Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
JBI Evid Synth ; 22(6): 1129-1134, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38165198

RESUMO

OBJECTIVE: The objective of this systematic review is to evaluate the best available evidence regarding effectiveness of transoral robotic surgery in patients with recurrent head and neck cancers. INTRODUCTION: Transoral robotic surgery is now an established modality of treatment for primary head and neck cancer, showing good swallowing outcomes and quality of life for patients post-treatment. In patients with recurrent disease, conventional open surgery is often used, which prolongs recovery time and necessitates tissue disruption to gain access to the tumor site. Transoral robotic surgery is an emerging technique in this field as a minimally invasive approach to resection. INCLUSION CRITERIA: The review will include experimental or observational studies that investigated the use of transoral robotic surgery in adults (aged 18 years or older) with recurrent head and neck cancers for oncological, functional, and survival outcomes. METHODS: Three databases will be searched for evidence: PubMed, Embase, and Scopus. Search terms for each database will include transoral robotic surgery, recurrent, salvage , and head and neck cancers . Reference lists of included articles will be searched for further evidence. Critical appraisal will be conducted by 2 independent reviewers using the JBI critical appraisal tools for quantitative studies. Data will be extracted by the same reviewers. Where appropriate, meta-analysis will be conducted for all outcomes. REVIEW REGISTRATION: PROSPERO CRD42023404613.


Assuntos
Neoplasias de Cabeça e Pescoço , Recidiva Local de Neoplasia , Procedimentos Cirúrgicos Robóticos , Revisões Sistemáticas como Assunto , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Neoplasias de Cabeça e Pescoço/cirurgia , Recidiva Local de Neoplasia/cirurgia , Qualidade de Vida
2.
ANZ J Surg ; 94(4): 536-544, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37872745

RESUMO

BACKGROUND: Sensorineural hearing loss (SNHL) may occur following cardiac surgery. Although preventing post-operative complications is vitally important in cardiac surgery, there are few guidelines regarding this issue. This review aimed to characterize SNHL after cardiac surgery. METHOD: This systematic review was registered on PROSPERO and conducted in accordance with PRISMA guidelines. A systematic search of the PubMed, Embase and Cochrane Library were conducted from inception. Eligibility determination, data extraction and methodological quality analysis were conducted in duplicate. RESULTS: There were 23 studies included in the review. In the adult population, there were six cohort studies, which included 36 cases of hearing loss in a total of 7135 patients (5.05 cases per 1000 operations). In seven cohort studies including paediatric patients, there were 88 cases of hearing loss in a total of 1342 operations. The majority of cases of hearing loss were mild in the adult population (56.6%). In the paediatric population 59.2% of hearing loss cases had moderate or worse hearing loss. The hearing loss most often affected the higher frequencies, over 6000 Hz. There have been studies indicating an association between hearing loss and extracorporeal circulation, but cases have also occurred without this intervention. CONCLUSION: SNHL is a rare but potentially serious complication after cardiac surgery. This hearing loss affects both paediatric and adult populations and may have significant long-term impacts. Further research is required, particularly with respect to the consideration of screening for SNHL in children after cardiac surgery.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Perda Auditiva Neurossensorial , Adulto , Humanos , Criança , Perda Auditiva Neurossensorial/epidemiologia , Perda Auditiva Neurossensorial/etiologia , Perda Auditiva Neurossensorial/diagnóstico , Estudos de Coortes , Complicações Pós-Operatórias/epidemiologia , Procedimentos Cirúrgicos Cardíacos/efeitos adversos
3.
JBI Evid Synth ; 21(10): 2099-2106, 2023 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-37246954

RESUMO

OBJECTIVE: The objective of this systematic review is to investigate oncological and functional outcomes following primary transoral surgery compared with non-surgical management in patients with small-volume (T1-2, N0-2) oropharyngeal cancer. INTRODUCTION: The incidence of oropharyngeal cancer is rising. Transoral surgery was introduced to provide a minimally invasive treatment option for patients with small-volume oropharyngeal cancer and to avoid the morbidity that results from open surgery and the potential acute and late toxicities of chemoradiotherapy. INCLUSION CRITERIA: The review will include all studies on adult patients with small-volume oropharyngeal cancer managed by transoral surgery or non-surgical management with radiotherapy and/or chemotherapy. All patients must have undergone treatment with curative intent. Participants who underwent palliative treatment will be excluded. METHODS: This review will follow the JBI methodology for systematic reviews of effectiveness. Eligible study designs will include randomized controlled trials, quasi-experimental studies, and prospective or retrospective cohort studies. Databases to be searched will include PubMed, Embase, CINAHL, Cochrane CENTRAL, and multiple trial registries from 1972. Titles and abstracts will be reviewed, and full-text articles will be retrieved if they meet the inclusion criteria. All eligible studies will be critically appraised by 2 independent reviewers using the appropriate JBI tools for experimental and observational designs. Where possible, outcome data from studies will be pooled with statistical meta-analysis to compare both oncological and functional outcomes between the two groups. All time to event to data will be converted to a common metric for oncological outcomes. The Grading of Recommendations, Assessment, Development and Evaluation (GRADE) approach will be followed to assess the certainty of findings. REVIEW REGISTRATION: PROSPERO CRD4202235209.


Assuntos
Neoplasias Orofaríngeas , Adulto , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Revisões Sistemáticas como Assunto , Neoplasias Orofaríngeas/cirurgia , Metanálise como Assunto , Literatura de Revisão como Assunto
4.
Surg Endosc ; 37(8): 6185-6196, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37165173

RESUMO

BACKGROUND: Gastrectomy with extended (D2) lymphadenectomy is considered standard of care for gastric cancer to provide the best possible outcomes and pathologic staging. However, D2 gastrectomy is a technically demanding operation and reported to be associated with increased complications and mortality. Application of sentinel lymph node (SLN) concept in gastric cancer has the potential to reduce patient morbidity; however, SLN techniques are not established for gastrectomy, in part due to lack of practical tracers. An effective and convenient tracer with enhanced SLN accumulation is critically needed. METHODS: Mannose-labelled magnetic tracer 'FerroTrace' and fluorescent dye indocyanine green (ICG) were injected laparoscopically into the stomach submucosa of 8 healthy swine under general anaesthesia. Intraoperative fluorescence imaging was used to highlight draining lymphatic pathways containing ICG, while preoperative T2-weighted MRI and ex vivo magnetometer probe measurements were used to identify nodes containing FerroTrace. Lymphadenectomy was performed either robotically (n = 2) or via laparotomy (n = 6). RESULTS: Mixing ICG and FerroTrace ensured concurrence of fluorescent and magnetic signals in SLNs. An initial trial with robotic dissection removed all magnetic LNs (n = 4). In the subsequent laparotomy study that targeted all ICG-LNs based on intraoperative fluorescence imaging, dissection removed an average of 4.7 ± 1.2 fluorescent, and 2.0 ± 1.3 magnetic LNs per animal. Both MRI and magnetometer detected 100% of SLNs (n = 7). FerroTrace demonstrated high specificity to SLNs, which contained 76 ± 30% of total lymphotropic iron, and 88 ± 20 % of the overall magnetometer signal. CONCLUSIONS: Through utilisation of this dual tracer approach, SLNs were identified via preoperative MRI, visualised intraoperatively with fluorescence imaging, and confirmed with a magnetometer. This combination pairs the sensitivity of ICG with SLN-specific FerroTrace and can be used for reliable SLN detection in gastric cancer, with potential applications in neoadjuvant therapy.


Assuntos
Nanopartículas de Magnetita , Linfonodo Sentinela , Neoplasias Gástricas , Animais , Suínos , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Linfonodo Sentinela/patologia , Verde de Indocianina , Biópsia de Linfonodo Sentinela/métodos , Manose , Neoplasias Gástricas/diagnóstico por imagem , Neoplasias Gástricas/cirurgia , Neoplasias Gástricas/patologia , Corantes , Excisão de Linfonodo , Corantes Fluorescentes , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia
5.
Head Neck ; 44(12): 2696-2707, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36082404

RESUMO

BACKGROUND: Sentinel lymph node biopsy (SLNB) is a staging procedure dependent on accurate mapping of draining lymphatics via tracers. Robot-assisted SLNB enables access to multiple neck levels with a single incision and intraoperative fluorescence guidance to the SLN. METHODS: Lymphatic mapping in swine was done using a magnetic tracer and fluorescent dye, injected into the tongue. MRI preoperatively mapped lymphatic spread of the magnetic tracer. Dissection was performed using a da Vinci Xi robot guided by fluorescence-imaging of the dye. RESULTS: Robot-assisted SLNB was successfully performed in all animals (n = 5). A novel MRI protocol differentiated SLNs (n = 6) from lower echelon nodes (n = 11) based on flow progression. Fluorescence imaging provided valuable intraoperative guidance and correlated with magnetic-positive nodes. CONCLUSIONS: This study demonstrates preclinical feasibility of a robot-assisted approach to SLNB using magnetic and fluorescent tracers in the head and neck, enabling both preoperative mapping and intraoperative guidance.


Assuntos
Robótica , Biópsia de Linfonodo Sentinela , Animais , Suínos , Biópsia de Linfonodo Sentinela/métodos , Fluorescência , Estudos de Viabilidade , Verde de Indocianina , Corantes Fluorescentes , Linfonodos/diagnóstico por imagem , Linfonodos/cirurgia , Linfonodos/patologia
6.
Nanomedicine ; 42: 102546, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35278683

RESUMO

Sentinel lymph node biopsy in cancers of the head and neck offers demonstrated clinical and diagnostic value, but adoption is limited by concerns about the detrimental consequence to survival of false negative results in a highly curable setting. The aim of this study was to demonstrate potential to overcome this via application of a novel mannose-labeled magnetic iron oxide tracer. In a large animal model, preoperative imaging and intraoperative magnetometer detection were used to identify magnetic lymph nodes. Iron quantification mapped the distribution of tracer within lymphatic levels. Over a 4-week test period, uptake of magnetic tracer in lymph nodes increased in a linear-like fashion, with a substantial percentage of accumulated iron (83%) being retained in the sentinel node. This result indicates a high affinity of mannose-labeled particles to the sentinel node, while providing a means for the magnetometer probe to indicate node status based on intraoperative signal.


Assuntos
Nanopartículas de Magnetita , Linfonodo Sentinela , Animais , Ferro , Linfonodos , Fenômenos Magnéticos , Manose , Linfonodo Sentinela/diagnóstico por imagem , Linfonodo Sentinela/cirurgia , Biópsia de Linfonodo Sentinela/métodos
7.
J Nucl Med ; 63(8): 1162-1168, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35027369

RESUMO

In head and neck cancer, a major limitation of current intraoperative margin analysis is the ability to detect areas most likely to be positive based on specimen palpation, especially for larger specimens where sampling error limits detection of positive margins. This study aims to prospectively examine the clinical value of fluorescent molecular imaging to accurately identify "the sentinel margin," the point on a specimen at which the tumor lies closest to the resected edge in real-time during frozen section analysis. Methods: Eighteen patients with oral squamous cell carcinoma were enrolled into a prospective clinical trial and infused intravenously with 50 mg of panitumumab-IRDye800CW 1-5 d before surgery. Resected specimens were imaged in a closed-field near-infrared optical imaging system in near real-time, and custom-designed software was used to identify locations of highest fluorescence on deep and peripheral margins. The surgeon identified the sentinel margin masked to optical specimen mapping, and then the regions of highest fluorescence were identified and marked for frozen analysis. Final pathology based on specimen reconstruction was used as reference standard. Results: Resected specimens were imaged in the operating room, and fluorescence had a higher interobserver agreement with pathology (Cohen κ value 0.96) than the surgeon (Cohen κ value of 0.82) for the location of the closest margin. Plotting margin distance at the predicted sentinel margin location of each observer versus the actual closest margin distance at pathology demonstrated best correlation between fluorescence and pathology (R2 = 0.98) with surgeon (R2 = 0.75). Conclusion: Fluorescence imaging can improve identification of the sentinel margin in head and neck cancer resections, holding promise for rapid identification of positive margins and improved oncologic outcomes.


Assuntos
Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Bucais , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/cirurgia , Corantes , Humanos , Margens de Excisão , Imagem Molecular , Neoplasias Bucais/diagnóstico por imagem , Neoplasias Bucais/cirurgia , Imagem Óptica/métodos , Estudos Prospectivos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia
8.
JBI Evid Synth ; 20(4): 1135-1141, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34698708

RESUMO

OBJECTIVE: The objective of this review is to investigate overall survival in patients with human papillomavirus positive oropharyngeal squamous cell carcinoma (HPV+ OPSCC) comparing standard- versus reduced-dose radiotherapy. INTRODUCTION: The improved survival of patients with HPV+ compared to HPV-negative OPSCC has raised the question of reducing the total radiation treatment dose delivered to patients with HPV+ OPSCC. A de-escalated radiotherapy protocol may provide equal oncological benefit, with reduced adverse events/toxicity. INCLUSION CRITERIA: We will include any adult patients aged 18years or older who have undergone curative intent treatment for HPV+ OPSCC. These patients can be at any stage at the time treatment is initiated. Exclusion criteria are as follows: pre-clinical or animal studies, patients with non-squamous cell carcinoma lesions of the oropharynx, patients with primary lesions in other head and neck sites, or patients receiving palliative treatment. METHODS: A three-step search strategy will be used to identify relevant articles for inclusion through MEDLINE, CINAHL, Embase, Web of Science, Scopus, and gray literature sources. These articles will be assessed against our inclusion and exclusion criteria at the title and abstract level as well as at full-text level. Remaining studies will be critically appraised based on their trial design. Data extraction will occur for all studies and, where possible, will be pooled with statistical meta-analysis. SYSTEMATIC REVIEW REGISTRATION NUMBER: PROSPERO CRD42021252161.


Assuntos
Alphapapillomavirus , Carcinoma de Células Escamosas , Neoplasias de Cabeça e Pescoço , Neoplasias Orofaríngeas , Infecções por Papillomavirus , Lesões por Radiação , Carcinoma de Células Escamosas/patologia , Carcinoma de Células Escamosas/radioterapia , Neoplasias de Cabeça e Pescoço/complicações , Humanos , Metanálise como Assunto , Neoplasias Orofaríngeas/patologia , Neoplasias Orofaríngeas/radioterapia , Papillomaviridae , Infecções por Papillomavirus/complicações , Infecções por Papillomavirus/terapia , Lesões por Radiação/complicações , Literatura de Revisão como Assunto , Carcinoma de Células Escamosas de Cabeça e Pescoço/complicações , Carcinoma de Células Escamosas de Cabeça e Pescoço/radioterapia , Revisões Sistemáticas como Assunto
9.
Theranostics ; 11(15): 7188-7198, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34158844

RESUMO

Rationale: Sentinel lymph node biopsy (SLNB) is a well-established minimally invasive staging procedure that maps the spread of tumour metastases from their primary site to the regional lymphatics. Currently, the procedure requires the local peri-tumoural injection of radiolabelled and/or optical agents, and is therefore operator dependent, disruptive to surgical workflow and restricted largely to a small subset of malignancies that can be readily accessed externally for local tracer injection. The present study set out to determine whether intravenous (IV) infusion of a tumor-targeted tracer could identify sentinel and metastatic lymph nodes (LNs) in order to overcome these limitations. Methods: We examined 27 patients with oral squamous cell carcinoma (OSCC), 18 of whom were clinically node negative (cN0). Patients were infused intravenously with 50mg of Panitumumab-IRDye800CW prior to surgical resection of their primary tumour with neck dissection and/or SLNB. Lymphadenectomy specimens underwent fluorescence molecular imaging to evaluate tracer distribution to LNs. Results: A total of 960 LNs were analysed, of which 34 (3.5%) contained metastatic disease. Panitumumab-IRDye800CW preferentially localized to metastatic and sentinel LNs as evidenced by a higher fluorescent signal relative to other lymph nodes. The median MFI of metastatic LNs was significantly higher than the median MFI of benign LNs (0.06 versus 0.02, p < 0.05). Furthermore, selecting the highest five fluorescence intensity LNs from individual specimens resulted in 100% sensitivity, 85.8% specificity and 100% negative predictive value (NPV) for the detection of occult metastases and 100% accuracy for clinically staging the neck. In the cN+ cohort, assessment of the highest 5 fluorescence LNs per patient had 87.5% sensitivity, 93.2% specificity and 99.1% NPV for the detection of metastatic nodes. Conclusion: When intravenously infused, a tumour-targeted tracer localized to sentinel and metastatic lymph nodes. Further validation of an IV tumor-targeted tracer delivery approach for SLNB could dramatically change the practice of SLNB, allowing its application to other malignancies where the primary tumour is not accessible for local tracer injection.


Assuntos
Benzenossulfonatos/administração & dosagem , Neoplasias de Cabeça e Pescoço/patologia , Indóis/administração & dosagem , Metástase Linfática/patologia , Panitumumabe/administração & dosagem , Biópsia de Linfonodo Sentinela , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Administração Intravenosa , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
10.
Laryngoscope ; 131(3): 529-534, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33593036

RESUMO

The rate of positive margins in head and neck cancers has remained stagnant over the past three decades and is consistently associated with poor overall survival. This suggests that significant improvements must be made intraoperatively to ensure negative margins. We discuss the important role of fluorescence imaging to guide surgical oncology in head and neck cancer. This review includes a general overview of the principles of fluorescence, available fluorophores used for fluorescence imaging, and specific clinical applications of fluorescence-guided surgery, as well as challenges and future directions in head and neck surgical oncology. Laryngoscope, 131:529-534, 2021.


Assuntos
Neoplasias de Cabeça e Pescoço/cirurgia , Imagem Óptica/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço/cirurgia , Cirurgia Assistida por Computador/métodos , Fluorescência , Humanos , Margens de Excisão
11.
Mol Imaging Biol ; 23(1): 109-116, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32880818

RESUMO

PURPOSE: The development of molecularly targeted tracers is likely to improve the accuracy of diagnostic, screening, and therapeutic tools. Despite the many therapeutic antibodies that are FDA-approved with known toxicity, only a limited number of antibody-dye conjugates have been introduced to the clinic. Thorough evaluation of the safety, stability, and pharmacokinetics of antibody conjugates in the clinical setting compared with their parental components could accelerate the clinical approval of antibodies as agents for molecular imaging. Here we investigate the safety and stability of a near-infrared fluorescent dye (IRDye800CW) conjugated panitumumab, an approved therapeutic antibody, and report on the product stability, pharmacokinetics, adverse events, and QTc interval changes in patients. PROCEDURES: Panitumumab-IRDye800CW was made under good manufacturing practice (GMP) conditions in a single batch on March 26, 2014, and then evaluated over 4.5 years at 0, 3, and 6 months, and then at 6-month intervals thereafter. We conducted early phase trials in head and neck, lung, pancreas, and brain cancers with panitumumab-IRDye800CW. Eighty-one patients scheduled to undergo standard-of-care surgery were infused with doses between 0.06 to 2.83 mg/kg of antibody. Patient ECGs, blood samples, and adverse events were collected over 30-day post-infusion for analysis. RESULTS: Eighty-one patients underwent infusion of the study drug at a range of doses. Six patients (7.4 %) experienced an adverse event that was considered potentially related to the drug. The most common event was a prolonged QTc interval which occurred in three patients (3.7 %). Panitumumab-IRDye800CW had two OOS results at 42 and 54 months while meeting all other stability testing criteria. CONCLUSIONS: Panitumumab-IRDye800CW was safe and stable to administer over a 54-month window with a low rate of adverse events (7.4 %) which is consistent with the rate associated with panitumumab alone. This data supports re-purposing therapeutic antibodies as diagnostic imaging agents with limited preclinical toxicology studies.


Assuntos
Benzenossulfonatos/efeitos adversos , Benzenossulfonatos/química , Indóis/efeitos adversos , Indóis/química , Imagem Molecular , Imagem Óptica , Panitumumabe/efeitos adversos , Panitumumabe/química , Adulto , Idoso , Idoso de 80 Anos ou mais , Benzenossulfonatos/farmacocinética , Feminino , Humanos , Indóis/farmacocinética , Masculino , Pessoa de Meia-Idade , Panitumumabe/farmacocinética
12.
Mol Imaging Biol ; 23(2): 270-276, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33078373

RESUMO

PURPOSE: This study evaluated the effect of formalin fixation for near-infrared (NIR) fluorescence imaging of an antibody-dye complex (panitumumab-IRDye800CW) that was intravenously administered to patients with head and neck squamous cell carcinoma (HNSCC) scheduled to undergo surgery of curative intent. PROCEDURES: HNSCC patients were infused with 25 or 50 mg of panitumumab-IRDye800CW followed by surgery 1-5 days later. Following resection, primary tumor specimens were imaged in a closed-field fluorescence imaging device, before and after formalin fixation. The fluorescence images of formalin-fixed specimens were compared with images prior to formalin fixation. Regions of interest were drawn on the primary tumor and on the adjacent normal tissue on the fluorescence images. The mean fluorescence intensity (MFI) and tumor-to-background ratios (TBRs) of the fresh and formalin-fixed tissues were compared. RESULTS: Of the 30 enrolled patients, 20 tissue specimens were eligible for this study. Formalin fixation led to an average of 10 % shrinkage in tumor specimen size (p < 0.0001). Tumor MFI in formalin-fixed specimens was on average 10.9 % lower than that in the fresh specimens (p = 0.0002). However, no statistical difference was found between the TBRs of the fresh specimens and those of the formalin-fixed specimens (p = 0.85). CONCLUSIONS: Despite the 11 % decrease in MFI between fresh and formalin-fixed tissue specimens, the relative difference between tumor and normal tissue as measured in TBR remained unchanged. This data suggests that evaluation of formalin-fixed tissue for assessing the accuracy of fluorescence-guided surgery approaches could provide a valid, yet more flexible, alternative to fresh tissue analysis. TRIAL REGISTRATION: NCT02415881.


Assuntos
Benzenossulfonatos/administração & dosagem , Formaldeído/química , Neoplasias de Cabeça e Pescoço/diagnóstico por imagem , Indóis/administração & dosagem , Panitumumabe/administração & dosagem , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Carcinoma de Células Escamosas de Cabeça e Pescoço/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Antineoplásicos Imunológicos/administração & dosagem , Receptores ErbB/metabolismo , Feminino , Fluorescência , Neoplasias de Cabeça e Pescoço/tratamento farmacológico , Neoplasias de Cabeça e Pescoço/metabolismo , Neoplasias de Cabeça e Pescoço/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Molecular/métodos , Espectroscopia de Luz Próxima ao Infravermelho/instrumentação , Carcinoma de Células Escamosas de Cabeça e Pescoço/tratamento farmacológico , Carcinoma de Células Escamosas de Cabeça e Pescoço/metabolismo , Carcinoma de Células Escamosas de Cabeça e Pescoço/patologia , Fixação de Tecidos/métodos
13.
Neural Comput ; 32(12): 2389-2421, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32946714

RESUMO

Measuring functional connectivity from fMRI recordings is important in understanding processing in cortical networks. However, because the brain's connection pattern is complex, currently used methods are prone to producing false functional connections. We introduce differential covariance analysis, a new method that uses derivatives of the signal for estimating functional connectivity. We generated neural activities from dynamical causal modeling and a neural network of Hodgkin-Huxley neurons and then converted them to hemodynamic signals using the forward balloon model. The simulated fMRI signals, together with the ground-truth connectivity pattern, were used to benchmark our method with other commonly used methods. Differential covariance achieved better results in complex network simulations. This new method opens an alternative way to estimate functional connectivity.


Assuntos
Encéfalo/fisiologia , Processamento de Imagem Assistida por Computador/métodos , Rede Nervosa/fisiologia , Redes Neurais de Computação , Vias Neurais/fisiologia , Animais , Mapeamento Encefálico/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Modelos Neurológicos
14.
Laryngoscope ; 130(12): 2811-2817, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-31854462

RESUMO

OBJECTIVE: Endoscopic resection of sinonasal squamous cell carcinoma has become the standard of care, but challenges remain in obtaining clear resection margins. The current study evaluated the feasibility of endoscopic fluorescence-guided surgery (FGS) to improve surgical resection in a human sinus surgical model. METHODS: A fluorescence endoscope optimized for near-infrared (NIR) fluorescence detection was evaluated in a phantom study. Various endoscope diameters (4 and 10 mm) and viewing angles (0, 30, and 45 degrees) were evaluated to determine the sensitivity of the system for IRDye800CW detection at various working distances (1-5 cm). Endoscopic FGS was then validated in a three-dimensional human sinus surgical model to which squamous cell tumors derived from mice were inserted. Mice had received intravenous panitumumab-IRDye800CW and upon fluorescence-guided tumor resection, mean fluorescence intensity (MFI) and tumor-to-background ratio (TBR) were calculated in in situ and ex vivo settings. RESULTS: A significantly higher fluorescence intensity was found when using the 10-mm diameter endoscope compared to the 4mm diameter endoscope (P < .001). No significant difference in MFI was found among the viewing angles of the 4-mm diameter endoscope. Using the human sinus model, the highest MFI and TBR were obtained at a 1-cm working distance compared to longer working distances. CONCLUSION: We demonstrate that clinically acceptable TBRs were obtained with several working distances to discriminate tumor tissue from adjacent normal tissue in a human sinus model, and that endoscopic FGS may have great potential in identifying residual tumor tissue regions during surgery. Laryngoscope, 2019.


Assuntos
Endoscopia/métodos , Imagem Óptica/métodos , Neoplasias dos Seios Paranasais/cirurgia , Cirurgia Assistida por Computador/métodos , Animais , Fluorescência , Corantes Fluorescentes , Humanos , Camundongos , Panitumumabe , Imagens de Fantasmas , Sensibilidade e Especificidade
15.
Nutrients ; 11(7)2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31336626

RESUMO

Nutritional phenotyping can help achieve personalized nutrition, and machine learning tools may offer novel means to achieve phenotyping. The primary aim of this study was to use energy balance components, namely input (dietary energy intake and macronutrient composition) and output (physical activity) to predict energy stores (body weight) as a way to evaluate their ability to identify potential phenotypes based on these parameters. From the Women's Health Initiative Observational Study (WHI OS), carbohydrates, proteins, fats, fibers, sugars, and physical activity variables, namely energy expended from mild, moderate, and vigorous intensity activity, were used to predict current body weight (both as body weight in kilograms and as a body mass index (BMI) category). Several machine learning tools were used for this prediction. Finally, cluster analysis was used to identify putative phenotypes. For the numerical predictions, the support vector machine (SVM), neural network, and k-nearest neighbor (kNN) algorithms performed modestly, with mean approximate errors (MAEs) of 6.70 kg, 6.98 kg, and 6.90 kg, respectively. For categorical prediction, SVM performed the best (54.5% accuracy), followed closely by the bagged tree ensemble and kNN algorithms. K-means cluster analysis improved prediction using numerical data, identified 10 clusters suggestive of phenotypes, with a minimum MAE of ~1.1 kg. A classifier was used to phenotype subjects into the identified clusters, with MAEs <5 kg for 15% of the test set (n = ~2000). This study highlights the challenges, limitations, and successes in using machine learning tools on self-reported data to identify determinants of energy balance.


Assuntos
Peso Corporal , Exercício Físico , Aprendizado de Máquina , Nutrientes , Análise por Conglomerados , Feminino , Humanos , Modelos Biológicos , Redes Neurais de Computação , Estado Nutricional , Pós-Menopausa
16.
Front Oncol ; 9: 1476, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31998640

RESUMO

Objective: Complete surgical resection is the standard of care for treatment of oral cancer although the positive margin rate remains 15-30%. Tissue sampling from the resected specimen and from the wound bed for frozen section analysis (FSA) remains the mainstay for intraoperative margin assessment but is subject to sampling error and can require the processing of multiple samples. We sought to understand if an ex vivo imaging strategy using a tumor-targeted fluorescently labeled antibody could accurately identify the closest peripheral margin on the mucosal surface of resected tumor specimen, so that this "sentinel margin" could be used to guide pathological sampling. Materials and Methods: Twenty-nine patients with oral squamous cell carcinoma scheduled for surgical resection were consented for the study and received systemic administration of a tumor-targeted fluorescently labeled antibody (Panitumumab IRDye800CW). After surgical resection, the tumor specimen was imaged using a closed-field fluorescent imaging device. Relevant pathological data was available for five patients on retrospective review. For each of these five patients, two regions of highest fluorescence intensity at the peripheral margin and one region of lowest fluorescence intensity were identified, and results were correlated with histology to determine if the region of highest fluorescence intensity along the mucosal margin (i.e., the sentinel margin) was truly the closest margin. Results: Imaging acquisition of the mucosal surface of the specimen immediately after surgery took 30 s. In all of the specimens, the region of highest fluorescence at the specimen edge had a significantly smaller margin distance than other sampled regions. The average margin distance at the closest, "sentinel," margin was 3.2 mm compared to a margin distance of 8.0 mm at other regions (p < 0.0001). Conclusions: This proof-of-concept study suggests that, when combined with routine FSA, ex vivo fluorescent specimen imaging can be used to identify the closest surgical margin on the specimen. This approach may reduce sampling error of intraoperative evaluation, which should ultimately improve the ability of the surgeon to identify the sentinel margin. This rapid sentinel margin identification improves the surgeon's orientation to areas most likely to be positive in the surgical wound bed and may expedite pathology workflow.

17.
J Robot Surg ; 13(2): 301-307, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30128930

RESUMO

Transoral robotic surgery (TORS) provides improved access to head and neck subsites resulting in well-validated functional and oncological outcomes, but access to and cost of robotic platforms can limit their use. Evidence suggests TORS is increasingly being adopted globally, but there is a paucity of data on the adoption and diffusion of TORS in Australia and New Zealand. A cross-sectional analysis was performed. An online survey was distributed to otolaryngologists and head and neck surgeons through three different Australian and New Zealand specialty membership databases. A 5-point Likert scale based on a Unified Theory of Acceptance and Use of Technology (UTAUT) model was incorporated to assess barriers and facilitators to adoption. 77 respondents completed the survey. 43.6% of head and neck surgeons had performed TORS. The most common cases were lateral oropharyngectomy (35.9%), base of tongue resection (33.3%), tongue base mucosectomy (28.2%), supraglottic laryngectomy (15.4%) and TORS for obstructive sleep apnoea (12.8%). Perceived barriers to adoption were high costs, access to and availability of the robotic platform and limited training opportunities. This study provides evidence of adoption of TORS in Australia and New Zealand; however, there is a perception that significant barriers to adoption persist. Results from this study may help guide decisions on how we train and license surgeons in the era of this technology.


Assuntos
Neoplasias de Cabeça e Pescoço/cirurgia , Otorrinolaringologistas , Utilização de Procedimentos e Técnicas/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Cirurgiões , Inquéritos e Questionários , Adulto , Austrália/epidemiologia , Estudos Transversais , Feminino , Humanos , Laringectomia/métodos , Laringectomia/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Procedimentos Cirúrgicos Minimamente Invasivos/estatística & dados numéricos , Nova Zelândia/epidemiologia , Faringectomia/métodos , Faringectomia/estatística & dados numéricos , Utilização de Procedimentos e Técnicas/tendências , Procedimentos Cirúrgicos Robóticos/educação , Língua/cirurgia
19.
Proc Natl Acad Sci U S A ; 115(26): 6858-6863, 2018 06 26.
Artigo em Inglês | MEDLINE | ID: mdl-29884650

RESUMO

Resting- or baseline-state low-frequency (0.01-0.2 Hz) brain activity is observed in fMRI, EEG, and local field potential recordings. These fluctuations were found to be correlated across brain regions and are thought to reflect neuronal activity fluctuations between functionally connected areas of the brain. However, the origin of these infra-slow resting-state fluctuations remains unknown. Here, using a detailed computational model of the brain network, we show that spontaneous infra-slow (<0.05 Hz) activity could originate due to the ion concentration dynamics. The computational model implemented dynamics for intra- and extracellular K+ and Na+ and intracellular Cl- ions, Na+/K+ exchange pump, and KCC2 cotransporter. In the network model simulating resting awake-like brain state, we observed infra-slow fluctuations in the extracellular K+ concentration, Na+/K+ pump activation, firing rate of neurons, and local field potentials. Holding K+ concentration constant prevented generation of the infra-slow fluctuations. The amplitude and peak frequency of this activity were modulated by the Na+/K+ pump, AMPA/GABA synaptic currents, and glial properties. Further, in a large-scale network with long-range connections based on CoCoMac connectivity data, the infra-slow fluctuations became synchronized among remote clusters similar to the resting-state activity observed in vivo. Overall, our study proposes that ion concentration dynamics mediated by neuronal and glial activity may contribute to the generation of very slow spontaneous fluctuations of brain activity that are reported as the resting-state fluctuations in fMRI and EEG recordings.


Assuntos
Encéfalo/fisiologia , Simulação por Computador , Modelos Neurológicos , Rede Nervosa/fisiologia , Transmissão Sináptica/fisiologia , Humanos , ATPase Trocadora de Sódio-Potássio/metabolismo , Simportadores/metabolismo , Ácido alfa-Amino-3-hidroxi-5-metil-4-isoxazol Propiônico/metabolismo , Ácido gama-Aminobutírico/metabolismo
20.
J Comput Neurosci ; 44(1): 1-24, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29230640

RESUMO

During slow-wave sleep, brain electrical activity is dominated by the slow (< 1 Hz) electroencephalogram (EEG) oscillations characterized by the periodic transitions between active (or Up) and silent (or Down) states in the membrane voltage of the cortical and thalamic neurons. Sleep slow oscillation is believed to play critical role in consolidation of recent memories. Past computational studies, based on the Hodgkin-Huxley type neuronal models, revealed possible intracellular and network mechanisms of the neuronal activity during sleep, however, they failed to explore the large-scale cortical network dynamics depending on collective behavior in the large populations of neurons. In this new study, we developed a novel class of reduced discrete time spiking neuron models for large-scale network simulations of wake and sleep dynamics. In addition to the spiking mechanism, the new model implemented nonlinearities capturing effects of the leak current, the Ca2+ dependent K+ current and the persistent Na+ current that were found to be critical for transitions between Up and Down states of the slow oscillation. We applied the new model to study large-scale two-dimensional cortical network activity during slow-wave sleep. Our study explained traveling wave dynamics and characteristic synchronization properties of transitions between Up and Down states of the slow oscillation as observed in vivo in recordings from cats. We further predict a critical role of synaptic noise and slow adaptive currents for spike sequence replay as found during sleep related memory consolidation.


Assuntos
Encéfalo/fisiologia , Simulação por Computador , Modelos Neurológicos , Neurônios/fisiologia , Dinâmica não Linear , Potenciais de Ação/fisiologia , Ondas Encefálicas/fisiologia , Eletroencefalografia , Humanos , Vias Neurais/fisiologia , Canais de Sódio/fisiologia , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA