Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
J Chromatogr A ; 1338: 92-101, 2014 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-24636755

RESUMO

Granulocyte colony-stimulating factor (G-CSF) is a hematopoietic growth factor regulating granulopoiesis. The recombinant human granulocyte colony-stimulating factor (rhG-CSF) is widely used for the treatment of granulopenia in humans. Filgrastim is a rhG-CSF analogue and is marketed under various brand names, including Neupogen(®) (Amgen), Imumax(®) (Abbott Laboratories), Neukine(®) (Intas Biopharmaceuticals) and others. It is banned in both human and equine sports owing to its potential for misuse. In order to control the abuse of filgrastim in equine sports, a method to identify unequivocally its prior use in horses is required. This study describes an effective screening method for filgrastim in equine plasma by enzyme-linked immunosorbant assays (ELISA), and a follow-up confirmatory method for the unequivocal identification of filgrastim by analysing its highly specific tryptic peptide (1)MTPLGPASSLPQSFLLK(17). Filgrastim was isolated from equine plasma by immunoaffinity purification. After trypsin digestion, the mixture was analysed by nano-liquid chromatography-tandem mass spectrometry (LC/MS/MS). Filgrastim could be detected and confirmed at 0.2ng/mL in equine plasma. The applicability of the ELISA screening method and the LC/MS/MS confirmation method was demonstrated by analysing post-administration plasma samples collected from horses having been co-administered with epoetin alfa as recombinant human erythropoietin (rhEPO) and filgrastim as rhG-CSF. rhEPO and filgrastim could be detected in plasma samples collected from horses for at least 57 and 101h respectively. To our knowledge, this is the first identification of filgrastim in post-administration samples from horses.


Assuntos
Eritropoetina/sangue , Fator Estimulador de Colônias de Granulócitos/sangue , Cavalos , Sequência de Aminoácidos , Animais , Cromatografia Líquida/métodos , Dopagem Esportivo/prevenção & controle , Eritropoetina/química , Eritropoetina/farmacologia , Filgrastim , Fator Estimulador de Colônias de Granulócitos/química , Humanos , Dados de Sequência Molecular , Proteínas Recombinantes/sangue , Proteínas Recombinantes/química , Proteínas Recombinantes/farmacologia , Espectrometria de Massas em Tandem/métodos
2.
Biomed Chromatogr ; 24(7): 744-51, 2010 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-19882746

RESUMO

This paper describes the application of gas chromatography-mass spectrometry (GC-MS) for in vitro and in vivo studies of 6-OXO in horses, with a special aim to identify the most appropriate target metabolite to be monitored for controlling the administration of 6-OXO in racehorses. In vitro studies of 6-OXO were performed using horse liver microsomes. The major biotransformation observed was reduction of one keto group at the C3 or C6 positions. Three in vitro metabolites, namely 6alpha-hydroxyandrost-4-ene-3,17-dione (M1), 3alpha-hydroxyandrost-4-ene-6,17-dione (M2a) and 3beta-hydroxyandrost-4-ene-6,17-dione (M2b) were identified. For the in vivo studies, two thoroughbred geldings were each administered orally with 500 mg of androst-4-ene-3,6,17-trione (5 capsules of 6-OXO((R))) by stomach tubing. The results revealed that 6-OXO was extensively metabolized. The three in vitro metabolites (M1, M2a and M2b) identified earlier were all detected in post-administration urine samples. In addition, seven other urinary metabolites, derived from a further reduction of either one of the remaining keto groups or one of the remaining keto groups and the olefin group, were identified. These metabolites included 6alpha,17beta-dihydroxyandrost-4-en-3-one (M3a), 6,17-dihydroxyandrost-4-en-3-one (M3b and M3c), 3beta,6beta-dihydroxyandrost-4-en-17-one (M4a), 3,6-dihydroxyandrost-4-en-17-one (M4b), 3,6-dihydroxyandrostan-17-one (M5) and 3,17-dihydroxyandrostan-6-one (M6). The longest detection time observed in urine was up to 46 h for the M6 metabolite. For blood samples, the peak 6-OXO plasma concentration was observed 1 h post administration. Plasma 6-OXO decreased rapidly and was not detectable 12 h post administration.


Assuntos
Anabolizantes/análise , Anabolizantes/urina , Androstenos/análise , Androstenos/urina , Cromatografia Gasosa-Espectrometria de Massas/métodos , Cavalos/urina , Anabolizantes/metabolismo , Androstenos/metabolismo , Animais , Dopagem Esportivo , Microssomos Hepáticos/química , Microssomos Hepáticos/metabolismo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA