RESUMO
ABSTRACT We report a fatal subdural empyema caused by Campylobacter rectus in a 66-year-old female who developed acute onset of confusion, dysarthria, and paresis in her left extremities. A CT scan showed hypodensity in a crescentic formation with a mild mid-line shift. She had a bruise on her forehead caused by a fall several days before admission, which initially raised subdural hematoma (SDH) diagnosis, and a burr hole procedure was planned. However, her condition deteriorated on the admission night, and she died before dawn. An autopsy revealed that she had subdural empyema (SDE) caused by Campylobacter rectus and Slackia exigua. Both microorganisms are oral microorganisms that rarely cause extra-oral infection. In our case, head trauma caused a skull bone fracture, and sinus infection might have expanded to the subdural space causing SDE. CT/MRI findings were not typical for either SDH or SDE. Early recognition of subdural empyema and prompt initiation of treatment with antibiotics and surgical drainage is essential for cases of SDE. We present our case and a review of four reported cases.
RESUMO
A high-throughput, fully automated antigen detection test for SARS-CoV-2 is a viable alternative to reverse-transcription polymerase chain reaction (RT-qPCR) for mass screening during outbreaks. In this study, we compared RT-qPCR for viral load and the VITROS® SARS-CoV-2 Antigen Test with reference to the results of the LUMIPULSE® SARS-CoV-2 Ag Test. Of 128 nasopharyngeal swab specimens taken from patients suspected of being infected with SARS-CoV-2, 49 were positive and 79 were negative according to RT-qPCR. Consistent dose-dependent detection with VITROS® assay was successfully achieved when using nasopharyngeal swab specimens with Ct values of 32.0 or lesser, whereas the CLEIA-based LUMIPULSE® assay was able to detect lower viral loads compared with the VITROS® assay. Our results show that the performance of the VITROS® assay was satisfactory for the diagnosis of contagious COVID-19 patients in the clinical setting. Highlights The performance of the VITROS® SARS-CoV-2 Antigen Test was sufficient for the diagnosis of contagious COVID-19. This test showed high sensitivity and specificity in the detection of SARS-CoV-2 in samples with a Ct value of 32 or less.