Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 63
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38724230

RESUMO

OBJECTIVES: Bronchoscopic lung volume reduction with endobronchial valves is a guideline treatment leading to improved pulmonary function, exercise tolerance and quality of life, in patients with advanced emphysema, severe hyperinflation and no collateral ventilation. After valve treatment, loss of the initial lung volume reduction effect can occur, as well as local valve-induced complications such as persistent haemoptysis. In these cases, a surgical lobectomy can be considered to achieve similar efficacy outcomes. We evaluated the safety and feasibility of a video-assisted thoracoscopic surgery lobectomy after valve treatment. METHODS: This single-centre retrospective study included patients who underwent an elective lobectomy after previous valve treatment. Data were evaluated for safety and efficacy for the additional surgical procedure. RESULTS: Twenty-one patients [73% female, median age 67 (7) years, forced expiratory volume in 1 s 29 (7) %pred, and residual volume 223 (58) %pred] were included. There was no 90-day mortality and there were no postoperative intensive care admissions. Pulmonary infections (14%) and prolonged air leak (14%) were the most common complications. In patients who underwent surgery due to loss or lack of effect of valve treatment, a lobectomy led to a significant improvement in pulmonary function; median forced expiratory volume in 1 s +75 (193) ml (P < 0.013), forced vital capacity +450 (572) ml (P = 0.001), residual volume -665 (715) ml (P = 0.005). In patients who underwent a lobectomy because of complications of valve treatment, all complications were resolved after surgery. CONCLUSIONS: We demonstrate that an elective lobectomy after an initial valve treatment is safe and feasible and restores the lung volume reduction effect.

2.
Clin Transplant ; 38(3): e15289, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38486062

RESUMO

INTRODUCTION: Treatment of post lung-transplant airway complications is challenging, and treatment with conventional airway stents is associated with adverse events. More recently, biodegradable airway stents (BDS) have been introduced and may be used to reduce these adverse events. In this study we explore the feasibility of treatment with BDS post lung transplant. METHODS: All patients treated with BDS in The Netherlands were included in this retrospective multicenter study. Feasibility, life span of the stent, occurrence of adverse events, and evolution of lung function were evaluated. RESULTS: Twelve patients (six malacia and six stenosis) received a total of 57 BDS, ranging from 1 to 10 BDS per patient. Six patients had been pretreated with conventional airway stents. Median stent life span was 112 days (range 66-202). No adverse events occurred during stent placement. In 5 out of 57 stent placements, a single additional bronchoscopy was necessary because of mucus accumulation (n = 4) or excessive granulation tissue (n = 1). All stent naïve patients became airway stent independent after treatment; all patients pretreated with conventional airway stents were still airway stent dependent at the end of follow up. CONCLUSION: Treatment with BDS is safe and feasible. Adverse events were mild and easily treatable. All patients with initial treatment with BDS were airway stent independent at the end of follow up with a median treatment of 4 BDS.


Assuntos
Transplante de Pulmão , Humanos , Broncoscopia , Constrição Patológica/etiologia , Transplante de Pulmão/efeitos adversos , Complicações Pós-Operatórias/etiologia , Stents/efeitos adversos , Resultado do Tratamento
3.
Respiration ; 102(12): 1003-1006, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37939683

RESUMO

INTRODUCTION: Endobronchial valve (EBV) treatment has been shown to be beneficial for patients with severe emphysema. The forced expiratory volume in 1 s (FEV1) was found to be significantly higher compared to baseline for up to 3 years after treatment although the magnitude of improvement gradually decreases over time. So far, it has not been investigated whether this treatment decelerates the decline in lung function. Therefore, our aim was to investigate the lung function decline before and after EBV treatment. METHODS: We included patients who were treated with EBVs in our hospital, of whom pre-treatment spirometry results were available (at least 4 measurements within at least 2 years before treatment) and who had an annual FEV1 measurement up to 3 years after treatment. RESULTS: In total, 45 patients were included (73% female, FEV1: 28 ± 7% of predicted, residual volume: 232 ± 32% of predicted) who had a mean pre-treatment FEV1 decline of -64 mL/year. Mean FEV1 "decline" after treatment was +13 mL/year, since FEV1 was still above the baseline level at 3-year follow-up. However, the FEV1 decline between 1 and 3 years of follow-up was not significantly different compared to the pre-treatment decline (-73 mL/year, p = 0.179). CONCLUSIONS: Our results show that the EBV treatment does not influence the progression of disease in terms of lung function decline. However, the treatment does improve the FEV1 up to a level that is still comparable 3 years after treatment with the baseline level.


Assuntos
Enfisema Pulmonar , Humanos , Feminino , Masculino , Volume Expiratório Forçado , Resultado do Tratamento , Medidas de Volume Pulmonar , Pneumonectomia/métodos , Pulmão , Broncoscopia/métodos
4.
Respiration ; 102(6): 454-457, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37231891

RESUMO

Bronchoscopic lung volume reduction using endobronchial valves (EBVs) is a treatment option for patients with severe emphysema. These EBVs are made out of a nitinol mesh covered by a silicone layer. Nitinol is an alloy of nickel and titanium and is commonly used in implantable medical devices because of its biocompatibility and memory-shape properties. However, there are some concerns that nickel ions can be released from nitinol-containing devices which might cause adverse health effects, especially in patients with a known nickel hypersensitivity. In vitro, it was found that EBV release significant amounts of nickel in the first hours. Our aim was to assess the nickel concentration in lung tissue from a patient who previously underwent EBV treatment but, due to treatment failure, underwent lung volume reduction surgery and to compare this to a reference sample. We found no significant difference in the median nickel concentration between the EBV-treated patient and the non-EBV-treated patient (0.270 vs. 0.328 µg/g, respectively, p = 0.693) and these concentrations were also comparable to previously published nickel concentrations in human lung tissue samples not having any medically implanted devices in the lung. Our results suggest that there is no significant long-term nickel deposition in lung tissue after EBV treatment.


Assuntos
Pulmão , Níquel , Pneumonectomia , Próteses e Implantes , Humanos , Broncoscopia , Pulmão/química , Níquel/análise , Pneumonectomia/instrumentação , Pneumonectomia/métodos , Próteses e Implantes/efeitos adversos , Enfisema Pulmonar/cirurgia , Resultado do Tratamento , Feminino , Pessoa de Meia-Idade
5.
Respir Med ; 210: 107175, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36858325

RESUMO

BACKGROUND: Bronchoscopic lung volume reduction using endobronchial valves (EBV) is a treatment option for selected patients with advanced emphysema. The treatment significantly improves pulmonary function, exercise capacity, quality of life, and potentially improves survival. Our main aim was to assess whether treatment response significantly influences survival time after EBV treatment. METHODS: We evaluated treatment response at 6-week and 1-year follow-up of all patients treated with EBVs between 2008 and 2020. Survival status was retrieved on December 1, 2021. Patients were defined as responders or non-responders based on known minimal important differences for FEV1, residual volume (RV), RV/Total Lung Capacity (TLC) ratio, 6-min walk distance (6MWD), St. George's Respiratory Questionnaire (SGRQ), target lobe volume reduction (TLVR), and complete lobar atelectasis. Uni- and multivariate cox regression models were used to evaluate the effect of response on survival time. RESULTS: A total of 428 patients were included. EBV treatment resulted in significant improvements in pulmonary function, exercise capacity and quality of life. Median survival was 8.2 years after treatment. SGRQ and 6MWD response were independent predictors for improved survival time (Hazard Ratio (HR) 0.50 [0.28-0.89], p = .02 and HR 0.54 [0.30-0.94], p = .03, respectively). The presence of a complete lobar atelectasis did not significantly affect survival, neither did pulmonary function improvements. CONCLUSIONS: Our results suggest that improvement in exercise capacity and quality of life after EBV treatment are associated with a survival benefit, independent of improvements in pulmonary function, reduction in target lobe volume or the presence of complete lobar atelectasis.


Assuntos
Atelectasia Pulmonar , Enfisema Pulmonar , Humanos , Tolerância ao Exercício/fisiologia , Qualidade de Vida , Broncoscopia/métodos , Volume Expiratório Forçado/fisiologia , Pneumonectomia/métodos , Atelectasia Pulmonar/etiologia , Resultado do Tratamento
7.
Respiration ; 102(3): 203-206, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36529120

RESUMO

BACKGROUND: The COVID-19 pandemic has a great impact on numberless aspects of our society. In our bronchoscopic lung volume reduction interventional program, we work with severe COPD patients on a daily basis. OBJECTIVES: We were interested in the prevalence and outcome of COVID-19, impact of the pandemic on daily life, and the vaccination coverage in our severe COPD patients who have been treated with one-way endobronchial valves. METHOD: A questionnaire, which consisted of questions related to the infection rate, treatment, and outcome of COVID-19 infections; feelings of anxiety related to the pandemic; adherence to preventive measures; and willingness to be vaccinated; was sent to our patients in June 2021. RESULTS: The questionnaire was sent to 215 patients, and the response rate was 100%. The vaccination rate was 97% in our surveyed population. The majority of patients (63%) indicated that they were quite or very anxious to get infected with COVID-19. Twenty-five (11.5%) patients were diagnosed with COVID-19, with none of these patients having been vaccinated at the time of infection. The infection rate reported in this study is comparable to that of the general Dutch population. However, the hospital admission rate and mortality rates are higher. CONCLUSIONS: Our results show that the SARS-CoV-2 infection rate in severe COPD patients treated with endobronchial valves was comparable with the general population; however, the hospital admission and mortality rates were worse.


Assuntos
COVID-19 , Doença Pulmonar Obstrutiva Crônica , Humanos , Pneumonectomia/métodos , Prevalência , Pandemias , Broncoscopia/métodos , SARS-CoV-2 , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/cirurgia
8.
Respiration ; 102(2): 164-172, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36543148

RESUMO

BACKGROUND: Chest computed tomography (CT) emphysema quantification is a vital diagnostic tool in patient evaluation for bronchoscopic lung volume reduction (BLVR). Smooth kernels for CT image reconstruction are generally recommended for quantitative analyses. This recommendation is not always followed, which may affect quantification of emphysema extent and eventually, treatment decisions. OBJECTIVE: The main goal is to demonstrate the influence of CT reconstruction kernels on emphysema quantification in patients with severe COPD, considered for BLVR. METHODS: Chest CT scans were acquired with one multi-detector CT system and reconstructed using three different kernels: smooth, medium smooth, and sharp. Other parameters were kept constant. Emphysema scores (ESs), meaning the percentage of voxels below -950 Hounsfield units, were calculated and compared to the smooth reference kernel using paired t tests. Bland-Altman plots were made to assess the biases and limits of agreement between kernels. RESULTS: Ninety-eight COPD patient CT scans were analyzed. The sharp kernel had a systematic bias of 6.2% and limits of agreement of 16.6% to -4.2% compared to the smooth kernel. The medium smooth kernel had a systematic bias of 5.7% and limits of agreement of 9.2% and 2.2% compared to the smooth kernel. The ES differed, for a single patient, up to 18% for different kernels. CONCLUSIONS: Chest CT kernel reconstruction can lead to a significant difference in emphysema severity quantification. This may cause invalid treatment selection in COPD patients evaluated for BLVR. Standardization of a smooth CT kernel setting and/or normalization to a standard kernel is strongly recommended.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Pneumonectomia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Doença Pulmonar Obstrutiva Crônica/complicações , Doença Pulmonar Obstrutiva Crônica/diagnóstico por imagem , Doença Pulmonar Obstrutiva Crônica/cirurgia , Tomografia Computadorizada Multidetectores , Enfisema/cirurgia
9.
Respiration ; 102(2): 134-142, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36549279

RESUMO

BACKGROUND: Bronchoscopic lung volume reduction using one-way endobronchial valves (EBVs) is a valid therapy for severe emphysema patients. However, alpha-1 antitrypsin (AAT)-deficient patients were excluded from the majority of clinical trials investigating this intervention. OBJECTIVES: The aim of this study was to investigate the feasibility, efficacy, and safety of EBV treatment in patients with AAT deficiency (AATD) or a reduced AAT level. METHOD: A retrospective analysis was performed of all patients treated with EBV with confirmed AATD or with a reduced AAT serum level at the University Medical Center Groningen between 2013 and 2021. Baseline and 6-month follow-up assessment included chest CT, pulmonary function measurement, 6-min walking distance (6MWD), and St. George's Respiratory Questionnaire (SGRQ). RESULTS: In total, 53 patients were included, 30 patients in the AATD group (AAT <0.6 g/L or confirmed ZZ phenotype) and 23 patients in the reduced AAT group (AAT 0.6-1 g/L). In both groups, all response variables improved significantly after treatment. There was a median increase in forced expiratory volume in 1 s of 105 mL (12% relative) and 280 mL (31% relative) in the AATD and reduced AAT groups, respectively. 6MWD increased by 62 min and 52 min, and SGRQ decreased by 12.5 patients and 18.7 patients, respectively. A pneumothorax occurred in 10% and 13% of patients, and no patients died. CONCLUSIONS: EBV treatment in patients with emphysema and AATD or a reduced AAT level is feasible and results in significant improvements in pulmonary function, exercise capacity, and quality of life and has an acceptable safety profile.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Deficiência de alfa 1-Antitripsina , Humanos , Pneumonectomia/métodos , Estudos Retrospectivos , Qualidade de Vida , Deficiência de alfa 1-Antitripsina/complicações , Deficiência de alfa 1-Antitripsina/cirurgia , alfa 1-Antitripsina
10.
Respir Med ; 203: 106989, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36166995

RESUMO

INTRODUCTION: Treatment with AeriSeal is an alternate treatment option to achieve lung volume reduction in patients with severe COPD and emphysema who are not eligible for valve treatment. This study aimed to assess the safety and mode of action of a modified staged treatment algorithm with a staged treatment with lower dose of AeriSeal. METHODS: We performed a prospective, multicenter feasibility study. AeriSeal was administered during two sequential bronchoscopies: 2 subsegments of a lobe treated with two 5 mL doses, followed by two 10 mL doses in a contralateral lobe after 6 weeks. RESULTS: A total of 14 patients (36% male, mean FEV1 28.4% ± 6.7% of predicted) were enrolled. Ten patients completed both treatments, four were treated unilaterally. AeriSeal treatment resulted in significant TLVR (median 220.5 mL) at 3 months follow up. There were no significant changes from baseline at 12 months in lung function, exercise capacity and quality of life. During the 3-month post-treatment period, respiratory SAEs included 5 COPD exacerbations in 4 (28.6%) subjects, post-treatment acute inflammatory response (PAIR) in 2 (14.3%) subjects, and 1 respiratory failure event in 1 (7.1%) subject. CONCLUSION: The staged and lower dosed administration of AeriSeal does not impact the overall safety profile in terms of reducing the type and frequency of respiratory SAEs previously reported for a single-stage treatment. A larger volume of AeriSeal than used in this study may be necessary to provide meaningful clinical benefits.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Humanos , Masculino , Feminino , Qualidade de Vida , Estudos Prospectivos , Resultado do Tratamento , Broncoscopia/métodos , Pneumonectomia/métodos , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Doença Pulmonar Obstrutiva Crônica/etiologia , Algoritmos , Volume Expiratório Forçado/fisiologia
11.
Respiration ; 101(7): 697-705, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35405678

RESUMO

BACKGROUND: Lung volume reduction coil (LVR-coil) treatment provides a minimally invasive treatment option for severe emphysema patients which has been studied in multiple clinical trials. OBJECTIVES: The aim of the study was to assess the effect of LVR-coil treatment on pulmonary function, quality of life, and exercise capacity using individual participant data. METHOD: PubMed, Web of Science, and EMBASE were searched until May 17, 2021. Prospective single-arm and randomized controlled trials that evaluated the effect of LVR-coil treatment on forced expiratory volume in 1 s (FEV1), residual volume (RV), St. George Respiratory Questionnaire (SGRQ) total score, and/or 6-min walk distance (6MWD) and were registered in an official clinical trial database were eligible for inclusion. Individual patient data were requested, and a linear mixed effects model was used to calculate overall treatment effects. RESULTS: Eight trials were included in the final analysis, representing 680 individual patients. LVR-coil treatment resulted in a significant improvement in FEV1 at 3- (0.09 L [95% confidence interval (95% CI): 0.06-0.12]) and 6-month follow-up (0.07 L [95% CI: 0.03-0.10]), a significant reduction in RV at 3- (-0.45L [95% CI: -0.62 to -0.28]), 6- (-0.33L [95% CI: -0.52 to -0.14]), and 12-month follow-up (-0.36L [95% CI: -0.64 to -0.08]), a significant reduction in SGRQ total score at 3- (-12.3 points [95% CI: -15.8 to -8.8]), 6- (-10.1 points [95% CI: -12.8 to -7.3]), and 12-month follow-up (-9.8 points [95% CI: -15.0 to -4.7]) and a significant increase in 6MWD at 3-month follow-up (38 m [95% CI: 18-58]). CONCLUSIONS: LVR-coil treatment in emphysema patients results in sustained improvements in pulmonary function and quality of life and shorter lived improvements in exercise capacity. Since the owner of this LVR-coil has decided to stop the production and newer generations LVR-coils are currently being developed, these results can act as a reference for future studies and clinical guidance.


Assuntos
Enfisema , Enfisema Pulmonar , Broncoscopia/métodos , Enfisema/cirurgia , Volume Expiratório Forçado , Humanos , Pneumonectomia/métodos , Estudos Prospectivos , Enfisema Pulmonar/cirurgia , Qualidade de Vida , Resultado do Tratamento
12.
Respir Med ; 196: 106825, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35325741

RESUMO

BACKGROUND AND OBJECTIVE: Severe COPD patients can significantly benefit from bronchoscopic lung volume reduction (BLVR) treatments with coils or endobronchial valves. However, the potential impact of BLVR on survival is less understood. Therefore, our aim was to investigate the survival rate in patients who are evaluated for BLVR treatment and whether there is a difference in survival rate between patients who undergo BLVR treatment and patients who do not. METHODS: We included patients with COPD who visited our hospital for a consultation evaluating their eligibility for BLVR treatment and who performed pulmonary function tests during this visit. Furthermore, vital status was verified. RESULTS: In total 1471 patients were included (63% female, mean age 61 years). A total of 531 patients (35%) died during follow-up and the median survival time of the total population was 2694 days (95% confidence interval(CI) 2462-2926) which is approximately 7.4 years. The median survival time of patients who were treated with BLVR was significantly longer compared to patients who were not treated with BLVR (3133 days versus 2503 days, p < 0.001), and BLVR was found to be an independent predictor of survival when adjusting for other survival-influencing factors such as age, gender or severity of disease. CONCLUSIONS: Our results suggest that bronchoscopically reducing lung volume in patients with severe hyperinflation may lead to a survival benefit for a population with a severely reduced life expectancy.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Broncoscopia/métodos , Feminino , Humanos , Medidas de Volume Pulmonar , Masculino , Pessoa de Meia-Idade , Pneumonectomia/métodos , Resultado do Tratamento
13.
Ann Thorac Surg ; 113(5): e375-e377, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34314690

RESUMO

Symptomatic airway kinking after bronchoscopic lung volume reduction with endobronchial valves is rare. Owing to the development of the desired lobar atelectasis, the position of the airways of the nontreated lobe changes, and that might lead to invalidating symptoms. We present a case of a patient with symptomatic airway kinking after treatment with endobronchial valves, who was successfully treated with a single placement of a biodegradable stent. Placement of a biodegradable stent can be considered for symptomatic patients with airway kinking.


Assuntos
Pneumonectomia , Atelectasia Pulmonar , Broncoscopia , Humanos , Implantação de Prótese , Atelectasia Pulmonar/etiologia , Atelectasia Pulmonar/cirurgia , Stents
14.
Respiration ; 100(10): 969-978, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34062550

RESUMO

For selected patients with advanced emphysema, bronchoscopic lung volume reduction with one-way valves can lead to clinically relevant improvements of airflow obstruction, hyperinflation, exercise capacity, and quality of life. The most common complication of this procedure is pneumothorax with a prevalence of up to ±34% of the treated patients. Patients who develop a pneumothorax also experience meaningful clinical benefits once the pneumothorax is resolved. Timely resolution of a post-valve treatment pneumothorax requires skilled and adequate pneumothorax management. This expert panel statement is an updated recommendation of the 2014 statement developed to help guide pneumothorax management after valve placement. Additionally, mechanisms for pneumothorax development, risk assessment, prevention of pneumothorax, and outcomes after pneumothorax are addressed. This recommendation is based on a combination of the current scientific literature and expert opinion, which was obtained through a modified Delphi method.


Assuntos
Enfisema , Pneumotórax , Enfisema Pulmonar , Broncoscopia/métodos , Humanos , Pneumonectomia/efeitos adversos , Pneumonectomia/métodos , Pneumotórax/etiologia , Pneumotórax/terapia , Enfisema Pulmonar/complicações , Qualidade de Vida , Resultado do Tratamento
15.
Respiration ; 100(8): 804-810, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33965944

RESUMO

BACKGROUND: Bronchoscopic lung volume reduction using endobronchial coils is a new treatment for patients with severe emphysema. To date, the benefits have been modest and have been suggested to be much larger in patients with severe hyperinflation and nonmulti-comorbidity. OBJECTIVE: We aimed to evaluate the efficacy and safety of endobronchial coil treatment in a randomized multicenter clinical trial using optimized patient selection. METHOD: Patients with severe emphysema on HRCT scan with severe hyperinflation (residual volume [RV] ≥200% predicted and RV/total lung capacity [TLC] >55%) were randomized to coil treatment or control. Primary outcome measures were differences in the forced expiratory volume in 1 s (FEV1) and St George's Respiratory Questionnaire (SGRQ) total score at 6 months. RESULTS: Due to premature study termination, a total of 120 patients (age 63 ± 7 years, FEV1 29 ± 7% predicted, RV 251 ± 41% predicted, RV/TLC 67 ± 6%, and SGRQ 58 ± 13 points), instead of 210 patients, were randomized. At study termination, 91 patients (57 coil and 34 control) had 6-month results available. Analyses showed significantly greater improvements in favor of the coil group. The increase in FEV1 was greater in the coil group than that in the control group by + 10.3 [+4.7 to +16.0] % and in SGRQ by -10.6 [-15.9 to -5.4] points. At study termination, there were 5 (6.8%) deaths in the coil cohort reported. CONCLUSION: Despite early study termination, coil treatment compared to control results in a significant improvement in the lung function and quality of life benefits for up to 6 months in patients with emphysema and severe hyperinflation. These improvements were of clinical importance but were associated with a higher likelihood of serious adverse events.


Assuntos
Broncoscopia , Enfisema/terapia , Pneumonectomia/instrumentação , Adulto , Idoso , Idoso de 80 Anos ou mais , Término Precoce de Ensaios Clínicos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonectomia/métodos , Estudos Prospectivos , Próteses e Implantes , Índice de Gravidade de Doença
16.
Int J Chron Obstruct Pulmon Dis ; 16: 1127-1136, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33911858

RESUMO

Background: Endobronchial valve (EBV) treatment is an effective treatment for patients with severe emphysema. Revision bronchoscopies after endobronchial valve treatment can be essential to prolong the effect of treatment or address long-term complications. Purpose: To evaluate the indications, endoscopic findings and outcomes of revision bronchoscopies and investigate if any predictors for granulation tissue formation, after EBV treatment, can be identified. Patients and Methods: Patients who underwent EBV treatment between 2016 and 2019 in our hospital, as routine care, were included. If a patient underwent a revision bronchoscopy, data regarding revision bronchoscopies, including indication, finding, intervention and pulmonary function testing (PFT) after revision bronchoscopy were analysed. Results: One hundred seventy-nine patients were included of which 41% required at least one revision bronchoscopy. In 43% of the revision bronchoscopy patients, the indication was loss of initial treatment effect. In 53% of the revision bronchoscopy patients, granulation tissue was found to be the underlying cause. Valve replacement(s) were performed in 51% of the revision bronchoscopy cases. Permanent valve removal was required in 13% of all patients. Overall, revision bronchoscopies led to improvements in PFT outcomes for patients experiencing no or a loss of initial treatment effect. No clinically relevant predictors for granulation tissue formation were identified. Conclusion: Performing a revision bronchoscopy after EBV treatment is a useful procedure leading to an improved treatment effect in most patients. Granulation tissue formation, causing valve dysfunction, is the most common cause of longer term problems.


Assuntos
Enfisema , Doença Pulmonar Obstrutiva Crônica , Enfisema Pulmonar , Broncoscopia/efeitos adversos , Humanos , Pneumonectomia/efeitos adversos , Doença Pulmonar Obstrutiva Crônica/cirurgia , Enfisema Pulmonar/diagnóstico por imagem , Enfisema Pulmonar/cirurgia , Resultado do Tratamento
17.
Respiration ; 100(5): 443-451, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33744899

RESUMO

BACKGROUND: So far, 3 randomized controlled trials have shown that the endobronchial treatment using coils is safe and effective. However, the more exact underlying mechanism of the treatment and best predictors of response are unknown. OBJECTIVES: The aim of the study was to gain more knowledge about the underlying physiological mechanism of the lung volume reduction coil treatment and to identify potential predictors of response to this treatment. METHODS: This was a prospective nonrandomized single-center study which included patients who were bilaterally treated with coils. Patients underwent an extensive number of physical tests at baseline and 3 months after treatment. RESULTS: Twenty-four patients (29% male, mean age 62 years, forced expiratory volume in 1 s [FEV1] 26% pred, residual volume (RV) 231% pred) were included. Three months after treatment, significant improvements were found in spirometry, static hyperinflation, air trapping, airway resistance, treated lobe RV and treated lobes air trapping measured on CT scan, exercise capacity, and quality of life. The change in RV and airway resistance was significantly associated with a change in FEV1, forced vital capacity, air trapping, maximal expiratory pressure, dynamic compliance, and dynamic hyperinflation. Predictors of treatment response at baseline were a higher RV, larger air trapping, higher emphysema score in the treated lobes, and a lower physical activity level. CONCLUSIONS: Our results confirm that emphysema patients benefit from endobronchial coil treatment. The primary mechanism of action is decreasing static hyperinflation with improvement of airway resistance which consequently changes dynamic lung mechanics. However, the right patient population needs to be selected for the treatment to be beneficial which should include patients with severe lung hyperinflation, severe air trapping, and significant emphysema in target lobes.


Assuntos
Pulmão/fisiopatologia , Pneumonectomia/métodos , Enfisema Pulmonar/cirurgia , Feminino , Humanos , Pulmão/cirurgia , Masculino , Pessoa de Meia-Idade , Pneumonectomia/efeitos adversos , Pneumonectomia/instrumentação , Estudos Prospectivos , Enfisema Pulmonar/fisiopatologia , Volume Residual , Testes de Função Respiratória , Resultado do Tratamento
18.
Lung ; 199(2): 195-198, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33687513

RESUMO

PURPOSE: For this study, we aimed to compare dynamic hyperinflation measured by cardiopulmonary exercise testing (CPET), a six-minute walking test (6-MWT), and a manually paced tachypnea test (MPT) in patients with severe emphysema who were treated with endobronchial coils. Additionally, we investigated whether dynamic hyperinflation changed after treatment with endobronchial coils. METHODS: Dynamic hyperinflation was measured with CPET, 6-MWT, and an MPT in 29 patients before and after coil treatment. RESULTS: There was no significant change in dynamic hyperinflation after treatment with coils. Comparison of CPET and MPT showed a strong association (rho 0.660, p < 0.001) and a moderate agreement (BA-plot, 202 ml difference in favor of MPT). There was only a moderate association of the 6-MWT with CPET (rho 0.361, p 0.024). CONCLUSION: MPT can be a suitable alternative to CPET to measure dynamic hyperinflation in severe emphysema but may overestimate dynamic hyperinflation possibly due to a higher breathing frequency.


Assuntos
Capacidade Inspiratória/fisiologia , Enfisema Pulmonar/diagnóstico , Enfisema Pulmonar/fisiopatologia , Mecânica Respiratória/fisiologia , Adulto , Idoso , Broncoscopia , Teste de Esforço , Tolerância ao Exercício/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pneumonectomia/instrumentação , Estudos Prospectivos , Enfisema Pulmonar/terapia
19.
Lancet Respir Med ; 9(5): 457-466, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33524320

RESUMO

BACKGROUND: Bronchial thermoplasty is an endoscopic treatment for uncontrolled asthma. Previous randomised clinical trials have shown that bronchial thermoplasty reduces severe exacerbations in people with asthma. However, the long-term efficacy and safety of bronchial thermoplasty beyond 5 years is unknown. The BT10+ study aimed to investigate the efficacy and safety of bronchial thermoplasty after 10 or more years of follow-up. METHODS: BT10+ was an international, multicentre, follow-up study of participants who were previously enrolled in the AIR, RISA, and AIR2 trials and who had 10 or more years of follow-up since bronchial thermoplasty treatment. Data on patient demographics, quality of life, lung function, CT scans (AIR2 participants only), severe exacerbations, and health-care use during the previous year were collected at the BT10+ 10-year outcomes study visit. The primary effectiveness endpoint was durability of the thermoplasty treatment effect, determined by comparing the proportion of participants who had severe exacerbations during the first and fifth years after bronchial thermoplasty treatment with the proportion of participants who had severe exacerbations during the 12-month period before the BT10+ visit. The primary safety endpoint was the absence of clinically significant post-treatment respiratory image changes after bronchial thermoplasty, defined as bronchiectasis or bronchial stenosis as confirmed by pulmonary volumetric high-resolution CT scan at the BT10+ visit (AIR2 participants only). All analyses were done on an intention-to-treat basis. The trial is registered with ClinicalTrials.gov, NCT03243292. The last patient was enrolled on Dec 11, 2018. The last patient completed follow-up on Jan 10, 2019. FINDINGS: The BT10+ study enrolled 192 (45%) of the 429 participants who were enrolled in the AIR, RISA, and AIR2 trials. The BT10+ participants comprised 136 who received bronchial thermoplasty (52% of the 260 participants who received bronchial thermoplasty in the original trials), and 56 sham or control participants (33% of 169 from the original trials). 18 (32%) sham or control participants received bronchial thermoplasty after the previous trials concluded. The participants included in BT10+ were followed for 10·8-15·6 years (median 12·1 years) post-treatment. Baseline characteristics were similar between participants enrolled in BT10+ and those not enrolled. Participants treated with bronchial thermoplasty had similar proportions of severe exacerbations at the BT10+ visit (34 [25%] of 136 participants) compared with 1 year (33 [24%] of 135 participants; difference 0·6%, 95% CI -9·7 to 10·8) and 5 years (28 [22%] of 130 participants; difference 3·5%, -6·7% to 13·6) after treatment. Quality of life measurements and spirometry were similar between year 1, year 5, and the BT10+ visit. At the BT10+ study visit, pulmonary high-resolution CT scans from AIR2 participants treated with bronchial thermoplasty showed that 13 (13%) of 97 participants had bronchiectasis. When compared with baseline high-resolution CT scans, six (7%) of 89 participants treated with bronchial thermoplasty who did not have bronchiectasis at baseline had developed bronchiectasis after treatment (5 classified as mild, 1 classified as moderate). Participants treated with bronchial thermoplasty after the original study and participants in the sham or control group also had reductions in severe exacerbations at the BT10+ visit compared with baseline. INTERPRETATION: Our findings suggest that efficacy of bronchial thermoplasty is sustained for 10 years or more, with an acceptable safety profile. Therefore, bronchial thermoplasty is a long-acting therapeutic option for patients with asthma that remains uncontrolled despite optimised medical treatment. FUNDING: Boston Scientific.


Assuntos
Asma , Termoplastia Brônquica , Pulmão , Qualidade de Vida , Asma/fisiopatologia , Asma/psicologia , Asma/terapia , Termoplastia Brônquica/efeitos adversos , Termoplastia Brônquica/métodos , Broncoscopia/métodos , Demografia/estatística & dados numéricos , Progressão da Doença , Feminino , Seguimentos , Humanos , Pulmão/diagnóstico por imagem , Pulmão/fisiopatologia , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória/métodos , Exacerbação dos Sintomas , Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA