Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Radiother Oncol ; 94(2): 161-7, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20096947

RESUMO

INTRODUCTION: Magnetic resonance imaging (MRI) provides superior diagnostic accuracy over computed tomography (CT) in oropharyngeal tumours. Precise delineation of the gross tumour volume (GTV) is mandatory in radiotherapy planning when a GTV boost is required. CT volume definition in this regard is poor. We studied the feasibility of using flexible surface (flex-L) coils to obtain MR images for MR-CT fusion to assess the benefit of MRI over CT alone in planning base of tongue tumours. METHODS: Eight patients underwent CT and MRI radiotherapy planning scans with an immobilisation device. Distortion-corrected T1-weighted post-contrast MR scans were fused to contrast-enhanced planning CT scans. GTV, clinical target and planning target volumes (CTV, PTV) and organs at risk (OAR) were delineated on CT, then on MRI with blinding to the CT images. The volumetric and spatial differences between MRI and CT volumes for GTV, CTV, PTV and OAR were compared. MR image distortions due to field inhomogeneity and non-linear gradients were corrected and the need for such correction was evaluated. RESULTS: The mean primary GTV was larger on MRI (22.2 vs. 9.5 cm(3), p=0.05) than CT. The mean primary and nodal GTV (i.e. BOT and macroscopic nodes) was significantly larger on MRI (27.2 vs. 14.4 cm(3), p=0.05). The volume overlap index (VOI) between MRI and CT for the primary was 0.34 suggesting that MRI depicts parts of the primary tumour not detected by CT. There was no significant difference in volume delineation between MR and CT for CTV, PTV, nodal CTV and nodal PTV. MRI volumes for brainstem and spinal cord were significantly smaller due to improved organ definition (p=0.002). Susceptibility and gradient-related distortions were not found to be clinically significant. CONCLUSION: MRI improves the definition of tongue base tumours and neurological structures. The use of MRI is recommended for GTV dose-escalation techniques to provide precise depiction of GTV and improved sparing of spinal cord and brainstem.


Assuntos
Carcinoma de Células Escamosas/patologia , Imageamento por Ressonância Magnética/instrumentação , Planejamento da Radioterapia Assistida por Computador/instrumentação , Neoplasias da Língua/patologia , Carcinoma de Células Escamosas/radioterapia , Meios de Contraste , Estudos de Viabilidade , Gadolínio DTPA , Humanos , Processamento de Imagem Assistida por Computador , Meglumina , Compostos Organometálicos , Tomografia Computadorizada por Raios X , Neoplasias da Língua/radioterapia
2.
Radiother Oncol ; 85(1): 132-7, 2007 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-17470378

RESUMO

BACKGROUND: High dose irradiation of the posterior cervical lymph nodes usually employs applied electron fields to treat the target volume and maintain the spinal cord dose within tolerance. In the light of recent advances in elective lymph node localisation we investigated optimization of field shape and electron energy to treat this target volume. METHODS: In this study, three sequential hypotheses were tested. Firstly, that customization of the electron fields based on the nodal PTV outlined gives better PTV coverage than conventional field delineation. Using the consensus guidelines, customization of the electron field shape was compared to conventional fields based on bony landmarks. Secondly, that selection of electron energy using DVHs for spinal cord and PTV improves the minimum dose to PTV. Electron dose-volume histograms (DVHs) for the PTV, spinal cord and para-vertebral muscles, were generated using the Monte Carlo electron algorithm. These DVHs were used to compare standard vs optimized electron energy calculations. Finally, that combination of field customization and electron energy optimization improves both the minimum and mean doses to PTV compared with current standard practice. RESULTS: Customized electron beam shaping based on the consensus guidelines led to fewer geographical misses than standard field shaping. Customized electron energy calculation led to higher minimum doses to the PTV. Overall, the customization of field shape and energy resulted in an improved mean dose to the PTV (92% vs 83% p=0.02) and a 27% improvement in the minimum dose delivered to the PTV (45% vs 18% p=0.0009). CONCLUSIONS: Optimization of electron field shape and beam energy based on current consensus guidelines led to significant improvement in PTV coverage and may reduce recurrence rates.


Assuntos
Carcinoma de Células Escamosas/radioterapia , Elétrons/uso terapêutico , Neoplasias de Cabeça e Pescoço/radioterapia , Irradiação Linfática/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Pescoço
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA