Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Rinsho Shinkeigaku ; 64(6): 398-402, 2024 Jun 27.
Artigo em Japonês | MEDLINE | ID: mdl-38797688

RESUMO

A 78-year-old man complained of subacute general fatigue and anorexia, following diplopia and gait disturbance. He demonstrated wide-based and small-stepped gait without objectively abnormal ocular movements. Brain |MRI showed enlargement of the pituitary stalk and gland with uniform contrast enhancement. PET-CT showed FDG |uptake in the pituitary gland, mediastinal lymph nodes, and left hilar lymph nodes. Blood investigations revealed panhypopituitarism and high serum IgG4 levels up to 265 |mg/dl. Histopathological examination revealed no IgG4-positive cell infiltration in the biopsied mediastinal lymph nodes. However, we suspected IgG4-associated hypophysitis based on the clinical symptoms and MRI findings, which were markedly resolved with steroid. Central masked diabetes insipidus was manifested, but was improved with oral desmopressin. We should pay close attention to the fact that IgG4-related hypophysitis may present with various symptoms regarded as indefinite complaints related to aging or underlying diseases, especially in elderly patients with multimorbidity.


Assuntos
Diabetes Insípido Neurogênico , Hipopituitarismo , Imunoglobulina G , Humanos , Masculino , Idoso , Hipopituitarismo/diagnóstico , Hipopituitarismo/etiologia , Hipopituitarismo/imunologia , Diabetes Insípido Neurogênico/etiologia , Diabetes Insípido Neurogênico/diagnóstico , Imunoglobulina G/sangue , Desamino Arginina Vasopressina/administração & dosagem , Imageamento por Ressonância Magnética , Hipofisite Autoimune/complicações , Hipofisite Autoimune/diagnóstico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Hipofisite/diagnóstico , Hipofisite/complicações , Hipofisite/diagnóstico por imagem , Biomarcadores/sangue , Doença Relacionada a Imunoglobulina G4/complicações , Doença Relacionada a Imunoglobulina G4/diagnóstico , Resultado do Tratamento
2.
Intern Med ; 60(24): 3953-3956, 2021 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-34121012

RESUMO

A 23-year-old woman was transferred to our hospital due to exacerbating dyspnea with wheeze. After admission, we started mechanical ventilation immediately, and she was diagnosed with status asthmatics. On the following day, she was able to be weaned from the ventilator. However, she required re-intubation because of an unstable respiratory condition just after extubation. Detailed neurological investigations identified blepharoptosis and muscle weakness with easy fatigability. An edrophonium test was positive. Anti-acetylcholine receptor antibody was detected in her serum. She was finally diagnosed with myasthenia gravis and successfully treated with neostigmine and a low-dose corticosteroid.


Assuntos
Miastenia Gravis , Corticosteroides , Adulto , Autoanticorpos , Feminino , Humanos , Miastenia Gravis/complicações , Miastenia Gravis/diagnóstico , Miastenia Gravis/tratamento farmacológico , Receptores Colinérgicos , Respiração Artificial , Adulto Jovem
3.
Nucl Med Commun ; 42(9): 1052-1059, 2021 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-34001828

RESUMO

OBJECTIVE: This study aimed to evaluate the distribution of Astatine-211 (211At) solution dispersion in a small animal cage using autoradiography imaging to simulate the dispersion of 211At in a lab room to eventually prevent user's risk of internal exposure in terms of radiation safety. METHODS: 211At radiation sources with two chemical properties (Na211At and Free 211At) were prepared. The solutions of 211At were placed onto a dish with paper, and then, it was placed in a small animal cage for 3 h. After removing the dish, an imaging plate with attaching reference sources was placed at four walls of the cage for 15 h in a lead box. Imaging plates were read, and all pixel data were calculated using Microsoft Excel 2016 to obtain three-dimensional (3D) distribution. Calculated results were depicted using a 3D sphere model. RESULTS: The mean activity of Free 211At was 2.3 times higher than that of Na211At on all autoradiography images. In the cage, the shape of the dispersion of Na211At was almost homogeneous, whereas that of Free 211At was more heterogeneous. CONCLUSION: We found that the solution of 211At vaporized naturally and was distributed heterogeneously in the cage, and the chemical properties of 211At influenced their behaviors. These results must be considered to minimize the risks of radiation safety.


Assuntos
Astato , Radioimunoterapia , Autorradiografia , Humanos
4.
Ann Nucl Med ; 35(4): 421-428, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33502738

RESUMO

OBJECTIVES: Measurement of cerebral blood flow (CBF), cerebral blood volume (CBV), cerebral oxygen extraction fraction (OEF) and cerebral metabolic rate of oxygen (CMRO2) by PET with oxygen-15 labeled gases is useful for diagnosis and treatment planning in cases of chronic occlusive cerebrovascular disease. In the present study, CBF, CBV, OEF and CMRO2 were measured using the integrated design of PET/MRI scanner system. This is a first attempt to measure cerebral perfusion and oxygen metabolism using PET/MRI with oxygen-15 labeled gases. METHODS: PET/MRI measurements with the steady-state method of oxygen-15 labeled gases, carbon monoxide (C15O), oxygen (15O2), and carbon dioxide (C15O2) were performed on nine healthy men. Two kinds of attenuation correction for PET were performed using MRI with Dixon sequence (DIXON) and Dixon sequence with model-based bone segmentation (DIXONbone). A real-time motion correction of PET images was also performed using simultaneously measured MR images to detect head motion. RESULTS: Mean and SD values of CBF, CBV, OEF, and CMRO2 in the cerebral cortices with attenuation correction by DIXON were 31 ± 4 mL/100 mL/min, 2.7 ± 0.2 mL/mL, 0.40 ± 0.07, and 2.5 ± 0.3 mL/100 mL/min without real-time motion correction, and 33 ± 4 mL/100 mL/min, 2.7 ± 0.2 mL/mL, 0.40 ± 0.07, and 2.6 ± 0.3 mL/100 mL/min with real-time motion correction, respectively. Values with of CBF, CBV, OEF, and CMRO2 with attenuation correction by DIXONbone were 35 ± 5 mL/100 mL/min, 2.8 ± 0.2 mL/mL, 0.40 ± 0.07, and 2.8 ± 0.3 mL/100 mL/min without real-time motion correction, and 38 ± 5 mL/100 mL/min, 2.8 ± 0.2 mL/mL, 0.40 ± 0.07, and 3.0 ± 0.4 mL/100 mL/min with real-time motion correction, respectively. CONCLUSIONS: Using PET/MRI with oxygen-15 labeled gases, CBF, CBV, OEF, and CMRO2 could be measured. Values of CBF, CBV, and CMRO2 measured with attenuation correction by DIXON were significantly lower than those measured with correction by DIXONbone. One of the reasons for this is that attenuation correction of DIXON does not take into consideration of the photon absorption by bone. OEF values, corresponding to ratios of CMRO2 to CBF, were not affected by attenuation correction methods. Values of CBF and CMRO2 with a real-time motion correction were significantly higher than those without correction. Using PET/MRI with adequate corrections, similar values of CBF, CBV, OEF, and CMRO2 as PET alone scanner system reported previously were obtained. TRAIL REGISTRATION: The UMIN clinical trial number: UMIN000033382.


Assuntos
Volume Sanguíneo Cerebral/fisiologia , Circulação Cerebrovascular/fisiologia , Transtornos Cerebrovasculares/diagnóstico , Metaboloma/fisiologia , Radioisótopos de Oxigênio/metabolismo , Adulto , Córtex Cerebral/metabolismo , Gases , Humanos , Imageamento por Ressonância Magnética , Masculino , Consumo de Oxigênio/fisiologia , Radioisótopos de Oxigênio/química , Tomografia por Emissão de Pósitrons
5.
EJNMMI Phys ; 7(1): 58, 2020 Sep 22.
Artigo em Inglês | MEDLINE | ID: mdl-32960387

RESUMO

BACKGROUND: 211At is one of the ideal nuclides for targeted radionuclide therapies (TRTs). Meta-[211At]astatobenzylguanidine (211At-MABG) has been proposed for the treatment of pheochromocytoma. To effectively use these radiopharmaceuticals, dosimetry must be performed. It is important to determine the absorbed doses of free 211At and 211At-MABG to determine the organs that may be at risk when using TRTs. The aim of this study was to estimate human dosimetry from preclinical biodistribution of free 211At and 211At-MABG in various organs in normal mice. METHODS: Male C57BL/6 N mice were administered 0.13 MBq of free 211At or 0.20 MBq of 211At-MABG by tail-vein injection. The mice were sacrificed at 5 min, and at 1, 3, 6, and 24 h after the injection (n = 5 for each group). The percentage of injected activity per mass in organs and blood (%IA/g) was determined. The human absorbed doses of free 211At and 211At-MABG were calculated using the Organ Level INternal Dose Assessment/EXponential Modeling (OLINDA/EXM) version 2.0 and IDAC-Dose 2.1. RESULTS: High uptake of free 211At was observed in the lungs, spleen, salivary glands, stomach, and thyroid. The absorbed doses of free 211At in the thyroid and several tissues were higher than those of 211At-MABG. The absorbed doses of 211At-MABG in the adrenal glands, heart wall, and liver were higher than those of free 211At. CONCLUSIONS: The absorbed doses of 211At-MABG in organs expressing the norepinephrine transporter were higher than those of free 211At. In addition, the biodistribution of free 211At was different from that of 211At-MABG. The absorbed dose of free 211At may help predict the organs potentially at risk during TRTs using 211At-MABG due to deastatination.

6.
Phys Med ; 76: 221-226, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32717701

RESUMO

PURPOSE: This study aimed to compare two methods of assessing the half-value layer (HVL) for computed tomography scanners in a single-rotation technique with and without lead apertures (SRTLA / SRT). METHODS: A 0.6 cc real-time ionization chamber was suspended freely in the air at the isocenter, and six sheets of lead (130 × 170 × 2 mm) were placed at the bottom of the gantry cover, forming five apertures each having a width of 16 mm (SRTLA geometry). Four aluminum plates (100 × 100 mm2; 2.0, 4.0, 6.0, and 8.0 mm thick) were placed on these apertures. Air-kerma rate profiles (K̇air) in the spiral mode were measured at tube potentials of 80, 100, 120, and 135 kVp, a tube current of 100 mA, a nominal beam width of 32.0 mm, and a rotation time of 1.5 s. Thereafter, all lead sheets were removed, and these same measurements were taken to investigate the errors of the HVLs (SRT geometry). HVLs using the SRTLA and SRT were compared with those obtained through a conventional localization technique. RESULTS: The HVLs measured in the SRTLA/SRT at 80, 100, 120, and 135 kVp were 3.37/3.50, 4.24/4.47, 5.22/5.44, and 5.90/6.17 mm, respectively. The differences between these values and those obtained through the conventional technique were 0.09/0.22, 0.02/0.25, 0.05/0.27, and -0.01/0.26 mm, respectively. CONCLUSIONS: The accuracies of the HVLs of the SRTLA were similar to those of the conventional technique. The lead apertures under the aluminum plates would help reduce the number of inaccurate HVL measurements.


Assuntos
Alumínio , Tomografia Computadorizada por Raios X , Doses de Radiação , Rotação , Raios X
7.
J Comput Assist Tomogr ; 43(4): 664-670, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31259851

RESUMO

PURPOSE: To assess the diagnostic ability of whole-body magnetic resonance imaging (MRI) using integrated positron emission tomography/MRI(PET/MRI). METHODS: Axial T2-weighted image (T2WI), diffusion-weighted imaging (DWI), coronal T1-weighted image (T1WI), axial volumetric interpolated breath-hold examination in the lung field, and 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG-PET) were evaluated in combination with T2WI alone, T2WI + DWI, T2WI + DWI + T1WI, T2WI + DWI + T1WI + volumetric interpolated breath-hold examination (all MRI images), and all MRI + FDG-PET. RESULTS: A total of 370 lesions were observed in 90 (62.5%) of the 144 patients. The lesion-based sensitivities were 62%, 74%, 74%, 76%, and 94%, and the patient-based sensitivities were 70%, 77%, 77%, 77%, and 81% using T2WI, T2WI + DWI, T2WI + DWI + T1WI, all MRI, and all MRI + FDG-PET, respectively. There were significant differences in the lesion-based sensitivity between T2WI and other sequence combinations and between all MRI and all MRI + FDG-PET. No significant differences were observed between any combinations among the patient-based sensitivities. CONCLUSION: The sensitivity of whole-body MRI was lower when lesion based, but almost equivalent when patient based compared with PET/MRI.


Assuntos
Imageamento por Ressonância Magnética/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons/métodos , Imagem Corporal Total/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Feminino , Fluordesoxiglucose F18/uso terapêutico , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Estudos Retrospectivos , Sensibilidade e Especificidade , Adulto Jovem
8.
Oncotarget ; 8(33): 55230-55245, 2017 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-28903416

RESUMO

Metastatic renal cell carcinoma (RCC) is a tumor entity with poor prognosis due to limited therapy options. Tyrosine kinase inhibitors (TKI) represent the standard of care for RCCs, however a significant proportion of RCC patients develop resistance to this therapy. Interleukin-6 (IL-6) is considered to be associated with poor prognosis in RCCs. We therefore hypothesized that TKI resistance and IL-6 secretion are causally connected. We first analyzed IL-6 expression after TKI treatment in RCC cells and RCC tumor specimens. Cell proliferation and signal transduction activity were then quantified after co-treatment with tocilizumab, an IL-6R inhibitor, in vitro and in vivo. 786-O RCC cells secrete high IL-6 levels after low dose stimulation with the TKIs sorafenib, sunitinib and pazopanib, inducing activation of AKT-mTOR pathway, NFκB, HIF-2α and VEGF expression. Tocilizumab neutralizes the AKT-mTOR pathway activation and results in reduced proliferation. Using a mouse xenograft model we can show that a combination therapy with tocilizumab and low dosage of sorafenib suppresses 786-O tumor growth, reduces AKT-mTOR pathway and inhibits angiogenesis in vivo more efficient than sorafenib alone. Furthermore FDG-PET imaging detected early decrease of maximum standardized uptake values prior to extended central necrosis. Our findings suggest that a combination therapy of IL-6R inhibitors and TKIs may represent a novel therapeutic approach for RCC treatment.

9.
Sci Rep ; 7(1): 3953, 2017 06 21.
Artigo em Inglês | MEDLINE | ID: mdl-28638087

RESUMO

Multimodal imaging using novel multifunctional nanoparticles provides new approach to biomedical field. Thiol-organosilica nanoparticles containing iron oxide magnetic nanoparticles (MNPs) and rhodamine B (thiol OS-MNP/Rho) were applied to multimodal imaging of hepatic tumor of Long-Evans Cinnamon (LEC) rat. The magnetic resonance imaging (MRI) of LEC rats revealed tumors in the liver clearly and semi-quantitatively due to a labeling of macrophages in liver. The fluorescent imaging (FI) showed abnormal fluorescent patterns of the liver at the mesoscopic level that was between macroscopic and microscopic level. We performed correlation analysis between optical imaging including FI and MRI. We found that the labeled macrophages located specific area in the tumor tissue and influenced the tumor size on MRI. In addition histological observation showed the labeled macrophages related specific tissue in the pathological region. We demonstrated a new approach to evaluate tumor tissue at the macroscopic and microscopic level as well as mesoscopic level using multimodal imaging.


Assuntos
Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Nanopartículas de Magnetita , Imagem Multimodal/métodos , Animais , Compostos Férricos/química , Processamento de Imagem Assistida por Computador , Macrófagos/patologia , Imageamento por Ressonância Magnética/métodos , Nanopartículas de Magnetita/química , Nanotecnologia , Imagem Óptica/métodos , Ratos Endogâmicos LEC , Rodaminas/química
10.
J Colloid Interface Sci ; 492: 127-135, 2017 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-28086116

RESUMO

Multimodal imaging using novel multifunctional nanoparticles provides a new approach for the biomedical field. Thiol-organosilica nanoparticles containing iron oxide magnetic nanoparticles (MNPs) as the core and rhodamine B in the thiol-organosilica layer (thiol OS-MNP/Rho) were synthesized in a one-pot process. The thiol OS-MNP/Rho showed enhanced magnetic resonance imaging (MRI) contrast and high fluorescence intensity. The relaxometry of thiol OS-MNP/Rho revealed a novel coating effect of the organosilica layer to the MNPs. The organosilica layer shortened the T2 relaxation time but not the T1 relaxation time of the MNPs. We injected thiol-OS-MNP/Rho into normal mice intravenously. Injected mice revealed an alteration of the liver contrast in the MRI and a fluorescent pattern based on the liver histological structure at the level between macroscopic and microscopic fluorescent imaging (mesoscopic FI). In addition, the labeled macrophages were observed at the single cell level histologically. We demonstrated a new approach to evaluate the liver at the macroscopic, microscopic level as well as the mesoscopic level using multimodal imaging.


Assuntos
Imageamento por Ressonância Magnética/métodos , Imagem Multimodal/métodos , Nanopartículas/química , Imagem Óptica/métodos , Compostos de Organossilício , Animais , Compostos Férricos/química , Corantes Fluorescentes/química , Magnetismo , Nanopartículas de Magnetita/química , Camundongos , Microscopia de Fluorescência , Compostos de Organossilício/química
11.
Jpn J Radiol ; 34(11): 754-762, 2016 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-27714486

RESUMO

Although PET/MRI has the advantages of a simultaneous acquisition of PET and MRI, high soft-tissue contrast of the MRI images, and reduction of radiation exposure, its low profitability and long acquisition time are significant problems in clinical settings. Thus, MRI protocols that meet oncological purposes need to be used in order to reduce examination time while securing detectability. Currently, half-Fourier acquisition single-shot turbo spin echo and 3D-T1 volumetric interpolated breath-hold examination may be the most commonly used sequences for whole-body imaging due to their shorter acquisition time and higher diagnostic accuracy. Although there have been several reports that adding diffusion weighted image (DWI) to PET/MRI protocol has had no effect on tumor detection to date, in cases of liver, kidney, bladder, and prostate cancer, the use of DWI may be beneficial in detecting lesions. Another possible option is to scan each region with different MRI sequences instead of scanning the whole body using one sequence continuously. We herein report a workflow and imaging protocols for whole-body oncologic PET/MRI using an integrated system in the clinical routine, designed for the detection, for example by cancer screening, of metastatic lesions, in order to help future users optimize their workflow and imaging protocols.


Assuntos
Imageamento por Ressonância Magnética , Imagem Multimodal/métodos , Neoplasias/diagnóstico por imagem , Tomografia por Emissão de Pósitrons , Imagem Corporal Total/métodos , Fluxo de Trabalho , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Compostos Radiofarmacêuticos , Sensibilidade e Especificidade
12.
Kyobu Geka ; 68(5): 323-8; discussion 328-31, 2015 May.
Artigo em Japonês | MEDLINE | ID: mdl-25963778

RESUMO

Nipro paracorporeal ventricular assist device( VAD) is often associated with pump thrombosis which causes severe complications such as brain infarction, often requiring pump change. However, Nipro VAD pump is an expensive device and it is difficult to change pumps frequently at a short interval. We have temporarily used Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs. From January 2012 through December 2013, 19 patients underwent Nipro VADs implantation at our institution, and 9 of them underwent pump change from Nipro pumps to Rotaflow centrifugal pumps. A total of 25 Rotaflow centrifugal pumps were used in these 9 patients, with the total circulatory support duration of 526 days. The median support period was 15 days (range;2-128 days). There were 2 cerebrovascular accidents and 1 Rotaflow pump circuit thrombosis during this period. Change from Rotaflow to Nipro VAD pump resulted in decrease in hematocrit by about 3 point. There was no difference in liver or renal function between before and after the pump change. Our results suggest that temporary use of Rotaflow centrifugal pump for recurrent pump thrombosis in patients with Nipro VADs may be a promising alternative.


Assuntos
Centrifugação/instrumentação , Coração Auxiliar , Trombose/terapia , Adolescente , Adulto , Centrifugação/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
13.
Oncol Rep ; 31(5): 2007-14, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24604559

RESUMO

Positron emission tomography-computed tomography (PET-CT) with [18F] fluorodeoxyglucose (FDG) has recently been applied for evaluating tumor response to anticancer therapy. The aim of the present study was to evaluate the utility of FDG PET-CT in monitoring non-invasively and repeatedly the inhibitory effect of cisplatin (CDDP) on an orthotopic lung cancer model. Validation of in vivo FDG uptake in human lung cancer Ma44-3 cell line in an orthotopic SCID mouse model was carried out. Next, we assessed the use of FDG PET-CT to monitor the response of orthotopic lung cancer to the anticancer effect of CDDP. SCID mice were divided into the CDDP group (7 mg/kg single dose intraperitoneally) and the control group. Tumor volume and maximal standardized uptake value (SUV max) were calculated for all mice. All mice were sacrificed for histopathologic analysis. Validation of FDG PET-CT showed that tumor volume and SUV max were significantly correlated with postmortem tumor length measured in specimens (P=0.023) and (P=0.012), respectively, and there was a significant correlation between SUV max and tumor volume (P=0.048). Response monitoring showed that significant growth inhibition by CDDP in the form of SUV max of the CDDP group was significantly lower than that of the control group on day 8 (P=0.02) and on day 13 (P=0.003). Tumor volume of the CDDP group was significantly lower than that of the control group on day 13 (P=0.03). The present study supports using FDG PET-CT in monitoring tumor progression and therapeutic response of lung cancer in an orthotopic model non­invasively and repeatedly.


Assuntos
Antineoplásicos/uso terapêutico , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Cisplatino/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Tomografia por Emissão de Pósitrons , Animais , Carcinoma Pulmonar de Células não Pequenas/patologia , Linhagem Celular Tumoral , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/patologia , Masculino , Camundongos , Camundongos SCID , Imagem Multimodal , Tomografia Computadorizada por Raios X , Carga Tumoral
14.
Kyobu Geka ; 66(1): 51-6, 2013 Jan.
Artigo em Japonês | MEDLINE | ID: mdl-23985405

RESUMO

Two implantable left ventricular assist devices(I-LVADs)were approved in Japan in 2011. I-LVADs were used for end-stage heart failure of 20 patients in our institute until March 2012. We examine the clinical course of these 20 patients who were treated with I-LVADs. End points are transplantation, death, or weaning from I-LVADs. Mean hospital days after I-LVAD implantation were 58.1 days, and all 20 patients could discharge from hospital alive. Until September 2012, mean follow up interval was 515 days. Five patients reached heart transplantation, 2 died, weaning from an I-LVAD could be done in 1 patient, and 12 continued to wait for heart transplantation. Survival rate was 100% at 1 month, 95% at 3 months, and 89% at 1 year, respectively. Mean follow up duration after discharge were 457 days, and 16 patients(80%)needed a total of 41 times of readmission in this period. Freedom from readmission was 75% at 1 month, 60% at 3 months, and 25% at 1 year, respectively. In conclusion, prognosis of I-LVAD treatment was good, but many patients needed readmission after I-LVAD implantation and follow up system for I-LVAD treatment should be improved immediately.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Adulto , Feminino , Seguimentos , Insuficiência Cardíaca/mortalidade , Humanos , Tempo de Internação , Masculino , Pessoa de Meia-Idade , Readmissão do Paciente , Prognóstico
15.
J Artif Organs ; 15(2): 207-10, 2012 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-22358461

RESUMO

Since left heart bypass or biventricular circulatory assist with an extracorporeal centrifugal pump as a bridge to decision or recovery sometimes requires long-time support, the long-term durability of extracorporeal centrifugal pumps is crucial. The Rotaflow Centrifugal Pump(®) (MAQUET Cardiopulmonary AG, Hirrlingen, Germany) is one of the centrifugal pumps available for long-term use in Japan. However, there have been few reports of left heart bypass or biventricular circulatory support over the mid-term. This is a case report of left heart bypass support with the Rotaflow Centrifugal Pump(®) as a bridge to decision and recovery for an adult patient who could not be weaned from cardiopulmonary bypass and percutaneous cardiopulmonary support after cardiac surgery. We could confirm that the patient's consciousness level was normal; however, the patient could not be weaned from the left heart bypass support lasting 1 month. Therefore, the circulatory assist device was switched to the extracorporeal Nipro ventricular assist device (VAD). This time, left heart bypass support could be maintained for 30 days using a single Rotaflow Centrifugal Pump(®). There were no signs of hemolysis during left heart bypass support. The Rotaflow Centrifugal Pump(®) itself may be used as a device for a bridge to decision or recovery before using a VAD in cardiogenic shock patients.


Assuntos
Estenose da Valva Aórtica/cirurgia , Derivação Cardíaca Esquerda , Coração Auxiliar , Oxigenação por Membrana Extracorpórea , Evolução Fatal , Feminino , Humanos , Pessoa de Meia-Idade , Complicações Pós-Operatórias
16.
Brain Res ; 1429: 155-63, 2012 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-22079320

RESUMO

Repeated intermittent administration of amphetamines acutely increases appetitive and consummatory aspects of motivated behaviors as well as general activity and exploratory behavior, including voluntary running wheel activity. Subsequently, if the drug is withdrawn, the frequency of these behaviors decreases, which is thought to be indicative of dysphoric symptoms associated with amphetamine withdrawal. Such decreases may be observed after chronic treatment or even after single drug administrations. In the present study, the effect of acute methamphetamine (METH) on running wheel activity, horizontal locomotion, appetitive behavior (food access), and consummatory behavior (food and water intake) was investigated in mice. A multi-configuration behavior apparatus designed to monitor the five behaviors was developed, where combined measures were recorded simultaneously. In the first experiment, naïve male ICR mice showed gradually increasing running wheel activity over three consecutive days after exposure to a running wheel, while mice without a running wheel showed gradually decreasing horizontal locomotion, consistent with running wheel activity being a positively motivated form of natural motor activity. In experiment 2, increased horizontal locomotion and food access, and decreased food intake, were observed for the initial 3h after acute METH challenge. Subsequently, during the dark phase period decreased running wheel activity and horizontal locomotion were observed. The reductions in running wheel activity and horizontal locomotion may be indicative of reduced dopaminergic function, although it remains to be seen if these changes may be more pronounced after more prolonged METH treatments.


Assuntos
Comportamento Animal/efeitos dos fármacos , Estimulantes do Sistema Nervoso Central/administração & dosagem , Ritmo Circadiano/efeitos dos fármacos , Metanfetamina/administração & dosagem , Atividade Motora/efeitos dos fármacos , Animais , Escuridão , Luz , Masculino , Camundongos , Camundongos Endogâmicos ICR
17.
Jpn J Radiol ; 28(2): 173-9, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20182855

RESUMO

PURPOSE: The aim of this study was to select a suitable substrate candidate for dynamic nuclear polarization (DNP) studies and demonstrate its utility for evaluating intracellular metabolism. MATERIALS AND METHODS: Hyperpolarized substances included 1-(13)C-pyruvate (Pyr), 1-(13)C-glucose (Glc), and 1-(13)C-acetate. A DNP polarizer and a 600-MHz vertical small-bore scanner were used for (13)C-MR spectroscopic measurements. After polarization for 1 h, the dissolved solution was injected via a capillary line into the nuclear magnetic resonance tube in the scanner. The sequential spectra of the hyperpolarized (13)C-labeled substrates were acquired in durations of more than 120 s, and a thermal spectrum was obtained more than 1 h thereafter. FM3A cancer cells of mammary tumors were cultured for intracellular detection of the hyperpolarized (13)C-substances. RESULTS: The greatest sensitivity was found using Pyr with the longest T1 decay (51.5 s); and remarkably, the least sensitivity was observed using Glc with a signal decay of less than 2 s. An effective increase in sensitivity was shown using the other substances. The hyperpolarized intracellular study using (13)C-Pyr showed distinct elevation of lactate levels. CONCLUSION: The DNP technique is useful for evaluating intracellular metabolism. However, Glc is not suitable for use with the DNP technique.


Assuntos
Acetatos/metabolismo , Isótopos de Carbono/metabolismo , Glucose/metabolismo , Espectroscopia de Ressonância Magnética/métodos , Neoplasias Mamárias Experimentais/metabolismo , Ácido Pirúvico/metabolismo , Animais , Biomarcadores Tumorais/metabolismo , Linhagem Celular Tumoral/metabolismo , Células Cultivadas , Feminino , Aumento da Imagem/métodos , Camundongos , Camundongos Endogâmicos C3H , Sensibilidade e Especificidade
18.
Neuroimage ; 47(4): 1207-14, 2009 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-19481612

RESUMO

The purpose of this study was to estimate the gamma-aminobutyric acid (GABA) and glutamate plus glutamine (Glx) concentrations in the cortical tubers of patients with tuberous sclerosis complex (TSC) using the MEGA-editing J-difference method and a stimulated echo-acquisition mode with a short echo time, and to determine which abnormality was more dominant between GABA and Glx in patients with TSC with epilepsy. This study included six patients with TSC (mean age, 4.3 years) and seven control subjects (mean age, 4.8 years). Measurements were obtained with a three-Tesla apparatus and postprocessing was conducted with an LCModel. The GABA level in the cortical gray matter (cgGABA) was calculated as a result of segmentation in voxels and from the literature values for gray and white matter ratios for GABA. Increased GABA and myo-inositol (mI) concentrations and a decreased N-acetyl aspartate (NAA) concentration were observed in the cortical tubers. The cgGABA level, and cgGABA/NAA and cgGABA/Glx ratios were also higher in patients with TSC than in control subjects. No significant difference was found in Glx concentration between patients with TSC and control subjects. Although the number of patients with TSC in this study was small, the increase in GABA and no significant change in Glx were consistent with previous neurochemical studies and support the hypothesis that brain GABA plays a key role in the pathophysiology of epilepsy during the process of neuronal development.


Assuntos
Córtex Cerebral/metabolismo , Epilepsia/metabolismo , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Esclerose Tuberosa/metabolismo , Ácido gama-Aminobutírico/análise , Biomarcadores/análise , Córtex Cerebral/patologia , Criança , Pré-Escolar , Epilepsia/complicações , Epilepsia/patologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Distribuição Tecidual , Esclerose Tuberosa/complicações , Esclerose Tuberosa/patologia
19.
J Comput Assist Tomogr ; 32(3): 369-71, 2008.
Artigo em Inglês | MEDLINE | ID: mdl-18520539

RESUMO

OBJECTIVE: To evaluate the feasibility of magnetic resonance (MR) imaging at 3 T compared with 1.5 T while focusing on the shading sign of endometrial cysts on T2-weighted images. METHODS: Fifteen ovarian endometrial cysts in 10 patients underwent pelvic MR scans on 3-T and 1.5-T scanners. Fast spin-echo T2-weighted images were obtained. The images were evaluated qualitatively for the presence of the shading sign. Quantitative evaluation was performed by comparing the cyst-to-muscle signal intensity ratio at 3 T and that at 1.5 T. RESULTS: The signal intensity of the cysts was lower at 3 T than that at 1.5 T by visual evaluation. In 2 lesions, the shading sign was demonstrated at 3 T but was not at 1.5 T. The cyst-to-muscle signal intensity ratio at 3 T was significantly lower than that at 1.5 T. CONCLUSION: Magnetic resonance imaging at 3 T is useful for the diagnosis of endometrial cysts with better demonstration of the shading sign on T2-weighted images.


Assuntos
Endometriose/diagnóstico , Imageamento por Ressonância Magnética/métodos , Doenças Ovarianas/diagnóstico , Adulto , Idoso , Estudos de Viabilidade , Feminino , Humanos , Pessoa de Meia-Idade , Estudos Prospectivos
20.
Radiat Med ; 26(1): 15-20, 2008 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18236129

RESUMO

PURPOSE: The aim of this study was to compare diffusion-weighted imaging (DWI) at 3.0 T and 1.5 T by evaluating the apparent diffusion coefficient (ADC) value and visibility of breast cancer in the same patients. MATERIALS AND METHODS: A total of 13 patients (16 lesions) with breast cancer underwent DWI at 3.0 T and 1.5 T. Tumors were classified into two groups based on the lesion size. The ADC values were measured, and visibility of the tumors was scored blindly. RESULTS: No significant difference was found for ADC values between 3.0 T and 1.5 T in either group (P > 0.05). All of the large lesions were visible clearly at both magnetic field strengths, and image scores were not different (P > 0.05). In contrast, small lesions were more clearly visible and had better image scores at 3.0 T than at 1.5 T (P < 0.001). CONCLUSION: Small cancers were more clearly visible on DWI at 3.0 T than 1.5 T.


Assuntos
Neoplasias da Mama/diagnóstico , Imagem de Difusão por Ressonância Magnética/métodos , Neoplasias da Mama/patologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA