Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros











Base de dados
Intervalo de ano de publicação
2.
Pacing Clin Electrophysiol ; 40(12): 1374-1379, 2017 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29052249

RESUMO

BACKGROUND: Novel x-ray systems with real-time image noise reduction technology (INRT) to reduce radiation dose during fluoroscopy and cine acquisition have become available. This study evaluated the reduction of radiation dose in device implantation with INRT. METHODS: Radiation dose data from 132 consecutive new device implantation procedures (102 pacemaker [PM] or implantable cardioverter defibrillator [ICD] and 30 cardiac resynchronization therapy [CRT] devices) performed between January 2015 and December 2015 on an angiography system with INRT (Allura ClarityIQ) were collected. For comparison, radiation dose data from 147 consecutive device implantation procedures (121 PM/ICDs and 26 CRT devices) performed between June 2013 and September 2014 on a C-arm system with continuous and pulsed fluoroscopy option (4 frames/second) were evaluated. Total dose area product (DAP), fluoroscopy DAP, and cine DAP were evaluated. RESULTS: Patient age, gender and body weight, procedure, and fluoroscopy times were similar between systems. In PM/ICD cases, DAP of INRT and C-arm system was similar (423 ± 381 cGycm2  vs 417 ± 517 cGycm) due to pulsed fluoroscopy with the C-arm system (78% of time) and sparse use of cine. In CRT procedures requiring higher image quality (82% use of continuous fluoroscopy with C-arm system), DAP of INRT was significantly lower (1,544 ± 834 cGycm vs 7,252 ± 6,431 cGycm, P < 0.001) due to less fluoroscopy DAP (1,414 ± 757 cGycm vs 5,854 ± 6,767 cGycm) and less cine DAP (130 ± 106 cGycm vs 1,399 ± 1,342 cGycm). Considering all procedures, total DAP was reduced by 60% using INRT. CONCLUSION: Novel INRT results in a substantial lowering of radiation dose in device implantation, in particular, in complex CRT implantation procedures requiring high image quality.


Assuntos
Desfibriladores Implantáveis , Fluoroscopia , Marca-Passo Artificial , Implantação de Prótese/métodos , Doses de Radiação , Exposição à Radiação/prevenção & controle , Idoso , Técnicas de Imagem Cardíaca , Feminino , Humanos , Masculino , Estudos Retrospectivos , Cirurgia Assistida por Computador
3.
Am J Cardiol ; 118(3): 353-6, 2016 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-27344273

RESUMO

This study sought to quantitatively evaluate the reduction of radiation dose in coronary angiography and angioplasty with the use of image noise reduction technology in a routine clinical setting. Radiation dose data from consecutive 605 coronary procedures (397 consecutive coronary angiograms and 208 consecutive coronary interventions) performed from October 2014 to April 2015 on a coronary angiography system with noise reduction technology (Allura Clarity IQ) were collected. For comparison, radiation dose data from consecutive 695 coronary procedures (435 coronary angiograms and 260 coronary interventions) performed on a conventional coronary angiography system from October 2013 to April 2014 were evaluated. Patient radiation dosage was evaluated based on the cumulative dose area product. Operators and operator practice did not change between the 2 evaluated periods. Patient characteristics were collected to evaluate similarity of patient groups. Image quality was evaluated on a 5-grade scale in 30 patients of each group. There were no significant differences between the 2 evaluated groups in gender, age, weight, and fluoroscopy time (6.8 ± 6.1 vs 6.9 ± 6.3 minutes, not significant). The dose area product was reduced from 3195 ± 2359 to 983 ± 972 cGycm(2) (65%, p <0.001) in coronary angiograms and from 7123 ± 4551 to 2431 ± 1788 cGycm(2) (69%, p <0.001) in coronary interventions using the new noise reduction technology. Image quality was graded as similar between the evaluated systems (4.0 ± 0.7 vs 4.2 ± 0.6, not significant). In conclusion, a new x-ray technology with image noise reduction algorithm provides a substantial reduction in radiation exposure without the need to prolong the procedure or fluoroscopy time.


Assuntos
Algoritmos , Angioplastia/métodos , Angiografia Coronária/métodos , Vasos Coronários/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Intervenção Coronária Percutânea/métodos , Doses de Radiação , Idoso , Vasos Coronários/cirurgia , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA