Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Eur J Vasc Endovasc Surg ; 62(2): 187-192, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33608205

RESUMO

OBJECTIVE: Open repair surgery (ORS) for an abdominal aortic aneurysm (AAA) remains an important treatment option, but the incidence of para-anastomotic aneurysms is unclear. The purpose of this study was to estimate the incidence of para-anastomotic aneurysms and reveal secondary complications through routine annual computed tomography (CT) imaging. METHODS: One hundred and forty-seven patients who underwent ORS for AAA between January 2006 and December 2015 and received routine CT imaging surveillance were enrolled. RESULTS: The follow up period was 7.1 ± 2.7 years. The total follow up time of all patients was 1 041.1 years, and 958 CT images were collected (0.92 CT scans/year/patient). A proximal para-anastomotic aneurysm was detected in five patients (3.4%). Four of the five patients had aneurysmal dilation at the initial ORS (proximal diameter >25 mm), which enlarged during follow up; thus, a de novo proximal para-anastomotic aneurysm was observed in one patient (0.7%). The time between surgery and the diagnosis of all proximal para-anastomotic aneurysms was 5.7 ± 1.4 years, and the de novo proximal para-anastomotic aneurysm was detected at 11.8 years. The incidence of all para-anastomotic aneurysms at five and 10 years was 2.2% and 3.6%, and the incidence of the de novo para-anastomotic aneurysm was 0% at five and 10 years. Nine synchronous thoracic aortic aneurysms (TAAs) and seven metachronous TAAs were detected, and 16 patients (10.9%) had a TAA. Neoplasms were detected in 18 of 147 patients (12.2%), and the most dominant neoplasm was lung cancer. CONCLUSION: The incidence of para-anastomotic aneurysms was low; thus, abdominal and pelvic CT imaging every five years may be sufficient and consistent with the current AAA guidelines. In contrast, TAAs were diagnosed in a high percentage of patients, and based on these observations, routine CT imaging should be expanded to include the chest.


Assuntos
Aorta Abdominal/cirurgia , Aneurisma da Aorta Abdominal/epidemiologia , Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/epidemiologia , Neoplasias Pulmonares/epidemiologia , Idoso , Anastomose Cirúrgica , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Comorbidade , Feminino , Seguimentos , Humanos , Incidência , Japão/epidemiologia , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Modelos de Riscos Proporcionais , Estudos Retrospectivos , Fatores de Risco , Tomografia Computadorizada por Raios X
2.
Kyobu Geka ; 68(12): 961-6, 2015 Nov.
Artigo em Japonês | MEDLINE | ID: mdl-26555907

RESUMO

BACKGROUND: In Guideline for Surgical and Interventional Treatment of Valvular Heart Disease, revised by Japanese Circulation Society in 2012, mitral valve replacement (MVR) with bioprosthesis is class II b recommendation for patients aged 70 years or older who have no risk factors for thromboembolism. The aim of this study was to evaluate the early postoperative surgical outcomes and the hemodynamic performance with the Epic mitral bioprosthesis. METHODS: Twenty-six consecutive patients underwent MVR with Epic mitral bioprostesis at Tohoku University Hospital between April 2011 and July 2014. Twenty-five cases of 26 were evaluated their hemodynamics at discharge, and of which 19 cases of 26 were evaluated at the outpatient clinic during follow-up period. RESULTS: There was 1 hospital death. Long-term mortality or reoperation for any valve abnormality was not observed in the median follow-up of 23.9 ± 11.3 months. Hemodynamic date at discharge obtained by transthoracic echocardiography included mean hemodynamics of mitral valve bioprosthesis as below. Effective orifice area (EOA):2.44 ± 0.62 cm², peak mitral pressure gradient (pMPG):15.8 ± 5.3 mmHg, mean mitral pressure gradient(mMPG):7.2 ± 2.4 mmHg. Hemodynamic parameters at follow-up were found to be stable as EOA:2.25 ± 0.64 cm², pMPG:17.3 ± 5.7 mmHg, mMPG:6.2 ± 2.3 mmHg, respectively. CONCLUSION: We have attempted to elucidate our preliminary postoperative outcomes and hemodynamics after MVR with Epic mitral bioprosthesis. These in vivo hemodynamic data can serves a clinical reference.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Implante de Prótese de Valva Cardíaca , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA