Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-37174152

RESUMO

Clinical and economic burdens exist within the coronary artery disease (CAD) care pathway despite advances in diagnosis and treatment and the increasing utilization of percutaneous coronary intervention (PCI). However, research presenting a comprehensive assessment of the challenges across this pathway is scarce. This contemporary review identifies relevant studies related to inefficiencies in the diagnosis, treatment, and management of CAD, including clinician, patient, and economic burdens. Studies demonstrating the benefits of integration and automation within the catheterization laboratory and across the CAD care pathway were also included. Most studies were published in the last 5-10 years and focused on North America and Europe. The review demonstrated multiple potentially avoidable inefficiencies, with a focus on access, appropriate use, conduct, and follow-up related to PCI. Inefficiencies included misdiagnosis, delays in emergency care, suboptimal testing, longer procedure times, risk of recurrent cardiac events, incomplete treatment, and challenges accessing and adhering to post-acute care. Across the CAD pathway, this review revealed that high clinician burnout, complex technologies, radiation, and contrast media exposure, amongst others, negatively impact workflow and patient care. Potential solutions include greater integration and interoperability between technologies and systems, improved standardization, and increased automation to reduce burdens in CAD and improve patient outcomes.


Assuntos
Doença da Artéria Coronariana , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/cirurgia , Doença da Artéria Coronariana/diagnóstico , Intervenção Coronária Percutânea/métodos , Procedimentos Clínicos , Resultado do Tratamento , Pacientes , Fatores de Risco
2.
J Interv Cardiol ; 2021: 9971874, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34149324

RESUMO

BACKGROUND: To validate a simplified invasive method for the calculation of the index of microvascular resistance (IMR). METHODS: This is a prospective, single-center study of patients with chronic coronary syndromes presenting with nonobstructive coronary artery disease. IMR was obtained using both intravenous (IV) adenosine and intracoronary (IC) papaverine. Each IMR measurement was obtained in duplicate. The primary objective was the agreement between IMR acquired using adenosine and papaverine. Secondary objectives include reproducibility of IMR and time required for the IMR measurement. RESULTS: One hundred and sixteen IMR measurements were performed in 29 patients. The mean age was 68.8 ± 7.24 years, and 27.6% was diabetics. IMR values were similar between papaverine and adenosine (17.7 ± 7.26 and 20.1 ± 8.6, p=0.25; Passing-Bablok coefficient A 0.58, 95% CI -2.42 to 3.53; coefficient B 0.90, 95% CI -0.74 to 1.07). The reproducibility of IMR was excellent with both adenosine and papaverine (ICC 0.78, 95% CI 0.63 to 0.88 and ICC 0.93, 95% CI 0.87 to 0.97). The time needed for microvascular assessment was significantly shortened by the use of IC papaverine (3.23 (2.84, 3.78) mins vs. 5.48 (4.94, 7.09) mins, p < 0.0001). CONCLUSION: IMR can be reliably measured using IC papaverine with similar results compared to intravenous infusion of adenosine with increased reproducibility and reduced procedural time. This approach simplifies the invasive assessment of the coronary microcirculation in the catheterization laboratory.


Assuntos
Cateterismo Cardíaco , Doença da Artéria Coronariana , Microcirculação/fisiologia , Duração da Cirurgia , Resistência Vascular/fisiologia , Idoso , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco/normas , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/fisiopatologia , Circulação Coronária/fisiologia , Vasos Coronários/fisiopatologia , Feminino , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Simplificação do Trabalho
3.
Circ Cardiovasc Interv ; 13(10): e009157, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-33040579

RESUMO

BACKGROUND: In diabetic patients with multivessel coronary artery disease, coronary artery bypass grafting (CABG) has shown long-term benefits over percutaneous coronary intervention (PCI). Physiology-guided PCI has shown to improve clinical outcomes in multivessel coronary artery disease, though its impact in diabetic patients has never been investigated. We evaluated long-term clinical outcomes of diabetic patients with multivessel coronary artery disease treated with fractional flow reserve (FFR)-guided PCI compared with CABG. METHODS: From 2010 to 2018, 4622 diabetic patients undergoing coronary angiography were screened for inclusion. The inclusion criterion was the presence of at least 2-vessel disease defined as with diameter stenosis ≥50%, in which at least 1 intermediate stenosis (diameter stenosis, 30%-70%) was treated or deferred according to FFR. Inverse probability of treatment weighting analysis was used to account for baseline differences with a contemporary cohort of patients treated with CABG. The primary end point was major adverse cardiovascular and cerebrovascular events, defined as all-cause death, myocardial infarction, revascularization, or stroke. RESULTS: A total of 418 patients were included in the analysis. Among them, 209 patients underwent CABG and 209 FFR-guided PCI. At 5 years, the incidence of major adverse cardiovascular and cerebrovascular events was higher in the FFR-guided PCI versus the CABG group (44.5% versus 31.9%; hazard ratio, 1.60 [95% CI, 1.15-2.22]; P=0.005). No difference was found in the composite of all-cause death, myocardial infarction, or stroke (28.8% versus 27.5%; hazard ratio, 1.05 [95% CI, 0.72-1.53]; P=0.81). Repeat revascularization was more frequent with FFR-guided PCI (24.9% versus 8.2%; hazard ratio, 3.51 [95% CI, 1.93-6.40]; P<0.001). CONCLUSIONS: In diabetic patients with multivessel coronary artery disease, CABG was associated with a lower rate of major adverse cardiovascular and cerebrovascular events compared with FFR-guided PCI, driven by a higher rate of repeat revascularization. At 5-year follow-up, no difference was observed in the composite of all-cause death, myocardial infarction, or stroke between CABG and FFR-guided PCI. Graphic Abstract: A graphic abstract is available for this article.


Assuntos
Cateterismo Cardíaco , Ponte de Artéria Coronária , Doença da Artéria Coronariana/terapia , Estenose Coronária/terapia , Diabetes Mellitus , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Tomada de Decisão Clínica , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Ponte de Artéria Coronária/mortalidade , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/mortalidade , Doença da Artéria Coronariana/fisiopatologia , Estenose Coronária/diagnóstico , Estenose Coronária/mortalidade , Estenose Coronária/fisiopatologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA