Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
World J Pediatr Congenit Heart Surg ; 13(3): 304-309, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35446224

RESUMO

OBJECTIVES: During congenital heart surgery, the pulmonary valve and root may be placed into the systemic position, yielding a "neoaortic" valve. With the stress of systemic pressure, the pulmonary roots can dilate, creating aneurysms and/or neoaortic insufficiency (neoAI). This report analyzes the early outcomes of patients undergoing neoaortic valve repair incorporating geometric ring annuloplasty. METHODS: Twenty-one patients underwent intended repair at six centers and formed the study cohort. Thirteen had previous Ross procedures, five had arterial switch operations, and three Fontan physiology. Average age was 21.7 ± 12.8 years (mean ± SD), 80% were male, and 11 (55%) had symptomatic heart failure. Preoperative neoAI Grade was 3.1 ± 1.1, and annular diameter was 30.7 ± 6.5 mm. RESULTS: Valve repair was accomplished in 20/21, using geometric annuloplasty rings and leaflet plication (n = 13) and/or nodular release (n = 7). Fourteen had neoaortic aneurysm replacement (13 with root remodeling). Two underwent bicuspid valve repair. Six had pulmonary conduit changes, one insertion of an artificial Nodulus Arantius, and one resection of a subaortic membrane. Ring size averaged 21.9 ± 2.3 mm, and aortic clamp time was 171 ± 54 minutes. No operative mortality or major morbidity occurred, and postoperative hospitalization was 4.3 ± 1.4 days. At discharge, neoAI grade was 0.2 ± 0.4 (P < .0001), and valve mean gradient was ≤20 mm Hg. At average 18.0 ± 9.1 months of follow-up, all patients were asymptomatic with stable valve function. CONCLUSIONS: Neoaortic aneurysms and neoAI are occasionally seen late following Ross, arterial switch, or Fontan procedures. Neoaortic valve repair using geometric ring annuloplasty, leaflet reconstruction, and root remodeling provides a patient-specific approach with favorable early outcomes.


Assuntos
Insuficiência da Valva Aórtica , Anuloplastia da Valva Cardíaca , Adolescente , Adulto , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Anuloplastia da Valva Cardíaca/efeitos adversos , Anuloplastia da Valva Cardíaca/métodos , Criança , Feminino , Humanos , Masculino , Valva Mitral , Resultado do Tratamento , Adulto Jovem
2.
Ann Thorac Surg ; 111(4): 1359-1366, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-32619617

RESUMO

BACKGROUND: Unicuspid aortic valves (Sievers type 2 bicuspid) are characterized by major fusion and clefting of the right-left coronary commissure, and minor fusion of the right-noncoronary commissure. Repair has been difficult because of two fusions, variable relative sinus sizes, and peripheral leaflet deficiencies or tears after balloon valvuloplasty. METHODS: Twenty unicuspid aortic valves patients underwent valve repair in nine institutions. Right-left major fusion and right-noncoronary minor fusion occurred in 17 of 20 (85%). Commissurotomy was performed on the minor fusion, and a bicuspid annuloplasty ring with circular base geometry and two 180-degree subcommissural posts was sutured beneath the annulus, equalizing the annular circumferences of the fused and nonfused cusps. The nonfused leaflet was plicated, and the cleft in the major fusion was closed linearly until leaflet effective heights and lengths became greater than 8 mm and equal, respectively. RESULTS: Average age (mean ± SD) was 22.3 ± 12.3 years (range, 13 to 58), 12 of 20 (60%) were symptomatic, 10 of 20 (50%) required aortic aneurysm resection. Pre-repair hemodynamic data included mean systolic valve gradient 25.8 ± 12.9 mm Hg, aortic insufficiency grade 2.9 ± 1.2, and annular diameter 24.7 ± 3.3 mm. No mortality or major complications occurred. Post-repair annular (ring) size was 20.5 ± 1.3 mm, mean gradient fell to 16.2 ± 5.9 mm Hg, and aortic insufficiency grade decreased to 0.1 ± 0.3 (P < .001). At an average follow-up of 11 months (range, 1 to 22), all 20 patients were asymptomatic and had returned to full activity. CONCLUSIONS: Aortic ring annuloplasty reduced annular diameter effectively, recruiting more leaflet to midline coaptation. Minor fusion commissurotomy and annular remodeling to 180-degree commissures converted UAV repair to a simple and reproducible procedure.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Adolescente , Adulto , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/diagnóstico , Anuloplastia da Valva Cardíaca/métodos , Criança , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA