Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Spine (Phila Pa 1976) ; 47(10): E456-E465, 2022 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-34935758

RESUMO

STUDY DESIGN: Finite element analysis (FEA). OBJECTIVE: The aim of this study was to determine biomechanical differences between traditional growing rod (TGR) and spring distraction system (SDS) treatment of early-onset scoliosis. SUMMARY OF BACKGROUND DATA: Many "growth-friendly" implants like the TGR show high rates of implant failure, spinal stiffening, and intervertebral disc (IVD) height loss. We developed the SDS, which employs continuous, dynamic forces to mitigate these limitations. The present FEA compares TGR and SDS implantation, followed by an 18-month growth period. METHODS: Two representative, ligamentous, scoliotic FEA models were created for this study; one representing TGR and one representing SDS. initial implantation, and up to 18 months of physeal spinal growth were simulated. The SDS model was continuously distracted over this period; the TGR model included two additional distractions following index surgery. Outcomes included differences in rod stress, spinal morphology and iVD stress-shielding. RESULTS: Maximum postoperative von Mises stress was 249MPa for SDS, and 205MPa for TGR. During the 6-month TGR distraction, TGR rod stress increased over two-fold to a maximum stress of 417MPa, compared to a maximum of 262 MPa in the SDS model at 6-month follow-up. During subsequent follow-up periods, TGR rod stress remained consistently higher than stresses in the SDS model. Additional lengthenings in the TGR model led to a smaller residual curve (16.08) and higher T1-S1 growth (359 mm) at 18-month follow-up compared to the SDS model (26.98, 348 mm). During follow-up, there was less stress-shielding of the IVDs in the SDS model, compared to the TGR model. At 18-month follow-up, upper and lower IVD surfaces of the SDS model were loaded more in compression than their TGR counterparts (mean upper: +112 ±â€Š19N; mean lower: +100 ±â€Š17N). CONCLUSION: In the present FEA, TGR treatment resulted in slightly larger curve correction compared to SDS, at the expense of increased IVD stress-shielding and a higher risk of rod fractures. LEVEL OF EVIDENCE: N/A.


Assuntos
Escoliose , Fusão Vertebral , Análise de Elementos Finitos , Humanos , Próteses e Implantes , Escoliose/cirurgia , Coluna Vertebral
2.
Int J Spine Surg ; 15(2): 315-323, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33900989

RESUMO

BACKGROUND: This study evaluates the accuracy, biomechanical profile, and learning curve of the transverse process trajectory technique (TPT) compared to the straightforward (SF) and in-out-in (IOI) techniques. SF and IOI have been used for fixation in the thoracic spine. Although widely used, there are associated learning curves and symptomatic pedicular breaches. We have found the transverse process to be a reproducible pathway into the pedicle. METHODS: Three surgeons with varying experience (experienced [E] with 20 years in practice, surgeon [S] with less than 10 years in practice, and senior resident trainee [T] with no experience with TPT) operated on 8 cadavers. In phase 1, each surgeon instrumented 2 cadavers, alternating between TPT and SF from T1 to T12 (n = 48 total levels). In phase 2, the E and T surgeons instrumented 1 cadaver each, alternating between TPT and IOI. Computed tomography scans were analyzed for accuracy of screw placement, defined as the percentage of placements without critical breaches. Axial pullout and derotational force testing were performed. Statistical analyses include paired t test and analysis of variance with Tukey correction. RESULTS: Overall accuracy of screw placement was comparable between techniques (TPT: 92.7%; SF: 97.2%; IOI: 95.8%; P = .4151). Accuracy by technique did not differ for each individual surgeon (E: P = .7733; S: P = .3475; T: P = .4191) or by experience level by technique (TPT: P = .1127; FH: P = .5979; IOI: P = .5935). Pullout strength was comparable between TPT and SF (571 vs 442 N, P = .3164) but was greater for TPT versus IOI (454 vs 215 N, P = .0156). There was a trend toward improved derotational force for TPT versus SF (1.06 vs 0.93 Nm/degrees, P = .0728) but not for TPT versus IOI (1.36 vs 1.16 Nm/degrees, P = .74). Screw placement time was shortest for E and longest for T for TPT and SF and not different for IOI (TPT: P = .0349; SF: P < .0001; IOI: P = .1787) but did not vary by technique. CONCLUSIONS: We describe the TPT, which uses the transverse process as a corridor through the pedicle. TPT is an accurate method of thoracic pedicle screw placement with potential biomechanical advantages and with acceptable learning curve characteristics. CLINICAL RELEVANCE: This study provides the surgeon with a new trajectory for pedicle screw placement that can be used in clinical practice.

3.
Vet Surg ; 44(4): 459-66, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25412567

RESUMO

OBJECTIVE: To quantify changes in the diameter of the vertebral canal with flexion and extension in the cervical vertebral column. STUDY DESIGN: Cadaveric biomechanical study. SAMPLE POPULATION: Cadaveric canine cervical vertebral column (n = 16 dogs). METHODS: All vertebral columns were evaluated with MRI. Group 1 consisted of 8 normal vertebral columns. Group 2 included 8 vertebral columns with intervertebral disc degeneration. Flexion, extension, compression, and tension were applied to the caudal cervical region (C4-5, C5-6, C6-7). Sagittal vertebral canal diameters (VCD) were obtained by measuring the distance between the ventral and dorsal aspects of vertebral canal. RESULTS: No differences were seen between groups, thus the results are for both groups. Comparison of VCD between flexion and extension with no load revealed a difference of 2.2 mm (28.9%; P < .001). Comparison between neutral position and extension revealed a reduction of 1.5 mm (16.5%; P < .001), whereas comparison between neutral and flexion showed an increase of 0.7 mm (7.7%; P = .001) in VCD. Comparison between neutral with no load and neutral with compression showed a difference of 0.5 mm, with reduction of 5.5% in the vertebral canal (P = .006). Comparison of extension with no load versus extension with tension revealed an increase of 0.7 mm (9.2%) in the vertebral canal (P < .001). CONCLUSIONS: Cervical vertebral canal diameter decreased significantly with extension and increased with flexion. The results support the presence of dynamic impingement possibly playing a role in diseases characterized by vertebral canal stenosis, such as cervical spondylomyelopathy.


Assuntos
Vértebras Cervicais , Doenças do Cão/fisiopatologia , Degeneração do Disco Intervertebral/veterinária , Canal Medular , Animais , Fenômenos Biomecânicos , Cadáver , Doenças do Cão/patologia , Cães , Feminino , Degeneração do Disco Intervertebral/fisiopatologia , Imageamento por Ressonância Magnética/veterinária , Masculino , Amplitude de Movimento Articular
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA