Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
J Radiol Prot ; 44(2)2024 Jun 13.
Artigo em Inglês | MEDLINE | ID: mdl-38838649

RESUMO

Protection against ionizing radiations is important in laboratories with radioactive materials and high energy cyclotron beams. The Cyclotron and Radioisotope Center (CYRIC) located in Tohoku University in Miyagi prefecture, Japan and is a well-known nuclear science laboratory with cyclotron beams and substantial number of high activity radioactive materials. Considering this, it is important to perform complete radiation transport computations to ensure the safety of non-occupational and occupational workers. In the present work, we have developed a complete 3-dimensional model of the main cyclotron building and radiation labs using Monte Carlo method. We have found that the dispersed photons and neutrons inside and in the surrounding of the CYRIC building pose no significant risk to occupational and non-occupational workers. The present work and the developed models would be useful in the field of radiation protection.


Assuntos
Ciclotrons , Método de Monte Carlo , Proteção Radiológica , Japão , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/análise , Doses de Radiação , Simulação por Computador , Humanos , Universidades
2.
Radiat Prot Dosimetry ; 200(8): 802-807, 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38773775

RESUMO

Interventional cardiology is characterized by high radiation exposure for both the patient and the operator. Adequate shielding and monitoring of the operator are fundamental to comply with radiation protection principles. In a previous work, the effect on the dose of the dosemeter position on the chest was studied. In this paper, the investigation has been completed, employing an anthropomorphic thorax phantom, equipped with arms. Although there are differences between the Monte Carlo simulations and the measurements, similar trends are observed, showing that the reduction in dose, due to the arms, is between 20 and 60%, compared with the situation without arms. For that reason, considering a dosemeter placed on the chest, the upper position, which is the least affected by the arms, should be preferred while the extreme lateral position, near the armpit, should be avoided.


Assuntos
Simulação por Computador , Método de Monte Carlo , Exposição Ocupacional , Imagens de Fantasmas , Roupa de Proteção , Doses de Radiação , Monitoramento de Radiação , Proteção Radiológica , Humanos , Exposição Ocupacional/análise , Exposição Ocupacional/prevenção & controle , Proteção Radiológica/métodos , Monitoramento de Radiação/métodos , Cardiologia/métodos , Corpo Clínico , Tórax/efeitos da radiação
3.
Health Phys ; 124(4): 301-309, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-36728190

RESUMO

ABSTRACT: The present work introduces an open-source graphical user interface (GUI) computer program called DynamicMC. The present program has the ability to generate ORNL phantom input script for the Monte Carlo N-Particle (MCNP) package. The relative dynamic movement of the radiation source with respect to the ORNL phantom can be modeled, which essentially resembles the dynamic movement of source-to-target (i.e., human phantom) distance in a 3-dimensional radiation field. The present program makes the organ-based dosimetry of the human body much easier, as users are not required to write lengthy scripts or deal with any programming that many may find tedious, time consuming, and error prone. In this paper, we have demonstrated that the present program can successfully model simple and complex relative dynamic movements (i.e., those involving rotation of source and human phantom in a 3-dimensional field). The present program would be useful for organ-based dosimetry and could also be used as a tool for teaching nuclear radiation physics and its interaction with the human body.


Assuntos
Radiometria , Software , Humanos , Radiometria/métodos , Imagens de Fantasmas , Método de Monte Carlo , Simulação por Computador
4.
Appl Radiat Isot ; 192: 110614, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36527853

RESUMO

Absorbed doses in uterus during brachytherapy were calculated with MCNP in relevant points and compared with planning system for one patients. MCNP was applied with two different humanoid phantoms in input, ORNL and voxel models, which represent human body in mathematical way. Good agreement between both phantoms, as well as, between MCNP and planning system were found. In addition the doses in critical organs (bladder and colon in this kind of therapy), were calculated and compared with maximal doses in these organs obtained from planning system for 15 other patients. MCNP doses agree well with planning system in points of uterus for those 15 patients, where radioactive source is used to apply. However, there are systematical discrepancies between doses in colon and bladder obtained by MCNP and planning system.


Assuntos
Braquiterapia , Neoplasias do Colo do Útero , Feminino , Humanos , Braquiterapia/métodos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Dosagem Radioterapêutica , Método de Monte Carlo , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos
5.
Sci Rep ; 12(1): 18098, 2022 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-36302927

RESUMO

The present work introduced a framework to investigate the effectiveness of proton boron fusion therapy (PBFT) at the cellular level. The framework consisted of a cell array generator program coupled with PHITS Monte Carlo package with a dedicated terminal-based code editor that was developed in this work. The framework enabled users to model large cell arrays with normal, all boron, and random boron filled cytoplasm, to investigate the underlying mechanism of PBFT. It was found that alpha particles and neutrons could be produced in absence of boron mainly because of nuclear reaction induced by proton interaction with 16O, 12C and 14N nuclei. The effectiveness of PBFT is highly dependent on the incident proton energy, source size, cell array size, buffer medium thickness layer, concentration and distribution of boron in the cell array. To quantitatively assess the effectiveness of PBFT, of the total energy deposition by alpha particle for different cases were determined. The number of alpha particle hits in cell cytoplasm and nucleus for normal and 100 ppm boron were determined. The obtained results and the developed tools would be useful for future development of PBFT to objectively determine the effectiveness of this treatment modality.


Assuntos
Terapia por Captura de Nêutron de Boro , Terapia com Prótons , Boro , Terapia por Captura de Nêutron de Boro/métodos , Prótons , Nêutrons , Método de Monte Carlo
6.
PLoS One ; 16(9): e0257638, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34534258

RESUMO

Some concepts in nuclear radiation physics are abstract and intellectually demanding. In the present paper, an "MCHP platform" (MCHP was an acronym for Monte Carlo simulations + Human Phantoms) was proposed to provide assistance to the students through visualization. The platform involved Monte Carlo simulations of interactions between ionizing radiations and the Oak Ridge National Laboratory (ORNL) adult male human phantom. As an example to demonstrate the benefits of the proposed MCHP platform, the present paper investigated the variation of the absorbed photon dose per photon from a 137Cs source in three selected organs, namely, brain, spine and thyroid of an adult male for concrete and lead shields with varying thicknesses. The results were interesting but not readily comprehensible without direct visualization. Graphical visualization snapshots as well as video clips of real time interactions between the photons and the human phantom were presented for the involved cases, and the results were explained with the help of such snapshots and video clips. It is envisaged that, if the platform is found useful and effective by the readers, the readers can also propose examples to be gradually added onto this platform in future, with the ultimate goal of enhancing students' understanding and learning the concepts in an undergraduate nuclear radiation physics course or a related course.


Assuntos
Método de Monte Carlo , Física Nuclear/educação , Proteção Radiológica/métodos , Encéfalo/efeitos da radiação , Radioisótopos de Césio/química , Corpo Humano , Humanos , Fótons , Proteção Radiológica/instrumentação , Radiação Ionizante , Radiometria , Estudantes
7.
PLoS One ; 16(3): e0248300, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33690664

RESUMO

The Monte Carlo method was employed to simulate realistic treatment situations for photon and proton radiation therapy for a set of Oak Ridge National Laboratory (ORNL) pediatric phantoms for 15, 10, 5 and 1-year olds as well as newborns. Complete radiotherapy situations were simulated using the previously developed NRUrad input code for Monte Carlo N-Particle (MCNP) code package. Each pediatric phantom was irradiated at five different positions, namely, the testes, colon, liver, left lung and brain, and the doses in targeted organs (Dt) were determined using the track length estimate of energy. The dispersed photon and proton doses in non-targeted organs (Dd), namely, the skeleton, skin, brain, spine, left and right lungs were computed. The conversion coefficients (F = Dd/Dt) of the dispersed doses were used to study the dose dispersion in different non-targeted organs for phantoms for 15, 10, 5 and 1-year olds as well as newborns. In general, the F values were larger for younger patients. The F values for non-targeted organs for phantoms for 1-year olds and newborns were significantly larger compared to those for other phantoms. The dispersed doses from proton radiation therapy were also found to be significantly lower than those from conventional photon radiation therapy. For example, the largest F values for the brain were 65.6% and 0.206% of the dose delivered to the left lung (P4) for newborns during photon and proton radiation therapy, respectively. The present results demonstrated that dispersion of photons and generated electrons significantly affected the absorbed doses in non-targeted organs during pediatric photon therapy, and illustrated that proton therapy could in general bring benefits for treatment of pediatric cancer patients.


Assuntos
Modelos Teóricos , Imagens de Fantasmas , Terapia com Prótons , Doses de Radiação , Adolescente , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos
8.
Phys Med ; 76: 177-181, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32693354

RESUMO

In order to address the recent concerns over a possible increasing in brain tumour mortality among interventional radiologists and cardiologist, this work evaluated the exposure conditions of the operator's brain during interventional procedures using Monte Carlo simulations with anthropomorphic phantoms. The absorbed doses in several predefined segments of the operator's brain were estimated in a typical interventional radiology irradiation scenario. The doses were normalized to the KAP values simulated for ten X-ray beam qualities and four projections (PA, RAO 25°, LAO 25° and CRA 25°). For the interventional radiology scenario, because of the position of the operator, no difference was found in the exposure between the left and right regions of the brain for the first operator. However, for the second operator standing at a farer distance from the tube, the exposure of the left part of the brain is up to two times higher than that of the right part. The results are in agreement with dose measurements reported in the literature. The conversion factors, obtained as the absorbed dose per KAP, can be used to obtain a first estimate of the exposure of the brain of the operators during interventional procedures.


Assuntos
Exposição Ocupacional , Radiologia Intervencionista , Encéfalo/diagnóstico por imagem , Método de Monte Carlo , Exposição Ocupacional/análise , Imagens de Fantasmas , Doses de Radiação
9.
J Radiol Prot ; 39(1): 97-112, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30523896

RESUMO

In fluoroscopy guided interventional procedures, workers use protective garments and often two personal dosemeters, the readings of which are used for the estimation of the effective dose; whereas the dosemeter above the protection can be used for the estimation of the equivalent dose of the lens of the eye. When a protective apron is worn the scattered field that reaches the dosemeter is different from the case where no protection is used; this study analyses the changes in the response of seven passive and eight active personal dosemeters (APDs) when they are placed above a lead or lead equivalent garment for S-Cs and x-ray diagnostic qualities. Monte Carlo simulations are used to support the experimental results. It is found that for passive dosemeters, the influence on the dosemeter's response to the lead or lead equivalent was within the range 15%-38% for the x-ray qualities. This effect is smaller, of the order of 10%, when lead-free garments are used, and much smaller, within 1%-10%, for most of the APDs used in the study. From these results it is concluded that when comparing passive and active dosemeter measurements worn above the protection, a difference of 20%-40% is expected. The effect is small when deriving the effective dose from double dosimetry algorithms, but it can be of major importance when eye lens monitoring is based on the use of the dosemeter worn above the protection.


Assuntos
Cateterismo Cardíaco , Roupa de Proteção , Dosímetros de Radiação , Proteção Radiológica/métodos , Radiografia Intervencionista , Humanos
10.
Med Phys ; 45(12): 5577-5585, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30291717

RESUMO

PURPOSE: Neuroendocrine tumors (NETs) are now routinely treated by radiopeptide targeted therapy using somatostatin receptor-binding peptides such as 90 Y- and 177 Lu-DOTATOC. The objective of this work was to develop a biokinetics model of 90 Y labelled DOTATOC, which is applied in the therapy of NETs to estimate doses in kidney and tumor. METHODS: A multi-compartment model described by two sets of differential equations, one set for the actual 30-min infusion and the other set for the post-infusion period was developed and activities were measured by liquid scintillation counting in blood (compartment 1) and the urine (compartment 3). The inter-compartment transfer coefficients, λij , were varied to yield the best fit of the calculated to the measured time-activity data and the 90 Y-DOTATOC time-activity data in the five-compartments comprising the human body were thus determined. The resulting time-activity curves were integrated over the interval from 0 to 72 h post administration to obtain the number of radioactive decays in each compartment and, in case of the kidneys and tumor, then multiplied by the self-dose 90 Y beta particle absorbed fraction, determined by Monte Carlo (MC) simulation, the kidney and tumor absorbed doses. RESULTS: Transfer coefficients λij , were determined for five-compartments for all patients. Time- activity curves of 90 Y-DOTATOC in 14 patients were determined, and two typical ones are shown graphically. Absorbed doses in the tumor and kidneys, obtained by the developed method, were determined. The mean absorbed dose in a kidney per unit of administered activity is 1.43 mGy/MBq (range 0.73-2.42 mGy/MBq). The tumor dose was determined as 30.94 mGy/MBq (range 20.05-42.31 mGy/MBq). CONCLUSION: Analytical solution of a biokinetic model for 90 Y-DOTATOC therapy enabled determination of the transfer coefficients and derivation of time-activity curves and kidney and tumor absorbed doses for 14 treated patients. The model can be applied to other radionuclides where elimination is predominantly through urine, which is often the case in radiopharmaceuticals.


Assuntos
Modelos Biológicos , Tumores Neuroendócrinos/radioterapia , Octreotida/análogos & derivados , Radioisótopos de Ítrio/uso terapêutico , Adulto , Idoso , Feminino , Humanos , Rim/efeitos da radiação , Masculino , Pessoa de Meia-Idade , Método de Monte Carlo , Octreotida/uso terapêutico , Dosagem Radioterapêutica
11.
J Radiol Prot ; 36(4): 902-921, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27861170

RESUMO

Interventional radiology and cardiology guarantee high benefits for patients, but are known to be associated with a high level of radiation exposure of medical staff. The recently suggested decrease of the annual dose limit for the eye lens, from 150 to 20 mSv, caused a need for a reconsideration of practices ensuring sufficient protection for the lens of the eyes of medical staff. In such context the study of the scattered radiation around the operator's head could help in finding the best solutions to be adopted for the ceiling-suspended shield and lead glasses in the most common situations in interventional practices. MCNPX Monte Carlo code was employed with anthropomorphic mathematical phantoms to simulate interventional practice projections. For each projection the effect of changing selected parameters on the evaluated scattered radiation towards the operator's head has been calculated. The variety of modelled situations provides plentiful material regarding the spatial distribution of the scattered radiation, useful to improve eye lens radiation protection, such as the following:  (a) Glasses, which provide shielding from both lateral and bottom-up scattered radiation, can reduce by ten times the exposure to the most exposed eyes;  (b) The ceiling-suspended shield offers valuable protection, but such effectiveness can diminish by 90% if the shielding is not correctly positioned;  (c) The transition from femoral to radial access usually intensifies the scattered radiation toward the operator head (a factor of 1.5 for AP projection), but for RAO projections, a reduction of the order by two to three times, in the case of radial access, can be seen, due to the protection provided by the image receptor. The detailed fluence outcomes show that there is a preferential direction of the impinging scattered radiation that should be considered when radiation protection options are evaluated or when a dedicated eye lens dosemeter is used for monitoring.


Assuntos
Cristalino/efeitos da radiação , Corpo Clínico Hospitalar , Proteção Radiológica/métodos , Radiologia Intervencionista , Radiometria/métodos , Dispositivos de Proteção dos Olhos , Humanos , Método de Monte Carlo , Exposição Ocupacional/prevenção & controle , Imagens de Fantasmas , Exposição à Radiação , Lesões por Radiação/prevenção & controle , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA