Radiography (Lond) ; 27(1): 48-53, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32517970

RESUMO

INTRODUCTION: With the current Covid-19 pandemic, general wards have been converted into cohort wards for Covid-19 patients who are stable and ambulant. A 2-radiographer mobile radiography team is required to perform bedside Chest X-rays (CXR) for these patients. Hospital guidelines require both radiographers to be in full Personal Protective Equipment (PPE) throughout the image acquisition process and the mobile radiographic unit needs to be disinfected twice after each case. This affects the efficiency of the procedure and an increase usage of limited PPE resources. This study aims to explore the feasibility of performing mobile chest radiography with the mobile radiographic unit in a "clean" zone of the hospital ward. METHODS: An anthropomorphic body phantom was used during the test. With the mobile radiographic unit placed in a "clean" zone, the phantom and the mobile radiographic unit was segregated by the room door with a clear glass panel. The test was carried out with the room door open and closed. Integrated radiation level and patient dose were measured. A consultant radiologist was invited to review and score all the images acquired using a Barco Medical Grade workstation. The Absolute Visual Grading Analysis (VGA) scoring system was used to score these images. RESULTS: A VGA score of 4 was given to all the 40 test images, suggesting that there is no significant differences in the image quality of the images acquired using the 2 different methods. Radiation exposure received by the patient at the highest kV setting through the glass is comparable to the regular CXR on patient without glass panel at 90 kV, suggesting that there is no significant increase in patient dose. CONCLUSION: The result suggests that acquiring CXR with the X-ray beam attenuating through a glass panel is a safe and feasible way of performing CXR for COVID-19 patients in the newly converted COVID wards. This will allow the mobile radiographic unit as well as one radiographer to be completely segregated from the patient. IMPLICATIONS FOR PRACTICE: This new method of acquiring CXR in an isolation facility set up requires a 2-Radiographer mobile radiography team, and is applicable only for patients who are generally well and not presented with any mobility issues. It is also important to note that a clear glass panel must be present in the barriers set up for segregation between the "clean" zone and patient zone in order to use this new method of acquiring CXR.


Assuntos
COVID-19/diagnóstico , COVID-19/prevenção & controle , Quartos de Pacientes/organização & administração , Radiografia Torácica/métodos , Serviço Hospitalar de Radiologia/organização & administração , Estudos de Viabilidade , Humanos , Imagens de Fantasmas , Doses de Radiação
2.
Radiography (Lond) ; 26(2): e103-e108, 2020 05.
Artigo em Inglês | MEDLINE | ID: mdl-32052763

RESUMO

INTRODUCTION: A study was conducted to determine whether the anode heel effect can be used to influence optimisation of radiation dose and image quality (IQ) for AP pelvis radiography. METHODS: ATOM dosimetry phantom and an anthropomorphic phantom were positioned for AP pelvis. Using a CR system, images were acquired and doses were measured with phantom feet toward anode and then feet toward cathode. Exposure factors (kVp, mAs and SID) were systematically generated using a factorial design. Images were scored visually for quality using relative visual grading together with a 3 point Likert scale. Signal to noise ratio was also calculated as a physical measure of image quality. Dosimetry data were collected for the ovaries and testes. RESULTS: The optimum technique for male, which resulted in lower dose and suitable image quality, was with feet positioned toward the anode (0.80 ± 0.03 mGy; SNR of 38 ± 2.9; visual IQ score 3.13 ± 0.35). The optimum technique for female was with feet toward anode (0.23 ± 0.02 mGy; SNR of 34.7 ± 2.6; visual IQ score 3.15 ± 0.26). kVp had the biggest effect on both visual and physical image quality metrics (p < 0.001) for both tube orientations, whereas SID had the lowest effect on both visual and physical image quality metrics compared with mAs and kVp (p < 0.001). The effect of SID on the SNR was not significant (p > 0.05) with feet toward anode. CONCLUSION: Positioning the patient with feet toward the anode, as opposed to the cathode, has no adverse effect on visual image quality assessment but it does have an effect on physical image quality. IMPLICATIONS FOR PRACTICE: This study would add a new clinical concept in positioning of AP pelvis radiography especially for male positioning.


Assuntos
Posicionamento do Paciente/métodos , Pelve/diagnóstico por imagem , Doses de Radiação , Feminino , Humanos , Masculino , Órgãos em Risco , Imagens de Fantasmas , Radiometria , Fatores Sexuais , Razão Sinal-Ruído