Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Med Dosim ; 34(1): 87-90, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19181261

RESUMO

The recent broad adoption of 4-D computed tomography (4DCT) scanning in radiotherapy has allowed the accurate determination of the target volume of tumors by minimizing image degradation caused by respiratory motion. Although the radiation exposure of the treatment beam is significantly greater than that of CT scans used for treatment planning, it is important to recognize and optimize the radiation exposure in 4DCT from the radiological protection point of view. Here, radiation exposure in 4DCT was measured with a 16 multidetector CT. Organ doses were measured using thermoluminescence radiation dosimeter chips inserted at respective anatomical sites of an anthropomorphic phantom. Results were compared with those with the helical CT scan mode. The effective dose measured for 4DCT was 24.7 mSv, approximately four times higher than that for helical CT. However, the increase in treatment accuracy afforded by 4DCT means its use in radiotherapy is inevitable. The patient exposure in the 4DCT could be of value by clarifying the advantage of the treatment planning using 4DCT.


Assuntos
Pulmão/diagnóstico por imagem , Pulmão/efeitos da radiação , Doses de Radiação , Planejamento da Radioterapia Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Protocolos Clínicos , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Dosagem Radioterapêutica/normas , Dosimetria Termoluminescente
2.
Radiother Oncol ; 86(2): 258-63, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-18023489

RESUMO

INTRODUCTION: The characteristics of a glass dosimeter were investigated for its potential use as a tool for postal dose audits. Reproducibility, energy dependence, field size and depth dependence were compared to those of a thermoluminescence dosimeter (TLD), which has been the major tool for postal dose audits worldwide. MATERIALS AND METHODS: A glass dosimeter, GD-302M (Asahi Techno Glass Co.) and a TLD, TLD-100 chip (Harshaw Co.) were irradiated with gamma-rays from a (60)Co unit and X-rays from a medical linear accelerator (4, 6, 10 and 20 MV). RESULTS: The dosimetric characteristics of the glass dosimeter were almost equivalent to those of the TLD, in terms of utility for dosimetry under the reference condition, which is a 10 x 10 cm(2) field and 10 cm depth. Because of its reduced fading, compared to the TLD, and easy quality control with the ID number, the glass dosimeter proved to be a suitable tool for postal dose audits. Then, we conducted postal dose surveys of over 100 facilities and got good agreement, with a standard deviation of about 1.3%. CONCLUSIONS: Based on this study, postal dose audits throughout Japan will be carried out using a glass dosimeter.


Assuntos
Dosimetria Termoluminescente , Estudos de Viabilidade , Vidro , Humanos , Japão , Fótons , Projetos Piloto , Serviços Postais , Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS