Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
J Am Coll Radiol ; 20(2): 207-214, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36496088

RESUMO

OBJECTIVES: The aim of this study was to compare screening mammography performance metrics for immediate (live) interpretation versus offline interpretation at a cancer center. METHODS: An institutional review board-approved, retrospective comparison of screening mammography metrics at a cancer center for January 1, 2018, to December 31, 2019 (live period), and September 1, 2020, to March 31, 2022 (offline period), was performed. Before July 2020, screening examinations were interpreted while patients waited (live period), and diagnostic workup was performed concurrently. After the coronavirus disease 2019 shutdown from March to mid-June 2020, offline same-day interpretation was instituted. Patients with abnormal screening results returned for separate diagnostic evaluation. Screening metrics of positive predictive value 1 (PPV1), cancer detection rate (CDR), and abnormal interpretation rate (AIR) were compared for 17 radiologists who interpreted during both periods. Statistical significance was assessed using χ2 analysis. RESULTS: In the live period, there were 7,105 screenings, 635 recalls, and 51 screen-detected cancers. In the offline period, there were 7,512 screenings, 586 recalls, and 47 screen-detected cancers. Comparison of live screening metrics versus offline metrics produced the following results: AIR, 8.9% (635 of 7,105) versus 7.8% (586 of 7,512) (P = .01); PPV1, 8.0% (51 of 635) versus 8.0% (47 of 586); and CDR, 7.2/1,000 versus 6.3/1,000 (P = .50). When grouped by >10% AIR or <10% AIR for the live period, the >10% AIR group showed a significant decrease in AIR for offline interpretation (from 12.7% to 9.7%, P < .001), whereas the <10% AIR group showed no significant change (from 7.4% to 6.7%, P = .17). CONCLUSIONS: Conversion to offline screening interpretation from immediate interpretation at a cancer center was associated with lower AIR and similar CDR and PPV1. This effect was seen largely in radiologists with AIR > 10% in the live setting.


Assuntos
Neoplasias da Mama , COVID-19 , Humanos , Feminino , Estudos Retrospectivos , Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento
2.
J Breast Imaging ; 4(6): 618-624, 2022 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-38416996

RESUMO

OBJECTIVE: To determine the minimum number of stereotactic biopsy specimens containing calcifications sufficient for pathologic diagnosis and the minimum number of specimens containing calcifications sufficient for immunohistochemistry (IHC) in cases of malignancy. METHODS: In this IRB-exempt quality assurance initiative, individual specimens from 126 patients with 129 calcified targets retrieved using a stereotactic system with real time specimen imaging were prospectively analyzed. Pathology was reported independently for each specimen containing calcifications. In every case, the pathologist reported which specimen containing calcifications was sufficient for diagnosis and, in cases of malignancy, which calcified specimen was sufficient for diagnosis and IHC. RESULTS: A diagnosis was made from the first calcified specimen in 74% of cases (95/129), from the first two calcified specimens in 92% (119/129) of cases, and from the first three calcified specimens in 100% of cases. Pathology was benign in 66% (85/129) of cases, with the diagnosis made from the first calcified specimen in 78% (66/85) of cases. High-risk lesions were the primary pathology in 8% (11/129) of cases, with 55% (6/11) diagnosed from the first calcified specimen. Pathology was malignant in 26% (33/129) of cases. The first calcified specimen was sufficient for diagnosis and IHC in 73% (24/33) of malignancies and the first three calcified specimens were sufficient for diagnosis and IHC in all cases of malignancy. CONCLUSION: Three cores verified to contain calcifications on real time specimen imaging were sufficient to make a diagnosis in all cases and to make a diagnosis and obtain IHC in nearly all cases of malignancy.


Assuntos
Calcinose , Neoplasias , Humanos , Mama/patologia , Mamografia , Calcinose/diagnóstico por imagem , Biópsia com Agulha de Grande Calibre , Neoplasias/diagnóstico
3.
Breast Cancer Res Treat ; 184(1): 185-192, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32770455

RESUMO

PURPOSE: To compare ultrasound visibility of selected biopsy markers in animal tissue models simulating axillary echotexture. METHODS: Four breast biopsy markers were selected based on size, shape, and composition and compared to an institutional standard for testing in beef steak and pork loin phantoms. BD® UltraCor™ Twirl™; Hologic® Tumark® Professional series Q, Vision, and X; and BD® UltraClip™ Dual Trigger wing-shaped (institutional standard) biopsy markers were deployed at superficial (0-2.0 cm) and deep (2.1-4.0 cm) depths in the animal models. An animal model without a biopsy marker served as control. Four participating breast imagers blinded to marker shape and location assessed ultrasound visibility of each biopsy marker using a handheld 5-12 MHz linear array transducer with a 4-point grading system (0, not visible; 1, unsure if visible; 2, visible with difficulty; 3, definite visibility). Each breast imager was asked to select the three most easily visualized biopsy markers. RESULTS: Total visibility scores with the four-point grading system demonstrate highest score for the Twirl™ (48/48 points), followed by the Tumark® Q (42/48) and Tumark® Vision (41/48) biopsy markers. Overall individual accuracy scores across all biopsy marker types ranged from 83.3 to 95.8%. Visibility scores based on subjective radiologist assessment also demonstrate the highest vote for the Twirl™ (11), followed by the Tumark® Vision (7) and Tumark® Q (6) biopsy markers. The wing-shaped biopsy marker had the lowest visibility and voter score. CONCLUSION: The Twirl™ followed by the Tumark® Q and Vision biopsy markers demonstrates the highest visibility scores using a four-point grading system and by radiologist vote.


Assuntos
Neoplasias da Mama , Terapia Neoadjuvante , Animais , Axila , Biópsia , Neoplasias da Mama/diagnóstico por imagem , Bovinos , Feminino , Humanos , Linfonodos , Modelos Animais , Biópsia de Linfonodo Sentinela , Ultrassonografia
4.
J Clin Oncol ; 38(16): 1849-1863, 2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-32058842

RESUMO

PURPOSE: To develop recommendations concerning the management of male breast cancer. METHODS: ASCO convened an Expert Panel to develop recommendations based on a systematic review and a formal consensus process. RESULTS: Twenty-six descriptive reports or observational studies met eligibility criteria and formed the evidentiary basis for the recommendations. RECOMMENDATIONS: Many of the management approaches used for men with breast cancer are like those used for women. Men with hormone receptor-positive breast cancer who are candidates for adjuvant endocrine therapy should be offered tamoxifen for an initial duration of five years; those with a contraindication to tamoxifen may be offered a gonadotropin-releasing hormone agonist/antagonist plus aromatase inhibitor. Men who have completed five years of tamoxifen, have tolerated therapy, and still have a high risk of recurrence may be offered an additional five years of therapy. Men with early-stage disease should not be treated with bone-modifying agents to prevent recurrence, but could still receive these agents to prevent or treat osteoporosis. Men with advanced or metastatic disease should be offered endocrine therapy as first-line therapy, except in cases of visceral crisis or rapidly progressive disease. Targeted systemic therapy may be used to treat advanced or metastatic cancer using the same indications and combinations offered to women. Ipsilateral annual mammogram should be offered to men with a history of breast cancer treated with lumpectomy regardless of genetic predisposition; contralateral annual mammogram may be offered to men with a history of breast cancer and a genetic predisposing mutation. Breast magnetic resonance imaging is not recommended routinely. Genetic counseling and germline genetic testing of cancer predisposition genes should be offered to all men with breast cancer.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias da Mama Masculina/terapia , Medicina Baseada em Evidências/normas , Mastectomia/normas , Oncologia/normas , Protocolos de Quimioterapia Combinada Antineoplásica/efeitos adversos , Neoplasias da Mama Masculina/diagnóstico , Neoplasias da Mama Masculina/genética , Quimioterapia Adjuvante , Consenso , Técnica Delphi , Aconselhamento Genético/normas , Testes Genéticos/normas , Humanos , Imageamento por Ressonância Magnética/normas , Masculino , Mamografia/normas , Mastectomia/efeitos adversos , Valor Preditivo dos Testes , Resultado do Tratamento
5.
Int J Cardiovasc Imaging ; 22(1): 111-8, 2006 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-16374527

RESUMO

OBJECTIVES: We compared the accuracy and reliability of prospectively triggered, retrospectively ECG gated, and non-gated CT image reconstruction for measurements of coronary artery calcification (CAC) in vivo using a novel animal model. MATERIALS AND METHODS: In six Yorkshire farm pigs, prefabricated chains of cortical bone fragments were sutured over the epicardial bed of the major coronary arteries. Using a 4-slice MDCT scanner, each animal was imaged with two different protocols: sequential acquisition with prospective ECG triggering, and spiral acquisition with retrospectively ECG gated image reconstruction- non-gated reconstructions were also generated from these latter scans. Two independent observers measured the 'Agatston score' (AS), the calcified volume (CV), and mineral mass (MM). To calculate accuracy of MM measurements the ash weight of the burned bone fragments was compared to MDCT derived MM. RESULTS: Six pigs successfully underwent surgery and CT imaging (mean heart rate: 86+/-12 bpm). MM measurements from prospectively ECG triggered CT sequential scans were more accurate (p<0.02) and reproducible (p=0.05) than sequential CT scans without ECG triggering or spiral acquisition using retrospective ECG gating. CONCLUSIONS: At high heart rates prospective ECG triggered image reconstruction is more accurate and reproducible for CAC scoring than retrospective ECG gated reconstruction and non-gated reconstruction.


Assuntos
Calcinose/diagnóstico por imagem , Doença das Coronárias/diagnóstico por imagem , Processamento de Imagem Assistida por Computador , Tomografia Computadorizada Espiral/métodos , Análise de Variância , Animais , Eletrocardiografia , Estudos de Viabilidade , Reprodutibilidade dos Testes , Suínos
6.
Radiology ; 229(2): 375-81, 2003 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-14526093

RESUMO

PURPOSE: To test the accuracy and precision of multi-detector row computed tomography (CT)-derived measurements of vascular calcification in ex vivo human carotid endarterectomy (CEA) specimens. MATERIALS AND METHODS: Sixteen ex vivo CEA specimens were imaged with multi-detector row CT. Multi-detector row CT-derived calcium scoring algorithms (ie, mineral mass and volume score) were compared with the mass and volume of ashed remnants of the CEA specimens. Bland-Altman analysis was performed to assess the mean (ie, bias) and SD (ie, precision) of differences between multi-detector row CT- and ashing-derived measurements. In addition, conventional Agatston score, volume score, mineral mass, and modified Agatston score were calculated for each specimen by using a number of scanning protocols. Images were obtained at a section thickness of 1.25 mm by using different tube energy settings and tube currents. Specimens were also imaged at different section thicknesses with fixed combinations of tube energy and tube current. To compare measurement variability of scoring methods, coefficients of variation for all protocols were calculated. RESULTS: Both mean multi-detector row CT-derived mineral mass and mean ashing-derived mineral mass were 0.129 g +/- 0.173 (r = 0.99, P <.001). Mean multi-detector row CT- and ashing-derived volumes were 339.94 mm3 +/- 395.4 and 39.48 mm3 +/- 55.76, respectively (r = 0.95, P <.001). Measurement bias relative to the reference ashing values was high (2,800.0%) for volume score and low (2.58%) for mineral mass. Measurement precision was 0.6% for volume score and greater than 0.0005% for mineral mass. Mean coefficients of variation for all CT protocols were 5.0% +/- 4.2 and 4.9% +/- 4.2 for mineral mass and modified Agatston score, respectively, and 16.0% +/- 9.2 and 14.5% +/- 3.9 for conventional Agatston and volume scores, respectively (P <.001). CONCLUSION: Compared with the conventional volume score, multi-detector row CT-derived mineral mass is a less biased and more precise measurement of the mineral content of nonmoving ex vivo CEA specimens. Mineral mass and modified Agatston score are more reproducible than conventional volume and Agatston scores.


Assuntos
Calcinose/diagnóstico por imagem , Artéria Carótida Interna/diagnóstico por imagem , Estenose das Carótidas/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas , Feminino , Humanos , Técnicas In Vitro , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA