Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
Foods ; 13(13)2024 Jul 03.
Artigo em Inglês | MEDLINE | ID: mdl-38998630

RESUMO

Amino acids are significant biomolecules that govern the major metabolic processes and act as precursors for macromolecules such as proteins that are crucial to life. Fish is an integral component of human nutrition and a dietary source of high-quality animal proteins and amino acids. In this context, the crude protein and amino acid compositions of food fish from different landing stations of the Ganga river have been determined. The Kjeldahl method was utilized to determine the crude protein content and the amino acids were analyzed using high-performance liquid chromatography (HPLC); data on 30 food fish were assessed. The study showed that among the fish studied, Eleotris fusca, Macrobrachium malcomsonii, and Mystus cavasius were rich in most of the amino acids important for human nutrition, such as glycine, glutamic acid, cysteine, threonine, phenylalanine, methionine, lysine, leucine, isoleucine, histidine, and valine. Further, it was observed that the daily consumption of these fish (approximately 50 g) can fulfil the daily requirement of these individual amino acids for an adult human with a body weight of 60 kg. Therefore, the amino acid composition analyzed in the present study could be utilized for recommendation by clinicians according to the requirement for specific amino acids, and fish can be prescribed as a natural supplement against the amino acid requirement.

2.
Future Cardiol ; : 1-6, 2024 Jul 15.
Artigo em Inglês | MEDLINE | ID: mdl-39007846

RESUMO

Background: This retrospective cohort study aimed to compare the outcomes of graft angiography using these two approaches. Methods: Medical records and angiographic data of adult patients who underwent graft angiography between January 2020 and December 2022 were analyzed. Results: The study included 452 patients in the distal radial access (DRA) group and 960 patients in the femoral access group. Angiographic characteristics showed a higher prevalence of triple vessel disease in the femoral access group (29.8% vs. 20.8%; p = 0.012). The DRA group had a procedural success rate of 93.0%, while the femoral access group had a higher success rate of 95.8%. The odds ratio was 0.66 (95% CI: 0.46-0.94), indicating lower odds of procedural success in the DRA group. Conclusion: Our study suggests that both DRA and femoral access are effective and safe approaches for graft angiography after coronary artery bypass surgery.


This study compared graft angiography outcomes using wrist (distal radial) and groin (femoral) access in patients after coronary artery bypass surgery. Analyzing data from January 2020 to December 2022, 452 patients used wrist access, and 960 used groin access, with similar age and heart function across groups. Femoral access had more cases of triple vessel disease (29.8% vs. 20.8%) and a higher success rate (95.8% vs. 93.0%), with wrist access showing lower odds of procedural success. Despite this, both methods proved to be effective and safe.

3.
Crit Pathw Cardiol ; 23(2): 73-80, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38446086

RESUMO

OBJECTIVE: To find out whether inclisiran sodium has different efficacy in heterozygous familial hypercholesterolemia (HeFH) and homozygous familial hypercholesterolemia (HoFH) patient groups. METHODS: We conducted the systematic review and meta-analysis of ORION clinical trials. PubMed, Embase, and Clinicaltrials.gov databases were searched for the relevant studies. Atheroscalerotic parameters considered for our objective were low-density lipoprotein cholesterol, total cholesterol, proprotein convertase subtilisin/kexin type 9 (PCSK9), apolipoprotein B, and nonhigh-density lipoprotein cholesterol. Primary outcomes were the percentage difference in atheroscalerotic parameters at follow-up relative to baseline values. Our study examined these primary outcomes to determine whether there is a statistically significant difference between the HeFH and HoFH groups. Risk of bias was assessed by the Cochrane risk of bias tool. Meta-analysis was performed when at least 2 studies reported on the same variable. RESULTS: Four ORION clinical trials provided the data related to the mean difference in the atheroscalerotic parameters at follow-up relative to baseline, of HeFH and HoFH patient populations, after administration of 300 mg inclisiran subcutaneously. We pooled together these mean differences for each group and applied a statistical test to analyze if the values were significantly different between the groups. The results of our study unveiled the significant difference in pooled mean differences in low-density lipoprotein cholesterol (HeFH: -48.62%; HoFH: -9.12%; P < 0.05), total cholesterol (HeFH: -30.31%; HoFH: -11.50%; P < 0.05), apolipoprotein (HeFH: -39.97%; HoFH: -14.68%; P < 0.05), and nonhigh-density lipoprotein (HeFH: -44.51%; HoFH: -12.22%; P < 0.05) between HeFH and HoFH groups. However, the difference in pooled mean difference in PCSK9 values (HeFH: -68.41%; HoFH: -56.25%; P = 0.2) between HeFH and HoFH groups was statistically insignificant. Studies were of high quality. CONCLUSIONS: There was a significant difference in the reductions in atherosclerotic lipid parameters in heterozygous and homozygous populations after the administration of inclisiran except for PCSK9 parameter. Further studies are needed to support this conclusion.


Assuntos
Heterozigoto , Homozigoto , Hiperlipoproteinemia Tipo II , Humanos , Hiperlipoproteinemia Tipo II/genética , Hiperlipoproteinemia Tipo II/sangue , LDL-Colesterol/sangue , Resultado do Tratamento , Anticolesterolemiantes/uso terapêutico , RNA Interferente Pequeno
4.
J Funct Biomater ; 14(9)2023 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-37754862

RESUMO

With their distinctive core-shell design, core-shell nanocrystals have drawn interest in catalysis, medicinal research, and nanotechnology. These nanocrystals have a variety of characteristics and possible uses. The application of core-shell nanocrystals offers significant potential in increasing diagnostic and therapeutic approaches for cancer research in apoptosis and in vitro cancer cell imaging. In the present study, we investigated the fluorescence behavior of hydrophilic CdSe (core-only) and CdSe@CdS (core-shell) nanocrystals (NCs) and their potential in cancer cell imaging. The addition of a CdS coating to CdSe NCs increased the fluorescence intensity tenfold. The successful fabrication of core-shell CdSe@CdS nanocrystals was proven by a larger particle size (evaluated via DLS and TEM) and their XRD pattern and surface morphology compared to CdSe (core-only) NCs. When these NCs were used for bioimaging in MCF-7 and HEK-293 cell lines, they demonstrated excellent cellular uptake due to higher fluorescence intensity within cancerous cells than normal cells. Comparative cytotoxicity studies revealed that CdSe NCs were more toxic to all three cell lines (HEK-293, MCF-7, and HeLa) than CdSe@CdS core-shell structures. Furthermore, a decrease in mitochondrial membrane potential and intracellular ROS production supported NCs inducing oxidative stress, which led to apoptosis via the mitochondria-mediated pathway. Increased cytochrome c levels, regulation of pro-apoptotic gene expression (e.g., p53, Bax), and down-regulation of Bcl-2 all suggested cellular apoptosis occurred via the intrinsic pathway. Significantly, at an equivalent dose of core-shell NCs, core-only NCs induced more oxidative stress, resulting in increased apoptosis. These findings shed light on the role of a CdS surface coating in reducing free radical release, decreasing cytotoxicity, and improving fluorescence, advancing the field of cell imaging.

5.
Z Med Phys ; 2023 Aug 14.
Artigo em Inglês | MEDLINE | ID: mdl-37586961

RESUMO

Three types of gamma radiation detectors associated with distributed electronics namely, NaI (Tl), HPGe and LaBr3(Ce) are compared primarily focusing on electronic noise and scattering noise. Additionally, detectors of same make, material, size and electronics are also compared. A methodology is proposed to select the most suitable detector for computed tomography (CT) among the available options. Standard deviation parameter is employed to estimate electronic noise without performing CT experiment. Kanpur theorem-1(KT-1) is used to estimate the scattering noise quantitatively after verifying its sensitivity to scattering noise. The impact of scattering noise on CT profiles is evaluated using dice similarity dice coefficient. A good resemblance between KT-1 and dice coefficient is observed. A maximum difference of 56% in scattering noise is observed when five detectors used simultaneously instead of single detector whereas a discrepancy of 85% is observed between different types of radiation detectors. As far as ease of handling, operational and capital cost is concern one has to compromise minimum 12% of accuracy in CT reconstruction if NaI (Tl) detector is used with respect to best alternative available. The proposed methodology can be applied to measurement that require minimal scattering interference data other than CT experiments. The manufacturer can add noise level of detector as a characteristic parameter in the data sheet.

6.
Curr Drug Metab ; 23(9): 678-692, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35692131

RESUMO

Liposomes nowadays have become a preferential drug delivery system since they provide facilitating properties to drugs, such as improved therapeutic index of encapsulated drug, target and controlled drug delivery, and less toxicity. However, conventional liposomes have shown some disadvantages, such as less drug loading capacity, poor retention, clearance by kidney or reticuloendothelial system, and less release of hydrophilic drugs. Thus, to overcome these disadvantages recently, scientists have explored new approaches and methods, viz., ligand conjugation, polymer coating, and liposome hybrids, including surface-modified liposomes, biopolymer-incorporated liposomes, guest-in-cyclodextrin-in-liposome, liposome-in-hydrogel, liposome-in-film, liposome-in-nanofiber, etc. These approaches have been shown to improve the physiochemical and pharmacokinetic properties of encapsulated drugs. Lately, pharmacokinetic-pharmacodynamic (PK-PD) computational modeling has emerged as a beneficial tool for analyzing the impact of formulation and system-specific factors on the target disposition and therapeutic efficacy of liposomal drugs. There has been an increasing number of liposome-based therapeutic drugs, both FDA approved and those undergoing clinical trials, having application in cancer, Alzheimer's, diabetes, and glaucoma. To meet the continuous demand of health sectors and to produce the desired product, it is important to perform pharmacokinetic studies. This review focuses on the physical, physicochemical, and chemical factors of drugs that influence the target delivery of drugs. It also explains various physiological barriers, such as systemic clearance and extravasation. A novel approach, liposomal-hybrid complex, an innovative approach as a vesicular drug delivery system to overcome limited membrane permeability and bioavailability, has been discussed in the review. Moreover, this review highlights the pharmacokinetic considerations and challenges of poorly absorbed drugs along with the applications of a liposomal delivery system in improving PKPD in various diseases, such as cancer, Alzheimer's, diabetes, and glaucoma.


Assuntos
Doença de Alzheimer , Diabetes Mellitus , Glaucoma , Neoplasias , Humanos , Lipossomos , Sistemas de Liberação de Medicamentos
7.
PLoS One ; 12(12): e0188880, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29206232

RESUMO

Human exposure to intermediate frequency magnetic fields (MF) is increasing due to applications like electronic article surveillance systems and induction heating cooking hobs. However, limited data is available on their possible health effects. The present study assessed behavioral and histopathological consequences of exposing mice to 7.5 kHz MF at 12 or 120 µT for 5 weeks. No effects were observed on body weight, spontaneous activity, motor coordination, level of anxiety or aggression. In the Morris swim task, mice in the 120 µT group showed less steep learning curve than the other groups, but did not differ from controls in their search bias in the probe test. The passive avoidance task indicated a clear impairment of memory over 48 h in the 120 µT group. No effects on astroglial activation or neurogenesis were observed in the hippocampus. The mRNA expression of brain-derived neurotrophic factor did not change but expression of the proinflammatory cytokine tumor necrosis factor alpha mRNA was significantly increased in the 120 µT group. These findings suggest that 7.5 kHz MF exposure may lead to mild learning and memory impairment, possibly through an inflammatory reaction in the hippocampus.


Assuntos
Comportamento Animal , Campos Magnéticos , Transtornos da Memória/etiologia , Animais , Aprendizagem da Esquiva , Peso Corporal , Fator Neurotrófico Derivado do Encéfalo/genética , Camundongos , RNA Mensageiro/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA