Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
BMC Anesthesiol ; 24(1): 91, 2024 Mar 04.
Artigo em Inglês | MEDLINE | ID: mdl-38438978

RESUMO

BACKGROUND: Reducing blood loss during excisional surgery in burn patients remains a challenge. Tranexamic acid during surgery can potentially reduce blood loss. The use of tranexamic acid during excisional surgery in burn patients has recently been described in a review and meta-analysis. However, quality assessment on studies included was not performed and this review did not apply independent reviewers. Quality assessment of studies investigating the effectiveness of tranexamic acid in burn patients is crucial before concusions can be drawn. Therefore, we conducted a systematic review and meta-analysis of the literature investigating the effectiveness of tranexamic acid in burn patients undergoing surgery. METHODS: A systematic review and meta-analysis of the literature was conducted. The study was pre-registered in PROSPERO database (CRD42023396183). RESULTS: Five studies including two randomised controlled trials (RCTs) with a total of 303 patients were included. Risk of bias of the included studies was moderate to high. Individual results of the studies were heterogeneous. In three studies of moderate quality the administration of tranexamic acid resulted in a reduction of blood loss per unit excised area, accounting as moderate level of evidence. In two low-quality studies and one moderate quality study the administration of tranexamic acid resulted in a reduction of transfused packed Red Blood Cells (pRBC's), accounting for moderate level of evidence. Postoperative haemoglobin levels were higher after tranexamic acid administration in one study, accounting for insufficient evidence. Meta-analysis pooling overall blood loss from two separate RCTs failed to detect a statistically significant reduction. Substantial heterogeneity was observed. CONCLUSIONS: Moderate level of evidence indicates that tranexamic acid reduces blood loss per unit of excised area and transfusion of packed Red Blood Cells. Results indicate that tranexamic acid can be beneficial in burn patients undergoing surgery. More high-quality research is needed to confirm these results. Future studies should focus on the dosing of tranexamic acid, the administration approaches, and even consider combining these approaches. TRIAL REGISTRATION: PROSPERO: CRD42023396183.


Assuntos
Queimaduras , Ácido Tranexâmico , Humanos , Ácido Tranexâmico/uso terapêutico , Queimaduras/cirurgia , Bases de Dados Factuais , Período Pós-Operatório , Pesquisa Qualitativa , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Burns ; 49(3): 566-572, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36732103

RESUMO

BACKGROUND: Blood loss during burn excisional surgery remains an important factor as it is associated with significant comorbidity, mortality and longer length of stay. Blood loss is, among others, influenced by length of surgery, burn size, excision size and age. Most literature available is aimed at large burns and little research is available for small burns. Therefore, the goal of this study is to investigate blood loss and develop a prediction model to identify patient at risk for blood loss during burn excisional surgery ≤ 10% body surface area. STUDY DESIGN AND METHODS: This retrospective study included adult patients who underwent burn excisional surgery of ≤ 10% body surface area in the period 2013-2018. Duplicates, patients with missing data and delayed surgeries were excluded. Primary outcome was blood loss. A prediction model for per-operative blood loss (>250 ml) was built using a multivariable logistic regression analysis with stepwise backward elimination. Discriminative ability was assessed by the area under the ROC-curve in conjunction with optimism and calibration. RESULTS: In total 269 patients were included for analysis. Median blood loss was 50 ml (0-150) / % body surface area (BSA) excised and 0.28 (0-0.81) ml / cm2. Median burn size was 4% BSA and median excision size was 2% BSA. Blood loss of> 250 ml was present in 39% of patients. The model can predict blood loss> 250 ml based on %BSA excised, length of surgery and ASA-score with an AUC of 0.922 (95% CI 0.883 - 0.949) and an AUC after optimism correction of 0.915. The calibration curve showed an intercept of 0.0 (95% CI -0.36 to 0.36) with a slope of 1.0 (95% CI 0.78-1.22). CONCLUSION: Median blood loss during burn excisional surgery of ≤ 10% BSA is 50 ml / % BSA excised and 0.28 ml / cm2 excised. However, a substantial part of patients is at risk for higher blood loss. The prediction model can predict P(blood loss>250 ml) with an AUC of 0.922, based on expected length of surgery, ASA-score and size of excision. The model can be used to identify patients at risk for significant blood loss (>250 ml).


Assuntos
Queimaduras , Adulto , Humanos , Estudos Retrospectivos , Queimaduras/complicações , Perda Sanguínea Cirúrgica , Curva ROC , Comorbidade
3.
Burns ; 47(1): 127-132, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33082023

RESUMO

BACKGROUND: Hemostasis during burn surgery is difficult to achieve, and high blood loss commonly occurs. Bleeding control measures are limited, and many patients require allogeneic blood transfusions. Cell salvage is a well-known method used to reduce transfusions. However, its evidence in burns is limited. Therefore, this study aimed to examine the feasibility of cell salvage during burn surgery. STUDY DESIGN AND METHODS: A prospective, observational study was conducted with 16 patients (20 measurements) scheduled for major burn surgery. Blood was recovered by washing saturated gauze pads with heparinized saline, which was then processed using the Cell Saver. Erythrocyte concentrate quality was analyzed by measuring hemoglobin, hematocrit, potassium, and free hemoglobin concentration. Microbial contamination was assessed based on cultures at every step of the process. Differences in blood samples were tested using the Student's t-test. RESULTS: The red blood cell mass recovered was 29 ± 11% of the mass lost. Patients' preoperative hemoglobin and hematocrit levels were 10.5 ± 1.8 g/dL and 0.33 ± 0.05 L/L, respectively. The erythrocyte concentrate showed hemoglobin and hematocrit levels of 13.2 ± 3.9 g/dL and 0.40 ± 0.11 L/L thus showing a concentration effect. The potassium level was lower in the erythrocyte concentrate (2.5 ± 1.5 vs. 4.1 ± 0.4 mmol/L, p < 0.05). The free hemoglobin level was low (0.16 ± 0.21 µmol/L). All cultures of the erythrocyte concentrate showed bacterial growth compared to 21% of wound cultures. CONCLUSION: Recovering erythrocytes during burn excisional surgery using cell salvage is possible. Despite strict sterile handling, erythrocyte concentrates of all patients showed bacterial contamination. The consequence of this contamination remains unclear and should be investigated in future studies.


Assuntos
Perda Sanguínea Cirúrgica/fisiopatologia , Corpo Celular/patologia , Reparo do DNA/fisiologia , Eritrócitos/microbiologia , Terapia de Salvação/métodos , Adulto , Idoso , Transfusão de Sangue , Eritrócitos/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA