Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Steroid Biochem Mol Biol ; 190: 115-125, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-30940596

RESUMO

Serum concentrations of lathosterol, the plant sterols campesterol and sitosterol and the cholesterol metabolite 5α-cholestanol are widely used as surrogate markers of cholesterol synthesis and absorption, respectively. Increasing numbers of laboratories utilize a broad spectrum of well-established and recently developed methods for the determination of cholesterol and non-cholesterol sterols (NCS). In order to evaluate the quality of these measurements and to identify possible sources of analytical errors our group initiated the first international survey for cholesterol and NCS. The cholesterol and NCS survey was structured as a two-part survey which took place in the years 2013 and 2014. The first survey part was designed as descriptive, providing information about the variation of reported results from different laboratories. A set of two lyophilized pooled sera (A and B) was sent to twenty laboratories specialized in chromatographic lipid analysis. The different sterols were quantified either by gas chromatography-flame ionization detection, gas chromatography- or liquid chromatography-mass selective detection. The participants were requested to determine cholesterol and NCS concentrations in the provided samples as part of their normal laboratory routine. The second part was designed as interventional survey. Twenty-two laboratories agreed to participate and received again two different lyophilized pooled sera (C and D). In contrast to the first international survey, each participant received standard stock solutions with defined concentrations of cholesterol and NCS. The participants were requested to use diluted calibration solutions from the provided standard stock solutions for quantification of cholesterol and NCS. In both surveys, each laboratory used its own internal standard (5α-cholestane, epicoprostanol or deuterium labelled sterols). Main outcome of the survey was, that unacceptably high interlaboratory variations for cholesterol and NCS concentrations are reported, even when the individual laboratories used the same calibration material. We discuss different sources of errors and recommend all laboratories analysing cholesterol and NCS to participate in regular quality control programs.


Assuntos
Colesterol/sangue , Fitosteróis/sangue , Colestanol/sangue , Colesterol/análogos & derivados , Cromatografia Gasosa/métodos , Cromatografia Líquida/métodos , Humanos , Sitosteroides/sangue , Inquéritos e Questionários
2.
Biochimie ; 153: 26-32, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30063945

RESUMO

Increasing numbers of laboratories develop new methods based on gas-liquid and high-performance liquid chromatography to determine serum concentrations of oxygenated cholesterol metabolites such as 7α-, 24(S)-, and 27-hydroxycholesterol. We initiated a first international descriptive oxycholesterol (OCS) survey in 2013 and a second interventional survey 2014 in order to compare levels of OCS reported by different laboratories and to define possible sources of analytical errors. In 2013 a set of two lyophilized serum pools (A and B) was sent to nine laboratories in different countries for OCS measurement utilizing their own standard stock solutions. In 2014 eleven laboratories were requested to determine OCS concentrations in lyophilized pooled sera (C and D) utilizing the same provided standard stock solutions of OCS. The participating laboratories submitted results obtained after capillary gas-liquid chromatography-mass selective detection with either epicoprostanol or deuterium labelled sterols as internal standards and high-performance liquid chromatography with mass selective detection and deuterated OCS as internal standard. Each participant received a clear overview of the results in form of Youden-Plots and basic statistical evaluation in its used unit. The coefficients of variation of the concentrations obtained by all laboratories using their individual methods were 58.5-73.3% (survey 1), 56.8-60.3% (survey 2); 36.2-35.8% (survey 1), 56.6-59.8, (survey 2); 61.1-197.7% (survey 1), 47.2-74.2% (survey 2) for 24(S)-, 27-, and 7α-hydroxycholesterol, respectively. We are surprised by the very great differences between the laboratories, even under conditions when the same standards were used. The values of OCS's must be evaluated in relation to the analytical technique used, the efficiency of the ample separation and the nature of the internal standard used. Quantification of the calibration solution and inappropriate internal standards could be identified as major causes for the high variance in the reported results from the different laboratories. A harmonisation of analytical standard methods is highly needed.


Assuntos
Colesterol/análise , Cromatografia Gasosa/métodos , Cromatografia Líquida/métodos , Colesterol/normas , Humanos , Padrões de Referência , Inquéritos e Questionários
3.
Int J Food Sci Nutr ; 68(6): 695-703, 2017 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-28276904

RESUMO

Sterols are components present in the fat fraction of infant formulas (IFs). Their characterization is therefore of interest, though there are no official reference methods for their analysis in these matrices. AIM: To validate a gas chromatographic method with flame ionization detection for the determination of animal (cholesterol and desmosterol) and plant sterols (brassicasterol, campesterol, stigmasterol, ß-sitosterol and sitostanol) found in IFs. All correlation coefficients obtained for the calibration curves of sterols studied were >0.99. Limits of detection (<1 µg/100 mL) and quantification (<4 µg/100 mL) are suitable for sterols determination in IFs. The within-assay precision ranged from 1.6% to 8.8%, while the between-assay precision was <10% for most of sterols. Accuracy was satisfactory and was calculated by recovery assays (ranging 93-108%). The analytical parameters obtained showed the suitability of the proposed method for the determination of sterols in IFs.


Assuntos
Cromatografia Gasosa , Fórmulas Infantis/química , Fitosteróis/análise , Calibragem , Colestadienóis/análise , Colesterol/análogos & derivados , Colesterol/análise , Desmosterol/análise , Ionização de Chama , Limite de Detecção , Reprodutibilidade dos Testes , Sitosteroides/análise , Estigmasterol/análise
4.
J Agric Food Chem ; 60(18): 4725-34, 2012 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-22509888

RESUMO

Plant sterols (PS) stability, antioxidant parameters, and color were studied during 6 months of storage at 4, 24, and 37 °C in three PS-enriched functional beverages. Beverages were skimmed milk with fruit juice and PS (MFJPS), fruit juice and PS (FJPS), and skimmed milk with PS (MPS). No loss in total PS content occurred during storage observing the same values at any given storage time point. Total carotenoids decreased 36% with storage at two months and then remained stable. Total polyphenols showed fluctuations throughout the storage, remaining stable at 6 months and reaching initial values. The antioxidant capacity (TEAC method) increased 18% at 6 months, and there was an increase in color over time and temperature, probably due to Maillard reaction compound formation. The increase in total antioxidant capacity might have helped PS maintenance throughout storage, these beverages being a good PS source even after 6 months of storage.


Assuntos
Antioxidantes/análise , Bebidas/análise , Armazenamento de Alimentos , Alimentos Fortificados/análise , Fitosteróis/análise , Antioxidantes/química , Laticínios/análise , Frutas/química , Fitosteróis/química , Espanha
5.
J Agric Food Chem ; 54(13): 4901-6, 2006 Jun 28.
Artigo em Inglês | MEDLINE | ID: mdl-16787046

RESUMO

Calcium solubility, dialysability, and transport and uptake (retention + transport) by Caco-2 cells as indicators of calcium bioavailability have been estimated in the in vitro gastrointestinal digests of milk and calcium fortified milk. A significant linear correlation (p < 0.05) was obtained between calcium uptake and the amount of soluble calcium added to the cells, and also between percentage calcium uptake and the calcium measured in the analyzed samples. The solubility, dialysis, transport, and uptake values are higher (p < 0.05) for calcium fortified milks than for nonfortified milks; that is, calcium fortification increases not only calcium content but also its bioavailability. An inhibitory effect of calcium from fortified milks upon iron absorption was found. The observed effect of calcium from fortified milks upon zinc bioavailability depends on the in vitro method used, zinc solubility and dialysis decrease in calcium fortified milks, and percentage zinc uptake remains unchanged.


Assuntos
Cálcio/análise , Cálcio/farmacocinética , Alimentos Fortificados , Ferro/farmacocinética , Leite/química , Zinco/farmacocinética , Animais , Disponibilidade Biológica , Transporte Biológico , Cálcio/farmacologia , Interações Medicamentosas , Ferro/análise , Solubilidade , Zinco/análise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA