Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 15 de 15
Filtrar
1.
Sensors (Basel) ; 21(23)2021 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-34883846

RESUMO

RF power is broadly available in both urban and semi-urban areas and thus exhibits as a promising candidate for ambient energy scavenging sources. In this research, a high-efficiency quad-band rectenna is designed for ambient RF wireless energy scavenging over the frequency range from 0.8 to 2.5 GHz. Firstly, the detailed characteristics (i.e., available frequency bands and associated power density levels) of the ambient RF power are studied and analyzed. The data (i.e., RF survey results) are then applied to aid the design of a new quad-band RF harvester. A newly designed impedance matching network (IMN) with an additional L-network in a third-branch of dual-port rectifier circuit is familiarized to increase the performance and RF-to-DC conversion efficiency of the harvester with comparatively very low input RF power density levels. A dual-polarized multi-frequency bow-tie antenna is designed, which has a wide bandwidth (BW) and is miniature in size. The dual cross planer structure internal triangular shape and co-axial feeding are used to decrease the size and enhance the antenna performance. Consequently, the suggested RF harvester is designed to cover all available frequency bands, including part of most mobile phone and wireless local area network (WLAN) bands in Malaysia, while the optimum resistance value for maximum dc rectification efficiency (up to 48%) is from 1 to 10 kΩ. The measurement result in the ambient environment (i.e., both indoor and outdoor) depicts that the new harvester is able to harvest dc voltage of 124.3 and 191.0 mV, respectively, which can be used for low power sensors and wireless applications.

2.
Fluids Barriers CNS ; 18(1): 52, 2021 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-34852829

RESUMO

Contemporary biomarker collection techniques in blood and cerebrospinal fluid have to date offered only modest clinical insights into neurologic diseases such as epilepsy and glioma. Conversely, the collection of human electroencephalography (EEG) data has long been the standard of care in these patients, enabling individualized insights for therapy and revealing fundamental principles of human neurophysiology. Increasing interest exists in simultaneously measuring neurochemical biomarkers and electrophysiological data to enhance our understanding of human disease mechanisms. This review compares microdialysis, microperfusion, and implanted EEG probe architectures and performance parameters. Invasive consequences of probe implantation are also investigated along with the functional impact of biofouling. Finally, previously developed microdialysis electrodes and microperfusion electrodes are reviewed in preclinical and clinical settings. Critically, current and precedent microdialysis and microperfusion probes lack the ability to collect neurochemical data that is spatially and temporally coincident with EEG data derived from depth electrodes. This ultimately limits diagnostic and therapeutic progress in epilepsy and glioma research. However, this gap also provides a unique opportunity to create a dual-sensing technology that will provide unprecedented insights into the pathogenic mechanisms of human neurologic disease.


Assuntos
Biomarcadores , Eletrocorticografia , Microdiálise , Doenças do Sistema Nervoso/diagnóstico , Monitorização Neurofisiológica , Humanos , Microdiálise/instrumentação , Microdiálise/métodos , Monitorização Neurofisiológica/instrumentação , Monitorização Neurofisiológica/métodos
3.
Sci Rep ; 11(1): 11901, 2021 06 07.
Artigo em Inglês | MEDLINE | ID: mdl-34099777

RESUMO

The COVID-19 pandemic has led to the rapid adoption and rollout of thermal camera-based Infrared Thermography (IRT) systems for fever detection. These systems use facial infrared emissions to detect individuals exhibiting an elevated core-body temperature, which is present in many symptomatic presentations of Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2). Despite the rollout of these systems, there is little independent research supporting their efficacy. The primary objective of this study was to assess the precision and accuracy of IRT screening solutions in a real-world scenario. The method used was a single-centre, observational study investigating the agreement of three IRT systems compared to digital oral thermometer measurements of body temperature. Over 5 days, 107 measurements were taken from individuals wearing facial masks. During each entry, two measurements of the subject's body temperature were made from each system to allow for the evaluation of the measurement precision, followed by an oral thermometer measurement. Each participant also answered a short demographic survey. This study found that the precision of the IRT systems was wider than 0.3 °C claimed accuracy of two of the systems. This study also found that the IRT measurements were only weakly correlated to those of the oral temperature. Additionally, it was found that demographic characteristics (age, gender, and mask-type) impacted the measurement error. This study indicates that using IRT systems in front-line scenarios poses a potential risk, where a lack of measurement accuracy could possibly allow febrile individuals to pass through undetected. Further research is required into methods which could increase accuracy and improve the techniques viability.


Assuntos
Temperatura Corporal/fisiologia , COVID-19/prevenção & controle , SARS-CoV-2/patogenicidade , Temperatura Cutânea/fisiologia , COVID-19/diagnóstico , Humanos , Raios Infravermelhos , Programas de Rastreamento/métodos , Termômetros
4.
Materials (Basel) ; 14(3)2021 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-33498828

RESUMO

The inhomogeneity of the resistance of conducting polypyrrole-coated nylon-Lycra and polyester (PET) fabrics and its effects on surface temperature were investigated through a systematic experimental and numerical work including the optimization of coating conditions to determine the lowest resistivity conductive fabrics and establish a correlation between the fabrication conditions and the efficiency and uniformity of Joule heating in conductive textiles. For this purpose, the effects of plasma pre-treatment and molar concentration analysis of the dopant anthraquinone sulfonic acid (AQSA), oxidant ferric chloride, and monomer pyrrole was carried out to establish the conditions to determine the sample with the lowest electrical resistance for generating heat and model the experiments using the finite element modeling (FEM). Both PET and nylon-Lycra underwent atmospheric plasma treatment to functionalize the fabric surface to improve the binding of the polymer and obtain coatings with reduced resistance. Both fabrics were compared in terms of average electrical resistance for both plasma treated and untreated samples. The plasma treatment induced deep black coatings with lower resistance. Then, heat-generating experiments were conducted on the polypyrrole (PPy) coated fabrics with the lowest resistance using a variable power supply to study the distribution and maximum value of the temperature. The joule heating model was developed to predict the heating of the conductive fabrics via finite element analysis. The model was based on the measured electrical resistance at different zones of the coated fabrics. It was shown that, when the fabric was backed with neoprene insulation, it would heat up quicker and more evenly. The average electrical resistance of the PPy-PET sample used was 190 Ω, and a maximum temperature reading of 43 °C was recorded. The model results exhibited good agreement with thermal camera data.

5.
J Neuroeng Rehabil ; 16(1): 126, 2019 10 29.
Artigo em Inglês | MEDLINE | ID: mdl-31665058

RESUMO

Epilepsy affects nearly 1% of the world's population. A third of epilepsy patients suffer from a kind of epilepsy that cannot be controlled by current medications. For those where surgery is not an option, neurostimulation may be the only alternative to bring relief, improve quality of life, and avoid secondary injury to these patients. Until recently, open loop neurostimulation was the only alternative for these patients. However, for those whose epilepsy is applicable, the medical approval of the responsive neural stimulation and the closed loop vagal nerve stimulation systems have been a step forward in the battle against uncontrolled epilepsy. Nonetheless, improvements can be made to the existing systems and alternative systems can be developed to further improve the quality of life of sufferers of the debilitating condition. In this paper, we first present a brief overview of epilepsy as a disease. Next, we look at the current state of biomarker research in respect to sensing and predicting epileptic seizures. Then, we present the current state of open loop neural stimulation systems. We follow this by investigating the currently approved, and some of the recent experimental, closed loop systems documented in the literature. Finally, we provide discussions on the current state of neural stimulation systems for controlling epilepsy, and directions for future studies.


Assuntos
Epilepsia Resistente a Medicamentos/terapia , Terapia por Estimulação Elétrica/instrumentação , Terapia por Estimulação Elétrica/métodos , Biomarcadores , Estimulação Encefálica Profunda , Epilepsia Resistente a Medicamentos/epidemiologia , Humanos
6.
J Neural Eng ; 15(6): 066003, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30124202

RESUMO

OBJECTIVE: Stereotactic frame systems are the gold-standard for stereotactic surgeries, such as implantation of deep brain stimulation (DBS) devices for treatment of medically resistant neurologic and psychiatric disorders. However, frame-based systems require that the patient is awake with a stereotactic frame affixed to their head for the duration of the surgical planning and implantation of the DBS electrodes. While frameless systems are increasingly available, a reusable re-attachable frame system provides unique benefits. As such, we created a novel reusable MRI-compatible stereotactic frame system that maintains clinical accuracy through the detachment and reattachment of its stereotactic devices used for MRI-guided neuronavigation. APPROACH: We designed a reusable arc-centered frame system that includes MRI-compatible anchoring skull screws for detachment and re-attachment of its stereotactic devices. We validated the stability and accuracy of our system through phantom, in vivo mock-human porcine DBS-model and human cadaver testing. MAIN RESULTS: Phantom testing achieved a root mean square error (RMSE) of 0.94 ± 0.23 mm between the ground truth and the frame-targeted coordinates; and achieved an RMSE of 1.11 ± 0.40 mm and 1.33 ± 0.38 mm between the ground truth and the CT- and MRI-targeted coordinates, respectively. In vivo and cadaver testing achieved a combined 3D Euclidean localization error of 1.85 ± 0.36 mm (p < 0.03) between the pre-operative MRI-guided placement and the post-operative CT-guided confirmation of the DBS electrode. SIGNIFICANCE: Our system demonstrated consistent clinical accuracy that is comparable to conventional frame and frameless stereotactic systems. Our frame system is the first to demonstrate accurate relocation of stereotactic frame devices during in vivo MRI-guided DBS surgical procedures. As such, this reusable and re-attachable MRI-compatible system is expected to enable more complex, chronic neuromodulation experiments, and lead to a clinically available re-attachable frame that is expected to decrease patient discomfort and costs of DBS surgery.


Assuntos
Imageamento por Ressonância Magnética/instrumentação , Neuronavegação/instrumentação , Técnicas Estereotáxicas/instrumentação , Animais , Parafusos Ósseos , Cadáver , Estimulação Encefálica Profunda , Reutilização de Equipamento , Humanos , Imageamento por Ressonância Magnética/métodos , Neuronavegação/métodos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Cirurgia Assistida por Computador/instrumentação , Suínos , Tomografia Computadorizada por Raios X
7.
IEEE Access ; 7: 230-244, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30976472

RESUMO

Most of the current closed-loop DBS devices use a single biomarker in their feedback loop which may limit their performance and applications. This paper presents design, fabrication, and validation of a programmable multi-biomarker neural sensor which can be integrated into closed-loop DBS devices. The device is capable of sensing a combination of low-frequency (7-45 Hz), and high-frequency (200-1000 Hz) neural signals. The signals can be amplified with a digitally programmable gain within the range 50-100 dB. The neural signals can be stored into a local memory for processing and validation. The sensing and storage functions are implemented via a combination of analog and digital circuits involving preamplifiers, filters, programmable post-amplifiers, microcontroller, digital potentiometer, and flash memory. The device is fabricated, and its performance is validated through: (i) bench tests using sinusoidal and pre-recorded neural signals, (ii) in-vitro tests using pre-recorded neural signals in saline solution, and (iii) in-vivo tests by recording neural signals from freely-moving laboratory mice. The animals were implanted with a PlasticsOne electrode, and recording was conducted after recovery from the electrode implantation surgery. The experimental results are presented and discussed confirming the successful operation of the device. The size and weight of the device enable tetherless back-mountable use in pre-clinical trials.

8.
Front Hum Neurosci ; 10: 102, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27014033

RESUMO

Deep brain stimulation (DBS), a surgical technique to treat certain neurologic and psychiatric conditions, relies on pre-determined stimulation parameters in an open-loop configuration. The major advancement in DBS devices is a closed-loop system that uses neurophysiologic feedback to dynamically adjust stimulation frequency and amplitude. Stimulation-driven neurochemical release can be measured by fast-scan cyclic voltammetry (FSCV), but existing FSCV electrodes rely on carbon fiber, which degrades quickly during use and is therefore unsuitable for chronic neurochemical recording. To address this issue, we developed durable, synthetic boron-doped diamond-based electrodes capable of measuring neurochemical release in humans. Compared to carbon fiber electrodes, they were more than two orders-of-magnitude more physically-robust and demonstrated longevity in vitro without deterioration. Applied for the first time in humans, diamond electrode recordings from thalamic targets in patients (n = 4) undergoing DBS for tremor produced signals consistent with adenosine release at a sensitivity comparable to carbon fiber electrodes. (Clinical trials # NCT01705301).

9.
Materials (Basel) ; 9(7)2016 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-28773729

RESUMO

Complex permittivity of conducting polypyrrole (PPy)-coated Nylon-Lycra textiles is measured using a free space transmission measurement technique over the frequency range of 1-18 GHz. The aging of microwave dielectric properties and reflection, transmission and absorption for a period of 18 months is demonstrated. PPy-coated fabrics are shown to be lossy over the full frequency range. The levels of absorption are shown to be higher than reflection in the tested samples. This is attributed to the relatively high resistivity of the PPy-coated fabrics. Both the dopant concentration and polymerisation time affect the total shielding effectiveness and microwave aging behaviour. Distinguishing either of these two factors as being exclusively the dominant mechanism of shielding effectiveness is shown to be difficult. It is observed that the PPy-coated Nylon-Lycra samples with a p-toluene sulfonic acid (pTSA) concentration of 0.015 M and polymerisation times of 60 min and 180 min have 37% and 26% decrease in total transmission loss, respectively, upon aging for 72 weeks at room temperature (20 °C, 65% Relative humidity (RH)). The concentration of the dopant also influences the microwave aging behaviour of the PPy-coated fabrics. The samples with a higher dopant concentration of 0.027 mol/L pTSA are shown to have a transmission loss of 32.6% and 16.5% for short and long polymerisation times, respectively, when aged for 72 weeks. The microwave properties exhibit better stability with high dopant concentration and/or longer polymerization times. High pTSA dopant concentrations and/or longer polymerisation times result in high microwave insertion loss and are more effective in reducing the transmission and also increasing the longevity of the electrical properties.

10.
Med Eng Phys ; 37(10): 1020-6, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26318799

RESUMO

This paper presents the development of an energy harvesting circuit for use with a head-mountable deep brain stimulation (DBS) device. It consists of a circular planar inverted-F antenna (PIFA) and a Schottky diode-based Cockcroft-Walton 4-voltage rectifier. The PIFA has the volume of π × 10(2) × 1.5 mm(3), resonance frequency of 915 MHz, and bandwidth of 16 MHz (909-925 MHz) at a return loss of -10 dB. The rectifier offers maximum efficiency of 78% for the input power of -5 dBm at a 5 kΩ load resistance. The developed rectenna operates efficiently at 915 MHz for the input power within -15 dBm to +5 dBm. For operating a DBS device, the DC voltage of 2 V is recorded from the rectenna terminal at a distance of 55 cm away from a 26.77 dBm transmitter in free space. An in-vitro test of the DBS device is presented.


Assuntos
Estimulação Encefálica Profunda/instrumentação , Equipamentos e Provisões Elétricas , Ondas de Rádio , Animais , Desenho de Equipamento , Cabeça , Camundongos , Modelos Animais
11.
Theranostics ; 5(10): 1083-97, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26199647

RESUMO

Insufficient penetration of therapeutic agents into tumor tissues results in inadequate drug distribution and lower intracellular concentration of drugs, leading to the increase of drug resistance and resultant failure of cancer treatment. Targeted drug delivery to solid tumors followed by complete drug penetration and durable retention will significantly improve clinical outcomes of cancer therapy. Monoclonal antibodies have been commonly used in clinic for cancer treatment, but their limitation of penetrating into tumor tissues still remains because of their large size. Aptamers, as "chemical antibodies", are 15-20 times smaller than antibodies. To explore whether aptamers are superior to antibodies in terms of tumor penetration, we carried out the first comprehensive study to compare the performance of an EpCAM aptamer with an EpCAM antibody in theranostic applications. Penetration and retention were studied in in vitro three-dimensional tumorspheres, in vivo live animal imaging and mouse colorectal cancer xenograft model. We found that the EpCAM aptamer can not only effectively penetrate into the tumorsphere cores but can also be retained by tumor sphere cells for at least 24 h, while limited tumor penetration by EpCAM antibody was observed after 4 h incubation. As observed from in vivo live animal imaging, EpCAM aptamers displayed a maximum tumor uptake at around 10 min followed by a rapid clearance after 80 min, while the signal of peak uptake and disappearance of antibody appeared at 3 h and 6 h after intravenous injection, respectively. The signal of PEGylated EpCAM aptamers in xenograft tumors was sustained for 26 h, which was 4.3-fold longer than that of the EpCAM antibody. Consistently, there were 1.67-fold and 6.6-fold higher accumulation of PEGylated aptamer in xenograft tumors than that of antibody, at 3 h and 24 h after intravenous administration, respectively. In addition, the aptamer achieved at least a 4-time better tumor penetration in xenograft tumors than that of the antibody at a 200 µm distances from the blood vessels 3 h after intravenous injection. Taken together, these data indicate that aptmers are superior to antibodies in cancer theranostics due to their better tumor penetration, more homogeneous distribution and longer retention in tumor sites. Thus, aptamers are promising agents for targeted tumor therapeutics and molecular imaging.


Assuntos
Aptâmeros de Nucleotídeos/farmacocinética , Sistemas de Liberação de Medicamentos/métodos , Nanomedicina Teranóstica/métodos , Animais , Anticorpos Monoclonais/química , Anticorpos Monoclonais/farmacocinética , Aptâmeros de Nucleotídeos/química , Linhagem Celular Tumoral , Sistemas de Liberação de Medicamentos/instrumentação , Feminino , Humanos , Camundongos , Camundongos Endogâmicos NOD , Camundongos SCID , Nanomedicina Teranóstica/instrumentação , Distribuição Tecidual , Transplante Heterólogo
12.
Theranostics ; 5(1): 23-42, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25553096

RESUMO

Conventional anticancer therapies, such as chemo- and/or radio-therapy are often unable to completely eradicate cancers due to abnormal tumor microenvironment, as well as increased drug/radiation resistance. More effective therapeutic strategies for overcoming these obstacles are urgently in demand. Aptamers, as chemical antibodies that bind to targets with high affinity and specificity, are a promising new and novel agent for both cancer diagnostic and therapeutic applications. Aptamer-based cancer cell targeting facilitates the development of active targeting in which aptamer-mediated drug delivery could provide promising anticancer outcomes. This review is to update the current progress of aptamer-based cancer diagnosis and aptamer-mediated active targeting for cancer therapy in vivo, exploring the potential of this novel form of targeted cancer therapy.


Assuntos
Antineoplásicos/uso terapêutico , Aptâmeros de Nucleotídeos/uso terapêutico , Sistemas de Liberação de Medicamentos/métodos , Neoplasias/diagnóstico , Neoplasias/tratamento farmacológico , Pesquisa Biomédica/tendências , Humanos
13.
Int J Comput Assist Radiol Surg ; 10(7): 1003-16, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25418867

RESUMO

PURPOSE: Accurate detection of depression at an individual level using structural magnetic resonance imaging (sMRI) remains a challenge. Brain volumetric changes at a structural level appear to have importance in depression biomarkers studies. An automated algorithm is developed to select brain sMRI volumetric features for the detection of depression. METHODS: A feature selection (FS) algorithm called degree of contribution (DoC) is developed for selection of sMRI volumetric features. This algorithm uses an ensemble approach to determine the degree of contribution in detection of major depressive disorder. The DoC is the score of feature importance used for feature ranking. The algorithm involves four stages: feature ranking, subset generation, subset evaluation, and DoC analysis. The performance of DoC is evaluated on the Duke University Multi-site Imaging Research in the Analysis of Depression sMRI dataset. The dataset consists of 115 brain sMRI scans of 88 healthy controls and 27 depressed subjects. Forty-four sMRI volumetric features are used in the evaluation. RESULTS: The DoC score of forty-four features was determined as the accuracy threshold (Acc_Thresh) was varied. The DoC performance was compared with that of four existing FS algorithms. At all defined Acc_Threshs, DoC outperformed the four examined FS algorithms for the average classification score and the maximum classification score. CONCLUSION: DoC has a good ability to generate reduced-size subsets of important features that could yield high classification accuracy. Based on the DoC score, the most discriminant volumetric features are those from the left-brain region.


Assuntos
Encéfalo/patologia , Transtorno Depressivo Maior/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Depressão , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reconhecimento Automatizado de Padrão/métodos
14.
Biomicrofluidics ; 7(5): 51502, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24273628

RESUMO

Microfluidic technology provides precise, controlled-environment, cost-effective, compact, integrated, and high-throughput microsystems that are promising substitutes for conventional biological laboratory methods. In recent years, microfluidic cell culture devices have been used for applications such as tissue engineering, diagnostics, drug screening, immunology, cancer studies, stem cell proliferation and differentiation, and neurite guidance. Microfluidic technology allows dynamic cell culture in microperfusion systems to deliver continuous nutrient supplies for long term cell culture. It offers many opportunities to mimic the cell-cell and cell-extracellular matrix interactions of tissues by creating gradient concentrations of biochemical signals such as growth factors, chemokines, and hormones. Other applications of cell cultivation in microfluidic systems include high resolution cell patterning on a modified substrate with adhesive patterns and the reconstruction of complicated tissue architectures. In this review, recent advances in microfluidic platforms for cell culturing and proliferation, for both simple monolayer (2D) cell seeding processes and 3D configurations as accurate models of in vivo conditions, are examined.

15.
Materials (Basel) ; 6(8): 3482-3493, 2013 Aug 13.
Artigo em Inglês | MEDLINE | ID: mdl-28811447

RESUMO

Improvement of the binding of polypyrrole with PVDF (polyvinylidene fluoride) thin film using low pressure plasma was studied. The effects of various plasma gases i.e., Ar, O2 and Ar + O2 gases on surface roughness, surface chemistry and hydrophilicity were noted. The topographical change of the PVDF film was observed by means of scanning electron microscopy and chemical changes by X-ray photoelectron spectroscopy, with adhesion of polypyrrole (PPy) by abrasion tests and sheet resistance measurements. Results showed that the increase in roughness and surface functionalization by oxygen functional groups contributed to improved adhesion and Ar + O2 plasma gave better adhesion.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA