J Cardiovasc Dev Dis ; 10(11)2023 Nov 19.
Artigo em Inglês | MEDLINE | ID: mdl-37998527

RESUMO

Transcatheter aortic valve implantation (TAVI) is an established alternative to surgery in patients with symptomatic severe aortic stenosis and has expanded its indications to even low-surgical-risk patients. Conduction abnormalities (CA) and permanent pacemaker (PPM) implantations remain a relatively common finding post TAVI due to the close proximity of the conduction system to the aortic root. New onset left bundle branch block (LBBB) and high-grade atrioventricular block are the most commonly reported CA post TAVI. The overall rate of PPM implantation post TAVI varies and is related to pre- and intra-procedural factors. Therefore, when screening patients for TAVI, Heart Teams should take under consideration the various anatomical, pathophysiological and procedural conditions that predispose to CA and PPM requirement after the procedure. This is particularly important as TAVI is being offered to younger patients with longer life-expectancy. Herein, we highlight the incidence, predictors, impact and management of CA in patients undergoing TAVI.