1.
Phys Eng Sci Med ; 45(4): 1153-1161, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36318385

RESUMO

The high-density measurement (HDm) mode of the ArcCHECK device can achieve a twofold resolution enhancement compared to the standard measurement (Sm) mode. The aim of this study was to evaluate the effect of HDm on the gamma passing rate (GPR) for the patient-specific quality assurance (PSQA) in head and neck cancer. We retrospectively evaluated 30 patients who underwent volumetric modulated arc therapy (VMAT) for head and neck cancer. Absolute gamma analysis was performed on Sm and HDm data. We also investigated correlations between the modulation complexity score for VMAT (MCSv) and differences in the GPR between the two measurement modes. The global GPR of Sm and HDm was 81.0% ± 8.4% and 82.6% ± 7.6% for the 2%/2 mm criterion, 94.0% ± 4.1% and 94.9% ± 3.6% for the 3%/2 mm criterion, and 96.6% ± 2.4% and 97.0% ± 2.4% for the 3%/3 mm criterion, respectively. HDm slightly improved GPR (p < 0.01) for the 2%/2 mm criterion. Differences in GPR between Sm and HDm for the 2%/2 mm, 3%/2 mm, and 3%/3 mm criteria were 1.6% ± 3.0%, 0.8% ± 2.0%, and 0.4% ± 1.2%, respectively. No correlation was identified between the MCSv and the difference in GPR between Sm and HDm. Despite an improvement in GPR with HDm, the difference in GPR between Sm and HDm was approximately 2% even when the tighter criteria were used. Moreover, the change in the GPR between Sm and HDm did not depend on plan complexity. Thus, the effect of HDm on GPR is limited for the PSQA in VMAT for head and neck cancer.


Assuntos
Neoplasias de Cabeça e Pescoço , Radioterapia de Intensidade Modulada , Humanos , Planejamento da Radioterapia Assistida por Computador , Estudos Retrospectivos , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Raios gama
2.
Jpn J Radiol ; 35(9): 511-525, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28647834

RESUMO

The aim of this study was to quantify the effect of multi-leaf collimators (MLCs) with different leaf widths on the planning of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy (VMAT). Toward this objective, dose transmission through a high-definition 120-leaf MLC (HD120MLC) and 120-leaf Millennium MLC (M120MLC) was investigated, using it with a test case and clinical case studies. In test case, studies with IMRT and VMAT plans, the difference in MLC leaf width had a limited effect on planning target volumes (PTVs). Organs at risk (OARs) were more affected by a reduction in dose transmission through the MLC than by a reduction in MLC leaf width. The results of the test case studies and clinical case studies were mostly similar. In the latter, the different MLCs had no effect on the PTV regardless of the treatment method; however, the HD120MLC plans achieved dose reductions to OARs similar to or larger than the dose reduction of the M120MLC plans. The similar results of the test case and clinical case studies showed that despite a limitation of the irradiation field size, the HD120MLC plans were superior.


Assuntos
Neoplasias de Cabeça e Pescoço/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Humanos , Órgãos em Risco , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/instrumentação