Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Int J Clin Pract ; 63(1): 63-70, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19125994

RESUMO

AIMS: The deleterious nature of peripheral arterial disease (PAD) is compounded by a status of underdiagnosed and undertreated disease. We evaluated the prevalence and predictive factors of PAD in high-risk patients using the ankle-brachial index (ABI). METHODS: The ABI was measured by general practitioners in France (May 2005-February 2006) in 5679 adults aged 55 years or older and considered at high risk. The primary outcome was prevalence of PAD (ABI strictly below 0.90). RESULTS: In all, 21.3% patients had signs or symptoms suggestive of PAD, 42.1% had previous history of atherothrombotic disease and 36.6% had two or more cardiovascular risk factors. Prevalence of PAD was 27.8% overall, ranging from 10.4% in patients with cardiovascular risk factors only to approximately 38% in each other subgroup. Prevalence differed depending on the localization of atherothrombotic events: it was 57.1-75.0% in patients with past history of symptomatic PAD; 24.6-31.1% in those who had experienced cerebrovascular and/or coronary events. Regarding the classical cardiovascular risk factors, PAD was more frequent when smoking and hypercholesterolemia history were reported. PAD prevalence was also higher in patients with history of abdominal aortic aneurysm, renal hypertension or atherothrombotic event. Intermittent claudication, lack of one pulse in the lower limbs, smoking, diabetes and renovascular hypertension were the main factors predictive of low ABI. CONCLUSIONS: Given the elevated prevalence of PAD in high-risk patients and easiness of diagnosis using ABI in primary care, undoubtedly better awareness would help preserve individual cardiovascular health and achieve public health goals.


Assuntos
Índice Tornozelo-Braço , Doenças Cardiovasculares/prevenção & controle , Doenças Vasculares Periféricas/diagnóstico , Idoso , Doenças Cardiovasculares/epidemiologia , Métodos Epidemiológicos , Medicina de Família e Comunidade , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Doenças Vasculares Periféricas/epidemiologia , Prevalência , Fatores de Risco
2.
Arch Mal Coeur Vaiss ; 99 Spec No 1(1): 43-8, 2006 Jan.
Artigo em Francês | MEDLINE | ID: mdl-16479963

RESUMO

It is illusory to think that one year is long enough to establish all the truths that will guide our clinical practice in vascular medicine. On the contrary, one year was long enough to contradict what the preceding twelve months had set out to demonstrate. Consequently, promising trials in the treatment of abdominal aortic aneurysms by endoprostheses have been the object of contradictory debate with regards to the long-term benefits. In fundamental research, circulating progenitors of endothelial cells have been shown to be a marker of atherosclerosis, but is it a better marker than LDL-cholesterol values? The demonstration that these progenitors are of value in the treatment of essential ischaemia of the lower limbs is awaited. Finally, ximelagatran, a direct thrombin antagonist, seemed to have all the qualities of an ideal anticoagulant: easy to use, safe... until the report of raised hepatic enzymes, the clinical relevance of which remains to be determined. In the good news section: the Systolic Pressure Index, an unquestioned marker of arterial disease. Its reduction was known to be correlated with the prevalence of cardiovascular complications. However, it has now been shown that an increase in the index is also associated with cardiovascular complications, a real U-shaped curve. Renal arterial stenosis should be considered in patients with left ventricular failure presenting with flash pulmonary oedema. In the absence of cardiac pathology, BNP would seem to be a good biological marker of haemodynamically significant renal arterial stenosis. Finally, should superficial femoral artery stenosis be treated by an active stent. To date, there is no formal proof.


Assuntos
Doenças Vasculares/terapia , Inibidores da Angiogênese/uso terapêutico , Anticoagulantes/uso terapêutico , Ecocardiografia Doppler em Cores , Humanos , Editoração/tendências , Stents , Doenças Vasculares/diagnóstico por imagem
3.
J Endovasc Surg ; 6(4): 321-31, 1999 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-10893133

RESUMO

PURPOSE: To study the feasibility and safety of carotid angioplasty and stenting using a new cerebral protection device that temporarily occludes the distal internal carotid artery (ICA). METHODS: Forty-eight high-risk patients (39 men, mean age 69.1 +/- 8 years, range 54 to 86) with 53 ICA stenoses underwent percutaneous angioplasty and stenting via the femoral approach under cerebral protection afforded by a 0.014-inch GuardWire balloon occlusion device. Mean stenosis was 82.1% +/- 9.65% (range 70 to 96) and mean lesion length was 16.0 +/- 7.5 mm (range 6 to 50). Thirty-three (62%) lesions were calcified, and 38 (72%) were ulcerated. Thirty-two (60%) of the lesions were asymptomatic. With the occlusion balloon inflated in the distal ICA, the lesion was dilated and stented. The area was cleaned by aspiration and flushed via an aspiration catheter advanced over the wire. Blood samples were collected from the external carotid artery (ECA) and analyzed to measure the size and number of particles collected. Computed tomography and neurological examinations were performed the day after the procedure. RESULTS: Immediate technical success was achieved in all patients with the implantation of 38 Palmaz stents, 8 Expander stents, and 11 Wallstents. Carotid occlusion was well tolerated in all patients but 1 who had multiple, severe carotid lesions and poor collateralization. Mean cerebral flow occlusion time was 346 +/- 153 seconds during predilation and 303 +/- 143 seconds during stent placement. Total mean flow occlusion time was 542 +/- 243 seconds. One immediate neurological complication (transient amaurosis) occurred in a patient who had an anastomosis between the external carotid (EC) and ICA territories. Debris was removed in all patients with a mean 0.8-mm diameter catheter. CONCLUSION: Cerebral protection with the GuardWire device is easy, safe, and effective in protecting the brain from cerebral embolism. Larger studies are warranted.


Assuntos
Angioplastia com Balão/instrumentação , Artéria Carótida Interna/cirurgia , Estenose das Carótidas/terapia , Embolia Intracraniana/prevenção & controle , Stents , Idoso , Idoso de 80 Anos ou mais , Artéria Carótida Interna/diagnóstico por imagem , Artéria Carótida Interna/ultraestrutura , Estenose das Carótidas/complicações , Estenose das Carótidas/diagnóstico por imagem , Angiografia Cerebral , Circulação Cerebrovascular , Estudos de Viabilidade , Feminino , Humanos , Embolia Intracraniana/diagnóstico por imagem , Embolia Intracraniana/etiologia , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler Transcraniana
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA