1.
Vestn Oftalmol ; 140(2. Vyp. 2): 43-50, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739130

RESUMO

PURPOSE: This study investigates the influence of peripheral corneal thickness (PCT) and its curvature on tonometry readings. MATERIAL AND METHODS: The study included 49 patients (49 eyes) who were indicated for glaucoma surgery. Using bidirectional applanation tonometry, the following parameters were obtained: IOPcc, IOPg - intraocular pressure (IOP) corrected for corneal compensation, taken as the most reliable indicator; IOP converted to Goldmann measurement, taken as the result of applanation tonometry, ΔIOP (IOPcc-IOPg), CH and CRF (corneal hysteresis and corneal resistance factor). During corneal topography, the corneal thickness was studied in the center, PCT at 1.5; 2, 3, 4 and 5 mm from the center in four meridians, as well as ΔPCT (PCT 3 mm - PCT 1.5 mm), the curvature of the anterior and posterior surfaces of the cornea and the depth of the anterior chamber. Aberrometry was used to obtain refractometry data and the curvature of the anterior surface of the cornea. The influence of the studied parameters on ΔIOP was evaluated. RESULTS: ΔIOP correlated with CRF (r= -0.652), CH (r= -0.873), central corneal thickness (r= -0.293), PCT at all distances except 5 mm (r= -0.297; -0.287; -0.302; -0.303), with the strong and weak meridians of the anterior surface of the cornea (r=0.328; r=0.315), with the strong and weak meridians of the posterior surface, as well as the average curvature of the posterior surface (r=0.307; r=0.332; r=0.328). After step-by-step selection of the above parameters for creating a linear regression model for ΔIOP calculation, CH, CRF and PCT1.5mm remained in the model. The model describes ΔIOP with high accuracy (R2=0.974). CONCLUSION: Biomechanical parameters of the cornea are the leading factor of applanation tonometry error. Individual linear dimensions of the cornea (thickness, curvature) have a lesser effect.


Assuntos
Córnea , Topografia da Córnea , Glaucoma , Pressão Intraocular , Tonometria Ocular , Humanos , Tonometria Ocular/métodos , Córnea/diagnóstico por imagem , Pressão Intraocular/fisiologia , Masculino , Feminino , Pessoa de Meia-Idade , Topografia da Córnea/métodos , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Reprodutibilidade dos Testes , Idoso , Adulto
2.
Vestn Oftalmol ; 140(2. Vyp. 2): 51-59, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38739131

RESUMO

PURPOSE: The study investigates the influence of changes in keratometric parameters after refractive surgery on the results of Maklakov tonometry. MATERIAL AND METHODS: The study examined a total of 61 people (121 eyes). The patients were divided into a control group with no history of surgery (16 people, 31 eyes), a LASIK group (13 people, 26 eyes), a femtosecond-assisted LASIK (FS-LASIK) group (16 people, 32 eyes), and a photorefractive keratectomy (PRK) group (16 people, 32 eyes). The patients underwent standard examination, keratometry (Km), Maklakov tonometry with a 10 g weight, and elastotonometry with 5, 7.5, and 15 g weights. RESULTS: In the LASIK group, the indentation diameter with 5 and 7.5 g weights correlated with Km in the central and near-paracentral zone (r=0.3-0.5). Tonometry with a 10 g weight did not correlate with anything. Tonometry with a 15 g weight inversely correlated with Km in the paracentral points (4 mm) of the strong meridian (r= -0.5 ... -0.7). In the FS-LASIK group, a significant inverse correlation with Km was observed only for the indentation diameter with a 10 g weight in the paracentral (3-4 mm) zone (r= -0.4 ... -0.5). In the PRK group, weak (r<0.4) correlations were found between Km and the indentation diameter of the 7.5 and 10 g weights for the central zone (1-2 mm). No significant correlations were found for 5 and 15 g weights.In the control group, there were practically no correlations for 5 and 7.5 g weights. The indentation diameter of the 10 g weight evenly correlated with Km at all points (r= -0.38 ... -0.60), the indentation of the 15 g weight correlated mainly with the curvature of the horizontal meridian (r= -0.37 ... -0.49). CONCLUSION: Tonometry readings with the 10 g weight are the most dependent on Km in different groups, and the readings with the 5 g weight are the least dependent. LASIK is characterized by the largest scatter of dependencies for weights of different masses, FS-LASIK - by the smallest. Tonometry readings with the 5 g weight correlated with Km only in the LASIK group, and this was the only direct correlation. Considering the inverse nature of most correlations, higher Km may be associated with an overestimation of tonometry results, and lower Km - with its underestimation.


Assuntos
Ceratomileuse Assistida por Excimer Laser In Situ , Ceratectomia Fotorrefrativa , Tonometria Ocular , Humanos , Adulto , Masculino , Feminino , Tonometria Ocular/métodos , Ceratectomia Fotorrefrativa/métodos , Ceratomileuse Assistida por Excimer Laser In Situ/métodos , Córnea/cirurgia , Córnea/diagnóstico por imagem , Córnea/fisiopatologia , Miopia/cirurgia , Miopia/fisiopatologia , Miopia/diagnóstico , Pressão Intraocular/fisiologia