Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Eur J Heart Fail ; 24(5): 899-907, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35064722

RESUMO

AIMS: Transcatheter mitral valve implantation (TMVI) is a new treatment option for patients with symptomatic mitral valve (MV) disease. Real-world data have not yet been reported. This study aimed to assess procedural and 30-day outcomes of TMVI in a real-world patient cohort. METHOD AND RESULTS: All consecutive patients undergoing implantation of a transapically delivered self-expanding valve at 26 European centres from January 2020 to April 2021 were included in this retrospective observational registry. Among 108 surgical high-risk patients included (43% female, mean age 75 ± 7 years, mean STS-PROM 7.2 ± 5.3%), 25% was treated for an off-label indication (e.g. previous MV intervention or surgery, mitral stenosis, mitral annular calcification). Patients were highly symptomatic (New York Heart Association [NYHA] functional class III/IV in 86%) and mitral regurgitation (MR) was graded 3+/4+ in 95% (38% primary, 37% secondary, and 25% mixed aetiology). Technical success rate was 96%, and MR reduction to ≤1+ was achieved in all patients with successful implantation. There were two procedural deaths and 30-day all-cause mortality was 12%. At early clinical follow-up, MR reduction was sustained and there were significant reductions of pulmonary pressure (systolic pulmonary artery pressure 52 vs. 42 mmHg, p < 0.001), and tricuspid regurgitation severity (p = 0.013). Heart failure symptoms improved significantly (73% in NYHA class I/II, p < 0.001). Procedural success rate according to MVARC criteria was 80% and was not different in patients treated for an off-label indication (74% vs. 81% for off- vs. on-label, p = 0.41). CONCLUSION: In a real-world patient population, TMVI has a high technical and procedural success rate with efficient and durable MR reduction and symptomatic improvement.


Assuntos
Insuficiência Cardíaca , Doenças das Valvas Cardíacas , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/métodos , Feminino , Insuficiência Cardíaca/etiologia , Doenças das Valvas Cardíacas/etiologia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
2.
Curr Cardiol Rep ; 23(9): 131, 2021 08 13.
Artigo em Inglês | MEDLINE | ID: mdl-34387748

RESUMO

PURPOSE OF REVIEW: To provide a detailed overview of complications associated with MitraClip therapy and its development over time with the aim to alert physicians for early recognition of complications and to offer treatment strategies for each complication, if possible. RECENT FINDINGS: The MitraClip system (MC) is the leading transcatheter technique to treat mitral regurgitation (MR) and has been established as a safe procedure with very low adverse event rates compared to mitral surgery at intermediate to high risk or in secondary MR. Lately, the fourth MC generation has been launched with novel technical features to facilitate device handling, decrease complication rates, and allow the treatment of even complex lesions. Although the complication rate is low, adverse events are associated with increased morbidity and mortality. The most common complications are bleeding, acute kidney failure, procedure-induced mitral stenosis, and an iatrogenic atrial septal defect with unknown clinical impact.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/cirurgia , Fatores de Tempo , Resultado do Tratamento
3.
J Clin Med ; 10(14)2021 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-34300268

RESUMO

The aim of this study was to compare patients with transcatheter aortic valve replacement (TAVR) receiving new generation prostheses SAPIEN 3 (S3, Edwards Lifesc.) and Evolut R (ER, Medtronic Inc.) in terms of periprocedural and long-term outcome. Our retrospective, single-center analysis included 359 consecutive patients with severe aortic stenosis who underwent TAVR with S3 or ER from 2014-2016 (mean age 82 ± 7 years, 47% male, mean EuroSCORE II 8.0 ± 8%, mean follow-up 3.8 years). Device Success was equal (S3 93.0% vs. ER 92.4%, p = 0.812). We report a 30-day mortality of 2.8% in the S3 group, and 2.1% in the ER group (p = 0.674). There was no difference in stroke, conversion to open surgery, vascular and bleeding complications or myocardial infarction. While prosthesis mean gradients were higher with S3 (12.0 mmHg vs. 8.2 mmHg, p < 0.001), there was a trend to less paravalvular regurgitation (PVR moderate or severe: 1% vs. 3.6%, p = 0.088). All-cause mortality up to 5 years did not show a difference (mean survival S3 3.5 ± 0.24 years, ER 3.3 ± 0.29 years, p = 0.895). Independent predictors of long-term mortality were impaired LVEF, chronic kidney injury, peripheral artery disease, malignant tumor and periprocedural stroke. New generation TAVR valves offer an excellent implant and outcome success rate. Long-term survival was independent of prostheses choice and mainly attributed to comorbidities and complications.

4.
Can J Cardiol ; 37(7): 1094-1102, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33617978

RESUMO

BACKGROUND: Scarce data exist on patients with previous left valve surgery (PLVS) undergoing transcatheter tricuspid valve intervention (TTVI). This study sought to investigate the procedural and early outcomes in patients with PLVS undergoing TTVI. METHODS: This was a subanalysis of the multicenter TriValve registry including 462 patients, 82 (18%) with PLVS. Data were analyzed according to the presence of PLVS in the overall cohort and in a propensity score-matched population including 51 and 115 patients with and without PLVS, respectively. RESULTS: Patients with PLVS were younger (72 ± 10 vs 78 ± 9 years; p < 0.01) and more frequently female (67.1% vs 53.2%; P = 0.02). Similar rates of procedural success (PLVS 80.5%; no-PLVS 82.1%; P = 0.73), and 30-day mortality (PLVS 2.4%, no-PLVS 3.4%; P = 0.99) were observed. After matching, there were no significant differences in both all-cause rehospitalisation (PLVS 21.1%, no-PLVS 26.5%; P = 0.60) and all-cause mortality (PLVS 9.8%, no-PLVS 6.7%; P = 0.58). At last follow-up (median 6 [interquartile range 1-12] months after the procedure), most patients (81.8%) in the PLVS group were in NYHA functional class I-II (P = 0.12 vs no-PLVS group), and TR grade was ≤ 2 in 82.6% of patients (P = 0.096 vs no-PVLS group). A poorer right ventricular function and previous heart failure hospitalization determined increased risks of procedural failure and poorer outcomes at follow-up, respectively. CONCLUSIONS: In patients with PLVS, TTVI was associated with high rates of procedural success and low early mortality. However, about one-third of patients required rehospitalisation or died at midterm follow-up. These results would support TTVI as a reasonable alternative to redo surgery in patients with PLVS and suggest the importance of earlier treatment to improve clinical outcomes.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Valva Tricúspide/cirurgia , Disfunção Ventricular Direita , Idoso , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/estatística & dados numéricos , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Readmissão do Paciente/estatística & dados numéricos , Sistema de Registros/estatística & dados numéricos , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Análise de Sobrevida , Insuficiência da Valva Tricúspide/etiologia , Insuficiência da Valva Tricúspide/mortalidade , Insuficiência da Valva Tricúspide/cirurgia , Disfunção Ventricular Direita/diagnóstico , Disfunção Ventricular Direita/etiologia
5.
JACC Cardiovasc Interv ; 14(5): 501-511, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33582084

RESUMO

OBJECTIVES: The purpose of this observational first-in-human experience was to investigate the feasibility and safety of the EVOQUE tricuspid valve replacement system and its impact on short-term clinical outcomes. BACKGROUND: Transcatheter tricuspid intervention is a promising option for selected patients with severe tricuspid regurgitation (TR). Although transcatheter leaflet repair is an option for some, transcatheter tricuspid valve replacement (TTVR) may be applicable to a broader population. METHODS: Twenty-five patients with severe TR underwent EVOQUE TTVR in a compassionate-use experience. The primary outcome was technical success, with NYHA (NYHA) functional class, TR grade, and major adverse cardiac and cerebrovascular events assessed at 30-day follow-up. RESULTS: All patients (mean age 76 ± 3 years, 88% women) were at high surgical risk (mean Society of Thoracic Surgeons risk score 9.1 ± 2.3%), with 96% in NYHA functional class III or IV. TR etiology was predominantly functional, with mean tricuspid annular diameter of 44.8 ± 7.8 mm and mean tricuspid annular plane systolic excursion of 16 ± 2 mm. Technical success was 92%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 0%, 76% of patients were in NYHA functional class I or II, and TR grade was ≤2+ in 96%. Major bleeding occurred in 3 patients (12%), 2 patients (8%) required pacemaker implantation, and 1 patient (4%) required dialysis. CONCLUSIONS: This first-in-human experience evaluating EVOQUE TTVR demonstrated high technical success, acceptable safety, and significant clinical improvement. Larger prospective studies are needed to confirm durability and safety and the impact on long-term clinical outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Fatores de Tempo , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
6.
ESC Heart Fail ; 7(6): 3336-3344, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32915515

RESUMO

AIMS: Several approaches for transcatheter mitral valve repair for functional mitral valve regurgitation are established. Interventional direct annuloplasty is a novel trans-venous, trans-septal approach. While feasibility was proven recently, knowledge on its influence on cardiac dimensions, pressures, biomarkers, and clinical outcomes is sparse. METHODS AND RESULTS: Patients consecutively treated with direct annuloplasty-only procedures between December 2015 and April 2018 were included in this monocentric analysis. Echocardiographic measurements, biomarker levels, clinical status [New York Heart Association (NYHA) class and 6 min walk test] were assessed at baseline, at discharge, and at a 30 day follow-up. Overall, 18 patients (in mean 77.0 ± 7.4 years, 44.4% women) with initially all high-grade mitral valve regurgitation (MR) were included in this study. Procedural success rate was high (94.4%) without severe complications. Direct annuloplasty resulted in MR-reduction (post-procedural-MR mild or no/trace: 72.2%) and the proportion of patients with severe dyspnoea (NYHA III/IV) was reduced (88.9% vs. 50%, P = 0.008). Clinical results were associated with a relevant diminution of left atrial volumes (-16.5%, P < 0.001) and cardiac pressures [left atrial pressure (-32.3%, P = 0.019) and systolic pulmonary arterial pressure (PAP, -15.8%, P = 0.025)]. Patients with lower baseline levels of PAP (P = 0.022) as well as elevated highly sensitive troponin (P = 0.034) were more likely to archive clinical benefit (improvement in NYHA class ≥1 grade) after 1 month, which could not be correlated with the grade of MR-reduction. CONCLUSIONS: Transcatheter mitral valve repair by direct annuloplasty results in a relevant reduction of intracardiac pressures, left atrial volumes, dyspnoea, and MR. Lower PAP and higher troponin values at baseline could be associated to dyspnoea reduction.

7.
Echocardiography ; 37(9): 1436-1442, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32777134

RESUMO

OBJECTIVES: Several interventional approaches have been established for the treatment of severe mitral regurgitation (MR) in patients at elevated risk for surgery. Direct annuloplasty is a relatively novel option in transcatheter mitral valve repair dedicated to reverse pathology in specific subsets of MR. With regard to echocardiographic guidance, this procedure presents with higher efforts in comparison with edge-to-edge therapy to enable safe and exact positioning of the device's anchors; evidence on optimal peri-interventional imaging is sparse. We tested a specific 3D-echo-guidance protocol implementing single-beat multiplanar reconstruction (MPR) and evaluated its feasibility. METHODS: Overall, 16 patients consecutively treated with transcatheter direct annuloplasty for severe MR (87.5% functional/6.3% degenerative/6.3% mixed pathology) were entered in this monocentric analysis. Of these, two patients received a combined procedure including edge-to-edge repair. For all implantations, a 3D-echo-guidance protocol inheriting MPR was employed. RESULTS: Periprocedural device time decreased continuously (overall mean 140 ± 55.1 minutes, 213 ± 38 minutes in the first 4 vs 108 ± 33 minutes in the last 4 procedures, P = .018) using the MPR-based echo protocol, going along with reduced fluoroscopy times and doses. Technical success rate was high (93.8%) without any serious cardiac-related adverse events. MR could be relevantly improved. CONCLUSION: Echocardiographic guidance of transcatheter direct annuloplasty using a real time MPR-based protocol is feasible and safe. Optimized imaging might enable reduced implantation times and potentially increases safety.


Assuntos
Implante de Prótese de Valva Cardíaca , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Cateterismo Cardíaco , Estudos de Viabilidade , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Resultado do Tratamento
8.
ESC Heart Fail ; 7(4): 1400-1408, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32501644

RESUMO

AIMS: Mitral annuloplasty using the Carillon Mitral Contour System (CMCS) reduces secondary mitral regurgitation (SMR) and leads to reverse left ventricular remodelling. The aim of this study was to evaluate the effect of the CMCS on the mitral valve annulus (MA) and left atrial volume (LAV). METHODS AND RESULTS: We retrospectively evaluated the data of all patients treated with the CMCS at our centre. Using transthoracic echocardiography, MA diameters were assessed by measuring the anterolateral to posteromedial extend (ALPM) and the anterior to posterior (AP) dimensions, respectively. Also, LAV and left ventricular end-diastolic volume (LVEDV) were assessed. Patients were examined at three time points: baseline, at 20-60 days (30dFUP), and at 9-15 months (1yFUP), using paired analysis. From July 2014 until March 2019, 75 cases of severe SMR were treated using CMCS. Cases in which other devices were used in combination (COMBO therapy, n = 35) or in which the device could not be implanted (implant failure, n = 3) were excluded, leaving 37 patients in the present analysis. Analysis at 30dFUP showed a significant reduction of 16% in the mean ALPM diameter (7.27 ± 5.40 mm) and 15% in the AP diameter (6.57 ± 5.33 mm). Analysis of LAV also showed a significant reduction of 21% (36.61 ± 82.67 mL), with no significant change in LVEDV. At 1yFUP, the reduction of both the mean ALPM diameter of 14% (6.24 ± 5.70 mm) and the mean AP diameter of 12% (5.46 ± 4.99 mm) remained significant and stable. The reduction in LAV was also maintained at 23% (37.03 ± 56.91 mL). LAV index was significantly reduced by 17% at 30dFUP (15.44 ± 40.98 mL/m2 ) and by 13% at 1yFUP (11.56 ± 31.87 mL/m2 ), respectively. LVEDV index showed no significant change at 30dFUP and a non-significant 10% reduction at 1yFUP (17.75 ± 58.79 mL/m2 ). CONCLUSIONS: The CMCS successfully treats symptomatic SMR with a stable reduction of not only the AP diameter of the MA, but the current study also demonstrates an additional reduction of the ALPM dimension at both 30dFUP and 1yFUP. We have also shown for the first time that LAV and LAV index are significantly reduced at both 30dFUP and 1yFUP and a non-significant positive remodelling of the LVEDV. This positive left atrial remodelling has not been looked for and demonstrated in earlier randomized studies of CMCS.


Assuntos
Remodelamento Atrial , Anuloplastia da Valva Mitral , Insuficiência da Valva Mitral , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos
9.
J Am Soc Echocardiogr ; 32(10): 1359-1365, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31320267

RESUMO

Transcatheter direct annuloplasty has been introduced as a novel interventional treatment option for severe mitral valve regurgitation. Until now, only one direct annuloplasty device (Edwards Cardioband) has been commercially available, being implanted in more than 250 patients worldwide. Yet this procedure poses greater challenges regarding optimal fluoroscopic and echocardiographic guidance compared with edge-to-edge repair: correct localization and orientation of the anchors upon penetration into the fibrous mitral annulus tissue and the basal left ventricular myocardium are preconditions for an optimal result and essential to avoid damage of the neighboring structures (atrioventricular node, circumflex artery, coronary sinus). Real-time single-beat multiplanar reconstruction has become available as an additional imaging tool for three-dimensional transesophageal echocardiography in most recent echo machines. In this review, we introduce a three-dimensional transesophageal echocardiography-based imaging protocol implementing real-time multiplanar reconstruction for transcatheter direct annuloplasty procedures, which optimizes and also simplifies echocardiographic guidance during the implantation. The advanced echocardiographic protocol might also help to expedite implantation times and potentially increase the safety of the procedure. In this "how-to" article, we describe in detail this novel approach for optimized guidance and compare its advantages and challenges to "conventional" echocardiographic imaging for transcatheter mitral valve repair.


Assuntos
Cateterismo Cardíaco/métodos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Interpretação de Imagem Assistida por Computador , Anuloplastia da Valva Mitral/métodos , Insuficiência da Valva Mitral/cirurgia , Cirurgia Assistida por Computador , Humanos
10.
J Am Coll Cardiol ; 73(15): 1905-1915, 2019 04 23.
Artigo em Inglês | MEDLINE | ID: mdl-30999993

RESUMO

BACKGROUND: Severe tricuspid regurgitation (TR) is associated with high morbidity and mortality rates with limited treatment options. OBJECTIVES: The authors report the 6-month safety and performance of a transcatheter tricuspid valve reconstruction system in the treatment of moderate to severe functional TR in 30 patients enrolled in the TRI-REPAIR (TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System) study. METHODS: Between October 2016 and July 2017, 30 patients were enrolled in this single-arm, multicenter, prospective trial. Patients were diagnosed with moderate to severe, symptomatic TR in the absence of untreated left-heart disease and deemed inoperable because of unacceptable risk for open-heart surgery by the local heart team. Clinical, functional, and echocardiographic data were prospectively collected before and up to 6 months post-procedure. An independent core lab assessed all echocardiographic data, and an independent clinical event committee adjudicated the safety events. RESULTS: Mean patient age was 75 years, 73% were female, and 23% had ischemic heart disease. At baseline, 83% were in New York Heart Association (NYHA) functional class III to IV, and mean left ventricular ejection fraction was 58%. Technical success was 100%. Through 6 months, 3 patients died. Between 6 months and baseline, echocardiography showed average reductions of annular septolateral diameter of 9% (42 mm vs. 38 mm; p < 0.01), proximal isovelocity surface area effective regurgitant orifice area of 50% (0.8 cm2 vs. 0.4 cm2; p < 0.01), and mean vena contracta width of 28% (1.2 cm vs. 0.9 cm; p < 0.01). Clinical assessment showed that 76% of patients improved by at least 1 NYHA functional class with 88% in NYHA functional class I or II. Six-minute walk distance improved by 60 m (p < 0.01), and Kansas City Cardiomyopathy Questionnaire score improved by 24 points (p < 0.01). CONCLUSIONS: Six-month outcomes show that the system performs as intended and appears to be safe in patients with symptomatic and moderate to severe functional TR. Significant reduction of TR through decrease of annular dimensions, improvements in heart failure symptoms, quality of life, and exercise capacity were observed. Further studies are warranted to validate these initial promising results. (TrIcuspid Regurgitation RePAIr With CaRdioband Transcatheter System [TRI-REPAIR]; NCT02981953).


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Mortalidade Hospitalar/tendências , Insuficiência da Valva Tricúspide/cirurgia , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Ecocardiografia Doppler/métodos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Estudos Prospectivos , Procedimentos de Cirurgia Plástica/métodos , Procedimentos de Cirurgia Plástica/mortalidade , Medição de Risco , Índice de Gravidade de Doença , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/mortalidade
11.
Int J Cardiol ; 285: 21-26, 2019 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-30871803

RESUMO

BACKGROUND: Many candidates with ischaemic functional mitral regurgitation (FMR) have previously undergone coronary artery bypass grafting (CABG), in which transcatheter mitral valve repair can be reasonable for ameliorating the deteriorated hemodynamic and heart failure symptoms. We sought to elucidate the outcomes of MitraClip (MC) implantation in patients with symptomatic ischaemic FMR after CABG. METHODS: We investigated clinical characteristics, outcomes and predictive impact of previous CABG on mortality in ischaemic FMR patients who underwent MC implantation from two high-volume centres in Germany. RESULTS: We enrolled 159 patients who previously underwent CABG. Compared with a reference group that did not previously undergo CABG (n = 182), the cohort consisted of more elderly patients (75.0, standard deviation [SD] 7.7 versus 72.9, SD 9.6 years, p = 0.028), more men (84% vs. 69%, p < 0.001), and reduced tricuspid annular plane systolic excursion (14.0, SD 4.0, vs. 16.6, SD 4.6 mm, p < 0.0001). The CABG group showed similar outcomes regarding procedural success (91% vs. 94%, p = 0.24) and 30-day mortality (5.0% vs. 6.0%, p = 0.68), but worse survival after MC implantation (log-rank p = 0.019, hazard ratio 1.56 [95% confidence interval (CI) 1.08-2.26]). After propensity score matching (n = 224), the hazard ratio was 1.18 [95%CI 0.76-1.84] without statistical significance (p = 0.46). CONCLUSIONS: Transcatheter mitral valve repair using the MC is a viable treatment option for patients with symptomatic ischaemic FMR after CABG. Although the baseline characteristics seemed to point to sick patients, CABG itself had only a modest impact on survival.


Assuntos
Ponte de Artéria Coronária/métodos , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Isquemia Miocárdica/complicações , Idoso , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Masculino , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/mortalidade , Isquemia Miocárdica/mortalidade , Isquemia Miocárdica/cirurgia , Período Pós-Operatório , Prognóstico , Desenho de Prótese , Estudos Retrospectivos , Taxa de Sobrevida/tendências
12.
Eur Heart J ; 40(5): 466-472, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30124798

RESUMO

Aims: The Cardioband™ (Edwards Lifesciences) is a transcatheter implant designed to reduce mitral annulus size and mitral regurgitation (MR) severity. We report the 1-year outcomes of consecutive patients who underwent the Cardioband procedure between 2013 and 2016. Methods and results: Sixty patients with moderate or severe secondary MR (72 ± 7 years, 60% ischaemic origin) on guideline-recommended medical therapy were treated and analyzed at 11 European institutions. There were two in-hospital deaths (none device-related), one stroke, two coronary artery complications, and one tamponade. Anchor disengagement, observed in 10 patients (all but one in the first half of the population), resulted in device inefficacy in five patients and led to device modification half way through the study to mitigate this issue. Technical, device, and procedural successes, assessed based on Mitral Valve Academic Research Consortium (MVARC) criteria, were 97% (58/60), 72% (43/60), and 68% (41/60), respectively. At 1-year, overall survival, survival free of readmission for heart failure, and survival free of reintervention (performed in seven patients) were 87%, 66%, and 78%, respectively. In the overall population, MR grade at 12 months was moderate or less 61% and moderate or less in 95% of the 39 patients who underwent a transthoracic echocardiography at 1-year [but worsened by at least one grade in 11 patients (22%)]. Functional status (79% vs. 14% in New York Heart Association Class I/II), quality of life (-19 points on the Minnesota Living with Heart Failure Questionnaire score), and exercise capacity (+58 m by 6MWT) improved significantly (all P < 0.01). Conclusion: In this multicentre trial, the Cardioband mitral system demonstrated reasonable performance and safety. At 1 year, most patients had moderate or less MR and experienced significant functional improvements. A randomized controlled trial is underway to demonstrate the impact of Cardioband in patients on guideline-directed medical therapy.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Desenho de Prótese , Idoso , Feminino , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Masculino , Intervalo Livre de Progressão , Estudos Prospectivos , Recidiva , Reoperação/estatística & dados numéricos , Análise de Sobrevida , Resultado do Tratamento
13.
Semin Thorac Cardiovasc Surg ; 30(2): 152-157, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29545033

RESUMO

The objective of this study was to assess the results of catheter-based and surgical reinterventions in primary mitral regurgitation after failed MitraClip therapy. We report on 21 consecutive symptomatic patients with primary mitral regurgitation (median age 78 years) who underwent either repeat MitraClip therapy (n = 7) or mitral valve surgery (n = 14) after failure of the index procedure with 1-2 MitraClip implantations. At the time of reinterventions, 193 (interquartile range [IQR]: 32-622) days after the index procedure, patients had recurrent or persistent grade 3 mitral regurgitation. Early mortality at 30 days was 4.8%. Cardiac-related survival at 2 years was 85.4% (4 cardiac and 4 noncardiac deaths). Three of 7 patients with percutaneous reintervention were converted to surgery at 34, 52, and 56 days because repeat MitraClip therapy was ineffective because of pre-existing clip detachment or leaflet tear. Final therapy was biological mitral valve replacement in 14 of 21 patients (66.7%); 4 were treated with percutaneous repeat MitraClip repair (19%), and in 3 patients, surgical repairs were performed (14.3%). At follow-up with a median of 708 days, New York Heart Association class had improved significantly to class 2 (IQR: 1.0-2.5) (P = 0.0004), and the left ventricular end-diastolic diameter had decreased from 56 (IQR: 52-59) mm to 51 (48-58) mm (P = 0.0378), respectively. Recurrence of significant mitral regurgitation was absent in all but 1 patient with unsuccessful repeat MitraClip therapy who was deemed inoperable. Our data show that both repeat MitraClip and also mitral valve surgery are feasible and safe alternatives in patients without an excessively increased perioperative risk. We conclude that whenever leaflet insertion is not compromised, repeat catheter-based repair is a reasonable redo concept; in the remaining cases, surgery should be offered to the patient.


Assuntos
Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/métodos , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Tomada de Decisão Clínica , Intervalo Livre de Doença , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Estimativa de Kaplan-Meier , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/fisiopatologia , Seleção de Pacientes , Recuperação de Função Fisiológica , Recidiva , Reoperação , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
14.
Cardiol J ; 25(4): 459-469, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29512092

RESUMO

BACKGROUND: Suboptimal implantation of everolimus-eluting bioresorbable vascular scaffolds (EE-BVS) leading to strut malapposition and lack of neointima coverage has been hypothesized to be linked to late BVS-thrombosis. Optical coherence tomography (OCT) allows assessing subtle differences in BVS-healing. We aimed to link 6-months OCT-data on EE-BVS coverage and malapposition to implantation technique and clinical outcome. METHODS: Twenty-nine consecutive EE-BVS-patients were included. EE-BVS-implantation was guided by angiography in the first 17 patients (group 1). Vessel sizing prior to implantation and implantation result was assessed by OCT in the 12 following patients (group 2). EE-BVS-implantation was performed in both groups with adequate lesion preparation, sizing and systematic high-pressure post-dilatation. All patients received 6-months invasive control including OCT-analysis and clinical follow-up for 2 years. RESULTS: The rate of uncovered struts was group 1: 10.8 ± 10.0%; group 2: 10.6 ± 8.2%, p = 0.934. Target lesion failure due to BVS-thrombosis occurred in 2/17 patients at 9 and 18 months (11.8%, group 1), and no patients in group 2 (p = 0.218). CONCLUSIONS: Optical coherence tomography analysis at 6-months following EE-BVS-implantation finds almost 90% of struts to be covered. No difference between OCT vs. angiography-guided EE-BVS-implantation was observed. OCT at 6-months was not able to predict late BVS-thrombosis of EE-BVS.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Cirurgia Assistida por Computador/métodos , Alicerces Teciduais , Tomografia de Coerência Óptica/métodos , Implantes Absorvíveis , Doença da Artéria Coronariana/diagnóstico , Feminino , Seguimentos , Humanos , Imunossupressores/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento
15.
Eur Heart J Case Rep ; 2(2): yty035, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31020116

RESUMO

INTRODUCTION: Interventional left atrial appendage (LAA) occlusion is frequently performed in patients with atrial fibrillation with contraindications for or complications under oral anticoagulation or patients after electrical LAA isolation. CASE PRESENTATION: An endocardial LAA occlusion was attempted but resulted in perforation of the distal LAA and severe pericardial tamponade. To prevent open heart surgery, a cryoballoon was advanced to the base of the LAA and inflation resulted in complete occlusion and stopped further pericardial bleeding. An epicardial LAA suture device was then successfully implanted and completely sealed the LAA. No further pericardial bleeding occurred, and the patient fully recovered. DISCUSSION: A combination of a balloon device to occlude the base of the LAA and an epicardial suture device can be an emergency bail-out option in patients with a perforated LAA.

17.
Catheter Cardiovasc Interv ; 89(1): 154-158, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27762092

RESUMO

AIMS: Aims of this case-series were to assess the feasibility of cerebral protection devices in interventional left atrial appendage occlusion (iLAAO) procedures and to yield insight into the pathomorphological correlate of early, procedural cerebral embolization during iLAAO. METHODS AND RESULTS: Five consecutive patients underwent iLLO flanked by the Sentinel CPS® (Claret Medical, Inc., Santa Rosa, CA) cerebral protection system. Placement and recapture of the Sentinel® device as well as the iLAAO were successful and safe in all cases. Histomorphometric analysis of the collected filters showed embolized debris in all patients. Acute thrombus was found in three patients, organizing thrombus in four. Interestingly, two patients had endocardial or myocardial tissue in their filters. CONCLUSIONS: Cerebral protection during iLAAO with the Sentinel CPS® device is feasible. Furthermore, this dataset identifies the formation and embolization of thrombus and cardiac tissue as emboligeneic sources and potential future targets to reduce procedural complications. © 2016 Wiley Periodicals, Inc.


Assuntos
Apêndice Atrial , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Dispositivos de Proteção Embólica , Embolia Intracraniana/prevenção & controle , Acidente Vascular Cerebral/prevenção & controle , Trombose/prevenção & controle , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Biópsia , Cateterismo Cardíaco/efeitos adversos , Estudos de Viabilidade , Humanos , Embolia Intracraniana/diagnóstico , Embolia Intracraniana/etiologia , Pessoa de Meia-Idade , Miocárdio/patologia , Projetos Piloto , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Trombose/diagnóstico , Trombose/etiologia , Resultado do Tratamento
18.
J Am Heart Assoc ; 5(11)2016 11 10.
Artigo em Inglês | MEDLINE | ID: mdl-27930358

RESUMO

BACKGROUND: Histopathological analyses of debris captured by a cerebral protection system during transcatheter aortic valve replacement have been reported, but the origin of the captured debris was not determined and risk factors were not defined. METHODS AND RESULTS: Embolic debris was analyzed from 322 filters used in a dual-cerebral-filter protection system implemented during transcatheter aortic valve replacement for 161 patients (mean age 81 years, 82 male [51%], logistic EuroSCORE 19% [interquartile range 12-31%]). The debris capture rate was high, with debris from 97% of all patients (156 of 161). No differences by filter location were found (brachiocephalic trunk 86% [139 of 161], left carotid artery 91% [147 of 161]; adjusted P=0.999). Five prevalent types of debris were identified: thrombus (91%), arterial wall tissue (68%), valve tissue (53%), calcification (46%), and foreign material (30%). Female sex (P=0.0287, odds ratio 1.364, 95% CI 1.032-1.812) and diabetes mellitus (P=0.0116, odds ratio 1.474, 95% CI 1.089-2.001) were significant risk factors for embolic debris. Additional analysis showed significantly more valve tissue in patients with predilation (P=0.0294). Stroke and transient ischemic attack rates were 0.6% each (1 of 161). CONCLUSION: This study showed a high rate of embolic debris consisting of typical anatomic structures known to be altered in patients with aortic stenosis undergoing transcatheter aortic valve replacement. Female patients with diabetes mellitus have increased risk of embolic debris and should be protected by a cerebral protection system during transcatheter aortic valve replacement. Because valve tissue embolizes more often in patients with predilation, procedural planning should consider this finding. Both cerebral arteries (brachiocephalic trunk, left carotid artery) should be protected in the same way.


Assuntos
Estenose da Valva Aórtica/cirurgia , Dispositivos de Proteção Embólica , Complicações Pós-Operatórias/prevenção & controle , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica , Artérias , Tronco Braquiocefálico , Calcinose , Artérias Carótidas , Diabetes Mellitus/epidemiologia , Embolia , Feminino , Corpos Estranhos , Humanos , Ataque Isquêmico Transitório/epidemiologia , Masculino , Razão de Chances , Complicações Pós-Operatórias/epidemiologia , Fatores Sexuais , Acidente Vascular Cerebral/epidemiologia , Trombose
19.
EuroIntervention ; 12(7): 875-82, 2016 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-27639741

RESUMO

AIMS: The aim of this study was to assess the feasibility and early outcomes of transcatheter aortic valve implantation (TAVI) in dysfunctional TAVI prostheses (redo TAVI). METHODS AND RESULTS: Nineteen redo TAVI procedures were performed between October 2011 and November 2015 at two German centres. Mean age was 78 years, 13 (68%) were male, and the mean logistic EuroSCORE was 32%. Median time elapsed since index TAVI was 644 days (interquartile range 191-1,831). Failure mode of the index TAVI prosthesis was regurgitation (AR) in 16 patients (n=12 paravalvular AR, n=3 combined paravalvular/valvular AR, n=1 valvular AR) and stenosis in three patients. Device success was achieved in 89% (17/19). Median invasive post-interventional transprosthetic gradient was 3.0 mmHg. No severe prosthesis-patient mismatch (PPM) was observed. At one year, mean pressure gradient was 9±1.2 mmHg and no relevant PPM was documented in 90% of the cases. All-cause mortality at 30 days and one year was 11% and 33% (6/18, five non-cardiac deaths), respectively. Mean follow-up time was 404 days. CONCLUSIONS: Redo TAVI appears to be feasible. Paravalvular regurgitation was the most common indication for a redo procedure. Rates of device success were high with low post-interventional gradients and no severe PPM. Good functional status of the prosthesis was maintained after 12 months, but mortality rates were high in this small comorbid patient population.


Assuntos
Reoperação/estatística & dados numéricos , Substituição da Valva Aórtica Transcateter/estatística & dados numéricos , Idoso , Idoso de 80 Anos ou mais , Feminino , Alemanha , Humanos , Estimativa de Kaplan-Meier , Masculino , Estudos Retrospectivos
20.
Ann Thorac Surg ; 100(2): e27-9, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26234876

RESUMO

Intramyocardial dissecting hemorrhage is a very rare and potentially lethal complication of myocardial infarction. The diagnosis is typically made by echocardiography, by cardiac magnetic resonance imaging, at operation, or during postmortem examination. Medical treatment is most often associated with high mortality, and surgical treatment is required. We report a 53-year old man admitted to the urology department with a large left-sided kidney infarction. A subacute myocardial infarction by electrocardiogram, elevated troponin T level, and typical clinical signs of an acute coronary syndrome 5 days and 2 weeks before admission were also evident. Intramyocardial dissecting hemorrhage with an adjacent thrombotic formation was suspected by echocardiography and cardiac computed tomography and confirmed by magnetic resonance imaging. The patient underwent successful surgical correction and was discharged in good clinical condition.


Assuntos
Cardiopatias/etiologia , Cardiopatias/cirurgia , Hemorragia/etiologia , Hemorragia/cirurgia , Infarto do Miocárdio/complicações , Procedimentos Cirúrgicos Cardíacos/métodos , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA