Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Expo Anal Environ Epidemiol ; 10(6 Pt 2): 776-88, 2000.
Artigo em Inglês | MEDLINE | ID: mdl-11138670

RESUMO

In support of a study to relate developmental and cognitive effects with prenatal exposure to selected environmental toxicants, we developed and applied an analytical method to determine the concentration of two persistent pesticides, hexachlorobenzene (HCB) and p,p'-dichlorodiphenyldichloroethylene (DDE), and 32 specific polychlorinated biphenyl (PCB) congeners in 316 umbilical cords taken in 1986-1987 from women of the Faroe Islands. The analytical method consisted of homogenization of the cords, partitioning, microsilica gel column chromatography for clean-up, and dual-column capillary gas chromatography (DB-5 and DB-1701) with electron capture detection. Several quality control parameters were followed to monitor the performance of the method. Important criteria used before reporting unknown data were the recovery of in vitro-spiked analytes from a bovine umbilical cord (BUC) and the percentage lipid obtained for a Certified Reference Material (CRM)-350 of mackerel oil (MO). Recoveries of analytes that had been spiked at two concentration ranges (0.26-0.95 ng/g whole weight; 0.35-2.42 ng/g whole weight) into bovine cords ranged from 38.5% to 158% and from 50.4% to 145%, respectively, with a median recovery of 77.7%. Measurement of the percentage lipid for CRM-350 ranged from 73.8% to 107% with a median lipid value of 96.0%. The most prevalent analytes detected (%) in unknown umbilical cords were HCB (100), DDE (100), Ballschmiter/Zell PCBs 153 (100), 138 (98), 180 (98), 170 (93), 118 (88), 187 (86), and 146 (83), with corresponding median concentrations (ng/g whole weight) of 0.17, 1.19, 0.38, 0.30, 0.17, 0.11, 0.12, 0.09, and 0.07, respectively. Total PCB--sum of all measurable PCB congeners--had a median concentration of 1.37 ng/g whole weight. The analytes, which were very low in lipid content were also quantified on a lipid-adjusted basis, which provided an analytical challenge in these umbilical cord samples. The gravimetrically measured lipids in the human specimens ranged from 0.01% to 1.43% (median of 0.18%). In the pooled BUCs, our lipid measurements varied from 0.05% to 0.33% with a median value of 0.13%. The utility of using the umbilical cord as a matrix to assess in utero exposure to persistent environmental pollutants, compared with the use of umbilical cord blood or mother's blood, is worthy of debate.


Assuntos
Poluentes Ambientais/análise , Praguicidas/análise , Bifenilos Policlorados/análise , Efeitos Tardios da Exposição Pré-Natal , Cordão Umbilical/química , Adulto , Animais , Bovinos , Cromatografia Gasosa/métodos , Exposição Ambiental , Poluentes Ambientais/efeitos adversos , Feminino , Humanos , Recém-Nascido , Lipídeos/química , Masculino , Praguicidas/efeitos adversos , Bifenilos Policlorados/efeitos adversos , Gravidez , Sensibilidade e Especificidade
2.
J AOAC Int ; 82(1): 177-85, 1999.
Artigo em Inglês | MEDLINE | ID: mdl-10028686

RESUMO

An analytical method is presented for precise identification and quantitation of 29 specific polychlorinated biphenyl (PCB) congeners and 15 chlorinated pesticides in human serum. Analyte surrogates PCB 30, PCB 204, 2,2',4,4',5,5'-hexabromo-biphenyl, perthane, alpha-hexachlorocyclohexane, and dichlorobenzophenone were added to each sample. The serum was extracted with an organic solvent and separated by adsorption chromatography into 3 elution fractions for high-resolution gas chromatographic analysis. Each fraction was analyzed by dual-column capillary chromatography followed by electron capture detection. Two capillary columns, DB-5 and DB-1701, with different polarities were used to increase selectivity for each analyte. Quantitation was performed by selecting 2 sets of calibration standard mixtures and 1,2-dichloronaphthalene as an internal standard. Mean recoveries ranged from 39 to 126% for selected analytes and from 31 to 88% for surrogates. Detection limits for specific congeners and pesticides are reported. Typical chromatographic profiles of calibration standard mixtures, as well as a human sample, are illustrated. Verification of each analyte is assessed, and results of analyses of selected human samples and quality control criteria used to ensure data validity also are presented.


Assuntos
Cromatografia Gasosa/métodos , Inseticidas/sangue , Resíduos de Praguicidas/sangue , Bifenilos Policlorados/sangue , Calibragem , Fracionamento Químico , Humanos
3.
J Anal Toxicol ; 20(7): 528-36, 1996.
Artigo em Inglês | MEDLINE | ID: mdl-8934301

RESUMO

Chlorinated pesticides and polychlorinated biphenyls (PCBs) remain public health concerns because of their unresolved health impact and their persistence in humans. Current epidemiological studies of cancer, non-Hodgkins lymphoma, and endocrine disruption in National Center for Environmental Health (NCEH) laboratories require exposure assessment of many analytes in thousands of people. Previous methods of analyzing pesticides and PCBs in serum have proven inadequate for timely processing of the number of samples required for epidemiological studies. A new method that involves solid-phase extraction (SPE) and cleanup followed by dual-column gas chromatographic separation and electron capture detection has been developed. Nine surrogate compounds were added to the serum prior to sample workup to provide quality assurance for the SPE steps. These surrogates mimic the chemistry of the analytes in the extraction, cleanup, and gas chromatographic analysis steps. To increase selectivity, extracts were injected onto two gas chromatographs with different capillary columns, a DB-1701 and a DB-5. Recoveries of 17 pesticides, 28 PCB congeners, and one polybrominated biphenyl congener ranged from 40 to 80%. Recoveries from this procedure were found to be similar to those from the previously used liquid-liquid extraction method. Correlation of analyte and surrogate recoveries were compared to examine the ruggedness of the technique. The SPE method was found to provide improved sample throughput by a factor of 15.


Assuntos
Cromatografia Gasosa/métodos , Inseticidas/sangue , Bifenilos Policlorados/sangue , Manejo de Espécimes/métodos , Animais , Bovinos , Humanos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
4.
J Assoc Off Anal Chem ; 74(5): 875-7, 1991.
Artigo em Inglês | MEDLINE | ID: mdl-1783595

RESUMO

An analytical method has been developed that uses electron capture/gas-liquid chromatography to determine Mirex in serum containing polychlorinated biphenyls (PCBs) (Aroclor 1260). With this method, 0.2 ppb Mirex can be determined in 4 mL serum that also contains 10 ppb PCBs. The method provides approximately 70% recovery of Mirex at 1.0 and 3.5 ppb. The coefficients of variation are 4.5 and 4.6% at 1.0 and 3.5 ppb, respectively. In a cooperative study with the Ohio Department of Health, the Centers for Disease Control used this method to determine the extent of exposure of Salem, OH, residents to Mirex. Confirmation of Mirex was obtained by using high resolution gas chromatography and high resolution mass spectrometry.


Assuntos
Mirex/sangue , Bifenilos Policlorados/sangue , Cromatografia Gasosa/instrumentação , Cromatografia Gasosa-Espectrometria de Massas , Humanos , Controle de Qualidade , Análise de Regressão , Sensibilidade e Especificidade
5.
J Anal Toxicol ; 14(3): 137-42, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-1695698

RESUMO

A method is presented that can be used to determine the residue level of certain chlorinated pesticides and polychlorinated biphenyls (as Aroclor 1260) in serum. The method involves the following: (1) extraction of denatured serum with organic solvents; (2) elution of the organic extract through micro-Florisil columns to obtain two fractions; (3) acid treatment of the less polar Florisil fraction and its subsequent elution through deactivated silica gel to obtain two fractions; and (4) analysis of all three fractions using gas-liquid chromatography with electron capture detection. The method produced in vitro recoveries for 10 pesticides spiked in the range of 1-10.7 ppb of 50.4% to 121.6%, and in the range of 4.98-21 ppb, recoveries ranged from 47.7 to 112.6. In vivo "recoveries" of Aroclor 1260 averaged 104.8% and 92.3% for concentration levels of approximately 10 and approximately 30 ppb, respectively. The method could not be compared with the more commonly used hexane extraction technique because of the deleterious effect these extracts had on the gas chromatographic system.


Assuntos
Inseticidas/sangue , Silicatos de Magnésio , Bifenilos Policlorados/sangue , Técnicas de Química Analítica/métodos , Cromatografia Gasosa/métodos , DDT/sangue , Diclorodifenil Dicloroetileno/sangue , Exposição Ambiental , Hexaclorobenzeno/sangue , Hexaclorocicloexano/sangue , Hexanos , Humanos , Sílica Gel , Ácido Silícico , Dióxido de Silício
6.
J Anal Toxicol ; 14(3): 143-5, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2165198

RESUMO

Four compounds--2,2', 3,4'-tetrachlorobiphenyl, decachlorodiphenylether, 1,1-dichloro-2,2-bis(p-ethylphenyl)ethane, and dichlorobenzophenone--are recommended for monitoring the within-sample behavior of an analytical method that quantifies chlorinated pesticides and polychlorinated biphenyls (such as Aroclor 1260) in serum using packed column gas chromatography with electron capture detection. Percent recoveries of these surrogates averaged greater than 80%, except with dichlorobenzophenone, which had an average recovery of greater than 70%.


Assuntos
Inseticidas/sangue , Silicatos de Magnésio , Bifenilos Policlorados/sangue , Antineoplásicos/sangue , Benzofenonas/sangue , Técnicas de Química Analítica/métodos , Cromatografia Gasosa/métodos , DDT/sangue , Diclorodifenildicloroetano/análogos & derivados , Diclorodifenildicloroetano/sangue , Éteres Difenil Halogenados , Humanos , Hidrocarbonetos Clorados/sangue , Éteres Fenílicos/sangue , Padrões de Referência , Sílica Gel , Ácido Silícico , Dióxido de Silício
7.
Analyst ; 115(3): 243-51, 1990 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-2109552

RESUMO

Serum for reference pools of in vivo polychlorinated biphenyls (PCBs) was obtained from four goats that had received one dose (100 mg kg-1) of a selected technical Aroclor (AR) (1016, 1242, 1254 or 1260) and were allowed to recover for 30 d. These pools were used to assess the differences in an analytical method that determines and quantifies PCBs using packed-column gas chromatography (PCGC) (quantified on the basis of mean mass percent. data for grouped PCB peaks) and capillary-column gas chromatography (CCGC) (quantified on the basis of percent. composition data for specific congeners). With CCGC, results were statistically significantly different (p less than or equal to 0.0002) from results with PCGC for ARs 1016, 1242 and 1254 but not for AR 1260 (p = 0.23). When comparing these gas chromatographic methods using bovine serum spiked in vitro with the same ARs at 17-25 p.p.b., it was found that the methods were not statistically significantly different for any of the ARs (p = 0.30-0.92). Levels of serum PCB determined by the two methods for 12 persons, divided into two groups according to exposure, were compared using the paired t-test. Group 1 consisted of three persons with dietary and/or environmental exposure; one with dietary and/or environmental exposure in addition to occupational exposure dating back 20 years. Group 2 consisted of eight persons with recent occupational exposure.(ABSTRACT TRUNCATED AT 250 WORDS)


Assuntos
Cromatografia Gasosa/normas , Cabras/sangue , Bifenilos Policlorados/sangue , Animais , Arocloros/sangue , Bovinos , Cromatografia Gasosa/métodos , Exposição Ambiental , Humanos , Controle de Qualidade , Padrões de Referência
8.
J Assoc Off Anal Chem ; 72(4): 649-59, 1989.
Artigo em Inglês | MEDLINE | ID: mdl-2547752

RESUMO

A gas chromatographic-electron capture detection method for determining the concentration of polychlorinated biphenyls (PCBs) as Aroclor 1254 (AR 1254) in serum was evaluated through a 2-phase collaborative study. In Phase I, each collaborator's lot of Woelm silica gel (70-150 mesh) was evaluated for elution and recovery of AR 1254, which had been added in vitro at 25 ng/mL to a serum extract. In Phase II, each collaborator analyzed a series of bovine serum samples that contained the following: (1) in vitro-spiked AR 1254; (2) in vivo AR 1254 and 8 in vitro-spiked chlorinated hydrocarbons; (3) in vivo AR 1254 only; (4) 8 in vitro-spiked chlorinated hydrocarbons only; and (5) neither AR 1254 nor chlorinated hydrocarbons above the detection limit of the method. In Phase I, the average recovery of AR 1254 from silica gel for the 6 collaborators was 87.9 +/- 15.44% (mean +/- 1 SD; N = 18; range = 52.3-105.8%). In Phase II, the analysis of in vitro spikes of AR 1254 in serum at 8.58, 16.8, 41.8, and 84.3 ppb gave mean (means) interlaboratory recoveries of 89.0, 83.3, 79.4, and 76.9%, respectively, with within-laboratory (repeatability) relative standard deviations (RSDr) of 18.8, 20.5, 10.2, and 14.1%, respectively, and among-laboratory (reproducibility) relative standard deviations (RSDR) of 21.5, 21.1, 14.6, and 20.8%, respectively. The determination of in vivo AR 1254 in samples containing approximately 10, 25, 50, and 100 ng/mL of AR 1254 resulted in interlaboratory means of 10, 22, 39, and 79 ng/mL, respectively, with RSDr = 6.7, 9.7, 6.4, and 5.8%, respectively, and RSDR = 20.6, 16.0, 10.9, and 10.3%, respectively. The precision of the method for incurred AR 1254 showed a maximum RSDr of less than 10% and a maximum RSDR of less than 21% for a concentration range of 10-100 ng/mL. The accuracy of the method as demonstrated by the mean recovery of in vitro-spiked AR 1254 over a concentration range of 8.58-843 ng/mL was 82.2%. The method has been approved interim official first action.


Assuntos
Arocloros/sangue , Bifenilos Policlorados/sangue , Animais , Bovinos , Cromatografia Gasosa , Indicadores e Reagentes , Sílica Gel , Dióxido de Silício , Sulfatos
9.
J Assoc Off Anal Chem ; 66(1): 32-9, 1983 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-6402483

RESUMO

A method is proposed for concurrently determining the levels of multiple intact exogenous compounds in serum, particularly polychlorinated biphenyls (PCBs) as Aroclor (AR) 1254 and chlorinated hydrocarbons (CHs). Bovine serum pools containing in vivo-bound PCBs (as AR 1254) and in vitro-spiked CHs are used to evaluate the method, which encompasses serum denaturation with methanol, mixed solvent extraction, multiple solvent fractionation from activated silica gel, and determination by electron capture gas-liquid chromatography. Mean recoveries of the in vitro-spiked 9 CHs at levels of 2.0-29.1 ppb ranged from 52.8 to 98.4% from trial environmental pools; mean recoveries of the in vivo-bound PCBs (as AR 1254) were 114.1 and 92.6% at levels of 10 and 50 ppb, respectively.


Assuntos
Hidrocarbonetos Clorados/sangue , Bifenilos Policlorados/sangue , Animais , Arocloros/sangue , Bovinos , Cromatografia Gasosa
10.
J Natl Cancer Inst ; 66(3): 535-42, 1981 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-6259400

RESUMO

Noninbred Sherman strain rats were given the polybrominated biphenyl mixture Firemaster FF-1 (PBB). Rats given a single dose of 1,000 mg PBB/kg or 12 doses of 100 mg PBB/kg body weight in corn oil by gavage had final (when less than or equal to 26 mo old) liver PBB concentrations of 17.1 and 34.8 mg/kg (wet wt), respectively. The respective incidence of hepatocellular carcinomas was 41.4 and 67.8%. No difference in PBB concentrations was found between hepatocellular carcinomas and surrounding liver tissue. In addition, most livers of PBB-dosed rats had adenofibrosis of the liver. Livers of controls were essentially normal. Rats given a single dose of 200 mg PBB/kg as above had a 31.2% incidence of neoplastic nodules, whereas none were seen in the controls. The mean PBB concentrations (when 26 mo old) were 2.68 mg/kg in liver, 244 mg/kg in adipose tissue, and 0.22 mg/kg in blood.


Assuntos
Compostos de Bifenilo/toxicidade , Neoplasias Hepáticas Experimentais/induzido quimicamente , Neoplasias Hepáticas/induzido quimicamente , Bifenil Polibromatos/toxicidade , Tecido Adiposo/metabolismo , Animais , Peso Corporal/efeitos dos fármacos , Feminino , Fígado/efeitos dos fármacos , Fígado/metabolismo , Neoplasias Hepáticas/patologia , Neoplasias Hepáticas Experimentais/patologia , Neoplasias Hipofisárias/induzido quimicamente , Bifenil Polibromatos/metabolismo , Ratos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA