Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Curr Opin Neurol ; 37(2): 141-151, 2024 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-38334495

RESUMO

PURPOSE OF REVIEW: To review the current practices and evidence for the diagnostic accuracy and the benefits of presurgical evaluation. RECENT FINDINGS: Preoperative evaluation of patients with drug-resistant focal epilepsies and subsequent epilepsy surgery leads to a significant proportion of seizure-free patients. Even those who are not completely seizure free postoperatively often experience improved quality of life with better social integration. Systematic reviews and meta-analysis on the diagnostic accuracy are available for Video-electroencephalographic (EEG) monitoring, magnetic resonance imaging (MRI), electric and magnetic source imaging, and functional MRI for lateralization of language and memory. There are currently no evidence-based international guidelines for presurgical evaluation and epilepsy surgery. SUMMARY: Presurgical evaluation is a complex multidisciplinary and multiprofessional clinical pathway. We rely on limited consensus-based recommendations regarding the required staffing or methodological expertise in epilepsy centers.


Assuntos
Epilepsia Resistente a Medicamentos , Epilepsia , Humanos , Epilepsia Resistente a Medicamentos/diagnóstico por imagem , Epilepsia Resistente a Medicamentos/cirurgia , Qualidade de Vida , Eletroencefalografia/métodos , Epilepsia/diagnóstico por imagem , Epilepsia/cirurgia , Imageamento por Ressonância Magnética/métodos , Resultado do Tratamento
2.
Epileptic Disord ; 24(2): 323-342, 2022 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-34961746

RESUMO

MRI is a cornerstone in presurgical evaluation of epilepsy. Despite guidelines, clinical practice varies. In light of the E-PILEPSY pilot reference network, we conducted a systematic review and meta-analysis on the diagnostic value of MRI in the presurgical evaluation of epilepsy patients. We included original research articles on diagnostic value of higher MRI field strength and guideline-recommended and additional MRI sequences in detecting an epileptogenic lesion in adult or paediatric epilepsy surgery candidates. Lesion detection rate was used as a metric in meta-analysis. Eighteen studies were included for MRI field strength and 25 for MRI sequences, none were free from bias. In patients with normal MRI at lower-field strength, 3T improved lesion detection rate by 18% and 7T by 23%. Field strengths higher than 1.5T did not have higher lesion detection rates in patients with hippocampal sclerosis (HS). The lesion detection rate of epilepsy-specific MRI protocols was 83% for temporal lobe epilepsy (TLE) patients. Dedicated MRI protocols and evaluation by an experienced epilepsy neuroradiologist increased lesion detection. For HS, 3DT1, T2, and FLAIR each had a lesion detection rate at around 90%. Apparent diffusion coefficient indices had a lateralizing value of 33% for TLE. DTI fractional anisotropy and mean diffusivity had a localizing value of 8% and 34%. A dedicated MRI protocol and expert evaluation benefits lesion detection rate in epilepsy surgery candidates. If patients remain MRI negative, imaging at higher-field strength may reveal lesions. In HS, apparent diffusion coefficient indices may aid lateralization and localization more than increasing field strength. DTI can add further diagnostic information. For other additional sequences, the quality and number of studies is insufficient to draw solid conclusions. Our findings may be used as evidence base for developing new high-quality MRI studies and clinical guidelines.


Assuntos
Epilepsia do Lobo Temporal , Epilepsia , Adulto , Criança , Epilepsia/diagnóstico , Epilepsia/patologia , Epilepsia/cirurgia , Epilepsia do Lobo Temporal/patologia , Hipocampo/patologia , Humanos , Imageamento por Ressonância Magnética/métodos
3.
Clin Neurophysiol ; 130(5): 845-855, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30824202

RESUMO

OBJECTIVE: Interictal high resolution (HR-) electric source imaging (ESI) and magnetic source imaging (MSI) are non-invasive tools to aid epileptogenic zone localization in epilepsy surgery candidates. We carried out a systematic review on the diagnostic accuracy and quality of evidence of these modalities. METHODS: Embase, Pubmed and the Cochrane database were searched on 13 February 2017. Diagnostic accuracy studies taking post-surgical seizure outcome as reference standard were selected. Quality appraisal was based on the QUADAS-2 framework. RESULTS: Eleven studies were included: eight MSI (n = 267), three HR-ESI (n = 127) studies. None was free from bias. This mostly involved: selection of operated patients only, interference of source imaging with surgical decision, and exclusion of indeterminate results. Summary sensitivity and specificity estimates were 82% (95% CI: 75-88%) and 53% (95% CI: 37-68%) for overall source imaging, with no statistical difference between MSI and HR-ESI. Specificity is higher when partially concordant results were included as non-concordant (p < 0.05). Inclusion of indeterminate test results as non-concordant lowered sensitivity (p < 0.05). CONCLUSIONS: Source imaging has a relatively high sensitivity but low specificity for identification of the epileptogenic zone. SIGNIFICANCE: We need higher quality studies allowing unbiased test evaluation to determine the added value and diagnostic accuracy of source imaging in the presurgical workup of refractory focal epilepsy.


Assuntos
Mapeamento Encefálico/métodos , Eletroencefalografia , Epilepsia/cirurgia , Imageamento por Ressonância Magnética , Magnetoencefalografia , Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Humanos , Sensibilidade e Especificidade
4.
Epilepsia ; 59(12): 2272-2283, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30511441

RESUMO

OBJECTIVE: The European Union-funded E-PILEPSY network (now continuing within the European Reference Network for rare and complex epilepsies [EpiCARE]) aims to harmonize and optimize presurgical diagnostic procedures by creating and implementing evidence-based guidelines across Europe. The present study evaluates the current evidence on the diagnostic accuracy of long-term video-electroencephalographic monitoring (LTM) in identifying the epileptogenic zone in epilepsy surgery candidates. METHODS: MEDLINE, Embase, CENTRAL, and ClinicalTrials.gov were searched for relevant articles. First, we used random-effects meta-analytical models to calculate pooled estimates of sensitivity and specificity with respect to postsurgical seizure freedom. In a second phase, we analyzed individual patient data in an exploratory fashion, assessing diagnostic accuracy within lesional and nonlesional temporal lobe epilepsy (TLE) and extratemporal lobe epilepsy (ETLE) patients. We also evaluated seizure freedom rate in the presence of "localizing" or "nonlocalizing" LTM within each group. The quality of evidence was assessed using the QUADAS-2 tool and the GRADE approach. RESULTS: Ninety-four studies were eligible. Forty-four were included in sensitivity meta-analysis and 34 in specificity meta-analysis. Pooled sensitivity was 0.70 (95% confidence interval [CI] = 0.60-0.80) and specificity was 0.40 (95% CI = 0.27-0.54). Subgroup analysis was based on individual data of 534 patients (41% men). In lesional TLE patients, sensitivity was 0.85 (95% CI = 0.81-0.89) and specificity was -0.19 (95% CI = 0.13-0.28). In lesional ETLE patients, a sensitivity of 0.47 (95% CI = 0.36-0.58) and specificity of 0.35 (95% CI = 0.21-0.53) were observed. In lesional TLE, if LTM was localizing and concordant with resection site, the seizure freedom rate was 247 of 333 (74%), whereas in lesional ETLE it was 34 of 56 (61%). The quality of evidence was assigned as "very low." SIGNIFICANCE: Long-term video-electroencephalographic monitoring is associated with moderate sensitivity and low specificity in identification of the epileptogenic zone. Sensitivity is remarkably higher in lesional TLE compared to lesional ETLE. Substantial heterogeneity across the studies indicates the need for improved design and quality of reporting.


Assuntos
Eletroencefalografia/métodos , Epilepsia/diagnóstico , Epilepsia/cirurgia , Procedimentos Neurocirúrgicos , Humanos , Monitorização Fisiológica , Prognóstico , Reprodutibilidade dos Testes
5.
Epilepsia ; 59(12): 2305-2317, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30374948

RESUMO

OBJECTIVE: The European Union-funded E-PILEPSY project was launched to develop guidelines and recommendations for epilepsy surgery. In this systematic review, we aimed to assess the diagnostic accuracy of functional magnetic resonance imaging (fMRI), Wada test, magnetoencephalography (MEG), and functional transcranial Doppler sonography (fTCD) for memory and language decline after surgery. METHODS: The literature search was conducted using PubMed, Embase, and CENTRAL. The diagnostic accuracy was expressed in terms of sensitivity and specificity for postoperative language or memory decline, as determined by pre- and postoperative neuropsychological assessments. If two or more estimates of sensitivity or specificity were extracted from a study, two meta-analyses were conducted, using the maximum ("best case") and the minimum ("worst case") of the extracted estimates, respectively. RESULTS: Twenty-eight papers were eligible for data extraction and further analysis. All tests for heterogeneity were highly significant, indicating large between-study variability (P < 0.001). For memory outcomes, meta-analyses were conducted for Wada tests (n = 17) using both memory and language laterality quotients. In the best case, meta-analyses yielded a sensitivity estimate of 0.79 (95% confidence interval [CI] = 0.67-0.92) and a specificity estimate of 0.65 (95% CI = 0.47-0.83). For the worst case, meta-analyses yielded a sensitivity estimate of 0.65 (95% CI = 0.48-0.82) and a specificity estimate of 0.46 (95% CI = 0.28-0.65). The overall quality of evidence, which was assessed using Grading of Recommendations Assessment, Development, and Evaluation methodology, was rated as very low. Meta-analyses concerning diagnostic accuracy of fMRI, fTCD, and MEG were not feasible due to small numbers of studies (fMRI, n = 4; fTCD, n = 1; MEG, n = 0). This also applied to studies concerning language outcomes (Wada test, n = 6; fMRI, n = 2; fTCD, n = 1; MEG, n = 0). SIGNIFICANCE: Meta-analyses could only be conducted in a few subgroups for the Wada test with low-quality evidence. Thus, more evidence from high-quality studies and improved data reporting are required. Moreover, the large between-study heterogeneity underlines the necessity for more homogeneous and thus comparable studies in future research.


Assuntos
Epilepsia/cirurgia , Transtornos da Linguagem/etiologia , Testes de Linguagem , Imageamento por Ressonância Magnética/métodos , Magnetoencefalografia/métodos , Transtornos da Memória/etiologia , Complicações Pós-Operatórias/psicologia , Ultrassonografia Doppler Transcraniana/métodos , Amobarbital , Humanos , Sensibilidade e Especificidade
6.
Epilepsia ; 58(3): 343-355, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-28067423

RESUMO

We explored the current practice with respect to the neuropsychological assessment of surgical epilepsy patients in European epilepsy centers, with the aim of harmonizing and establishing common standards. Twenty-six epilepsy centers and members of "E-PILEPSY" (a European pilot network of reference centers in refractory epilepsy and epilepsy surgery), were asked to report the status of neuropsychological assessment in adults and children via two different surveys. There was a consensus among these centers regarding the role of neuropsychology in the presurgical workup. Strong agreement was found on indications (localization, epileptic dysfunctions, adverse drugs effects, and postoperative monitoring) and the domains to be evaluated (memory, attention, executive functions, language, visuospatial skills, intelligence, depression, anxiety, and quality of life). Although 186 different tests are in use throughout these European centers, a core group of tests reflecting a moderate level of agreement could be discerned. Variability exists with regard to indications, protocols, and paradigms for the assessment of hemispheric language dominance. For the tests in use, little published evidence of clinical validity in epilepsy was provided. Participants in the survey reported a need for improvement concerning the validity of the tests, tools for the assessment of everyday functioning and accelerated forgetting, national norms, and test co-normalization. Based on the present survey, we documented a consensus regarding the indications and principles of neuropsychological testing. Despite the variety of tests in use, the survey indicated that there may be a core set of tests chosen based on experience, as well as on published evidence. By combining these findings with the results of an ongoing systematic literature review, we aim for a battery that can be recommended for the use across epilepsy surgical centers in Europe.


Assuntos
Transtornos Cognitivos , Epilepsia/cirurgia , Testes Neuropsicológicos/normas , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/epidemiologia , Transtornos Cognitivos/etiologia , Epilepsia/complicações , Epilepsia/epidemiologia , Europa (Continente)/epidemiologia , Pesquisas sobre Atenção à Saúde/estatística & dados numéricos , Humanos , Cooperação Internacional , Neuroimagem
7.
Seizure ; 38: 38-45, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27104922

RESUMO

PURPOSE: The European Union-funded E-PILEPSY network aims to improve awareness of, and accessibility to, epilepsy surgery across Europe. In this study we assessed current clinical practices in epilepsy monitoring units (EMUs) in the participating centers. METHOD: A 60-item web-based survey was distributed to 25 centers (27 EMUs) of the E-PILEPSY network across 22 European countries. The questionnaire was designed to evaluate the characteristics of EMUs, including organizational aspects, admission, and observation of patients, procedures performed, safety issues, cost, and reimbursement. RESULTS: Complete responses were received from all (100%) EMUs surveyed. Continuous observation of patients was performed in 22 (81%) EMUs during regular working hours, and in 17 EMUs (63%) outside of regular working hours. Fifteen (56%) EMUs requested a signed informed consent before admission. All EMUs performed tapering/withdrawal of antiepileptic drugs, 14 (52%) prior to admission to an EMU. Specific protocols on antiepileptic drugs (AED) tapering were available in four (15%) EMUs. Standardized Operating Procedures (SOP) for the treatment of seizure clusters and status epilepticus were available in 16 (59%). Safety measures implemented by EMUs were: alarm seizure buttons in 21 (78%), restricted patient's ambulation in 19 (70%), guard rails in 16 (59%), and specially designated bathrooms in 7 (26%). Average costs for one inpatient day in EMU ranged between 100 and 2200 Euros. CONCLUSION: This study shows a considerable diversity in the organization and practice patterns across European epilepsy monitoring units. The collected data may contribute to the development and implementation of evidence-based recommended practices in LTM services across Europe.


Assuntos
Epilepsia Resistente a Medicamentos/diagnóstico , Eletroencefalografia/estatística & dados numéricos , Monitorização Fisiológica/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Europa (Continente) , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Adulto Jovem
8.
Epilepsia ; 57(5): 770-6, 2016 May.
Artigo em Inglês | MEDLINE | ID: mdl-27012361

RESUMO

OBJECTIVE: In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. METHODS: A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. RESULTS: Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. SIGNIFICANCE: We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods.


Assuntos
Epilepsia/diagnóstico por imagem , Epilepsia/fisiopatologia , Neuroimagem , Epilepsia/cirurgia , Europa (Continente)/epidemiologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Cooperação Internacional , Masculino , Neuroimagem/métodos , Neuroimagem/estatística & dados numéricos , Neuroimagem/tendências , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA