertebrae, the strongest correlations were observed for skewnessglobal, kurtosisglobal, and gray level variance (rho =-0.7668 to -0.7362; P<0.001), while for FSUs, SumAverage, long-run emphasis, long-run low gray-level emphasis, homogeneity, and energy showed the strongest correlations (rho =-0.8187 to 0.8407; P<0.05) to failure loads. SumAverage best predicted the failure load for single vertebrae (R2 adj =0.523, P<0.001). For the two FSUs, kurtosisglobal (FSU-1: R2 adj =0.611, P=0.001) and skewnessglobal (FSU-2: R2 adj =0.579, P=0.002) were the best predictors. CONCLUSIONS: TA using MDCT data of the spine was significantly associated with FEA-derived failure loads of both, single vertebrae and FSUs. Texture parameters predicted failure loads of FSUs as a more realistic in-vivo scenario equally well as compared to single vertebrae analyses. TA may reflect a less complex and time-consuming approach to accurately and non-invasively evaluate vertebral bone strength.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA