Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 40
Filtrar
1.
PLoS One ; 17(11): e0276447, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36327325

RESUMO

OBJECTIVES: Delirium is an important prognostic factor in postoperative patients undergoing cardiovascular surgery and intervention, including transcatheter aortic valve implantation (TAVI). However, delirium after transcatheter aortic valve implantation (DAT) is difficult to predict and its pathophysiology is still unclear. We aimed to investigate whether preoperative cerebral blood flow (CBF) is associated with DAT and, if so, whether CBF measurement is useful for predicting DAT. METHODS: We evaluated CBF in 50 consecutive patients before TAVI (84.7±4.5 yrs., 36 females) using 99mTc ethyl cysteinate dimer single-photon emission computed tomography. Preoperative CBF of the DAT group (N = 12) was compared with that of the non-DAT group (N = 38) using whole brain voxel-wise analysis with SPM12 and region of interest-based analysis with the easy-Z score imaging system. Multivariable logistic regression analysis with the presence of DAT was used to create its prediction model. RESULTS: The whole brain analysis showed that preoperative CBF in the insula was lower in the DAT than in the non-DAT group (P<0.05, family-wise error correction). Decrease extent ratio in the insula of the DAT group (17.6±11.5%) was also greater relative to that of the non-DAT group (7.0±11.3%) in the region of interest-based analysis (P = 0.007). A model that included preoperative CBF in the insula and conventional indicators (frailty index, short physical performance battery and mini-mental state examination) showed the best predictive power for DAT (AUC 0.882). CONCLUSIONS: These results suggest that preoperative CBF in the insula is associated with DAT and may be useful for its prediction.


Assuntos
Estenose da Valva Aórtica , Delírio , Substituição da Valva Aórtica Transcateter , Feminino , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Tomografia Computadorizada de Emissão de Fóton Único , Encéfalo/irrigação sanguínea , Delírio/diagnóstico por imagem , Delírio/etiologia , Perfusão , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Resultado do Tratamento , Fatores de Risco
2.
J Thorac Dis ; 14(1): 76-89, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35242370

RESUMO

BACKGROUND: Although the incident rate is low, sternal dislocation and dehiscence due to unstable sternal fixation after cardiovascular surgery could cause potentially lethal complications. Thus, to enforce the stability of closed sternum, the sternal pins have been utilized at surgeon's discretion. However, there is no randomized clinical trial to test whether these pins are effective to stabilize a sternum. Hence, this study aimed to examine the clinical efficacy of bioabsorbable poly-L-lactide (PLLA) sternal pins in reinforcing sternal stability and preventing instability of the sternum after full sternotomy. METHODS: We conducted a single institutional, prospective, randomized, single-blinded clinical study involving 100 patients who underwent an initial cardiovascular surgery via sternotomy. Patients were randomly allocated into two groups: with (group P) and without (group N) PLLA sternal pins, at 1:1 ratio from November 2013 to April 2016. Sternal deviation and stability were assessed with postoperative computed tomography (CT) at two postures to put shear stress on the sternum. Additionally, information on patient demographic indices was obtained prospectively, and patient's pain intensity was assessed with numerical rating scoring system during rehabilitation. Furthermore, propensity score matching was performed for further comparative sub-analysis. RESULTS: Ninety-one patients (43 in group P and 48 in group N) were analyzed using the intention-to-treat method. Group N had a significantly higher proportion of males (P=0.015) and ischemic disease as a primary diagnosis (P=0.040) than group P. Postoperative CT showed that the degree of sternal deviation and stability were comparable between the groups. Similarly, the numerical rating score of pain during rehabilitation showed no difference between the groups. Even after adjusting for patient characteristics using propensity score matching method, no significant differences in sternal gaps, stability, and numerical rating score of pain were observed. Of note, no material-related adverse event such as wound infection was found. CONCLUSIONS: We could not identify the efficacy of the sternal pin in enforcing sternal stability based on CT measurements with mild shear stress on sternum after cardiovascular surgery. Nevertheless, our results with no adverse events might encourage further investigations with a more specific cohort who is susceptible to infection but requires an additional sternal fixation. TRIAL REGISTRATION: This study was registered in University Hospital Medical Information Network Clinical Trial Registry (UMIN000017357).

3.
Kyobu Geka ; 74(11): 945-949, 2021 Oct.
Artigo em Japonês | MEDLINE | ID: mdl-34601479

RESUMO

An anomalous origin of the right coronary artery from the pulmonary artery (ARCAPA) is a rare congenital disease, and it sometimes remains unnoticed until cardiac symptoms appear in adulthood. We report an adult case of surgically treated ARCAPA. A 72-year-old male was diagnosed with ARCAPA by examination for heart failure. The origin of the right coronary artery (RCA) was dilated, and ischemic change was found in the RCA area by myocardial scintigraphy. Therefore, coronary artery bypass grafting to distal RCA was performed at first, then the fistula was closed using an autologous pericardial patch, and the dilated origin of RCA was resected. Postoperative scintigraphy showed disappearance of the ischemic pattern, and the patient was discharged without any symptom of heart failure.


Assuntos
Anomalias dos Vasos Coronários , Fístula , Adulto , Idoso , Ponte de Artéria Coronária , Anomalias dos Vasos Coronários/diagnóstico por imagem , Anomalias dos Vasos Coronários/cirurgia , Humanos , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/cirurgia
4.
Kyobu Geka ; 73(9): 652-661, 2020 Sep.
Artigo em Japonês | MEDLINE | ID: mdl-32879267

RESUMO

We evaluated the blood pressure( BP) lowering effect and possible suppression of aortic enlargement by olmesartan (OLM) in patients with thoracic and thoracoabdominal aortic aneurysm. In this single center prospective, forced titration study, 50 patients were registered between 2008 and 2011. After all patients received any of OLM 10, 20, and 40 mg/day as an initial dose, the dosage of OLM was titrated up to 40 mg as needed during follow-up period. Home BP (HBPs), aortic aneurysm size assessed by computed tomography (CT) scan, indices of renal function were recorded at 3- and 6-months follow-up. Depending on whether 40 mg/day of prescription was continued for more than 4 months or not, the patients were divided into 2 groups:less than 40 mg (<40 mg) and 40 mg groups. Morning HBPs tended to decrease in both groups, and the percent changes in BPs were essentially the same regardless of dosage. The absolute value of aortic diameter tended to slightly enlarge only in <40 mg group. Also in the <40 mg group, the absolute differences in aortic diameter between those at the time of study registration and each follow-up were 0.5±1.8 mm at 3-month and 1.2±2.3 mm at 6-month (p=0.047),whereas the percent changes were 0.9±3.3% and 2.2±4.5% at 3 and 6 months, respectively( p=0.058). As for 40 mg group, the absolute differences and percent changes did not reach statistically significant increase during the follow-up period. No severe renal dysfunction related to OLM 40 mg prescription was observed. Our results imply that OLM 40 mg may suppress aortic aneurysmal dilation independently of blood pressure lowering effect. Further study with larger number of sample size is warranted to assure this observation.


Assuntos
Aneurisma da Aorta Torácica , Hipertensão , Anti-Hipertensivos/uso terapêutico , Dilatação , Humanos , Imidazóis , Olmesartana Medoxomila , Estudos Prospectivos , Tetrazóis
5.
Gen Thorac Cardiovasc Surg ; 68(11): 1240-1251, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32372277

RESUMO

OBJECTIVE: To investigate the efficacy of prophylactic administration of low-dose landiolol on postoperative atrial fibrillation (POAF) in patients after cardiovascular surgery. METHODS: Consecutive 150 patients over 70 years of age who underwent cardiovascular surgery for valvular, ischemic heart, and aortic diseases were enrolled in this single-center prospective randomized control study from 2010 to 2014. They were assigned to three treatment groups: 1γ group (landiolol at 1 µg/kg/min), 2γ group (landiolol at 2 µg/kg/min), or control group (no landiolol). In the two landiolol groups, landiolol hydrochloride was intravenously administered for a period of 4 days postoperatively. Electrocardiography was continuously monitored during the study period, and cardiologists eventually assessed whether POAF occurred or not. RESULTS: POAF occurred in 24.4% of patients in the control group, 18.2% in 1γ group, and 11.1% in 2γ group (p = 0.256). Multivariate logistic regression analysis showed that the incidence of POAF tended to decrease depending on the dose of landiolol (trend-p = 0.120; 1γ group: OR = 0.786, 95% CI 0.257-2.404; 2γ group: OR = 0.379, 95% CI 0.112-1.287). Subgroup analysis showed a significant dose-dependent reduction in POAF among categories of female sex, non-use of angiotensin II receptor blockers (ARBs) before surgery, and valve surgery (each trend-p = 0.02, 0.03, and 0.004). CONCLUSIONS: These findings indicate that prophylactic administration of low-dose landiolol may not be effective for preventing the occurrence of POAF in overall patients after cardiovascular surgery, but the administration could be beneficial to female patients, patients not using ARBs preoperatively, and those after valvular surgery.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Fibrilação Atrial/prevenção & controle , Procedimentos Cirúrgicos Cardiovasculares , Morfolinas/uso terapêutico , Ureia/análogos & derivados , Antagonistas Adrenérgicos beta/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Relação Dose-Resposta a Droga , Eletrocardiografia , Feminino , Humanos , Infusões Intravenosas , Masculino , Pessoa de Meia-Idade , Morfolinas/administração & dosagem , Complicações Pós-Operatórias/prevenção & controle , Estudos Prospectivos , Resultado do Tratamento , Ureia/administração & dosagem , Ureia/uso terapêutico
6.
Gen Thorac Cardiovasc Surg ; 68(1): 18-23, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31177484

RESUMO

OBJECTIVES: Fibrin glue is used to reinforce anastomosis in aortic surgery. There has not yet been a consensus on how it should be applied optimally. This study aimed to define the optimal condition of applying fibrin glue. METHODS: In experiment 1, we determined the optimal condition for spraying fibrin glue using an expanded polytetrafluoroethylene graft within a needle hole. The length and area of the fibrin cap within the hole were measured. In experiment 2, methods for applying fibrinogen were assessed by comparing brushing and spraying. In experiment 3, swine aorta segments sutured with a Dacron graft were divided into the following three groups: nothing was applied; fibrinogen was sprayed and rubbed using brush. The aorta was clamped and blood was infused from an occlusion catheter inserted into the graft. The pressure at the first appearance of blood leak was recorded. RESULTS: In experiment 1, among the four groups divided by the pressure and distance of spraying, the fibrin cap area in the group with 0.075 MPa and 2-cm spray distance was significantly larger than that in the group with 0.15 MPa and 2 cm (P < 0.01). In experiment 2, the fibrin cap area in the brushing group was significantly larger than that in the spraying group (P < 0.05). In experiment 3, the capacity to resist endoluminal pressure was higher in the brushing and combined spraying group compared with that in the sequential combined spraying group (P < 0.01). CONCLUSIONS: The brush and spray methods showed excellent hemostatic outcomes.


Assuntos
Aorta Torácica/cirurgia , Adesivo Tecidual de Fibrina/farmacologia , Hemostáticos/farmacologia , Administração Tópica , Animais , Prótese Vascular , Cateterismo , Adesivo Tecidual de Fibrina/administração & dosagem , Fibrinogênio/administração & dosagem , Fibrinogênio/farmacologia , Hemostáticos/administração & dosagem , Polietilenotereftalatos , Politetrafluoretileno , Suínos , Trombina/administração & dosagem , Trombina/farmacologia
7.
Gen Thorac Cardiovasc Surg ; 68(3): 240-247, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31372932

RESUMO

OBJECTIVE: Temporary ventricular assist device (VAD) is a commonly used therapeutic option for cardiogenic shock. Patients requiring this treatment are often critical, and clinical outcomes remain unsatisfactory. This study evaluated the feasibility and efficacy of a sternotomy-avoiding technique for temporary VAD implantation to improve patient outcomes. METHODS: Between December 2012 and November 2018, seven patients underwent temporary VAD implantation by sternotomy-avoiding technique (SA group) and eight by median sternotomy technique (MS group). Pre- and intraoperative characteristics, postoperative 7-day hemodynamic parameters, 30-day mortality, and adverse events were compared between the groups. RESULTS: More than 50% of the patients were mechanically supported before temporary VAD implantation. Cardiopulmonary bypass time was significantly shorter in the SA than in the MS group (84 min vs 215 min; p = 0.011); surgical time tended to be shorter in the SA group (385 min vs 461 min; p = 0.064). Pump index, cardiac index, mixed venous oxygen saturation, and central venous pressure did not differ significantly during the first seven days of support. The 30-day incidence of any adverse event was not significantly different between the groups. No patients in the SA group needed re-exploration for surgical bleeding. Thirty-day all-cause mortality rates were 29% in the SA group and 0% in the MS group (p = 0.11). CONCLUSIONS: The sternotomy-avoiding and conventional techniques resulted in comparable short-term hemodynamic support. The sternotomy-avoiding technique was associated with a potential reduction in risk of re-exploration for bleeding. These results support the usefulness of the sternotomy-avoiding procedure for selected patients.


Assuntos
Insuficiência Cardíaca/prevenção & controle , Coração Auxiliar , Hemodinâmica , Implantação de Prótese/métodos , Choque Cardiogênico/terapia , Esternotomia , Adulto , Feminino , Insuficiência Cardíaca/mortalidade , Humanos , Imageamento Tridimensional , Incidência , Masculino , Pessoa de Meia-Idade , Período Pré-Operatório , Estudos Retrospectivos , Resultado do Tratamento
8.
Biomed Mater Eng ; 30(2): 231-241, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30741670

RESUMO

OBJECTIVE: We aimed to develop a novel ultrasound system and examine its feasibility for noninvasively detecting thoracic aortic aneurysm (TAA) in clinical settings. METHODS: We developed a novel ultrasound system consisting of a modified console and data analysis algorithm. The exploratory study included 100 patients hospitalized for elective cardiovascular surgery. After admission, the arterial pulse waveform at the left carotid artery was acquired using the novel system. Based on these data, we inferred the presence of TAA based on arterial viscoelasticity and instability, which are reflected into the time-averaged trajectory of deformation of the blood vessel wall caused by disturbance of blood flow. Meanwhile, all patients underwent computed tomography as preoperative screening to confirm the presence of TAA. The sensitivity and specificity of TAA detection using the novel ultrasound system were calculated. RESULTS: The datasets from 37 patients were not suitable for analysis and were thus discarded. Based on computed tomography findings, 40 patients were categorized into the aneurysm group while 23 were judged not to have and aortic aneurysm. On the other hand, 44 patients were diagnosed as having TAA based on ultrasound findings obtained using the novel system. The overall sensitivity and specificity of the ultrasound system were 0.83 and 0.52, respectively. CONCLUSION: We successfully developed a novel system for noninvasive, ultrasound-based evaluation of the left carotid artery to detect TAA. Although improvements to the probe and diagnostic algorithm are warranted, this device has potential utility for mass screening to detect asymptomatic TAA as part of community-level healthcare programs.


Assuntos
Aneurisma da Aorta Torácica/diagnóstico por imagem , Artérias Carótidas/diagnóstico por imagem , Ultrassonografia Doppler/métodos , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Aorta Torácica/diagnóstico por imagem , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
9.
Kyobu Geka ; 72(2): 104-107, 2019 Feb.
Artigo em Japonês | MEDLINE | ID: mdl-30772874

RESUMO

Extraperitoneal approach is commonly employed for thoracoabdominal aortic repair via Stoney incision. It is supposedly rare to encounter abdominal visceral bleeding during that procedure. However, the spleen may spontaneously adhere to the adjacent peritoneum, which could induce incidental injury to the spleen by its anterior mobilization during extraperitoneal approach. Unless we bare its potential risk in mind, bleeding from the spleen may be overlooked, which results in hemodynamic deterioration. We have experienced 3 cases of splenic injury that necessitated hemostatic maneuvers for bleeding during and just after the thoracoabdominal aortic repair.


Assuntos
Aorta Abdominal/cirurgia , Aorta Torácica/cirurgia , Hemostasia Cirúrgica/métodos , Complicações Intraoperatórias/etiologia , Baço/lesões , Hemorragia/terapia , Humanos , Complicações Intraoperatórias/terapia , Esplenopatias/terapia , Procedimentos Cirúrgicos Vasculares/efeitos adversos
10.
Ann Thorac Surg ; 108(2): e99-e101, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-30742820

RESUMO

Valve-sparing aortic root replacement is one of the effective repairs for aortic regurgitation resulting from progressive dilatation of the aortic root late after surgical correction of conotruncal anomaly. However, feasibility and effectiveness of this procedure are unknown for unrepaired physiology. A 32-year-old man presented with unrepaired tetralogy of Fallot (TOF) and moderate aortic regurgitation with severe left ventricular dysfunction. Valve-sparing aortic root replacement and TOF repair were simultaneously performed. Six months after the surgical procedure, aortic regurgitation remained trivial. Concomitant valve-sparing aortic root replacement with TOF repair can be feasible and effective for unrepaired TOF with aortic regurgitation.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Procedimentos Cirúrgicos Cardíacos/métodos , Implante de Prótese de Valva Cardíaca/métodos , Tetralogia de Fallot/cirurgia , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/etiologia , Ecocardiografia Doppler em Cores , Humanos , Masculino , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico
11.
Gen Thorac Cardiovasc Surg ; 67(1): 180-186, 2019 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30187260

RESUMO

OBJECTIVE: To prevent paraplegia in patients undergoing thoracoabdominal aortic aneurysm repair, the importance of preoperative identification of the Adamkiewicz artery and reconstruction of critical intercostal artery have been advocated. Conversely, significance of collateral network for spinal cord perfusion has been recognized. We invented a new system consisting of a direct monitoring of cerebrospinal fluid temperature (CSFT) and differential selective hypothermic intercostal artery perfusion (D-HIAP). METHODS: After exposing a critical intercostal artery, a 10-mm prosthetic graft was anastomosed in an end to side fashion. A balloon-tipped catheter was inserted into the graft to perfuse with 15 °C blood. Neighboring intercostal arteries were also perfused in the same fashion. Serial monitoring of CSFT was performed. Between January 2011 and January 2015, D-HIAP was employed in 50 patients with Adamkiewicz artery that located within a reconstructed area. RESULTS: Significant CSFT drop was recorded after initiation of D-HIAP in 42 (84%) patients. Of those, 34 (68%) patients showed significantly lowered CSFT with D-HIAP into a single critical intercostal artery. Perfusion into plural intercostal arteries was necessary for CSFT drop in 2 cases (4%), and plural intercostal artery perfusion further enhanced CSFT drop that had been modestly achieved by single intercostal artery perfusion in 6 cases (12%). Eight (16%) patients did not exhibit a significant drop in CSFT even when D-HIAP was employed for the critical and neighboring intercostal arteries. CONCLUSIONS: The detection of a disparity in temperature between the intrathecal space and blood generated by D-HIAP revealed individual variability in CSFT changes, which may imply a complexity in spinal cord perfusion. Intraoperative D-HIAP may help to identify a major blood supply for spinal cord perfusion and underlying collateral network.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Aneurisma da Aorta Torácica/cirurgia , Parada Circulatória Induzida por Hipotermia Profunda , Paraplegia/prevenção & controle , Procedimentos de Cirurgia Plástica , Isquemia do Cordão Espinal/prevenção & controle , Procedimentos Cirúrgicos Vasculares/métodos , Temperatura Corporal , Líquido Cefalorraquidiano/fisiologia , Humanos , Músculos Intercostais/irrigação sanguínea , Perfusão/métodos , Tomografia Computadorizada por Raios X
12.
Gen Thorac Cardiovasc Surg ; 66(9): 523-528, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-29956049

RESUMO

OBJECTIVES: Stentless bioprosthetic valves provide hemodynamic advantages over stented valves as well as excellent durability. However, some primary tissue failures in bioprostheses have been reported. This study was conducted to evaluate the morphometrical and biomechanical properties of the stentless Medtronic Freestyle™ aortic root bioprosthesis, to identify any arising problem areas, and to speculate on a potential solution. METHODS: The three-dimensional heterogeneity of the stentless bioprosthesis wall was investigated using computed tomography. The ascending aorta and the right, left, and non-coronary sinuses of Valsalva were resected and examined by an indentation test to evaluate their biomechanical properties. RESULTS: The non-coronary sinus of Valsalva was significantly thinner than the right sinus of Valsalva (p < 0.01). Young's modulus, calculated as an indicator of elasticity, was significantly greater at the non-coronary sinus of Valsalva (430.7 ± 374.2 kPa) than at either the left (190.6 ± 70.6 kPa, p < 0.01) or right sinuses of Valsalva (240.0 ± 56.5 kPa, p < 0.05). CONCLUSIONS: Based on the morphometrical and biomechanical analyses of the stentless bioprosthesis, we demonstrated that there are differences in wall thickness and elasticity between each sinus of Valsalva. These differences suggest that the non-coronary sinus of Valsalva is the most vulnerable and at greater risk of tissue failure. The exclusion of the non-coronary sinus of Valsalva may be beneficial to mitigate the long-term risks of tissue failure in the stentless bioprosthesis.


Assuntos
Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Bioprótese , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Seio Aórtico/diagnóstico por imagem , Idoso , Aorta , Estenose da Valva Aórtica/cirurgia , Fenômenos Biomecânicos , Módulo de Elasticidade , Feminino , Hemodinâmica , Humanos , Masculino , Desenho de Prótese , Seio Aórtico/fisiopatologia , Stents , Tomografia Computadorizada por Raios X
13.
Gen Thorac Cardiovasc Surg ; 66(6): 334-343, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29626287

RESUMO

OBJECTIVES: Medical therapy for patients with uncomplicated acute type B aortic dissection (ABAD) is essentially accepted for its excellent early outcome; however, long-term outcomes have not been satisfactory due to aorta-related complications. This trial was performed to investigate the efficacy of a statin as an additive that may enhance the effectiveness of conventional medical treatment in patients with ABAD. METHODS: This was a multi-center, prospective, and randomized comparative investigation of patients with uncomplicated ABAD. Fifty patients with ABAD compatible with inclusion criteria were randomly assigned to two groups and then received administration of pitavastatin (group P) or not (group C). We followed up the patients for 1 year from study onset. RESULTS: Two patients demised during the follow-up period (both were in group C). In addition, aorta-related interventions were performed in two patients (entry closure for aortic dissection by endovascular repair in one patient in each group). Aortic arch diameters at 1 year in group P tended to be smaller than in group C (P = 0.17), and the rate of change of the aortic arch diameters from onset to 1 year was significantly lower in group P (P = 0.046). Multivariate analysis identified patency of the false lumen was detected as a risk factor for aortic arch dilatation (P = 0.02), and pitavastatin intake was a negative risk factor (P = 0.03). CONCLUSIONS: Pitavastatin treatment, in addition to the standard antihypertensive therapy, may have a suppressive effect on aortic arch dilatation in patients with ABAD.


Assuntos
Aneurisma da Aorta Torácica/tratamento farmacológico , Dissecção Aórtica/tratamento farmacológico , Quinolinas/farmacologia , Vasodilatação/efeitos dos fármacos , Idoso , Dissecção Aórtica/fisiopatologia , Aneurisma da Aorta Torácica/fisiopatologia , Feminino , Seguimentos , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/farmacologia , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Método Simples-Cego , Fatores de Tempo , Resultado do Tratamento
14.
Ann Thorac Surg ; 105(5): 1316-1321, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29501637

RESUMO

BACKGROUND: Heparin resistance (HR) is often encountered during cardiovascular operations that require cardiopulmonary bypass. Clinical risk factors and the mechanism underlying heparin resistance are yet to be determined. The aim of this study was to elucidate the clinically valid preoperative predictors related to HR. METHODS: The study evaluated 489 patients undergoing cardiovascular operations. Of these, 25 patients presented with HR and received antithrombin III for the initiation of cardiopulmonary bypass with an effective activated coagulation time. The remaining 464 patients, who did not receive antithrombin III, served as controls (NHR). Preoperative patient demographic and laboratory data were analyzed to identify risk factors for HR. RESULTS: The preoperative laboratory data showed platelet count, fibrinogen, D-dimer, creatinine, and C-reactive protein were significantly higher in the HR group than in the NHR group. As expected, the antithrombin III level was significantly lower overall in the HR group (86.0% vs 95.5%, p = 0.009); however, 80% of the patients in the HR group showed normal antithrombin III levels preoperatively. Multivariable logistic regression analysis identified chronic aortic dissection, chronic obstructive pulmonary disease, smoking, and elevated fibrinogen levels as independent predictors for HR. CONCLUSIONS: HR was shown to be associated with preoperative high fibrinogen levels, a smoking habit, and a preoperative diagnosis of chronic, but not acute, aortic dissection, with chronic obstructive pulmonary disease as comorbidity. Administration of antithrombin III resolved HR in all of the affected patients, even when their preoperative antithrombin III level was within the normal limit.


Assuntos
Anticoagulantes/farmacologia , Ponte Cardiopulmonar , Resistência a Medicamentos , Idoso , Dissecção Aórtica/epidemiologia , Antitrombina III/uso terapêutico , Estudos de Casos e Controles , Feminino , Fibrinogênio/metabolismo , Heparina , Humanos , Masculino , Pessoa de Meia-Idade , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Fatores de Risco , Fumar/efeitos adversos
15.
Ann Thorac Cardiovasc Surg ; 24(2): 89-96, 2018 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-29375096

RESUMO

PURPOSE: Selective cerebral perfusion with the open proximal technique for thoracoabdominal aortic repair has not been conclusively validated because of its procedural complexity and unreliability. We report the clinical outcomes, particularly the cerebroneurological complications, of an open proximal procedure using selective cerebral perfusion. METHODS: A retrospective chart review identified 30 patients between 2007 and 2015 who underwent aortic repair through left lateral thoracotomy with selective cerebral perfusion, established through endoluminal brachiocephalic and left carotid artery and retrograde left axillary artery. RESULTS: The mean durations of the open proximal procedure and cerebral ischemia (the duration of the open proximal procedure minus the duration of selective cerebral perfusion) were 110.3 ± 40.1 min and 24.8 ± 13.0 min, respectively. There were two cases (7%) of permanent neurologic dysfunction (PND) but no in-hospital deaths. Multivariate analysis identified the duration of cerebral ischemia as an independent risk factor for neurologic complications including temporary neurologic dysfunction (TND; odds ratio (OR): 1.13; p = 0.007), but no correlation was found between selective cerebral perfusion duration and neurologic complications. CONCLUSION: Despite the relatively long duration of the open proximal procedure, selective cerebral perfusion has a potential to protect against cerebral complications during thoracic aortic repair through a left lateral thoracotomy.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Artéria Axilar/cirurgia , Implante de Prótese Vascular/métodos , Tronco Braquiocefálico/cirurgia , Artéria Carótida Primitiva/cirurgia , Circulação Cerebrovascular , Doenças do Sistema Nervoso/prevenção & controle , Perfusão/métodos , Toracotomia/métodos , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/fisiopatologia , Artéria Axilar/fisiopatologia , Implante de Prótese Vascular/efeitos adversos , Tronco Braquiocefálico/fisiopatologia , Artéria Carótida Primitiva/fisiopatologia , Distribuição de Qui-Quadrado , Intervalo Livre de Doença , Feminino , Humanos , Estimativa de Kaplan-Meier , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Doenças do Sistema Nervoso/diagnóstico , Doenças do Sistema Nervoso/etiologia , Doenças do Sistema Nervoso/fisiopatologia , Razão de Chances , Duração da Cirurgia , Perfusão/efeitos adversos , Fatores de Proteção , Estudos Retrospectivos , Fatores de Risco , Toracotomia/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
16.
Surg Today ; 48(5): 495-501, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29248960

RESUMO

PURPOSE: The Cox maze IV (CMIV) procedure is being used increasingly frequently for surgical ablation of atrial fibrillation (AF). This study aimed to identify the risk factors of the need for postoperative pacemaker implantation (PMI) after CMIV. METHODS: Preoperative, intraoperative, and postoperative data were retrospectively collected from 67 consecutive patients who underwent CMIV at our institution; 7 (10.4%) required PMI (as a treatment of brady AF or sick sinus syndrome). RESULTS: Patients who needed PMI tended to have lower preoperative heart rates than those who did not on a 12-lead electrocardiogram (ECG; 68.7 ± 11.6 vs. 79.1 ± 18.5 bpm, p = 0.07) and a 24-h ECG (94,772 ± 9800 vs. 109,854 ± 19,078 beats/day, p = 0.03). A multivariate analysis identified a low amplitude of the fibrillatory wave on preoperative ECG as a risk factor of PMI necessity after CMIV [odds ratio = 14.7; 95% confidence interval (CI) 1.9-324.7; p = 0.007] and internal use of angiotensin-converting enzyme inhibitors or angiotensin receptor blockers (ACEIs/ARBs) as a negative risk factor (odds ratio = 0.16; 95% CI 0.02-0.99; p = 0.049). CONCLUSIONS: A low amplitude of the fibrillatory wave was identified as a risk factor of PMI necessity, whereas the internal use of ACEIs/ARBs diminished the need for PMI. These factors should be considered before CMIV is performed.


Assuntos
Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Procedimentos Cirúrgicos Cardíacos/métodos , Ablação por Cateter/métodos , Marca-Passo Artificial , Idoso , Feminino , Previsões , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
17.
J Artif Organs ; 21(2): 247-253, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29147809

RESUMO

Actuator-driven pulsed water-jet (ADPJ) dissection is an emerging surgical method for dissecting tissue without heat and mechanical injury to vessels. We elucidated the mechanical properties of the piezo ADPJ and evaluated its usefulness and safety in coronary artery bypass grafting procedures. The relationship between the input voltage (10-100 V) and peak pressure of the pulsed water jet was evaluated. The tissue strengths of swine internal thoracic and coronary arteries and the surrounding tissues were measured to assure tissue-selective dissection. Internal thoracic arteries were harvested by conventional electric cautery and the water jet in four swine, and eight coronary arteries surrounded by myocardium were attempted to be exposed with the water jet. The dissected specimens were histologically evaluated. The peak pressure of the pulsed water jet was positively correlated with the input voltage (R 2 = 0.9984, P < 0.001). The breaking strengths of the target vessels (internal thoracic and coronary arteries) and the surrounding tissues were significantly different (P = 0.002 and P < 0.001, respectively). Histologic examination revealed that internal thoracic arteries were isolated with less heat damage using the pulsed water jet (P = 0.002) compared with electric cautery, and coronary arteries also were dissected without apparent histologic damage. ADPJ has the possibility of assuring tissue selectivity among the internal thoracic and coronary arteries. The results also indicated that the use of ADPJ may enhance safe procedures to harvest grafts during coronary artery bypass grafting.


Assuntos
Ponte de Artéria Coronária/instrumentação , Dissecação/instrumentação , Artéria Torácica Interna/cirurgia , Animais , Suínos , Água
18.
Gen Thorac Cardiovasc Surg ; 65(12): 710-712, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-28243893

RESUMO

Due to donor shortage, patients with refractory heart failure need to be supported on mechanical circulatory support (MCS). Critically, patients undergo several deployments of MCS in stages inevitably requiring blood products transfusion. MCSs per se along with blood products can trigger immune allosensitization. Antibody-mediated rejection (AMR) is associated with significant mortality after heart transplantation. Here, we present the case with high panel-reactive antibody over 95% who developed AMR early after heart transplantation. This life-threatening complication was successfully treated with multi-modal treatment including anti-CD20 antibody, rituximab.


Assuntos
Anticorpos/imunologia , Rejeição de Enxerto/terapia , Insuficiência Cardíaca/cirurgia , Transplante de Coração/efeitos adversos , Coração Auxiliar , Rituximab/uso terapêutico , Ecocardiografia , Feminino , Rejeição de Enxerto/diagnóstico , Rejeição de Enxerto/imunologia , Insuficiência Cardíaca/mortalidade , Humanos , Fatores Imunológicos/uso terapêutico , Pessoa de Meia-Idade
19.
J Thorac Cardiovasc Surg ; 152(5): 1401-1409, 2016 11.
Artigo em Inglês | MEDLINE | ID: mdl-27640950

RESUMO

OBJECTIVE: We evaluated the effect of cerebrospinal fluid oxygenation for the prevention of spinal cord ischemic injury after infrarenal aortic occlusion in a rabbit model. METHODS: Twenty white Japanese rabbits were categorized into the following 4 groups (5 in each): group S (sham), balloon catheter insertion on to the aorta; group C (control), spinal cord ischemic injury by infrarenal abdominal aortic balloon occlusion for 15 minutes; group N (nonoxygenated), spinal cord ischemic injury with cerebrospinal fluid replacement by nonoxygenated artificial cerebrospinal fluid; and group O (oxygenated), spinal cord ischemic injury with cerebrospinal fluid replacement by nanobubble-oxygenated artificial cerebrospinal fluid. The changes in cerebrospinal fluid partial pressure of oxygen during the peri-ischemic period, modified Tarlov score, and histopathology of the spinal cord 48 hours after aortic maneuvers were evaluated. RESULTS: Cerebrospinal fluid partial pressure of oxygen significantly increased in group O compared with group N after cerebrospinal fluid replacement (254.5 ± 54.8 mm Hg vs 136.1 ± 43.5 mm Hg, P = .02). After 15 minutes of spinal cord ischemic injury, cerebrospinal fluid partial pressure of oxygen in group C decreased to 65.8 ± 18.6 mm Hg compared with baseline (148.8 ± 20.6 mm Hg, P < .01), whereas cerebrospinal fluid partial pressure of oxygen in group O was maintained at remarkably high levels after spinal cord ischemic injury (291.9 ± 51.8 mm Hg), which was associated with improved neurologic function, with 20% of spinal cord ischemic injury having a Tarlov score less than 5 compared with 100% of spinal cord ischemic injury in group C. Preservation of anterior horn neurons in groups N and O was confirmed by histopathologic analysis with significant reduction of degenerated neurons compared with group C. CONCLUSIONS: Cerebrospinal fluid oxygenation with artificial cerebrospinal fluid can exert a protective effect against spinal cord ischemic injury in rabbits.


Assuntos
Líquido Cefalorraquidiano/metabolismo , Oxigênio/metabolismo , Isquemia do Cordão Espinal/líquido cefalorraquidiano , Isquemia do Cordão Espinal/prevenção & controle , Animais , Modelos Animais de Doenças , Masculino , Microbolhas , Coelhos
20.
Ann Thorac Surg ; 102(3): e241-e243, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27549554

RESUMO

We report a case of a 35-year-old male who underwent thoracoabdominal aortic repair of a chronic dissecting aortic aneurysm, Crawford extent II. Preoperative computed tomography showed thrombosis of almost all intercostal arteries. Precise diagnostic assessment demonstrated the Adamkiewicz artery originating from the left lateral thoracic artery and subscapular artery, which would have been at risk after using a standard Stoney's incision, thus potentially causing paraplegia or paraparesis due to spinal cord ischemia. We modified the lateral thoracic incision anteriorly and successfully preserved the collateral arteries without impairing the spinal cord function.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Dissecção Aórtica/cirurgia , Complicações Intraoperatórias/prevenção & controle , Artérias Torácicas/anormalidades , Malformações Vasculares/diagnóstico por imagem , Procedimentos Cirúrgicos Vasculares/métodos , Adulto , Dissecção Aórtica/diagnóstico por imagem , Aneurisma da Aorta Torácica/diagnóstico por imagem , Doença Crônica , Angiografia por Tomografia Computadorizada/métodos , Seguimentos , Humanos , Masculino , Cuidados Pré-Operatórios/métodos , Medição de Risco , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA