Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
iScience ; 21: 664-680, 2019 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-31733513

RESUMO

Here we describe a proteomic data resource for the NCI-60 cell lines generated by pressure cycling technology and SWATH mass spectrometry. We developed the DIA-expert software to curate and visualize the SWATH data, leading to reproducible detection of over 3,100 SwissProt proteotypic proteins and systematic quantification of pathway activities. Stoichiometric relationships of interacting proteins for DNA replication, repair, the chromatin remodeling NuRD complex, ß-catenin, RNA metabolism, and prefoldins are more evident than that at the mRNA level. The data are available in CellMiner (discover.nci.nih.gov/cellminercdb and discover.nci.nih.gov/cellminer), allowing casual users to test hypotheses and perform integrative, cross-database analyses of multi-omic drug response correlations for over 20,000 drugs. We demonstrate the value of proteome data in predicting drug response for over 240 clinically relevant chemotherapeutic and targeted therapies. In summary, we present a novel proteome resource for the NCI-60, together with relevant software tools, and demonstrate the benefit of proteome analyses.

2.
Cell ; 176(6): 1282-1294.e20, 2019 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-30849372

RESUMO

Multiple signatures of somatic mutations have been identified in cancer genomes. Exome sequences of 1,001 human cancer cell lines and 577 xenografts revealed most common mutational signatures, indicating past activity of the underlying processes, usually in appropriate cancer types. To investigate ongoing patterns of mutational-signature generation, cell lines were cultured for extended periods and subsequently DNA sequenced. Signatures of discontinued exposures, including tobacco smoke and ultraviolet light, were not generated in vitro. Signatures of normal and defective DNA repair and replication continued to be generated at roughly stable mutation rates. Signatures of APOBEC cytidine deaminase DNA-editing exhibited substantial fluctuations in mutation rate over time with episodic bursts of mutations. The initiating factors for the bursts are unclear, although retrotransposon mobilization may contribute. The examined cell lines constitute a resource of live experimental models of mutational processes, which potentially retain patterns of activity and regulation operative in primary human cancers.


Assuntos
Desaminases APOBEC/genética , Neoplasias/genética , Desaminases APOBEC/metabolismo , Linhagem Celular , Linhagem Celular Tumoral , DNA/metabolismo , Análise Mutacional de DNA/métodos , Bases de Dados Genéticas , Exoma , Genoma Humano/genética , Xenoenxertos , Humanos , Mutagênese , Mutação/genética , Taxa de Mutação , Retroelementos , Sequenciamento do Exoma/métodos
3.
J Proteome Res ; 15(6): 1821-9, 2016 06 03.
Artigo em Inglês | MEDLINE | ID: mdl-27098501

RESUMO

The reproducible and efficient extraction of proteins from biopsy samples for quantitative analysis is a critical step in biomarker and translational research. Recently, we described a method consisting of pressure-cycling technology (PCT) and sequential windowed acquisition of all theoretical fragment ions-mass spectrometry (SWATH-MS) for the rapid quantification of thousands of proteins from biopsy-size tissue samples. As an improvement of the method, we have incorporated the PCT-MicroPestle into the PCT-SWATH workflow. The PCT-MicroPestle is a novel, miniaturized, disposable mechanical tissue homogenizer that fits directly into the microTube sample container. We optimized the pressure-cycling conditions for tissue lysis with the PCT-MicroPestle and benchmarked the performance of the system against the conventional PCT-MicroCap method using mouse liver, heart, brain, and human kidney tissues as test samples. The data indicate that the digestion of the PCT-MicroPestle-extracted proteins yielded 20-40% more MS-ready peptide mass from all tissues tested with a comparable reproducibility when compared to the conventional PCT method. Subsequent SWATH-MS analysis identified a higher number of biologically informative proteins from a given sample. In conclusion, we have developed a new device that can be seamlessly integrated into the PCT-SWATH workflow, leading to increased sample throughput and improved reproducibility at both the protein extraction and proteomic analysis levels when applied to the quantitative proteomic analysis of biopsy-level samples.


Assuntos
Proteômica/instrumentação , Animais , Biópsia , Camundongos , Pressão , Proteínas/isolamento & purificação , Proteômica/métodos , Reprodutibilidade dos Testes , Tecnologia , Fluxo de Trabalho
4.
Nat Med ; 21(4): 407-13, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-25730263

RESUMO

Clinical specimens are each inherently unique, limited and nonrenewable. Small samples such as tissue biopsies are often completely consumed after a limited number of analyses. Here we present a method that enables fast and reproducible conversion of a small amount of tissue (approximating the quantity obtained by a biopsy) into a single, permanent digital file representing the mass spectrometry (MS)-measurable proteome of the sample. The method combines pressure cycling technology (PCT) and sequential window acquisition of all theoretical fragment ion spectra (SWATH)-MS. The resulting proteome maps can be analyzed, re-analyzed, compared and mined in silico to detect and quantify specific proteins across multiple samples. We used this method to process and convert 18 biopsy samples from nine patients with renal cell carcinoma into SWATH-MS fragment ion maps. From these proteome maps we detected and quantified more than 2,000 proteins with a high degree of reproducibility across all samples. The measured proteins clearly distinguished tumorous kidney tissues from healthy tissues and differentiated distinct histomorphological kidney cancer subtypes.


Assuntos
Espectrometria de Massas/métodos , Proteômica/métodos , Biópsia , Carcinoma de Células Renais/metabolismo , Humanos , Íons , Rim/metabolismo , Neoplasias Renais/metabolismo , Peptídeos/química , Pressão , Proteoma , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA