Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
JACC Case Rep ; 4(23): 101464, 2022 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-36507289

RESUMO

The management of heart rhythm disorders in patients with adult congenital heart disease and limited vascular access is challenging. We present the case of a 38-year-old woman with Ebstein's anomaly who underwent implantation of a combination of a leadless pacemaker and a subcutaneous implantable cardioverter-defibrillator to manage fatal arrhythmias. (Level of Difficulty: Intermediate.).

2.
J Arrhythm ; 38(3): 400-407, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35785370

RESUMO

Background: Corticosteroids are widely used in patients with cardiac sarcoidosis (CS). In addition, upgrading to cardiac resynchronization therapy (CRT) is sometimes needed. This study aimed to investigate the impact of corticosteroid use on the clinical outcomes following CRT upgrades. Methods: A total of 48 consecutive patients with non-ischemic cardiomyopathies who underwent CRT upgrades were retrospectively reviewed and divided into three groups: group 1 included CS patients taking corticosteroids before the CRT upgrade (n = 7), group 2, CS patients not taking corticosteroids before the CRT upgrade (n = 10), and group 3, non-CS patients (n = 31). The echocardiographic response, heart failure hospitalizations, and cardiovascular deaths were evaluated. Results: The baseline characteristics during CRT upgrades exhibited no significant differences in the echocardiographic data between the three groups. After the CRT upgrade, responses regarding the ejection fraction (EF) and end-systolic volume (ESV) were significantly lower in CS patients than non-CS patients (ΔEF: group 1, 6.7% vs. group 2, 7.7% vs. group 3, 13.6%; p = .039, ΔESV: 3.0 ml vs. -12.7 ml vs. -37.2 ml; p = .008). The rate of an echocardiographic response was lowest in group 1 (29%). There were, however, no significant differences in the cumulative freedom from a composite outcome among the three groups (p = .19). No cardiovascular deaths occurred in group 1. Conclusion: The echocardiographic response to an upgrade to CRT and the long-term prognosis in patients with CS should be carefully evaluated because of the complex etiologies and impact of immunosuppressive therapy.

3.
J Cardiovasc Electrophysiol ; 33(8): 1847-1856, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35761749

RESUMO

INTRODUCTION: The skin overlying cardiovascular implantable electronic devices (CIEDs) sometimes becomes very thin after implantations, which could cause a device erosion. The factors related to the skin thickness of device pockets have not been elucidated. This study aimed to evaluate the skin thickness of CIED pockets and search for the factors associated with the thickness. METHODS: Seventeen skin thickness points around the CIED pocket were measured through ultrasonography in each patient. RESULTS: A total of 101 patients (76 ± 11 years, 26 female) were enrolled. The median duration from the implantation to the examination was 95 months (quartile: 52.5-147.5). The median skin thickness overlying the device was 4.1 mm (3.3-5.9). Patients with heart failure and malignancy had thinner skin overlying the CIED than those without. A significant correlation existed between skin thickness and body mass index (BMI), hemoglobin, serum creatinine, estimated glomerular filtration rate (eGFR), and left ventricular ejection fraction. In contrast, age, gender, and device size did not exhibit a significant correlation with skin thickness. A multivariate logistic regression analysis revealed that chronic heart failure and a decrease in the eGFR and BMI were independent predictive factors of "very thin (≦3.3 mm)" skin of the CIED pocket late after an implantation. CONCLUSION: Aside from a low BMI, the comorbidities (low hemoglobin, heart failure, and renal dysfunction) had a stronger impact on the skin thickness overlying the device than the device size. A careful observation of the device pocket should be performed in patients with those risk factors.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Desfibriladores Implantáveis/efeitos adversos , Eletrônica , Feminino , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/etiologia , Humanos , Marca-Passo Artificial/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Estudos Retrospectivos , Volume Sistólico , Função Ventricular Esquerda
4.
Clin Case Rep ; 9(6): e04198, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-34691467

RESUMO

Atrial tachycardia (AT) in the right atrium often occurs following open-heart surgery. Catheter ablation for these AT is challenging and can lead to unintended conduction block. We performed late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) prior to catheter ablation and predicted wavefront propagation during SR as well as the slow conduction zone during tachycardia. LGE-MRI may assist predicting the conduction disturbance and reducing the risk of unexpected sinus exit block.

5.
J Am Heart Assoc ; 10(7): e019687, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-33759547

RESUMO

Background Medium-dose (25 gray) x-ray radiation therapy has recently been performed on patients with refractory ventricular tachyarrhythmias. Unlike x-ray, carbon ion and proton beam radiation can deliver most of their energy to the target tissues. This study investigated the electrophysiological and pathological changes caused by medium-dose carbon ion and proton beam radiation in the left ventricle (LV). Methods and Results External beam radiation in the whole LV was performed in 32 rabbits. A total of 9 rabbits were not irradiated (control). At the 3-month or 6-month follow-up, the animals underwent an open-chest electrophysiological study and were euthanized for histological analyses. No acute death occurred. Significant LV dysfunction was not seen. The surface ECG revealed a significant reduction in the P and QRS wave voltages in the radiation groups. The electrophysiological study showed that the local conduction times in each LV site were significantly longer and that the local LV bipolar voltages were significantly lower in the radiation groups than in the control rabbits. Histologically, apoptosis, fibrotic changes, and a decrease in the expression of the connexin 43 protein were seen in the LV myocardium. These changes were obvious at 3 months, and the effects were sustained 6 months after radiation. No histological changes were seen in the coronary artery and esophagus, but partial radiation pneumonitis was observed. Conclusions Medium-dose carbon ion and proton beam radiation in the whole LV resulted in a significant electrophysiological disturbance and pathological changes in the myocardium. Radiation of the arrhythmogenic substrate would modify the electrical status and potentially induce the antiarrhythmic effect.


Assuntos
Técnicas Eletrofisiológicas Cardíacas , Ventrículos do Coração , Radioterapia com Íons Pesados , Miocárdio , Lesões Experimentais por Radiação , Taquicardia Ventricular , Função Ventricular Esquerda , Animais , Coelhos , Relação Dose-Resposta à Radiação , Técnicas Eletrofisiológicas Cardíacas/métodos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/efeitos da radiação , Radioterapia com Íons Pesados/métodos , Miocárdio/patologia , Terapia com Prótons/métodos , Lesões Experimentais por Radiação/diagnóstico , Lesões Experimentais por Radiação/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/radioterapia , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda/efeitos da radiação
6.
J Cardiovasc Electrophysiol ; 31(10): 2572-2581, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32648326

RESUMO

BACKGROUND: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are characterized as a wider and more continuous than that after conventional radiofrequency catheter ablation (RFCA) without the contact force (CF)-sensing technology. However, the impact on the lesion characteristics of ablation with a CF-sensing catheter has not been well discussed. We sought to assess the lesions using late-gadolinium enhancement magnetic resonance imaging (LGE-MRI) and to compare the differences between the two groups (CB group vs. RF group). METHODS: A total of 30 consecutive patients who underwent PVI were enrolled (CB group, 18; RF group, 12). The RF applications were delivered with a target lesion size index (LSI) of 5. The PVI lesions were assessed by LGE-MRI 3 months after the PVI. The region around the PV was divided into eight segments: roof, anterior-superior, anterior carina, anterior inferior, bottom, posterior inferior, posterior carina, and posterior superior segment. The lesion width and visual gap of each segment were compared between the two groups. The visual gaps were defined as no-enhancement site of >4 mm. RESULTS: The mean LSI was 4.7 ± 0.7. The lesion width was significantly wider but the visual gaps were more frequently documented at the bottom segment of right PV in the CBA group (lesion width: 8.1 ± 2.2 vs. 6.3 ± 2.2 mm; p = .032; visual gap at the bottom segment or right PV: 39% vs. 0%; p = .016). CONCLUSIONS: The PVI lesion was wider after CBA, while the visual gaps were fewer after RFCA with a CF-sensing catheter.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Ablação por Radiofrequência , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Meios de Contraste , Criocirurgia/efeitos adversos , Gadolínio , Humanos , Imageamento por Ressonância Magnética , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Ablação por Radiofrequência/efeitos adversos , Resultado do Tratamento
7.
J Cardiovasc Electrophysiol ; 30(10): 1830-1840, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31310389

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) lesions after cryoballoon ablation (CBA) are wide and continuous, however, the distribution can depend on the pulmonary vein (PV) size. We sought to assess the relationship between the lesion distribution and PV size after CBA and hotballoon ablation (HBA). METHODS AND RESULTS: A total of 80 consecutive patients who underwent PVI were enrolled (40 with CBA). The lesions were visualized by late-gadolinium enhancement magnetic resonance imaging. The lesion width, lesion gaps, and distance from the PV ostium (PVos) to distal lesion edge (DLE) were assessed. If the DLE extended inside the PV, the value was expressed as a negative value. Although the lesion width was significantly wider in the CB group (7.8 ± 2.0 vs 4.9 ± 1.0 mm, P < .001), the number of lesion gaps was significantly less in the HB group (2.9 ± 2.4 vs 1.3 ± 1.4 gaps, P = .001). The distance from the PVos to DLE was a negative value in both groups, but the impact was significantly greater (-1.5 ± 1.8 vs -0.2 ± 1.2 mm, P < .001) and negatively correlated with PV size in the CB group, but not in HB group (r = -0.27, P = .007). The AF recurrence 12 months after the procedure did not differ (5 [12.5%] of 40 in the CB group vs 4 [10%] of 40 in the HB group, P = .695). CONCLUSIONS: The PVI lesions after HBA were characterized by (a) narrower, but (b) more continuous, (c) smaller lesion inside the PV, and (d) irrespective of PV size as compared to that after CBA.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Meios de Contraste/administração & dosagem , Criocirurgia , Imageamento por Ressonância Magnética , Compostos Organometálicos/administração & dosagem , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiopatologia , Recidiva , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
8.
J Cardiol Cases ; 18(3): 95-98, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30279921

RESUMO

Mycosis fungoides (MF) has been reported to be the most common cutaneous lymphoma with a good prognosis and myocardial infiltration is clinically rare. We hereby report a case of rapidly progressing acute heart failure due to myocardial infiltration by MF. Perfusion cardiac magnetic resonance imaging (MRI) demonstrated a massive perfusion defect in the left ventricle (LV) where multiple nodular enhancement areas by delayed enhancement MRI could be documented in the postero-lateral wall of the LV, which resulted in a deterioration of the LV function and mitral regurgitation. Autopsy confirmed the myocardial infiltration by the MF, which corresponded with the MRI findings. .

9.
J Arrhythm ; 34(5): 572-575, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30327704

RESUMO

A 69-year-old man, who had undergone surgery for mitral and tricuspid regurgitation with the Maze procedure for paroxysmal atrial fibrillation, was admitted with an episode of syncope due to sick sinus syndrome. Three days after implantation of a dual-chamber pacemaker (Accent MRI™, St. Jude Medical Inc.,), ventricular pacing on T-wave was recorded multiple times. St. Jude Medical Inc. pacemakers have a unique additional algorithm, called premature ventricular contraction response, related to preventing pacemaker-mediated tachycardia. This algorithm was determined to be a cause of ventricular pacing on T-wave. We report the limitations and potential adverse effects of such automated algorithms.

12.
J Magn Reson Imaging ; 43(2): 495-503, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26149175

RESUMO

BACKGROUND: To investigate the feasibility of substituting non-contrast-enhanced MR (non-CE-MR) imaging with a two-dimensional (2D) balanced steady-state free precession (b-SSFP) sequence for contrast-enhanced computed tomography (CE-CT) for atrial fibrillation (AF) ablation. METHODS: Fifty-four patients that underwent AF ablation under the guidance of a 3D electro-anatomical mapping system with CE-CT (n = 27) or non-CE-MR images (n = 27) were studied. Procedural results were compared between the two groups. Furthermore, in 22 patients who underwent both CE-CT and non-CE-MRI, two cardiologists independently scored the multiplanar reformatted images on a scale of 1 to 4 (from 1, poor, to 4, excellent). RESULTS: The image score was nearly 0.5 point higher with the CE-CT method. However, the procedural results such as the surface registration error (1.0 [0.8-1.6] mm versus 1.0 [0.8-1.35] mm, P = 0.88) and procedure time (185 [159-199] min versus 185 [142-221] min, P = 0.86) did not significantly differ between the CE-CT and non-CE-MR groups. CONCLUSION: The non-CE-MR method with a 2D-b-SSFP sequence can give us adequate information on AF ablation without any radiation exposure or contrast medium usage


Assuntos
Meios de Contraste , Imageamento por Ressonância Magnética/métodos , Cuidados Pré-Operatórios/métodos , Veias Pulmonares/anatomia & histologia , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X/métodos , Idoso , Fibrilação Atrial/cirurgia , Ablação por Cateter , Estudos de Viabilidade , Feminino , Átrios do Coração/anatomia & histologia , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Reprodutibilidade dos Testes
13.
Europace ; 17(9): 1407-14, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25662988

RESUMO

AIMS: Left bundle branch block (LBBB) induces mechanical dyssynchrony, thereby compromising the coronary circulation in non-ischaemic cardiomyopathy. We sought to examine the effects of cardiac resynchronization therapy (CRT) on coronary flow dynamics and left ventricular (LV) function. METHODS AND RESULTS: Twenty-two patients with non-ischaemic cardiomyopathy (New York Heart Association class, III or IV; LV ejection fraction, ≤35%; QRS duration, ≥130 ms) were enrolled. One week after implantation of the CRT device, coronary flow velocity and pressure in the left anterior descending coronary artery (LAD) and left circumflex coronary artery (LCx) were measured invasively, before and after inducing hyperemia by adenosine triphosphate administration, with two programming modes: sequential atrial and biventricular pacing (BiV) and atrial pacing in patients with LBBB or sequential atrial and right ventricular pacing in patients with complete atrioventricular block (Control). We assessed hyperemic microvascular resistance (HMR, mean distal pressure divided by hyperemic average peak velocity) and the relationship between the change in HMR and mid-term LV reverse remodelling. Hyperemic microvascular resistance was lower during BiV than during Control (LAD: 1.76 ± 0.47 vs. 1.54 ± 0.45, P < 0.001; LCx: 1.92 ± 0.42 vs. 1.73 ± 0.31, P = 0.003). The CRT-induced change in HMR of the LCx correlated with the percentage change in LV ejection fraction (R = -0.598, P = 0.011) and LV end-systolic volume (R = 0.609, P = 0.010) before and 6 months after CRT. CONCLUSION: Cardiac resynchronization therapy improves coronary flow circulation by reducing microvascular resistance, which might be associated with LV reverse remodelling.


Assuntos
Bloqueio de Ramo/fisiopatologia , Terapia de Ressincronização Cardíaca/métodos , Cardiomiopatias/cirurgia , Vasos Coronários/fisiopatologia , Ventrículos do Coração/fisiopatologia , Idoso , Ecocardiografia , Eletrocardiografia , Feminino , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Função Ventricular Esquerda , Remodelação Ventricular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA