Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 32(2): 335-341, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28508148

RESUMO

Due to the high rates of epidural failure (3-32%), novel techniques are required to objectively assess the successfulness of an epidural block. In this study we therefore investigated whether thermographic temperature measurements have a higher predictive value for a successful epidural block when compared to the cold sensation test as gold standard. Epidural anesthesia was induced in 61 patients undergoing elective abdominal, thoracic or orthopedic surgery. A thermographic picture was recorded at 5, 10 and 15 min following epidural anesthesia induction. After 15 min a cold sensation test was performed. Epidural anesthesia is associated with a decrease in skin temperature. Thermography predicts a successful epidural block with a sensitivity of 54% and a PPV of 92% and a specificity of 67% and a NPV of 17%. The cold sensation test shows a higher sensitivity and PPV than thermography (97 and 93%), but a lower specificity and NPV than thermography (25 and 50%). Thermographic temperature measurements can be used as an additional and objective method for the assessment of the effectiveness of an epidural block next to the cold sensation test, but have a low sensitivity and negative predictive value. The local decrease in temperature as observed in our study during epidural anesthesia is mainly attributed to a core-to-peripheral redistribution of body heat and vasodilation.


Assuntos
Anestesia Epidural/métodos , Temperatura Baixa , Temperatura Cutânea , Pele/patologia , Termografia/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Sensibilidade e Especificidade , Limiar Sensorial , Vasodilatação
2.
PLoS One ; 11(2): e0148457, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26844550

RESUMO

PURPOSE: Irreversible electroporation (IRE) uses short duration, high-voltage electrical pulses to induce cell death via nanoscale defects resulting from altered transmembrane potential. The technique is gaining interest for ablations in unresectable pancreatic and hepatobiliary cancer. Metal stents are often used for palliative biliary drainage in these patients, but are currently seen as an absolute contraindication for IRE due to the perceived risk of direct heating of the metal and its surroundings. This study investigates the thermal and tissue viability changes due to a metal stent during IRE. METHODS: IRE was performed in a homogeneous tissue model (polyacrylamide gel), without and with a metal stent placed perpendicular and parallel to the electrodes, delivering 90 and 270 pulses (15-35 A, 90 µsec, 1.5 cm active tip exposure, 1.5 cm interelectrode distance, 1000-1500 V/cm, 90 pulses/min), and in-vivo in a porcine liver (4 ablations). Temperature changes were measured with an infrared thermal camera and with fiber-optic probes. Tissue viability after in-vivo IRE was investigated macroscopically using 5-triphenyltetrazolium chloride (TTC) vitality staining. RESULTS: In the gel, direct stent-heating was not observed. Contrarily, the presence of a stent between the electrodes caused a higher increase in median temperature near the electrodes (23.2 vs 13.3°C [90 pulses]; p = 0.021, and 33.1 vs 24.8°C [270 pulses]; p = 0.242). In-vivo, no temperature difference was observed for ablations with and without a stent. Tissue examination showed white coagulation 1mm around the electrodes only. A rim of vital tissue remained around the stent, whereas ablation without stent resulted in complete tissue avitality. CONCLUSION: IRE in the vicinity of a metal stent does not cause notable direct heating of the metal, but results in higher temperatures around the electrodes and remnant viable tissue. Future studies should determine for which clinical indications IRE in the presence of metal stents is safe and effective.


Assuntos
Eletroporação , Temperatura Alta , Metais , Stents , Animais , Eletrodos , Eletroporação/métodos , Fígado/lesões , Fígado/patologia , Metais/efeitos adversos , Stents/efeitos adversos , Suínos
3.
Epilepsia ; 54(11): e150-4, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24199829

RESUMO

An epilepsy patient with recurring sensorimotor seizures involving the left hand every 10 min, was imaged with a hyperspectral camera during surgery. By calculating the changes in oxygenated, deoxygenated blood, and total blood volume in the cortex, a focal increase in oxygenated and total blood volume could be observed in the sensory cortex, corresponding to the seizure-onset zone defined by intracranial electroencephalography (EEG) findings. This probably reflects very local seizure activity. After multiple subpial transections in this motor area, clinical seizures abated.


Assuntos
Mapeamento Encefálico , Processamento de Imagem Assistida por Computador , Córtex Motor/cirurgia , Convulsões/cirurgia , Adolescente , Mapeamento Encefálico/métodos , Eletroencefalografia/métodos , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Córtex Motor/irrigação sanguínea , Córtex Motor/fisiopatologia , Convulsões/sangue , Convulsões/diagnóstico , Resultado do Tratamento
4.
J Surg Res ; 184(2): 867-72, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23726235

RESUMO

OBJECTIVE: To determine the short-term outcome of radiofrequency ablation (RFA) of pancreatic tissue near the duodenum and portomesenteric vessels (PMV) in a porcine model with and without intraluminal duodenal cooling. BACKGROUND: RFA has been proposed as a new treatment strategy in patients with unresectable locally advanced pancreatic cancer. RFA may cause thermal damage to the duodenum and vascular structures, but these risks and potential protective measures have never been systematically addressed. Intraluminal duodenal cooling during RFA could prevent thermal damage to the duodenum. METHODS: RFA was performed in 11 pigs during laparotomy with a bipolar probe of 30 mm active length at a power of 30 W until a total energy of 15 kJ was administered. The RFA probe was inserted in the pancreas at 5 or 15 mm from the duodenum, PMV, and in the pancreatic tail. RFA near the duodenum was performed with and without intraluminal duodenal cooling using 100 mL/min saline of 5°C. Histopathologic assessment was performed. RESULTS: The maximum RFA-induced temperature was 92°C. RFA with one single probe induced adequate ablation lesions with a diameter of 20 mm over a length of 30 mm. Without duodenal cooling, RFA induced duodenal thermal damage, whereas with duodenal cooling, no damage was observed. RFA at 15 mm from the PMV resulted in minimal superficial focal vascular damage, without thrombosis or hemorrhage. CONCLUSIONS: RFA provides adequate ablation zones in the pancreas of the porcine. Thermal damage to the duodenum can be prevented by intraluminal duodenal cooling without loss of ablation effectivity.


Assuntos
Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Temperatura Baixa , Duodeno/fisiologia , Modelos Animais , Pâncreas/cirurgia , Animais , Crioterapia/métodos , Hemorragia/prevenção & controle , Artérias Mesentéricas/lesões , Pâncreas/irrigação sanguínea , Sistema Porta/lesões , Suínos , Trombose/prevenção & controle , Resultado do Tratamento
5.
J Pediatr Surg ; 39(1): 43-7, 2004 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-14694369

RESUMO

OBJECTIVE: In neonates, initially a ductal shunt is often observed during veno-arterial extracorporeal membrane oxygenation (ECMO). Depending on the degree of pulmonary hypertension in these patients, the ductal shunt will be right to left (R-L), left to right (L-R), or bidirectional. A ductal L-R shunt will possibly lead to pulmonary hyperperfusion and interact with ECMO weaning. The aim of this study was to give more insight in this ductal L-R shunt during ECMO by quantification of this shunt in relation to cardiac output and ECMO flow. METHODS: In 7 lambs, closure of the duct was prevented by infiltration of the ductal wall with 10% formaline. This patent duct could be closed using a vesselloop around the duct. Ultrasound flowprobes were installed around the pulmonary artery, ascending aorta, and around the ECMO circulation tube. Right and left ventricular output and ECMO flow were measured. Ductus flow was defined as ductal left to right shunt (Qduct L-R) = flow in ascending aorta (Qao) - flow in central pulmonary artery (Qpa) and Qduct R-L = Qpa = Qao. RESULTS: In 6 of 7 lambs a ductal L-R shunt was observed with a mean shunt of 44% (range, 11 to 79) of left ventricular output (Qduct L-R/Qao). Comparison with ECMO flow (Qduct L-R/Qecmo) showed a mean shunt of 76% (range 15 to 230). When compared with the total systemic circulating volume (Qpa + flow in the ECMO circuit [Qecmo]), the mean ductal L-R shunt showed a percentage of 51% (range, 7% to 142%). CONCLUSIONS: During ECMO, mostly a ductal L-R shunt is observed in this lamb model. This ductal shunt is hemodynamically important. The percentages of this shunt in comparison with left ventricular output, and total circulating volume will support the idea that a ductal L-R shunt during ECMO could be another deteriorating factor in the often critical circulation of the neonate on veno-arterial ECMO.


Assuntos
Permeabilidade do Canal Arterial/fisiopatologia , Oxigenação por Membrana Extracorpórea , Síndrome da Persistência do Padrão de Circulação Fetal/fisiopatologia , Animais , Circulação Sanguínea , Débito Cardíaco , Modelos Animais de Doenças , Humanos , Recém-Nascido , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA