Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
1.
Radiat Prot Dosimetry ; 199(14): 1465-1471, 2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37721084

RESUMO

Rapid sample processing and interpretation of estimated exposures will be critical for triaging exposed individuals after a major radiation incident. The dicentric chromosome (DC) assay assesses absorbed radiation using metaphase cells from blood. The Automated Dicentric Chromosome Identifier and Dose Estimator System (ADCI) identifies DCs and determines radiation doses. This study aimed to broaden accessibility and speed of this system, while protecting data and software integrity. ADCI Online is a secure web-streaming platform accessible worldwide from local servers. Cloud-based systems containing data and software are separated until they are linked for radiation exposure estimation. Dose estimates are identical to ADCI on dedicated computer hardware. Image processing and selection, calibration curve generation, and dose estimation of 9 test samples completed in < 2 days. ADCI Online has the capacity to alleviate analytic bottlenecks in intermediate-to-large radiation incidents. Multiple cloned software instances configured on different cloud environments accelerated dose estimation to within clinically relevant time frames.


Assuntos
Computação em Nuvem , Exposição à Radiação , Humanos , Software , Bioensaio
2.
Int J Radiat Biol ; 96(11): 1492-1503, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32910711

RESUMO

PURPOSE: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the dicentric chromosome assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole-body irradiation has significantly improved throughput without compromising accuracy, however, low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial-body exposure determination. MATERIALS AND METHODS: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration samples and those exposed to unknown radiation levels are corrected subtracting this false positive fraction from each. In partial-body exposures, the fraction of cells exposed, and radiation dose can be quantified after applying this modification of the contaminated Poisson method. RESULTS: Dose estimates of three partially irradiated samples diverged 0.2-2.5 Gy from physical doses and irradiated cell fractions deviated by 2.3%-15.8% from the known levels. Synthetic partial-body samples comprised of unirradiated and 3 Gy samples from 4 laboratories were correctly discriminated as inhomogeneous by multiple criteria. Root mean squared errors of these dose estimates ranged from 0.52 to 1.14 Gy2 and from 8.1 to 33.3%2 for the fraction of cells irradiated. CONCLUSIONS: Automated DCA can differentiate whole- from partial-body radiation exposures and provides timely quantification of estimated whole-body equivalent dose.


Assuntos
Análise Citogenética , Exposição à Radiação/análise , Radiometria/métodos , Automação , Humanos , Distribuição de Poisson
3.
PLoS One ; 15(4): e0232008, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32330192

RESUMO

BACKGROUND: Accurate radiation dose estimates are critical for determining eligibility for therapies by timely triaging of exposed individuals after large-scale radiation events. However, the universal assessment of a large population subjected to a nuclear spill incident or detonation is not feasible. Even with high-throughput dosimetry analysis, test volumes far exceed the capacities of first responders to measure radiation exposures directly, or to acquire and process samples for follow-on biodosimetry testing. AIM: To significantly reduce data acquisition and processing requirements for triaging of treatment-eligible exposures in population-scale radiation incidents. METHODS: Physical radiation plumes modelled nuclear detonation scenarios of simulated exposures at 22 US locations. Models assumed only location of the epicenter and historical, prevailing wind directions/speeds. The spatial boundaries of graduated radiation exposures were determined by targeted, multistep geostatistical analysis of small population samples. Initially, locations proximate to these sites were randomly sampled (generally 0.1% of population). Empirical Bayesian kriging established radiation dose contour levels circumscribing these sites. Densification of each plume identified critical locations for additional sampling. After repeated kriging and densification, overlapping grids between each pair of contours of successive plumes were compared based on their diagonal Bray-Curtis distances and root-mean-square deviations, which provided criteria (<10% difference) to discontinue sampling. RESULTS/CONCLUSIONS: We modeled 30 scenarios, including 22 urban/high-density and 2 rural/low-density scenarios under various weather conditions. Multiple (3-10) rounds of sampling and kriging were required for the dosimetry maps to converge, requiring between 58 and 347 samples for different scenarios. On average, 70±10% of locations where populations are expected to receive an exposure ≥2Gy were identified. Under sub-optimal sampling conditions, the number of iterations and samples were increased, and accuracy was reduced. Geostatistical mapping limits the number of required dose assessments, the time required, and radiation exposure to first responders. Geostatistical analysis will expedite triaging of acute radiation exposure in population-scale nuclear events.


Assuntos
Exposição à Radiação/análise , Radiometria/métodos , Teorema de Bayes , Humanos , Modelos Teóricos , Exposição Ocupacional/análise , Doses de Radiação , Análise Espacial , Triagem , Tempo (Meteorologia)
4.
Radiat Prot Dosimetry ; 186(1): 42-47, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-30624749

RESUMO

Accuracy of the automated dicentric chromosome (DC) assay relies on metaphase image selection. This study validates a software framework to find the best image selection models that mitigate inter-sample variability. Evaluation methods to determine model quality include the Poisson goodness-of-fit of DC distributions for each sample, residuals after calibration curve fitting and leave-one-out dose estimation errors. The process iteratively searches a pool of selection model candidates by modifying statistical and filter cut-offs to rank the best candidates according to their respective evaluation scores. Evaluation scores minimize the sum of squared errors relative to the actual radiation dose of the calibration samples. For one laboratory, the minimum score for the curve fit residual method was 0.0475 Gy2, compared to 1.1975 Gy2 without image selection. Application of optimal selection models using samples of unknown exposure produced estimated doses within 0.5 Gy of physical dose. Model optimization standardizes image selection among samples and provides relief from manual DC scoring, improving accuracy and consistency of dose estimation.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas , Cromossomos Humanos/efeitos da radiação , Análise Citogenética/métodos , Laboratórios/normas , Metáfase/genética , Radiometria/normas , Automação , Humanos , Metáfase/efeitos da radiação , Microscopia/métodos , Doses de Radiação
5.
J Vis Exp ; (127)2017 09 04.
Artigo em Inglês | MEDLINE | ID: mdl-28892030

RESUMO

Biological radiation dose can be estimated from dicentric chromosome frequencies in metaphase cells. Performing these cytogenetic dicentric chromosome assays is traditionally a manual, labor-intensive process not well suited to handle the volume of samples which may require examination in the wake of a mass casualty event. Automated Dicentric Chromosome Identifier and Dose Estimator (ADCI) software automates this process by examining sets of metaphase images using machine learning-based image processing techniques. The software selects appropriate images for analysis by removing unsuitable images, classifies each object as either a centromere-containing chromosome or non-chromosome, further distinguishes chromosomes as monocentric chromosomes (MCs) or dicentric chromosomes (DCs), determines DC frequency within a sample, and estimates biological radiation dose by comparing sample DC frequency with calibration curves computed using calibration samples. This protocol describes the usage of ADCI software. Typically, both calibration (known dose) and test (unknown dose) sets of metaphase images are imported to perform accurate dose estimation. Optimal images for analysis can be found automatically using preset image filters or can also be filtered through manual inspection. The software processes images within each sample and DC frequencies are computed at different levels of stringency for calling DCs, using a machine learning approach. Linear-quadratic calibration curves are generated based on DC frequencies in calibration samples exposed to known physical doses. Doses of test samples exposed to uncertain radiation levels are estimated from their DC frequencies using these calibration curves. Reports can be generated upon request and provide summary of results of one or more samples, of one or more calibration curves, or of dose estimation.


Assuntos
Aberrações Cromossômicas , Cromossomos Humanos/efeitos da radiação , Processamento de Imagem Assistida por Computador/métodos , Radiometria/métodos , Humanos , Doses de Radiação , Software
6.
Radiat Prot Dosimetry ; 172(1-3): 207-217, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27412514

RESUMO

The dose from ionizing radiation exposure can be interpolated from a calibration curve fit to the frequency of dicentric chromosomes (DCs) at multiple doses. As DC counts are manually determined, there is an acute need for accurate, fully automated biodosimetry calibration curve generation and analysis of exposed samples. Software, the Automated Dicentric Chromosome Identifier (ADCI), is presented which detects and discriminates DCs from monocentric chromosomes, computes biodosimetry calibration curves and estimates radiation dose. Images of metaphase cells from samples, exposed at 1.4-3.4 Gy, that had been manually scored by two reference laboratories were reanalyzed with ADCI. This resulted in estimated exposures within 0.4-1.1 Gy of the physical dose. Therefore, ADCI can determine radiation dose with accuracies comparable to standard triage biodosimetry. Calibration curves were generated from metaphase images in ~10 h, and dose estimations required ~0.8 h per 500 image sample. Running multiple instances of ADCI may be an effective response to a mass casualty radiation event.


Assuntos
Bioensaio/métodos , Aberrações Cromossômicas/efeitos da radiação , Interpretação de Imagem Assistida por Computador/métodos , Radiometria/métodos , Robótica/métodos , Software , Interface Usuário-Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Citometria de Fluxo/instrumentação , Citometria de Fluxo/métodos , Humanos , Reconhecimento Automatizado de Padrão/métodos , Doses de Radiação , Manejo de Espécimes/métodos
7.
J Mol Diagn ; 18(5): 657-667, 2016 09.
Artigo em Inglês | MEDLINE | ID: mdl-27376475

RESUMO

Advances in next-generation sequencing (NGS) have facilitated parallel analysis of multiple genes enabling the implementation of cost-effective, rapid, and high-throughput methods for the molecular diagnosis of multiple genetic conditions, including the identification of BRCA1 and BRCA2 mutations in high-risk patients for hereditary breast and ovarian cancer. We clinically validated a NGS pipeline designed to replace Sanger sequencing and multiplex ligation-dependent probe amplification analysis and to facilitate detection of sequence and copy number alterations in a single test focusing on a BRCA1/BRCA2 gene analysis panel. Our custom capture library covers 46 exons, including BRCA1 exons 2, 3, and 5 to 24 and BRCA2 exons 2 to 27, with 20 nucleotides of intronic regions both 5' and 3' of each exon. We analyzed 402 retrospective patients, with previous Sanger sequencing and multiplex ligation-dependent probe amplification results, and 240 clinical prospective patients. One-hundred eighty-three unique variants, including sequence and copy number variants, were detected in the retrospective (n = 95) and prospective (n = 88) cohorts. This standardized NGS pipeline demonstrated 100% sensitivity and 100% specificity, uniformity, and high-depth nucleotide coverage per sample (approximately 7000 reads per nucleotide). Subsequently, the NGS pipeline was applied to the analysis of larger gene panels, which have shown similar uniformity, sample-to-sample reproducibility in coverage distribution, and sensitivity and specificity for detection of sequence and copy number variants.


Assuntos
Testes Genéticos/métodos , Sequenciamento de Nucleotídeos em Larga Escala/normas , Reação em Cadeia da Polimerase Multiplex/normas , Técnicas de Amplificação de Ácido Nucleico/normas , Análise de Sequência de DNA/normas , Alelos , Estudos de Coortes , Variações do Número de Cópias de DNA , DNA Mitocondrial , Biblioteca Gênica , Genes BRCA1 , Genes BRCA2 , Testes Genéticos/normas , Genótipo , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Humanos , Reação em Cadeia da Polimerase Multiplex/métodos , Mutação , Neoplasias/diagnóstico , Neoplasias/genética , Técnicas de Amplificação de Ácido Nucleico/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Análise de Sequência de DNA/métodos
8.
BMC Med Genomics ; 9: 19, 2016 Apr 11.
Artigo em Inglês | MEDLINE | ID: mdl-27067391

RESUMO

BACKGROUND: Sequencing of both healthy and disease singletons yields many novel and low frequency variants of uncertain significance (VUS). Complete gene and genome sequencing by next generation sequencing (NGS) significantly increases the number of VUS detected. While prior studies have emphasized protein coding variants, non-coding sequence variants have also been proven to significantly contribute to high penetrance disorders, such as hereditary breast and ovarian cancer (HBOC). We present a strategy for analyzing different functional classes of non-coding variants based on information theory (IT) and prioritizing patients with large intragenic deletions. METHODS: We captured and enriched for coding and non-coding variants in genes known to harbor mutations that increase HBOC risk. Custom oligonucleotide baits spanning the complete coding, non-coding, and intergenic regions 10 kb up- and downstream of ATM, BRCA1, BRCA2, CDH1, CHEK2, PALB2, and TP53 were synthesized for solution hybridization enrichment. Unique and divergent repetitive sequences were sequenced in 102 high-risk, anonymized patients without identified mutations in BRCA1/2. Aside from protein coding and copy number changes, IT-based sequence analysis was used to identify and prioritize pathogenic non-coding variants that occurred within sequence elements predicted to be recognized by proteins or protein complexes involved in mRNA splicing, transcription, and untranslated region (UTR) binding and structure. This approach was supplemented by in silico and laboratory analysis of UTR structure. RESULTS: 15,311 unique variants were identified, of which 245 occurred in coding regions. With the unified IT-framework, 132 variants were identified and 87 functionally significant VUS were further prioritized. An intragenic 32.1 kb interval in BRCA2 that was likely hemizygous was detected in one patient. We also identified 4 stop-gain variants and 3 reading-frame altering exonic insertions/deletions (indels). CONCLUSIONS: We have presented a strategy for complete gene sequence analysis followed by a unified framework for interpreting non-coding variants that may affect gene expression. This approach distills large numbers of variants detected by NGS to a limited set of variants prioritized as potential deleterious changes.


Assuntos
Neoplasias da Mama/genética , DNA Intergênico/genética , Predisposição Genética para Doença , Padrões de Herança/genética , Mutação/genética , Neoplasias Ovarianas/genética , Sequência de Bases , Éxons/genética , Feminino , Humanos , Teoria da Informação , Dados de Sequência Molecular , Conformação de Ácido Nucleico , Polimorfismo de Nucleotídeo Único/genética , Ligação Proteica/genética , Isoformas de Proteínas/genética , Sítios de Splice de RNA/genética , Alinhamento de Sequência , Análise de Sequência de DNA , Deleção de Sequência/genética , Regiões não Traduzidas/genética
9.
Hum Mutat ; 37(7): 640-52, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26898890

RESUMO

BRCA1 and BRCA2 testing for hereditary breast and ovarian cancer (HBOC) does not identify all pathogenic variants. Sequencing of 20 complete genes in HBOC patients with uninformative test results (N = 287), including noncoding and flanking sequences of ATM, BARD1, BRCA1, BRCA2, CDH1, CHEK2, EPCAM, MLH1, MRE11A, MSH2, MSH6, MUTYH, NBN, PALB2, PMS2, PTEN, RAD51B, STK11, TP53, and XRCC2, identified 38,372 unique variants. We apply information theory (IT) to predict and prioritize noncoding variants of uncertain significance in regulatory, coding, and intronic regions based on changes in binding sites in these genes. Besides mRNA splicing, IT provides a common framework to evaluate potential affinity changes in transcription factor (TFBSs), splicing regulatory (SRBSs), and RNA-binding protein (RBBSs) binding sites following mutation. We prioritized variants affecting the strengths of 10 splice sites (four natural, six cryptic), 148 SRBS, 36 TFBS, and 31 RBBS. Three variants were also prioritized based on their predicted effects on mRNA secondary (2°) structure and 17 for pseudoexon activation. Additionally, four frameshift, two in-frame deletions, and five stop-gain mutations were identified. When combined with pedigree information, complete gene sequence analysis can focus attention on a limited set of variants in a wide spectrum of functional mutation types for downstream functional and co-segregation analysis.


Assuntos
Redes Reguladoras de Genes , Variação Genética , Síndrome Hereditária de Câncer de Mama e Ovário/genética , Proteína BRCA1/genética , Proteína BRCA2/genética , Feminino , Predisposição Genética para Doença , Humanos , Pessoa de Meia-Idade , Conformação de Ácido Nucleico , Splicing de RNA , RNA Mensageiro/química , RNA Mensageiro/genética , Análise de Sequência de DNA
10.
Mol Oncol ; 10(1): 85-100, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26372358

RESUMO

Increasingly, the effectiveness of adjuvant chemotherapy agents for breast cancer has been related to changes in the genomic profile of tumors. We investigated correspondence between growth inhibitory concentrations of paclitaxel and gemcitabine (GI50) and gene copy number, mutation, and expression first in breast cancer cell lines and then in patients. Genes encoding direct targets of these drugs, metabolizing enzymes, transporters, and those previously associated with chemoresistance to paclitaxel (n = 31 genes) or gemcitabine (n = 18) were analyzed. A multi-factorial, principal component analysis (MFA) indicated expression was the strongest indicator of sensitivity for paclitaxel, and copy number and expression were informative for gemcitabine. The factors were combined using support vector machines (SVM). Expression of 15 genes (ABCC10, BCL2, BCL2L1, BIRC5, BMF, FGF2, FN1, MAP4, MAPT, NFKB2, SLCO1B3, TLR6, TMEM243, TWIST1, and CSAG2) predicted cell line sensitivity to paclitaxel with 82% accuracy. Copy number profiles of 3 genes (ABCC10, NT5C, TYMS) together with expression of 7 genes (ABCB1, ABCC10, CMPK1, DCTD, NME1, RRM1, RRM2B), predicted gemcitabine response with 85% accuracy. Expression and copy number studies of two independent sets of patients with known responses were then analyzed with these models. These included tumor blocks from 21 patients that were treated with both paclitaxel and gemcitabine, and 319 patients on paclitaxel and anthracycline therapy. A new paclitaxel SVM was derived from an 11-gene subset since data for 4 of the original genes was unavailable. The accuracy of this SVM was similar in cell lines and tumor blocks (70-71%). The gemcitabine SVM exhibited 62% prediction accuracy for the tumor blocks due to the presence of samples with poor nucleic acid integrity. Nevertheless, the paclitaxel SVM predicted sensitivity in 84% of patients with no or minimal residual disease.


Assuntos
Antineoplásicos/uso terapêutico , Neoplasias da Mama/tratamento farmacológico , Desoxicitidina/análogos & derivados , Resistencia a Medicamentos Antineoplásicos/genética , Aprendizado de Máquina , Paclitaxel/uso terapêutico , Neoplasias da Mama/genética , Linhagem Celular Tumoral , Desoxicitidina/uso terapêutico , Feminino , Humanos , Máquina de Vetores de Suporte , Gencitabina
11.
J Thorac Oncol ; 9(9): 1255-63, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25122422

RESUMO

INTRODUCTION: Fluorescence in situ hybridization (FISH) is currently the standard for diagnosing anaplastic lymphoma kinase (ALK)-rearranged (ALK+) lung cancers for ALK inhibitor therapies. ALK immunohistochemistry (IHC) may serve as a screening and alternative diagnostic method. The Canadian ALK (CALK) study was initiated to implement a multicenter optimization and standardization of laboratory developed ALK IHC and FISH tests across 14 hospitals. METHODS: Twenty-eight lung adenocarcinomas with known ALK status were used as blinded study samples. Thirteen laboratories performed IHC using locally developed staining protocols for 5A4, ALK1, or D5F3 antibodies; results were assessed by H-score. Twelve centers conducted FISH using protocols based on Vysis' ALK break-apart FISH kit. Initial IHC results were used to optimize local IHC protocols, followed by a repeat IHC study to assess the results of standardization. Three laboratories conducted a prospective parallel IHC and FISH analysis on 411 consecutive clinical samples using post-validation optimized assays. RESULTS: Among study samples, FISH demonstrated 22 consensus ALK+ and six ALK wild type tumors. Preoptimization IHC scores from 12 centers with 5A4 and the percent abnormal cells by FISH from 12 centers showed intraclass correlation coefficients of 0.83 and 0.68, respectively. IHC optimization improved the intraclass correlation coefficients to 0.94. Factors affecting FISH scoring and outliers were identified. Post-optimization concurrent IHC/FISH testing in 373 informative cases revealed 100% sensitivity and specificity for IHC versus FISH. CONCLUSIONS: Multicenter standardization study may accelerate the implementation of ALK testing protocols across a country/region. Our data support the use of an appropriately validated IHC assay to screen for ALK+ lung cancers.


Assuntos
Adenocarcinoma/enzimologia , Neoplasias Pulmonares/enzimologia , Receptores Proteína Tirosina Quinases/metabolismo , Adenocarcinoma/diagnóstico , Adenocarcinoma/genética , Adenocarcinoma de Pulmão , Quinase do Linfoma Anaplásico , Canadá , DNA de Neoplasias/genética , Feminino , Seguimentos , Humanos , Imuno-Histoquímica , Hibridização in Situ Fluorescente/métodos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Receptores Proteína Tirosina Quinases/genética , Reprodutibilidade dos Testes , Reação em Cadeia da Polimerase Via Transcriptase Reversa
12.
Nucleic Acids Res ; 41(7): e81, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23376933

RESUMO

Diagnostic DNA hybridization relies on probes composed of single copy (sc) genomic sequences. Sc sequences in probe design ensure high specificity and avoid cross-hybridization to other regions of the genome, which could lead to ambiguous results that are difficult to interpret. We examine how the distribution and composition of repetitive sequences in the genome affects sc probe performance. A divide and conquer algorithm was implemented to design sc probes. With this approach, sc probes can include divergent repetitive elements, which hybridize to unique genomic targets under higher stringency experimental conditions. Genome-wide custom probe sets were created for fluorescent in situ hybridization (FISH) and microarray genomic hybridization. The scFISH probes were developed for detection of copy number changes within small tumour suppressor genes and oncogenes. The microarrays demonstrated increased reproducibility by eliminating cross-hybridization to repetitive sequences adjacent to probe targets. The genome-wide microarrays exhibited lower median coefficients of variation (17.8%) for two HapMap family trios. The coefficients of variations of commercial probes within 300 nt of a repetitive element were 48.3% higher than the nearest custom probe. Furthermore, the custom microarray called a chromosome 15q11.2q13 deletion more consistently. This method for sc probe design increases probe coverage for FISH and lowers variability in genomic microarrays.


Assuntos
Hibridização Genômica Comparativa/métodos , Sondas de DNA , Hibridização in Situ Fluorescente/métodos , Algoritmos , Síndrome de Angelman/genética , Deleção Cromossômica , Cromossomos Humanos Par 15 , DNA/química , Genoma Humano , Humanos , Sequências Repetitivas de Ácido Nucleico , Reprodutibilidade dos Testes
13.
Mol Oncol ; 6(3): 347-59, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22342187

RESUMO

BACKGROUND: Cancer genomes accumulate frequent and diverse chromosomal abnormalities as well as gene mutations but must maintain the ability to survive in vivo. We hypothesize that genetic selection acts to maintain tumour survival by preserving copy number of specific genes and genomic regions. Genomic regions and genes that remain unaltered in copy number and expression, respectively, may be essential for maintaining tumour survival. METHODS: We analyzed copy number data of 243 previously reported breast tumours and computationally derived stable copy number regions. To identify genes in stable copy number regions with nominal changes in expression, datasets for tumour and normal samples were compared. Results were replicated by analysis of a series of independent copy number, expression and genomic sequencing studies. A subset of stable regions, including stable paralogous regions, were confirmed by quantitative PCR and fluorescence in situ hybridization (FISH) in 5 breast cancer cell lines. We deduced a comprehensive set of dually stable genes (i.e. maintaining nominal copy number and expression) which were categorized according to pathway and ontology assignments. The stability of genes encoding therapeutic drug targets was also assessed. RESULTS AND CONCLUSION: Tumour genome analysis revealed 766 unstable (amplified and/or deleted) and 812 stable contiguous genomic regions. Replication analysis of an independent set of 171 breast tumours confirmed copy number stability of 1.3 Gb of the genome. We found that 5804 of these genes were dually stable. The composition of this gene set remained essentially unchanged (<2% reduction) after accounting for commonly mutated breast cancer genes found by sequencing and differential expression. The stable breast cancer genome is enriched for cellular metabolism, regulation of gene expression, DNA packaging (chromatin and nucleosome assembly), and regulation of apoptosis functions. Stable genes participating in multiple essential pathways were consistently found to be targets of chemotherapies. Preservation of stable, essential genes may be related to the effectiveness of certain chemotherapeutic agents that act on multiple gene products in this set.


Assuntos
Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Genoma Humano/genética , Antineoplásicos/uso terapêutico , Feminino , Humanos , Hibridização in Situ Fluorescente , Reação em Cadeia da Polimerase
14.
Hum Mutat ; 27(4): 376-86, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16541397

RESUMO

We developed a novel quantitative microsphere suspension hybridization (QMH) assay for determination of genomic copy number by flow cytometry. Single copy (sc) products ranging in length from 62 to 2,304 nucleotides [Rogan et al., 2001; Knoll and Rogan, 2004] from ABL1 (chromosome 9q34), TEKT3 (17p12), PMP22 (17p12), and HOXB1 (17q21) were conjugated to spectrally distinct polystyrene microspheres. These conjugated probes were used in multiplex hybridization to detect homologous target sequences in biotinylated genomic DNA extracted from fixed cell pellets obtained for cytogenetic studies. Hybridized targets were bound to phycoerythrin-labeled streptavidin; then the spectral emissions of both target and conjugated microsphere were codetected by flow cytometry. Prior amplification of locus-specific target DNA was not required because sc probes provide adequate specificity and sensitivity for accurate copy number determination. Copy number differences were distinguishable by comparing the mean fluorescence intensities (MFI) of test probes with a biallelic reference probe in genomic DNA of patient samples and abnormal cell lines. Concerted 5' ABL1 deletions in patient samples with a chromosome 9;22 translocation and chronic myelogenous leukemia were confirmed by comparison of the mean fluorescence intensities of ABL1 test probes with a HOXB1 reference probe. The relative intensities of the ABL1 probes were reduced to 0.59+/-0.02 fold in three different deletion patients and increased 1.42+/-0.01 fold in three trisomic 9 cell lines. TEKT3 and PMP22 probes detected proportionate copy number increases in five patients with Charcot-Marie-Tooth Type 1a disease and chromosome 17p12 duplications. Thus, the assay is capable of distinguishing one allele and three alleles from a biallelic reference sequence, regardless of chromosomal context.


Assuntos
Dosagem de Genes/genética , Genômica/métodos , Microesferas , Hibridização de Ácido Nucleico/métodos , Linhagem Celular , Doença de Charcot-Marie-Tooth/genética , Aberrações Cromossômicas , Deleção Cromossômica , Cromossomos Humanos Par 19/genética , Cromossomos Humanos Par 9/genética , Sondas de DNA , Genoma Humano , Humanos , Sensibilidade e Especificidade , Trissomia/genética
15.
Mol Cell Probes ; 20(2): 114-20, 2006 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-16460913

RESUMO

Acute promyelocytic leukemia (AML-M3) is characterized by a translocation between chromosomes 15 and 17 [t(15;17)]. The detection of t(15;17) at the single cell level, is commonly done by fluorescence in situ hybridization (FISH) using recombinant locus specific genomic probes greater than 14 kilobases kb in length. To allow a more thorough study of t(15;17), we designed small (0.9-3.6 kb), target-specific, single-copy probes from the human genome sequence. A novel detection approach was evaluated using moieties possessing more fluorophores, DNA dendrimers (up to 375 fluorophores per dendrimer). Two detection approaches were evaluated using the dendrimers: (1) dendrimers modified with anti-biotin antibodies for detection of biotinylated bound probes, and (2) dendrimers modified with 45-base long oligonucleotides designed from the single-copy probes, for direct detection of the target region. The selectivity of the probes was confirmed via indirect labeling with biotin/digoxigenin by nick translation, with detection efficiencies between 50 and 90%. Furthermore, the scFISH probes were successfully detected on metaphase cells with anti-biotin dendrimer conjugates and on interphase cells with 45-base modified dendrimers. Our results bring up the possibility to detect target regions of less than 1 kb, which will be a great contribution to high-resolution analysis of genomic sequences.


Assuntos
Genoma Humano , Leucemia Promielocítica Aguda/genética , Translocação Genética , Linhagem Celular Tumoral , Cromossomos Humanos Par 15/genética , Cromossomos Humanos Par 17/genética , Sondas de DNA/química , Dendrímeros/química , Humanos , Hibridização in Situ Fluorescente , Interfase , Leucemia Promielocítica Aguda/patologia , Metáfase
16.
Discov Med ; 4(21): 99-101, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20705001

RESUMO

Extract: Numerical and structural chromosome abnormalities are a common cause of inherited and acquired diseases in humans. Cytogenetic detection of genomic imbalances and rearrangements is standard diagnostic practice, and is used both prognostically and for treatment stratification, especially for neoplastic disorders. Abnormalities are recognized by chromosome banding and by fluorescence in situ hybridization (FISH). FISH permits examination of specific DNA sequences within single or multiple chromosome bands on a metaphase cell or within an interphase cell. Locus-specific FISH probes have traditionally been composed of recombinant DNA segments that span large chromosomal targets of hundreds of thousands of base pairs, about an order of magnitude smaller than the length of a typical chromosomal band. These probes, which contain either repetitive sequences, single copy sequences or combinations of both, have been developed to hybridize to a wide spectrum of chromosomal targets -- encompassing a single gene to an entire chromosome. Commercially available clones are generally useful for detecting more common abnormalities, whereas, detection or characterization of rare chromosomal abnormalities by FISH has relied on clones obtained from research laboratories.

17.
Am J Med Genet A ; 121A(3): 245-57, 2003 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-12923866

RESUMO

We developed single copy probes from the draft genome sequence for fluorescence in situ hybridization (scFISH) which precisely delineate chromosome abnormalities at a resolution equivalent to genomic Southern analysis. This study illustrates how scFISH probes detect cryptic and subtle abnormalities and localize the sites of chromosome rearrangements. scFISH probes are substantially shorter than conventional recombinant DNA-derived probes, and C(o)t1 DNA is not required to suppress repetitive sequence hybridization. In this study, 74 single copy sequence probes (>1,500 bp) have been developed from >/=100 kb genomic intervals associated with either constitutional or acquired disorders. Applications of these probes include detection of congenital microdeletion syndromes on chromosomes 1, 4, 7, 15, 17, 22 and submicroscopic deletions involving the imprinting center on chromosome 15q11.2q13. We demonstrate how hybridization with multiple combinations of probes derived from the Smith-Magenis syndrome interval on chromosome 17 identified a patient with an atypical, proximal deletion breakpoint. A similar multi-probe hybridization strategy has also been used to delineate the translocation breakpoint region on chromosome 9 in chronic myelogenous leukemia. Probes have also been designed to hybridize to multiple cis paralogs, both enhancing the chromosomal target size and detecting chromosome rearrangements, for example, by splitting and separating a family of related sequences flanking an inversion breakpoint on chromosome 16 in acute myelogenous leukemia. These novel strategies for rapid and precise characterization of cytogenetic abnormalities are feasible because of the sequence-defined properties and dense euchromatic organization of single copy probes.


Assuntos
Aberrações Cromossômicas , Sondas de DNA/síntese química , Deleção de Genes , Hibridização in Situ Fluorescente/métodos , Análise de Sequência de DNA/métodos , Translocação Genética , Adulto , Southern Blotting , Criança , Cromossomos Humanos Par 15/genética , Cromossomos Humanos Par 16/genética , Cromossomos Humanos Par 17/genética , Sondas de DNA/análise , Sondas de DNA/isolamento & purificação , Dosagem de Genes , Genoma Humano , Humanos , Leucemia Mielogênica Crônica BCR-ABL Positiva/genética , Hibridização de Ácido Nucleico , Síndrome de Prader-Willi/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA