Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
1.
PLoS One ; 16(4): e0250490, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33891632

RESUMO

The objective of this study is to identify essential aspects influencing radiation dose in computed tomography [CT] of the chest, abdomen and pelvis by intraindividual comparison of imaging parameters and patient related factors. All patients receiving at least two consecutive CT examinations for tumor staging or follow-up within a period of 22 months were included in this retrospective study. Different CT dose estimates (computed tomography dose index [CTDIvol], dose length product [DLP], size-specific dose estimate [SSDE]) were correlated with patient's body mass index [BMI], scan length and technical parameters (tube current, tube voltage, pitch, noise level, level of iterative reconstruction). Repeated-measures-analysis was initiated with focus on response variables (CTDIvol, DLP, SSDE) and possible factors (age, BMI, noise, scan length, peak kilovoltage [kVp], tube current, pitch, adaptive statistical iterative reconstruction [ASIR]). A univariate-linear-mixed-model with repeated-measures-analysis followed by Bonferroni adjustments was used to find associations between CT imaging parameters, BMI and dose estimates followed by a subsequent multivariate-mixed-model with repeated-measures-analysis with Bonferroni adjustments for significant parameters. A p-value <0.05 was considered statistically significant. We found all dose estimates in all imaging regions were substantially affected by tube current. The iterative reconstruction significantly influenced all dose estimates in the thoracoabdominopelvic scans as well as DLP and SSDE in chest-CT. Pitch factor affected all dose parameters in the thoracoabdominopelvic CT group. These results provide further evidence that tube current has a pivotal role and potential in radiation dose management. The use of iterative reconstruction algorithms can substantially decrease radiation dose especially in thoracoabdominopelvic and chest-CT-scans. Pitch factor should be kept at a level of ≥1.0 in order to reduce radiation dose.


Assuntos
Meios de Contraste/administração & dosagem , Neoplasias Induzidas por Radiação/epidemiologia , Doses de Radiação , Tomografia Computadorizada por Raios X/efeitos adversos , Abdome/patologia , Abdome/efeitos da radiação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Índice de Massa Corporal , Meios de Contraste/efeitos adversos , Testes Diagnósticos de Rotina , Relação Dose-Resposta à Radiação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neoplasias Induzidas por Radiação/patologia , Neoplasias Induzidas por Radiação/prevenção & controle , Pelve/diagnóstico por imagem , Pelve/patologia , Pelve/efeitos da radiação , Interpretação de Imagem Radiográfica Assistida por Computador/normas , Razão Sinal-Ruído , Tórax/diagnóstico por imagem , Tórax/efeitos da radiação , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA