Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Circ Cardiovasc Imaging ; 17(5): e015996, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38771906

RESUMO

BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.


Assuntos
Neuropatias Amiloides Familiares , Estenose da Valva Aórtica , Angiografia por Tomografia Computadorizada , Fibrose , Miocárdio , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Masculino , Feminino , Idoso , Estudos Prospectivos , Angiografia por Tomografia Computadorizada/métodos , Idoso de 80 Anos ou mais , Miocárdio/patologia , Neuropatias Amiloides Familiares/diagnóstico por imagem , Neuropatias Amiloides Familiares/complicações , Neuropatias Amiloides Familiares/mortalidade , Valor Preditivo dos Testes , Prognóstico , Angiografia Coronária/métodos , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/fisiopatologia , Pessoa de Meia-Idade
2.
Eur Radiol Exp ; 7(1): 4, 2023 01 30.
Artigo em Inglês | MEDLINE | ID: mdl-36717474

RESUMO

BACKGROUND: To evaluate the feasibility of a novel approach for predicting hepatocellular carcinoma (HCC) response to drug-eluting beads transarterial chemoembolization (DEB-TACE) using computed tomography hepatic arteriography enhancement mapping (CTHA-EM) method. METHODS: This three-institution retrospective study included 29 patients with 46 HCCs treated with DEB-TACE between 2017 and 2020. Pre- and posttreatment CTHA-EM images were generated using a prototype deformable registration and subtraction software. Relative tumor enhancement (TPost/pre-RE) defined as the ratio of tumor enhancement to normal liver tissue was calculated to categorize tumor response as residual (TPost-RE > 1) versus non-residual (TPost-RE ≤ 1) enhancement, which was blinded compared to the response assessment on first follow-up imaging using modified RECIST criteria. Additionally, for tumors with residual enhancement, CTHA-EM was evaluated to identify its potential feeding arteries. RESULTS: CTHA-EM showed residual enhancement in 18/46 (39.1%) and non-residual enhancement in 28/46 (60.9%) HCCs, with significant differences on TPost-RE (3.05 ± 2.4 versus 0.48 ± 0.23, respectively; p < 0.001). The first follow-up imaging showed non-complete response (partial response or stable disease) in 19/46 (41.3%) and complete response in 27/46 (58.7%) HCCs. CTHA-EM had a response prediction sensitivity of 94.7% (95% CI, 74.0-99.9) and specificity of 100% (95% CI, 87.2-100). Feeding arteries to the residual enhancement areas were demonstrated in all 18 HCCs (20 arteries where DEB-TACE was delivered, 2 newly developed collaterals following DEB-TACE). CONCLUSION: CTHA-EM method was highly accurate in predicting initial HCC response to DEB-TACE and identifying feeding arteries to the areas of residual arterial enhancement.


Assuntos
Carcinoma Hepatocelular , Quimioembolização Terapêutica , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/terapia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/terapia , Estudos Retrospectivos , Resultado do Tratamento , Quimioembolização Terapêutica/métodos , Tomografia Computadorizada por Raios X/métodos , Angiografia
3.
JACC Cardiovasc Imaging ; 15(1): 75-87, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34538630

RESUMO

OBJECTIVES: In this international, multicenter study, using third-generation dual-source computed tomography (CT), we investigated the diagnostic performance of dynamic stress CT myocardial perfusion imaging (CT-MPI) in addition to coronary CT angiography (CTA) compared to invasive coronary angiography (ICA) and invasive fractional flow reserve (FFR). BACKGROUND: CT-MPI combined with coronary CTA integrates coronary artery anatomy with inducible myocardial ischemia, showing promising results for the diagnosis of hemodynamically significant coronary artery disease in single-center studies. METHODS: At 9 centers in Europe, Japan, and the United States, 132 patients scheduled for ICA were enrolled; 114 patients successfully completed coronary CTA, adenosine-stress dynamic CT-MPI, and ICA. Invasive FFR was performed in vessels with 25% to 90% stenosis. Data were analyzed by independent core laboratories. For the primary analysis, for each coronary artery the presence of hemodynamically significant obstruction was interpreted by coronary CTA with CT-MPI compared to coronary CTA alone, using an FFR of ≤0.80 and angiographic severity as reference. Territorial absolute myocardial blood flow (MBF) and relative MBF were compared using C-statistics. RESULTS: ICA and FFR identified hemodynamically significant stenoses in 74 of 289 coronary vessels (26%). Coronary CTA with ≥50% stenosis demonstrated a per-vessel sensitivity, specificity, and accuracy for the detection of hemodynamically significant stenosis of 96% (95% CI: 91%-100%), 72% (95% CI: 66%-78%), and 78% (95% CI: 73%-83%), respectively. Coronary CTA with CT-MPI showed a lower sensitivity (84%; 95% CI: 75%-92%) but higher specificity (89%; 95% CI: 85%-93%) and accuracy (88%; 95% CI: 84%-92%). The areas under the receiver-operating characteristic curve of absolute MBF and relative MBF were 0.79 (95% CI: 0.71-0.86) and 0.82 (95% CI: 0.74-0.88), respectively. The median dose-length product of CT-MPI and coronary CTA were 313 mGy·cm and 138 mGy·cm, respectively. CONCLUSIONS: Dynamic CT-MPI offers incremental diagnostic value over coronary CTA alone for the identification of hemodynamically significant coronary artery disease. Generalized results from this multicenter study encourage broader consideration of dynamic CT-MPI in clinical practice. (Dynamic Stress Perfusion CT for Detection of Inducible Myocardial Ischemia [SPECIFIC]; NCT02810795).


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Reserva Fracionada de Fluxo Miocárdico , Imagem de Perfusão do Miocárdio , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Perfusão , Valor Preditivo dos Testes , Tomografia Computadorizada por Raios X/métodos
4.
Invest Radiol ; 56(3): 188-196, 2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-32932379

RESUMO

OBJECTIVES: The aim of this study was to evaluate the ability of fusion of pretreatment magnetic resonance (MR) imaging with posttreatment perfusion-CT (P-CT) after radiofrequency ablation (RFA) of hepatocellular carcinomas (HCCs) and to determine treatment success in an objective, quantitative way. MATERIALS AND METHODS: In this institutional review board-approved study, 39 patients (78.4% male; mean age 68.2 ± 8.5 years) with a total of 43 HCCs, who underwent RFA at our institution and had diagnostic pre-RFA MR imaging and post-RFA P-CT, were included in the study. Post-RFA P-CT was performed within 24 hours after RFA. In a first step, the pre-RFA MR imaging, depicting the HCC, was registered onto the post-RFA P-CT using nonrigid image registration. After image registration, the MR data were reloaded jointly with the calculated perfusion parameter volumes into the perfusion application for quantitative analysis. A 3-dimensional volume of interest was drawn around the HCC and the ablation zone; both outlines were automatically projected onto all perfusion maps. Resulting perfusion values (normalized peak enhancement [NPE, %]; arterial liver perfusion [ALP, in mL/min/100 mL]; BF [blood flow, mL/100 mL/min]; and blood volume [BV, mL/100 mL]) and histogram data were recorded. Local tumor recurrence was defined in follow-up imaging according to the EASL guidelines. RESULTS: Image registration of MR imaging and CT data was successful in 37 patients (94.9%). Local tumor recurrence was observed in 5 HCCs (12%). In the local tumor recurrence group (LTR-group), HCC size was significantly larger (22.7 ± 3.9 cm vs 17.8 ± 5.3 cm, P = 0.035) and the ablation zone was significantly smaller (29.8 ± 6.9 cm vs 39.3 ± 6.8 cm, P = 0.014) compared with the no-local tumor recurrence group (no-LTR group). The differences (ablation zone - tumor) of the perfusion parameters NPE, ALP, BF, and BV significantly differed between the 2 groups (all P's < 0.005). Especially, the difference (ablation zone - tumor) of NPE and ALP, with a cutoff value of zero, accurately differentiated between LTR or no-LTR in all cases. A negative difference of these perfusion parameters identified local tumor recurrence in all cases. CONCLUSIONS: Image registration of pre-RFA MR imaging onto post-RFA P-CT is feasible and allows to predict local tumor recurrence within 24 hours after RFA in an objective, quantitative manner and with excellent accuracy.


Assuntos
Carcinoma Hepatocelular , Ablação por Cateter , Neoplasias Hepáticas , Ablação por Radiofrequência , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Perfusão , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento
5.
JACC Cardiovasc Imaging ; 13(10): 2177-2189, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32771574

RESUMO

OBJECTIVES: The purpose of this study was to validate computed tomography measured ECV (ECVCT) as part of routine evaluation for the detection of cardiac amyloid in patients with aortic stenosis (AS)-amyloid. BACKGROUND: AS-amyloid affects 1 in 7 elderly patients referred for transcatheter aortic valve replacement (TAVR). Bone scintigraphy with exclusion of a plasma cell dyscrasia can diagnose transthyretin-related cardiac amyloid noninvasively, for which novel treatments are emerging. Amyloid interstitial expansion increases the myocardial extracellular volume (ECV). METHODS: Patients with severe AS underwent bone scintigraphy (Perugini grade 0, negative; Perugini grades 1 to 3, increasingly positive) and routine TAVR evaluation CT imaging with ECVCT using 3- and 5-min post-contrast acquisitions. Twenty non-AS control patients also had ECVCT performed using the 5-min post-contrast acquisition. RESULTS: A total of 109 patients (43% male; mean age 86 ± 5 years) with severe AS and 20 control subjects were recruited. Sixteen (15%) had AS-amyloid on bone scintigraphy (grade 1, n = 5; grade 2, n = 11). ECVCT was 32 ± 3%, 34 ± 4%, and 43 ± 6% in Perugini grades 0, 1, and 2, respectively (p < 0.001 for trend) with control subjects lower than lone AS (28 ± 2%; p < 0.001). ECVCT accuracy for AS-amyloid detection versus lone AS was 0.87 (0.95 for 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid Perugini grade 2 only), outperforming conventional electrocardiogram and echocardiography parameters. One composite parameter, the voltage/mass ratio, had utility (similar AUC of 0.87 for any cardiac amyloid detection), although in one-third of patients, this could not be calculated due to bundle branch block or ventricular paced rhythm. CONCLUSIONS: ECVCT during routine CT TAVR evaluation can reliably detect AS-amyloid, and the measured ECVCT tracks the degree of infiltration. Another measure of interstitial expansion, the voltage/mass ratio, also performed well.


Assuntos
Amiloidose , Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Volume Sistólico , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Função Ventricular Esquerda
6.
JACC Cardiovasc Imaging ; 13(6): 1353-1363, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32498921

RESUMO

OBJECTIVES: To assess whether single-photon emission computed tomography (SPECT/CT) quantification of bone scintigraphy would improve diagnostic accuracy and offer a means of quantifying amyloid burden. BACKGROUND: Transthyretin-related cardiac amyloidosis is common and can be diagnosed noninvasively using bone scintigraphy; interpretation, however, relies on planar images. SPECT/CT imaging offers 3-dimensional visualization. METHODS: This was a single-center, retrospective analysis of 99mTc-3,3-diphosphono-1,2-propanodicarboxylic acid (DPD) scans reported using the Perugini grading system (0 = negative; 1 to 3 = increasingly positive). Conventional planar quantification techniques (heart/contralateral lung, and heart/whole-body retention ratios) were performed. Heart, adjacent vertebra, paraspinal muscle and liver peak standardized uptake values (SUVpeak) were recorded from SPECT/CT acquisitions. An SUV retention index was also calculated: (cardiac SUVpeak/vertebral SUVpeak) × paraspinal muscle SUVpeak. In a subgroup of patients, SPECT/CT quantification was compared with myocardial extracellular volume quantification by CT imaging (ECVCT). RESULTS: A total of 100 DPD scans were analyzed (patient age 84 ± 9 years; 52% male): 40 were Perugini grade 0, 12 were grade 1, 41 were grade 2, and 7 were grade 3. Cardiac SUVpeak increased from grade 0 to grade 2; however, it plateaued between grades 2 and 3 (p < 0.001). Paraspinal muscle SUVpeak increased with grade (p < 0.001), whereas vertebral SUVpeak decreased (p < 0.001). The composite parameter of SUV retention index overcame the plateauing of the cardiac SUVpeak and increased across all grades (p < 0.001). Cardiac SUVpeak correlated well (r2 = 0.73; p < 0.001) with ECVCT. Both the cardiac SUVpeak and SUV retention index had excellent diagnostic accuracy (area under the curve [AUC]: 0.999). The heart to contralateral lung ratio performed the best of the planar quantification techniques (AUC: 0.987). CONCLUSIONS: SPECT/CT quantification in DPD scintigraphy is possible and outperforms planar quantification techniques. Differentiation of Perugini grade 2 or 3 is confounded by soft tissue uptake, which can be overcome by a composite SUV retention index. This index can help in the diagnosis of cardiac amyloidosis and may offer a means of monitoring response to therapy.


Assuntos
Neuropatias Amiloides Familiares/diagnóstico por imagem , Cardiomiopatias/diagnóstico por imagem , Difosfonatos/administração & dosagem , Compostos de Organotecnécio/administração & dosagem , Compostos Radiofarmacêuticos/administração & dosagem , Tomografia Computadorizada com Tomografia Computadorizada de Emissão de Fóton Único , Idoso , Idoso de 80 Anos ou mais , Osso e Ossos/diagnóstico por imagem , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Estudos Retrospectivos , Índice de Gravidade de Doença , Imagem Corporal Total
7.
J Neurointerv Surg ; 12(10): 1028-1032, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32424007

RESUMO

BACKGROUND: To compare the computed tomography perfusion (CTP) outcomes derived from two commercial CTP processing software and evaluate their concordance in terms of eligibility for mechanical thrombectomy (MT) in acute ischemic stroke (AIS), based on DEFUSE III criteria. METHODS: A total of 118 patients (62 patients in the MT group and 56 patients in the non-MT (NMT) group) were included. Volumetric perfusion outputs were compared between Syngo.via (package A) and RAPID (package B). Influence on proceeding or not-proceeding with MT was based on DEFUSE III imaging eligibility criteria. RESULTS: Median core infarct/hypoperfusion volumes were 12.3/126 mL in the MT group and 7.7/29.3 ml in the NMT group with package A and 10.5/138 mL and 1.9/24.5 mL with package B, respectively. In the MT group (n=62), concordant perfusion results in terms of patient triage were noted in all but two cases. Of these, one patient would not have qualified (low ASPECTS), while the other qualified based on package A results. For the NMT group (n=56), there was discordance in terms of MT eligibility in seven cases. However, none of these patients qualified for MT based on DEFUSE III criteria. CONCLUSIONS: Both perfusion softwares showed high concordance in correctly triaging patients in the MT versus NMT groups (110/118, 93.2%), which further improved when all DEFUSE III imaging criteria were considered (117/118, 99.1%). The core/hypoperfusion volumes in the NMT group and core infarct volumes in the MT groups were comparable. The hypoperfusion volumes in the MT group varied slightly but did not affect triage between groups.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Tomada de Decisão Clínica/métodos , Imagem de Perfusão/métodos , Software , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Isquemia Encefálica/terapia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/tendências , Estudos Prospectivos , Estudos Retrospectivos , Software/tendências , Acidente Vascular Cerebral/terapia , Trombectomia/métodos , Trombectomia/tendências , Tomografia Computadorizada por Raios X/tendências , Triagem/métodos , Triagem/tendências
8.
Invest Radiol ; 54(10): 661-668, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31211710

RESUMO

OBJECTIVES: The aim of this study was to evaluate the feasibility of a computed tomography (CT) protocol enabling the visualization of the prostatic artery (PA) before prostatic artery embolization (PAE) in benign prostatic hyperplasia, which provides quantitative perfusion information of the prostate gland. MATERIALS AND METHODS: In this institutional review board-approved study, 22 consecutive patients (mean age, 67 ± 7 years) who were planned to undergo PAE underwent a dynamic CT scan of the pelvis (scan range, 22.4 cm; cycle time, 1.5 seconds; scan time, 44 seconds; 25 scan cycles; 70 kVp; 100 mAs) after the administration of 70 mL of iodinated contrast media (flow rate, 6 mL/s; 10 seconds' delay). Image postprocessing consisted of a spatiotemporal, frequency-depending multiband filtering technique with noise reduction, motion correction, resulting in (1) time-resolved, temporal maximum intensity projection (MIP) images from fusion of multiple arterial time points; (2) 4-dimensional (4D) CT angiography images after bone and calcium plaque removal; and (3) parametric perfusion maps of the prostate. Intraprocedural cone-beam CT was performed with a microcatheter in the PA. In both modalities, the contrast-to-noise ratio of the right internal iliac artery or the PA was calculated, respectively. Visibility of the PA was scored using a Likert scale (score 1 = not seen, to score 4 = intraprostatic PA branches seen). Quantitative perfusion analysis of the dynamic pelvic CT included calculation of the blood flow, blood volume, mean transit time, and flow extraction product. RESULTS: The average volume CT dose index and dose length product of CT was 35.7 ± 6.8 mGy and 737.4 ± 146.3 mGy·cm, respectively. Contrast-to-noise ratio of the pelvic vessels on temporal MIP images and cone-beam CT were 45 ± 19 and 69 ± 27, respectively (P < 0.01). The mean visibility score of the PA was 3.6 ± 0.6 for 4D-CT angiography and 3.97 ± 0.2 for cone-beam CT (P < 0.001). The PA was visualized in 100% of 4D-CT angiography examinations, with one PA being visible only proximally. Prostate CT perfusion analysis showed blood flow, blood volume, mean transit time, and flow extraction product values of 27.9 ± 12.5 mL/100 mL/min, 2.0 ± 0.8 mL/100 mL, 4.5 ± 0.5 second, and 12.6 ± 5.4 mL/100 mL/min, respectively, for the whole prostate gland. About half the patients showed a pronounced difference between the lobes. CONCLUSIONS: We introduced a CT protocol for PAE planning providing excellent visualization of the PA on temporal MIP images and 4D-CT angiography at a reasonable dose and low contrast volume. In addition, quantitative perfusion information is available, which might be useful for outcome prediction after embolization.


Assuntos
Embolização Terapêutica/métodos , Tomografia Computadorizada Quadridimensional/métodos , Hiperplasia Prostática/diagnóstico por imagem , Hiperplasia Prostática/terapia , Idoso , Estudos de Viabilidade , Humanos , Masculino , Imagem de Perfusão , Próstata/irrigação sanguínea , Próstata/diagnóstico por imagem
9.
J Neurointerv Surg ; 11(12): 1257-1260, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31118267

RESUMO

BACKGROUND: The role of mechanical thrombectomy in acute ischemic stroke (AIS) has been further expanded by recent trials which relied on the results of CT perfusion (CTP) imaging. However, CTP parameters for ischemia and infarct can vary significantly across different vendors. METHODS: We compared the outcomes of the Siemens CTP software against the clinically validated RAPID software in 45 consecutive patients with suspected AIS. Both perfusion softwares initially processed images using vendor defined parameters for hypoperfusion and non-viable tissue. The software thresholds on the Siemens software were decrementally altered to see if concordant results between softwares could be attained. RESULTS: At baseline settings, the mean values for core infarct and hypoperfusion were different (mean of 30/69 mL, respectively, for RAPID and 49/77 mL for Siemens). However, reducing the threshold values for the later software showed a concordance of values at a relative cerebral blood flow <20%, with resulting core infarct and hypoperfusion volumes at 31/69 mL, respectively, for the Siemens software. A Wilcoxon paired test showed no significant difference between the calculated core infarct and hypoperfusion values, both for the entire population as well as for the subgroup of patients with large vessel occlusion. CONCLUSION: Equivalent CTP results between vendor softwares may be attainable by altering the thresholds for hypoperfused and non-viable tissue, despite differences in acquisition techniques, post-processing, and scanners.


Assuntos
Isquemia Encefálica/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/normas , Imagem de Perfusão/normas , Software/normas , Acidente Vascular Cerebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Isquemia Encefálica/fisiopatologia , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Estudos Retrospectivos , Acidente Vascular Cerebral/fisiopatologia , Tomografia Computadorizada por Raios X/métodos
10.
Korean J Radiol ; 19(6): 1053-1065, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30386137

RESUMO

Objective: To evaluate the clinical impact of using registration software for ablative margin assessment on pre-radiofrequency ablation (RFA) magnetic resonance imaging (MRI) and post-RFA computed tomography (CT) compared with the conventional side-by-side MR-CT visual comparison. Materials and Methods: In this Institutional Review Board-approved prospective study, 68 patients with 88 hepatocellulcar carcinomas (HCCs) who had undergone pre-RFA MRI were enrolled. Informed consent was obtained from all patients. Pre-RFA MRI and post-RFA CT images were analyzed to evaluate the presence of a sufficient safety margin (≥ 3 mm) in two separate sessions using either side-by-side visual comparison or non-rigid registration software. Patients with an insufficient ablative margin on either one or both methods underwent additional treatment depending on the technical feasibility and patient's condition. Then, ablative margins were re-assessed using both methods. Local tumor progression (LTP) rates were compared between the sufficient and insufficient margin groups in each method. Results: The two methods showed 14.8% (13/88) discordance in estimating sufficient ablative margins. On registration software-assisted inspection, patients with insufficient ablative margins showed a significantly higher 5-year LTP rate than those with sufficient ablative margins (66.7% vs. 27.0%, p = 0.004). However, classification by visual inspection alone did not reveal a significant difference in 5-year LTP between the two groups (28.6% vs. 30.5%, p = 0.79). Conclusion: Registration software provided better ablative margin assessment than did visual inspection in patients with HCCs who had undergone pre-RFA MRI and post-RFA CT for prediction of LTP after RFA and may provide more precise risk stratification of those who are treated with RFA.


Assuntos
Carcinoma Hepatocelular/cirurgia , Neoplasias Hepáticas/cirurgia , Imageamento por Ressonância Magnética , Ablação por Radiofrequência , Tomografia Computadorizada por Raios X , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Progressão da Doença , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Razão de Chances , Estudos Prospectivos , Software , Resultado do Tratamento
11.
Circ Cardiovasc Imaging ; 10(4)2017 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28389506

RESUMO

BACKGROUND: The clinical analysis of myocardial dynamic computed tomography myocardial perfusion imaging lacks standardization. The objective of this prospective study was to compare different analysis approaches to diagnose ischemia in patients with stable angina referred for invasive coronary angiography. METHODS AND RESULTS: Patients referred for evaluation of stable angina symptoms underwent adenosine-stress dynamic computed tomography myocardial perfusion imaging with a second-generation dual-source scanner. Quantitative perfusion parameters, such as blood flow, were calculated by parametric deconvolution for each myocardial voxel. Initially, perfusion parameters were extracted according to standard 17-segment model of the left ventricle (fully automatic analysis). These were then manually sampled by an operator (semiautomatic analysis). Areas under the receiver-operating characteristic curves of the 2 different approaches were compared. Invasive fractional flow reserve ≤0.80 or diameter stenosis ≥80% on quantitative coronary angiography was used as reference standard to define ischemia. We enrolled 115 patients (88 men; age 57±9 years). There were 72 of 286 (25%) vessels causing ischemia in 52 of 115 (45%) patients. The semiautomatic analysis method was better than the fully automatic method at predicting ischemia (areas under the receiver-operating characteristic curves, 0.87 versus 0.69; P<0.001) with readings obtained in the endocardial myocardium performing better than those in the epicardial myocardium (areas under the receiver-operating characteristic curves, 0.87 versus 0.72; P<0.001). The difference in performance between blood flow, expressed as relative to remote myocardium, and absolute blood flow was not statistically significant (areas under the receiver-operating characteristic curves, 0.90 versus 0.87; P=ns). CONCLUSIONS: Endocardial perfusion parameters obtained by semiautomatic analysis of dynamic computed tomography myocardial perfusion imaging may permit robust discrimination between coronary vessels causing ischemia versus not causing ischemia.


Assuntos
Angina Estável/diagnóstico por imagem , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Circulação Coronária , Vasos Coronários/diagnóstico por imagem , Imagem de Perfusão do Miocárdio/métodos , Adenosina/administração & dosagem , Idoso , Angina Estável/fisiopatologia , Área Sob a Curva , Automação , Doença da Artéria Coronariana/fisiopatologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Variações Dependentes do Observador , Valor Preditivo dos Testes , Estudos Prospectivos , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Vasodilatadores/administração & dosagem
12.
Cardiovasc Intervent Radiol ; 40(6): 873-883, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28091728

RESUMO

PURPOSE: To evaluate the value of pre-radiofrequency ablation (RFA) MR and post-RFA CT registration for the assessment of the therapeutic response of hepatocellular carcinoma (HCC). MATERIALS AND METHODS: A total of 178 patients with single HCC who received RFA as an initial treatment and had available pre-RFA MR and post-RFA CT images were included in this retrospective study. Two independent readers (one experienced radiologist, one inexperienced radiologist) scored the ablative margin (AM) of treated tumors on a four-point scale (1, residual tumor; 2, incomplete AM; 3, borderline AM; 4, sufficient AM), in two separate sessions: (1) visual comparison between pre-and post-RFA images; (2) with addition of nonrigid registration for pre- and post-RFA images. Local tumor progression (LTP) rates between low-risk (response score, 3-4) and high-risk groups (1-2) were analyzed using the Kaplan-Meier method at each interpretation session. RESULTS: The patients' reassignments after using the registered images were statistically significant for inexperienced reader (p < 0.001). In the inexperienced reader, LTP rates of low- and high-risk groups were significantly different with addition of registered images (session 2) (p < 0.001), but not significantly different in session 1 (p = 0.101). However, in the experienced reader, LTP rates of low- and high-risk groups were significantly different in both interpretation sessions (p < 0.001). Using the registered images, the cumulative incidence of LTP at 2 years was 3.0-6.6%, for the low-risk group, and 18.6-27.8% for the high-risk group. CONCLUSION: Registration between pre-RFA MR and post-RFA CT images may allow better assessment of the therapeutic response of HCC after RFA, especially for inexperienced radiologists, helping in the risk stratification for LTP.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter/métodos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Idoso , Competência Clínica , Feminino , Humanos , Fígado/diagnóstico por imagem , Fígado/cirurgia , Imageamento por Ressonância Magnética/métodos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Variações Dependentes do Observador , Cuidados Paliativos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Resultado do Tratamento
13.
Eur Radiol ; 27(3): 1074-1080, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27368924

RESUMO

OBJECTIVES: To determine perfusion computed tomography (P-CT) findings for distinction of arterial pseudolesions (APL) from hepatocellular carcinoma (HCC) in the cirrhotic liver. METHODS: 32 APL and 21 HCC in 20 cirrhotic patients (15 men; 65 ± 10 years), who underwent P-CT for evaluation of HCC pre- (N = 9) or post- (N = 11) transarterial chemoembolization, were retrospectively included using CT follow-up as the standard of reference. All 53 lesions were qualitatively (visual) and quantitatively (perfusion parameters) analysed according to their shape (wedge, irregular, nodular), location (not-/adjunct to a fistula), arterial liver perfusion (ALP), portal venous liver perfusion (PLP), hepatic perfusion index (HPI). Accuracy for diagnosis of HCC was determined using receiver operating characteristics. RESULTS: 18/32 (56 %) APL were wedge shaped, 10/32 (31 %) irregular and 4/32 (12 %) nodular, while 11/21 (52 %) HCC were nodular or 10/21 (48 %) irregular, but never wedge shaped. Significant difference between APL and HCC was seen for lesion shape in pretreated lesions (P < 0.001), and for PLP and HPI in both pre- and post-treated lesions (all, P < 0.001). Diagnostic accuracy for HCC was best for combined assessment of lesion configuration and PLP showing an area under the curve of 0.901. CONCLUSION: Combined assessment of lesion configuration and portal venous perfusion derived from P-CT allows best to discriminate APL from HCC with high diagnostic accuracy. KEY POINTS: • Arterio-portal shunting is common in the cirrhotic liver, especially after local treatment. • Arterial pseudolesions (APL) due to shunting might mimic hepatocellular carcinoma (HCC). • Perfusion-CT allows for qualitative and quantitative assessment of liver lesions. • Lesion configuration fails to discriminate APL from HCC in locally treated patients. • Integration of quantitative perfusion analysis improves accuracy for diagnosis of HCC.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Veia Porta/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
14.
Radiology ; 280(1): 78-87, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26824712

RESUMO

Purpose To develop a dual-energy contrast media-enhanced computed tomographic (CT) protocol by using time-attenuation curves from previously acquired perfusion CT data and to evaluate prospectively the relationship between iodine enhancement metrics at dual-energy CT and perfusion CT parameters in patients with hepatocellular carcinoma (HCC). Materials and Methods Institutional review board and local ethics committee approval and written informed consent were obtained. The retrospective part of this study included the development of a dual-energy CT contrast-enhanced protocol to evaluate peak arterial enhancement of HCC in the liver on the basis of time-attenuation curves from previously acquired perfusion CT data in 20 patients. The prospective part of the study consisted of an intraindividual comparison of dual-energy CT and perfusion CT data in another 20 consecutive patients with HCC. Iodine density and iodine ratio (iodine attenuation of the lesion divided by iodine attenuation in the aorta) from dual-energy CT and arterial perfusion (AP), portal venous perfusion, and total perfusion (TP) from perfusion CT were compared. Pearson R and linear correlation coefficients were calculated for AP and iodine density, AP and iodine ratio, TP and iodine density, and TP and iodine ratio. Results The dual-energy CT protocol consisted of bolus tracking in the abdominal aorta (threshold, 150 HU; scan delay, 9 seconds). The strongest intraindividual correlations in HCCs were found between iodine density and AP (r = 0.75, P = .0001). Moderate correlations were found between iodine ratio and AP (r = 0.50, P = .023) and between iodine density and TP (r = 0.56, P = .011). No further significant correlations were found. The volume CT dose index (11.4 mGy) and dose-length product (228.0 mGy · cm) of dual-energy CT was lower than those of the arterial phase of perfusion CT (36.1 mGy and 682.3 mGy · cm, respectively). Conclusion A contrast-enhanced dual-energy CT protocol developed by using time-attenuation curves from previously acquired perfusion CT data sets in patients with HCC could show good correlation between iodine density from dual-energy CT with AP from perfusion CT. (©) RSNA, 2016.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Idoso de 80 Anos ou mais , Meios de Contraste , Feminino , Humanos , Fígado/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Estudos Retrospectivos
15.
Invest Radiol ; 51(7): 430-4, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26756941

RESUMO

OBJECTIVE: The aim of this study was to investigate the feasibility of multiphasic dynamic computed tomography (CT) scans in providing liver tissue perfusion characteristics using the dual maximum slope model in patients with liver cirrhosis and hepatocellular carcinoma (HCC). MATERIALS AND METHODS: With institutional review board approval and acquisition of informed consent, we retrospectively analyzed the prospectively collected perfusion CT (PCT) data of 36 patients enrolled in a prospective clinical trial for pretherapeutic assessment of HCC. To obtain perfusion parameters including arterial liver perfusion (ALP), portal venous perfusion (PVP), and the hepatic perfusion index (HPI), 5-phase dynamic CT data sets with triple arterial phases including peak aortic and splenic enhancement information were selected from the PCT data sets. The PCT and 5-phase dynamic CT data sets extracted from the PCT data were analyzed using dedicated perfusion software based on the dual maximum slope model. Comparisons between the perfusion parameters of each method were performed using Wilcoxon signed rank test and intraclass correlation coefficients. RESULTS: The extraction of liver perfusion parameters from 5-phase dynamic CT scans was feasible using the dual maximum slope model, and no significant differences were observed between perfusion parameters obtained from 5-phase dynamic CT and from PCT in the liver parenchyma (ALP, P = 0.137; PVP, P = 0.110; HPI, P = 0.793) and in HCCs (ALP, P = 0.162; HPI, P = 0.131). Regarding intraclass correlation coefficients, excellent agreement was observed between perfusion parameters obtained using 5-phase dynamic CT and from PCT in both the liver parenchyma (ALP, 0.793; PVP, 0.831; HPI, 0.934) and in HCCs (ALP, 0.889; HPI, 0.943). CONCLUSIONS: The extraction of liver perfusion parameters from 5-phase dynamic CT scans was feasible using the dual maximum slope model and provided comparable values to those obtained from PCT.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Cirrose Hepática/diagnóstico por imagem , Neoplasias Hepáticas/diagnóstico por imagem , Tomografia Computadorizada Multidetectores/métodos , Adulto , Idoso , Carcinoma Hepatocelular/fisiopatologia , Meios de Contraste , Estudos de Viabilidade , Feminino , Humanos , Fígado/irrigação sanguínea , Fígado/diagnóstico por imagem , Fígado/fisiopatologia , Cirrose Hepática/fisiopatologia , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas/fisiopatologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Intensificação de Imagem Radiográfica/métodos , Fluxo Sanguíneo Regional/fisiologia , Estudos Retrospectivos , Adulto Jovem
16.
Eur J Radiol ; 84(12): 2359-67, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26137905

RESUMO

The aim of this review article is to define the technical prerequisites of modern state-of-the-art CT perfusion imaging in oncology at reasonable dose levels. The focus is mainly on abdominal and thoracic tumor imaging, as they pose the largest challenges with respect to attenuation and patient motion. We will show that low kV dynamic scanning in conjunction with detection technology optimized for low photon fluxes has the highest impact on reducing dose independently of other choices made in the protocol selection. We discuss, derived from relatively simple first principles, on what appropriate temporal sampling and total scan duration depend on and why optimized contrast medium injection protocols are also essential in limiting dose. Finally we will examine the possibility of simultaneously extracting standard morphological and functional information from one single 4D examination as a potential enabler for a more widespread use of dynamic contrast enhanced CT in oncology.


Assuntos
Meios de Contraste , Intensificação de Imagem Radiográfica , Tomografia Computadorizada por Raios X , Humanos , Radiografia Abdominal , Radiografia Torácica
17.
AJR Am J Roentgenol ; 203(1): 70-7, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24951197

RESUMO

OBJECTIVE: The purpose of this study was to prospectively evaluate the diagnostic impact of prototypic software that allows registration of CT images before and after radiofrequency ablation (RFA) for safety margin assessment, as well as to determine the therapeutic impact of this software on local tumor progression in comparison with the conventional method of side-by-side CT comparison. SUBJECTS AND METHODS: One-hundred fifty patients with a single hepatocellular carcinoma (HCC) referred for RFA were enrolled. CT scans were obtained before and after RFA, and all CT images were analyzed with and without the use of nonrigid registration software. Thereafter, local tumor progression in the study group (n = 150) was compared with that in a matched control group (n = 90) in which side-by-side comparison of CT images before and after RFA was used for safety margin assessment. RESULTS: RFA using registration software-assisted diagnoses to decide whether additional RFA was necessary resulted in a 10.67% local tumor progression rate 42 months after the procedure, which was significantly better than that in the matched control group (23.33%) (p = 0.01). After registration software was used, 15.33% (23/150) of patients had conflicting assessments on the safety margin and the necessity for additional RFAs compared with the initial visual comparison of the CT scans. CONCLUSION: The addition of follow-up registration of CT images before and after RFA resulted in significantly improved assessment of safety margins, simplifying the decision of whether to perform additional treatments and reducing local tumor progression of HCCs after RFA.


Assuntos
Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/cirurgia , Ablação por Cateter , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/cirurgia , Tomografia Computadorizada por Raios X , Carcinoma Hepatocelular/patologia , Progressão da Doença , Feminino , Humanos , Neoplasias Hepáticas/patologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Interpretação de Imagem Radiográfica Assistida por Computador , Software , Resultado do Tratamento
18.
Eur Heart J Cardiovasc Imaging ; 15(1): 85-94, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-23935153

RESUMO

AIMS: The severity of coronary artery narrowing is a poor predictor of functional significance, in particular in intermediate coronary lesions (30-70% diameter narrowing). The aim of this work was to compare the performance of a quantitative hyperaemic myocardial blood flow (MBF) index derived from adenosine dynamic computed tomography perfusion (CTP) imaging with that of visual CT coronary angiography (CTCA) and semi-automatic quantitative CT (QCT) in the detection of functionally significant coronary lesions in patients with stable chest pain. METHODS AND RESULTS: CTCA and CTP were performed in 80 patients (210 analysable coronary vessels) referred to invasive coronary angiography (ICA). The MBF index (mL/100 mL/min) was computed using a model-based parametric deconvolution method. The diagnostic performance of the MBF index in detecting functionally significant coronary lesions was compared with visual CTCA and QCT. Coronary lesions with invasive fractional flow reserve of ≤0.75 were defined as functionally significant. The optimal cut-off value of the MBF index to detect functionally significant coronary lesions was 78 mL/100 mL/min. On a vessel-territory level, the MBF index had a larger area under the curve (0.95; 95% confidence interval [95% CI]: 0.92-0.98) compared with visual CTCA (0.85; 95% CI: 0.79-0.91) and QCT (0.89; 95% CI: 0.84-0.93) (both P-values <0.001). In the analysis restricted to intermediate coronary lesions, the specificity of visual CTCA (69%) and QCT (77%) could be improved by the subsequent use of the MBF index (89%). CONCLUSION: In this proof-of-principle study, the MBF index performed better than visual CTCA and QCT in the identification of functionally significant coronary lesions. The MBF index had additional value beyond CTCA anatomy in intermediate coronary lesions. This may have a potential to support patient management.


Assuntos
Dor no Peito/diagnóstico por imagem , Estenose Coronária/diagnóstico por imagem , Reserva Fracionada de Fluxo Miocárdico/fisiologia , Tomografia Computadorizada por Raios X/métodos , Adenosina , Velocidade do Fluxo Sanguíneo/fisiologia , Angiografia Coronária , Teste de Esforço , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Interpretação de Imagem Radiográfica Assistida por Computador , Sensibilidade e Especificidade , Software
19.
Eur J Radiol ; 82(12): e894-900, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24094644

RESUMO

OBJECTIVE: To evaluate dynamic volume perfusion CT (dVPCT) tumor baseline characteristics of three different subtypes of lung cancer in untreated patients. MATERIALS AND METHODS: 173 consecutive patients (131 men, 42 women; mean age 61 ± 10 years) with newly diagnosed lung cancer underwent dVPCT prior to biopsy. Tumor permeability, blood flow (BF), blood volume (BV) and mean transit time (MTT) were quantitatively assessed as well as tumor diameter and volume. Tumor subtypes were histologically determined and compared concerning their dVPCT results. dVPCT results were correlated to tumor diameter and volume. RESULTS: Histology revealed adenocarcinoma in 88, squamous cell carcinoma in 54 and small cell lung cancer (SCLC) in 31 patients. Tumor permeability was significantly differing between adenocarcinoma, squamous cell carcinoma and SCLC (all p<0.05). Tumor BF and BV were higher in adenocarcinomathan in SCLC (p = 0.001 and p=0.0002 respectively). BV was also higher in squamous cell carcinoma compared to SCLC (p = 0.01). MTT was not differing between tumor subtypes. Regarding all tumors, tumor diameter did not correlate with any of the dVPCT parameters, whereas tumor volume was negatively associated with permeability, BF and BV (r = -0.22, -0.24, -0.24, all p<0.05). In squamous cell carcinoma, tumor diameter und volume correlated with BV (r = 0.53 and r = -0.40, all p<0.05). In SCLC, tumor diameter und volume correlated with MTT (r = 0.46 and r = 0.39, all p<0.05). In adenocarcinoma, no association between morphological and functional tumor characteristics was observed. CONCLUSIONS: dVPCT parameters are only partially related to tumor diameter and volume and are significantly differing between lung cancer subtypes.


Assuntos
Imageamento Tridimensional/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/fisiopatologia , Imagem de Perfusão/estatística & dados numéricos , Circulação Pulmonar , Idoso , Idoso de 80 Anos ou mais , China , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Carga Tumoral
20.
Invest Radiol ; 48(11): 787-94, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-23748229

RESUMO

PURPOSE: The purpose of this study was to evaluate prospectively, in patients with liver metastases, the ability of computed tomographic (CT) perfusion to predict the morphologic response and survival after transarterial radioembolization (TARE). METHODS: Thirty-eight patients (22 men; mean [SD] age, 63 [12] years) with otherwise therapy-refractory liver metastases underwent dynamic, contrast-enhanced CT perfusion within 1 hour before treatment planning catheter angiography, for calculation of the arterial perfusion (AP) of liver metastases, 20 days before TARE with Yttrium-90 microspheres. Treatment response was evaluated morphologically on follow-up imaging (mean, 114 days) on the basis of the Response Evaluation Criteria in Solid Tumors criteria (version 1.1). Pretreatment CT perfusion was compared between responders and nonresponders. One-year survival was calculated including all 38 patients using the Kaplan-Meier curves; the Cox proportional hazard model was used for calculating predictors of survival. RESULTS: Follow-up imaging was not available in 11 patients because of rapidly deteriorating health or death. From the remaining 27, a total of 9 patients (33%) were classified as responders and 18 patients (67%) were classified as nonresponders. A significant difference in AP was found on pretreatment CT perfusion between the responders and the nonresponders to the TARE (P < 0.001). Change in tumor size on the follow-up imaging correlated significantly and negatively with AP before the TARE (r = -0.60; P = 0.001). Receiver operating characteristics analysis of AP in relation to treatment response revealed an area under the curve of 0.969 (95% confidence interval, 0.911-1.000; P < 0.001). A cutoff AP of 16 mL per 100 mL/min was associated with a sensitivity of 100% (9/9) (95% CI, 70%-100%) and a specificity of 89% (16/18) (95% CI, 62%-96%) for predicting therapy response. A significantly higher 1-year survival after the TARE was found in the patients with a pretreatment AP of 16 mL per 100 mL/min or greater (P = 0.028), being a significant, independent predictor of survival (hazard ratio, 0.101; P = 0.015). CONCLUSIONS: Arterial perfusion of liver metastases, as determined by pretreatment CT perfusion imaging, enables prediction of short-term morphologic response and 1-year survival to TARE.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/radioterapia , Neoplasias Hepáticas/secundário , Tomografia Computadorizada por Raios X/métodos , Angiografia , Artérias , Meios de Contraste , Feminino , Humanos , Iohexol/análogos & derivados , Fígado/irrigação sanguínea , Fígado/patologia , Masculino , Microesferas , Pessoa de Meia-Idade , Estudos Prospectivos , Compostos Radiofarmacêuticos/uso terapêutico , Taxa de Sobrevida , Resultado do Tratamento , Radioisótopos de Ítrio/uso terapêutico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA